Installation Guide for EcoAir models including: ECO15P Room Air Conditioners, Room Air Conditioners, Air Conditioners

EcoAir 15P 14000 btu mobile air conditioner | Industrial | Commercial


File Info : application/pdf, 20 Pages, 1.53MB

PDF preview unavailable. Download the PDF instead.

9336
Installation and Operation Manual

Room Air Conditioners
Portable Heat Pump Range
ECO15P
Register your air conditioner
Model information can be found on the CE label. Please register your product online at www.ecoair.org. For your future convenience, record the model information below. ____________________________________ MODEL NUMBER ____________________________________ SERIAL NUMBER ____________________________________ PURCHASE DATE

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

Congratulations! You have purchased the very latest in room air conditioner technology. Your new EcoAir high efficiency room air conditioner will give you many years of dependable service. Many features have been built into your EcoAir air conditioner to assure quiet operation, the best circulation of cool, dry air, functional controls, and the most economical operation.
CONTENTS
BS Plug Wiring.................................................................................... 1 Specification ........................................................................................ 2 Before Use ...........................................................................................3 Product Description .............................................................................5 Installation............................................................................................6 Mounting of the Exhaust Pipe .............................................................7 Installation of Carbon Filter .................................................................8 Operation of Control Panel..................................................................9 Self Diagnosis .................................................................................... 12 Drainage ............................................................................................ 13 Maintenance ...................................................................................... 15 Fault Checklist ................................................................................... 16 Easy to Order Form for Accessories .................................................. 17
Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. When this product reaches its end of life, contact your local authorities regarding disposal.

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

BS Plug Wiring

Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code :
BLUE - NEUTRAL BROWN ­ LIVE GREEN AND YELLOW - EARTH

As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

1. The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked with the letter N or coloured BLACK.

2. The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED.

3. The GREEN/YELLOW is the EARTH and must be connected to the

terminal which is marked with the letter E or

or coloured

GREEN OR GREEN/YELLOW.

4. Always ensure that the cord grip is positioned and fastened correctly.

If a 13A (BS 1363) fused plug is used it must be fitted with a 13A fuse. If in doubt consult a qualified electrician.

Wiring for a 13 Amp Plug (BS1363)
Please note. The Earth Terminal is marked with the letter E or

Earth Symbol

- 1 -

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

SPECIFICATION

Model no.
Cooling capacity
Heating capacity
Power/Ampere consumption for cooling Power/Ampere consumption for heating Air volume (max. speed) Humidity removal capacity Power supply Compressor Noise Level Refrigerant Fan speed Timer
Working temperature
Exhaust pipe Net Weight Gross Weight Net Dimension Gross Dimension

ECO15P 15000 BTU/hr
4395watts 15000 BTU/hr
4395watts
1655 W/ 7.5A
1280 W/ 5.9A 550m3/h 1.6L/hour
220-240V~. 50Hz rotary 55 dB
R410A (560g) 3
1 24 hours
Cooling: 18 ~ 32oC Heating: 7 ~ 25oC Ø 145x1500mm
33.5 kgs
38.5 kgs
422x825x443 mm (WxHxD)
490x875x575 mm (WxHxD)

REMARK: 1. Measuring condition for above is as per EN 14511 :
Cooling ­ DB=35°C , WB=24°C Heating ­ DB=20°C , WB=12°C
*DB = temperature of dry bulb = room temperature,
WB = temperature of wet bulb = relative humidity.

- 2-

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

·

!"
· #
· %
·

!%

' '%

( &

" $!" "
& &

"

%

"

· · %
" ·
· "
·
&

" %
% )!
& * +"

- 3 -

FIG. 1 FIG. 2
FIG.3

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

· , -,. /0 //1 .2/ 3/ , /-1/1 3,, 4 5/"
· 67/ -., .2/ 6 ,8-. .2/ -8 9/3 ,: ;/,;</ ,3 /=8 ; /-. 84/1 - .2/ 3,, 64 .2/4/ ;3,18 /4 2/6. 6-1 > << 3/18 / .2/ ,,< /::/ . ?/-/44"
· ?, 1 ,;/- - 1,,34 :3/=8/-.<@"
· '//; 83.6 -4 ,: 9< -14 <,4/1 183 - .2/ >63 /4. ;63. ,: .2/ 16@"
· '//; : <./34 </6-"
FIG.4
· - / 3,, 264 3/6 2/1 .2/ 1/4 3/1 ,-1 . ,-4& 3/18 / ./ ;/36.83/ 6-1 ?/-. <6. ,- 4/.. - "
· , 6./ 6 3 ,-1 . ,-/3 >2/3/ 6 3:<,> 4 -,. ,94.38 ./1 ., - 3/64/ 6 3 :<,>"
· <,4/ 6-@ 6 3 3 <</4& > -1,>4 ,3 18 . - ., 6?, 1 ,,</1 6 3 /4 6; - 183 - 84/"

- 4-

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

Front

Back

FIG.5
1. Control Panel 2. Air vent 3. Handle 4. Caster
Accessories
10. Exhaust hose. 11. PVC strip - for filling the open
window space 12. PVC strip - for filling the open
window space 13. PVC strip (with hole) - for filling the
open window space and with hole for connection to tie-in 14. Outward adaptor - for insertion over hose and into PVC strip (or into hole in the wall/window). 15. Cover for outward adaptor 16. Remote control 17. Active carbon filter
18. Tube for continuous drainage

FIG.6
5. Air filter 6. Air inlet 7. Cord storage 8. Outlet of exhaust air 9. Water stopper / outlet of condensed
water

- 5 -

FIG.7

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

Installation of the exhaust pipe The unit is a portable air conditioner that may be moved from room to room. 1. Using the PVC strip
PVC strip

FIG.8 · Offer PVC strips to the window gap and adjust to size if necessary. · Connect one end of the exhaust pipe to outlet of exhaust air and the other end with
the outward adapter. · Feed the exhaust hose to the PVC strip as shown and slide window across so that
PVC strip is held securely. Note: Take care to maintain protection against intruders.
2. Using the adaptor
Wall or Window
Outward adaptor
FIG.10

FIG.9
· Cut a 151mm diameter hole in the wall or window. · Feed exhaust hose through the window or wall and attach the threaded adaptor from
the outside as shown. · When not in use, plug the hole with the cover provided.
- 6 -

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

MOUNTING OF THE EXHAUST PIPE
· Use only the hose provided and clip exhaust hose and unit adaptor to the back of the air conditioner.
· Avoid kinks and bends in the exhaust hose as this will cause expelled moist air to build up causing the unit to overheat and shut down. Fig 8 & 9 show correct position.
· The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible.

FIG.11 FIG.12 FIG.13

FIG.14

- 7 -

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

INSTALLATION OF CARBON FILTER

1. Remove the filter frame from the unit.

FIG.15

2. Separate the filter fixer from the filter frame.

3. Remove the active carbon filter from its plastic bag.

4. Insert the active carbon filter into the filter frame.

5. Fix the filter by reassembling the fixer onto the filter frame.

6. Re-fit the filter frame inside the unit.

- 8 -

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

OPERATION OF THE CONTROL PANEL
Control panel

FIG.16

1. Speed (ventilation) button 2. Timer button 3. Display window 4. Receiver for remote control 5. Heating operation indicator(optional) 6. Mode (function) button 7. Auto operation indicator 8. Cooling operation indicator 9. Fan operation indicator 10. "Temperature up" button 11. "Temperature down" button 12. Power indicator

13. "Water Full" indicator 14. ON/OFF (power) button 15. Sleep function button 16. TiO2(UV light)/Ionizer button (optional) 17. Indicator for compressor 18. TiO2(UV light)/ionizer indicator (optional) 19. Sleep operation indicator 20. Timer operation indicator 21. Low ventilation indicator 22. Medium ventilation indicator 23. High ventilation indicator

Turning ON/OFF Adjust the louvers to desired angle and position. Press ON/OFF button, the unit will start to work. If the ambient temperature is
higher than 23oC, the unit will work in cool mode. higher than 20oC but below or equal to 23oC, the unit will work in ventilation model. below 20oC, the unit will work in heat function (This is for cooling & heating models only)
- 9 -

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

Indicators of the functions in progress come on at the same time. *NOTE! The display window shows the ambient room temperature from 0oC to 50oC To turn the unit off, press ON/OFF button again, then close the air louvers.
Setting mode/function
Press MODE button to select required working mode: automatic, cooling, fan or heat (Heat is only available for heating & cooling models.) Indicator of the selected mode comes on.
Setting temperature 1. Press 'Temperature up' or 'Temperature down' button to regulate the temperature you
desired. 2. The display window will show the temperature you set as you press 'Temperature up' or
'Temperature down' button. Otherwise, it will always show the ambient temperature. 3. The pre-setting temperature of this machine is: 24oC for cooling, 20oC for heating.
Setting ventilation speed 1. Press SPEED button to choose the ventilation speed you need, high, medium or low.
The sign of high, low or medium ventilation will light on at the same time. 2. If the unit is in AUTO mode, it will choose the ventilation speed automatically according
to the ambient temperature.
Setting timer
1. Press TIMER button to set the operating hours you desired (1 to 24 hours, the sign of timer will light on). The window will show the hour(s) you set as you press TIMER button. If the timer button is not pressed, the unit will work continuously.
2. By pressing the timer but without turning on the other functions, you can PRE-SET the time for the machine to work. For example, if you press the timer to '2', the unit will work automatically after 2 hours.
Sleep function 1. In cooling mode, by pressing the SLEEP button, the set temperature will increase 1oC
at the 1st hour, another 1 oC at the second hour, then keeps at that temperature. 2. In heat mode, by pressing the SLEEP button, the set temperature will descend 1oC at
the 1st hour, another 1 oC at the second hour, then keeps at that temperature.

- 10 -

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

3. In SLEEP mode, the ventilation will be kept at low speed. Re-press the SLEEP button, the setting temperature and ventilation speed will return to the pre-selected one.
4. In SLEEP mode, the unit will shut down automatically after running for 12 hours. 5. Please note, the sleep function is not available while the machine is working in
ventilation. Only available in Cooling or Heating mode. Heating function (This is optional, only for cool & heat model.) 1. When using Heat Pump, the ambient warm air is recycled and use to heat the area
where it is required. The Exhaust Pipe must be fitted firmly to allow the cold air to be removed outside. 2. Continuous drain is compulsory while the unit is in heat mode. Working ambient temperature range for heating function is 5 to 27oC.
Regulating air flow direction Adjust the air louvers by hand to control the air flow direction.
FIG. 17

- 11 -

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

This machine is equipped with self-diagnosis function. Please contact us if your machine displays "E1" or "E2" codes.
All the above functions can also be performed with the supplied remote control. This remote control requires 2 pcs. AAA size batteries to operate.
FIG.18
NOTICE ! 1. To prolong the compressor's life, after switching off the unit, please wait for a
minimum of 3 minutes before switching on again. 2. The cooling system will switch off if the ambient temperature is lower than the set
temperature. The ventilation, however, keeps working on the set level. If the ambient temperature rises above the selected level, the cooling will return to work. 3. The heating will switch off if the ambient temperature is higher than the set temperature. The ventilation keeps working on the set level. As the ambient temperature drops below the selected level, the heating will return to work. 4. This machine is equipped with ANTI-FROST function. While using the heating function during low temperature, sometimes the heating will stop for a while in order to melt the frost. As this occurs, just wait for the heating to return to work.

- 12 -

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

During the process of cooling, some water will be extracted from the air into the unit. Most of the water will be evaporated by the coil for maximum efficiency. However in very warm temperature or humid condition, excessive condensation may occur and will require water drainage when tank is full. If the tank is full, both of the compressor and motor will stop. The "water full" sign will light ON, also the machine will beep as reminder.
To make the cooling work again, please empty the water by one of the following ways:

1. Turn off the air conditioner and avoid moving it when full.
2. Position a container (a water tray for example) underneath the drain hole.
3. Remove the drain knob & rubber plug from the drain hole and allow the water to drain out.
4. When the container is almost full, replace the rubber plug in the drain hole and empty the water tray.
5. Repeat until the unit is emptied.
6. Replace the rubber plug and tighten the drain knob firmly.
7. Switch on the unit - the full water or compressor operating indicator should not be flashing.

FIG.19

If you wish to operate the unit without the need to empty the water tank, please:

· Remove the drain knob and rubber plug and retain for future use.
· Connect the drain tube supplied to the water outlet as shown and locate the other end into a drain.

FIG.20

- 13 -

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

· The drain tube may be extended by adding an extension tube and using a suitable connector.

Please note
1. The drain must be at or below the outlet level.
2. Flashing comp / `full water' indicator will not function in this mode of drainage.
3. If you want to extend the water tube, you can connect it with another tube (OD: 18mm)

Special caution for heating function!

While using the heating function, please note:

1. Install the exhaust pipe well, in order to exhaust the cool air to outdoor. (Please refer to the instruction manual for installation method.)

2. Fix the drainage to be continuous one (i.e. drain the water by water tube). This is compulsory for use in heating mode. This is compulsory for use in heating mode.

3. Working range for heating function is 7 to 27oC (for cooling function, it is 18 to 32oC). For temperature outside this range, the unit may not work properly.

- 14 -

FIG.21 FIG.22 FIG.23

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

Always unplug the air conditioner from the mains before cleaning. To maximize the efficiency of the air conditioner, clean regularly.

Cleaning the housing Use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions. These all could possibly hurt the cabinet.

Cleaning the filter Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse thoroughly under running water (no hotter than 40oC). Dry thoroughly before replacing. Notice! Never operate the unit without the filters.

End of season storage

· Drain any water in the unit before completely operating the unit on ventilation only mode for a few hours, to thoroughly dry the inside.

· Clean or change the filter
· Unplug and store the power cord as shown

Cover for cord compartment

· Cover the cord storage

· Place in the original carton or cover for storage.

Power cord
FIG.24

- 15 -

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

2/ 6 3 ,-1 . ,-/3 1,/4 -,. 382/ 6 2 -/ 4// 4 ., 1, < ..</
2/ 6 2 -/ 4// 4 ., 1, -,.2 - " ,, -, 4@ 2/ , ;3/44,3 1,/4-A. 38-"

Is the air conditioner plugged in? Is there a power failure? Is the comp / `full water' indicator flashing? Is the room temperature below the set temperature?
Is there direct sunshine? (Please put down the curtain.) Are too many windows or doors open? Are there too many people in the room? Is there something in the room producing lots of heat?
Is the filter dusty, contaminated? Is the air intake or output blocked up? Is the room temperature below your selected temperature?
Is the machine positioned unevenly so as to create vibration? Is the floor underneath the machine uneven?
Is so, it is possible the overheat protection of the compressor is on. Just wait for the temperature to drop.

 Never try to repair or dismantle the unit yourself

- 16 -

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

EASY TO ORDER FORM FOR ACCESSORIES
(Please complete in BLOCK CAPITALS in black ink) Full Name: Previous Invoice No.: (If available) Model No. Delivery Address:

Telephone No.: Email Address: Signature

DESCRIPTION

PRODUCT CODE

Filters Rear Filter & Fixer Side Filter Filter Track Active Carbon Filter

15P-108&109 15P-110 15P-116 15P-806

Remote Control

15P-205

Exhaust Accessories

Exhaust Hose (1.5m)

15P-141

Tube for continuous drainage 15P-137

Extension drainage tube (1m) 15P-817

Water Bung Other Accessories

15P-135

Caster Wheels

15P-308

PVC Window Kit

15P-144,145&146

Round Window Connector Set 15P-142&143

QTY

UNIT PRICE
£14.99 £14.99 £8.99 £12.99 £19.99

£24.99 £6.99 £4.99 £6.99
£4.99 £19.99 £14.99 Sub Total Standard Delivery(Free) Next Day Delivery(Call)
TOTAL

TOTAL

* Price includes VAT and shipping to UK mainland only (except Scottish Highlands and remote areas) *Note: Please see page 5 for your reference.
To place your order... Call us on 020 8459 2458 , Fax 020 8451 1587 Unit 7 Propeller Park, 400 Circular Road, London, NW10 0AB

- 17 -

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH

ONE (1) YEAR LIMITED WARRANTY SAVE THIS WARRANTY INFORMATION
EcoAir guarantees this product free from defects in materials and workmanship for a period of one (1) year from the date of purchase, limited to parts only.
Faults arising from a faulty installation is specifically excluded.
This unit must be operated under conditions as recommended, at voltages indicated on the unit. Any attempts made to service or modify the unit by unqualified technician, will render this WARRANTY VOID. The actual product may differ slightly from the illustration. This warranty is in addition to, and does not affect, your statutory rights.
For after sales needs, please visit www.ecoair.org/service or email technical@ecoair.org or contact +44 845 474 3574

We recommend that you note the details of your purchase below and retain your original proof of purchase receipt with this manual. Keep these documents safe in the event of a warranty claim.

Date of purchase:

_____________________________

Purchased from (Dealer Name): _____________________________

Retailer name:

_____________________________

Model number:

_____________________________

Serial number:

_____________________________

Date of installation:

_____________________________

Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk

Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire, BD24 9RH



References

FPDF 1.82