Instruction Manual for Acuity Brands models including: LED Light Bar Kit, Light Bar Kit, LED Light Bar, Light Bar, Bar
LBK - LED Light Bar Kit
File Info : application/pdf, 7 Pages, 682.95KB
DocumentDocumentLED IM PORTANT SAFETY INSTRUCTIONS Pre-Launch READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce t he risk of deat h, personal injury or propert y damage from fire, electric shock, falling part s, cut s/ abrasions, and ot her hazards please read all w arnings and inst ruct ions included wit h and on t he fixt ure box and all fixt ure labels. Before inst alling, servicing, or perform ing rout ine m aint enance upon t his equipm ent , follow t hese general precaut ions. Inst allation and service of lum inaires should be performed by a qualified licensed electrician. M aint enance of t he lum inaires should be performed by person(s) familiar w it h t he luminaires' const ruction and operation and any hazards involved. Regular fixt ure m aint enance program s are recomm ended. It will occasionally be necessary t o clean t he out side of the refract or/ lens. Frequency of cleaning will depend on am bient dirt level and minim um light out put w hich is accept able t o user. Refract or/ lens should be w ashed in a solut ion of w arm w at er and any mild, non-abrasive household det ergent , rinsed wit h clean w at er and w iped dry. Should optical assem bly becom e dirty on t he inside, wipe refract or/ lens and clean in above m anner, replacing dam aged gasket s as necessary. DO NOT INSTALL DAM AGED PRODUCT! This luminaire has been properly packed so t hat no part s should have been dam aged during t ransit. Inspect t o confirm. Any part dam aged or broken during or after assem bly should be replaced. Recycle: For inform at ion on how t o recycle LED elect ronic product s, please visit w w w.epa.gov. These inst ruct ions do not purport t o cover all det ails or variat ions in equipm ent nor t o provide every possible cont ingency t o meet in connect ion wit h inst allat ion, operat ion, or m aintenance. Should furt her inform at ion be desired or should part icular problem s arise w hich are not covered sufficient ly for the purchaser's or ow ner's purposes, t his m att er should be referred t o Acuit y Brands Lighting, Inc. W ARNING RISK OF ELECTRIC SHOCK Disconnect or turn off pow er before installation or servicing. Verify that supply voltage is correct by comparing it w ith the luminaire label i nf or m at i on. M ake all electrical and grounded connections in accordance w ith the National Electrical Code (NEC) and any applicable local code requirements. All wiring connections should be capped w ith UL approved recognized w ire connect or s. CAUTION RISK OF INJURY Wear gloves and safety glasses at all times w hen removing luminaire from carton, installing, servicing or performing m ai nt enance. Avoid direct eye exposure to the light source while it is on. 912-00089-002 W ARNING RISK OF BURN Allow lamp/ fixture to cool before handling. Do not touch enclosure or light source. Do not exceed maximum w attage marked on luminaire label. Follow all manufacturer's w arnings, recommendations and restrictions for: driver type, burning position, mounting locations/ methods, replacement and r ecycl i n g. CAUTION RISK OF FIRE Keep combustible and other materials that can burn, aw ay from lamp/ lens. Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying. Page 1 of 7 LED IM PORTANT SAFETY INSTRUCTIONS Pre-Launch CAUTION: RISK OF PRODUCT DAM AGE Never connect components under load. Do not mount or support these fixtures in a manner t hat can cut the outer jacket or damage w ire insulation. Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-w ired to the luminaire must be checked for com patibility w ith the luminaire prior to installation. LED fixtures must be pow ered directly off a sw itched circuit. Unless individual product specifications deem otherw ise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixt ure. Avoid covering LED fixtures w ith insulation, foam, or other material that w ill prevent convection or conduction cooling. Unless individual product specifications deem otherw ise: Do not exceed fixtures maximum ambient t em per at ur e. Only use fixture in its intended location. LED products are Polarity Sensitive. Ensure proper Polarity before installation. Electrostatic Discharge (ESD): ESD can damage LED fixt ures. Personal grounding equipment must be w orn during all installation or servicing of the unit. Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter per f or m ance. Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, st op using t he unit im m ediat ely and cont act an ABL represent at ive for assist ance. Alw ays read the fixtures complete installation instructions prior to installation for any additional fixture specific w arnings. Alw ays ensure that the electrical distribution system is up to NEC (and any applicable local code) r equi r em ent s. Verify that pow er distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void w arranty. All luminaires t hat contain elect ronic devices t hat generat e frequencies above 9kHz from any component w it hin t he luminaire comply w it h Part 15 of t he FCC Rules. Operat ion is subject t o the following tw o conditions: (1) This device may not cause harmful interference (2) This device must accept any int erference received, including interference that may cause undesired operation Failure t o follow any of t hese inst ruct ions could void product w ar rant ies. For a com ple t e list ing of product Term s and Con dit ion s, p le a se visit w w w .a cu it yb ra n ds.co m . Our Brands Indoor/ Outdoor Lit honia Light ing Carandini Holophane RELOC Light Concept s Indoor Lighting Got ham M ark Archit ect ural Light ing Peerless Renaissance Light ing Winona Light ing Outdoor Lighting American Elect ric Light ing Ant ique St reet Lamps Hydrel Tersen Co n t ro ls DARK TO LIGHT LC& D ROAM Sensor Sw it ch Synergy Dayligh t in g SunOpt ics Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. ABL LED General W arnings, Form No. 503.203 © 2010, 2016 Acuity Brands Light ing, Inc. All right s reserved. 12/ 01/ 10 912-00089-002 Page 2 of 7 Pre-Launch LED IM PORTANT SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS LBK TROFFER Inst allat ion inst ruct ions for Fixt ure Conversion Ret rofit Classified by Underw rit ers laborat ory Inc The Ret rofit Kit cont ains LIGHT BAR #8-18 TEK SCREWS #8-18 PAN HEAD TEK SCREWS Lengt h of kit 2 FT 4 FT 4 FT No. of Light bars Qt y. (2) - 2FT BAR Qt y. (1) - 4FT BAR Qt y. (2) - 4FT BAR No. of LED Drivers 1 1 1 Hardw are (12) TEK SCREWS, (2) PAN HEAD TEK SCREWS, (1) 2FT RED JUM PER, (1) 2FT BLUE JUM PER (10) TEK SCREWS, (2) PAN HEAD TEK SCREWS, (1) 2FT RED JUM PER, (1) 2FT BLUE JUM PER (12) TEK SCREWS, (2) PAN HEAD TEK SCREWS, (1) 2FT RED JUM PER, (1) 2FT BLUE JUM PER 912-00089-002 Page 3 of 7 Pre-Launch LED IM PORTANT SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS LBK TROFFER M inimum dimensions of t he host housing This Retrofit Kit is designed to fit housings w ith minimum dimensions: 4.9 inches 2.3 inches W ARNING Risk of fire or electric shock. Lum inaires w iring, ballast s, or ot her elect rical part s m ay be dam aged w hen drilling for inst allation of reflect or kit hardw are. Check for enclosed wiring and com ponent s. W ARNING Risk of fire or electric shock. Inst all t his kit only in luminaires t hat have t he const ruct ion feat ures and dim ensions show n in t he phot ographs and/ or draw ings and w here t he input rat ing of t he Ret rofit Kit does not exceed t he input rating of t he luminaire. W ARNING To prevent wiring damage or abrasion, do not expose w iring t o edges of sheet met al or ot her sharp object s. * * * Locate t he fluorescent lighting fixt ure t hat is t o be ret rofit t ed. Turn off power. W ARNING Electrical shock can occur during ret rofit com ponent inst allation if power is not t urned off. W ARNING Risk of fire or electric shock. LED Retrofit Kit inst allat ion requires knowledge of luminaires elect rical syst ems. If not qualified, do not at t em pt inst allation. Cont act a qualified elect rician. W ARNING As indicat ed in t he individual inst allat ion instruct ion: Do not m ake or alter any open holes in an enclosure of wiring or elect rical com ponent s during kit inst allat ion or Only t hose open holes indicat ed in t he phot ographs and/ or draw ings m ay be m ade or altered as a result of kit inst allat ion. Do not leave any ot her open holes in an enclosure of w iring or elect rical com ponent s. W ARNING Ensure that exist ing fixt ure is and rem ains properly connected t o building ground. Use of any ot her t han Acuit y Brands supplied screw s t o inst all assem bly m ay result in ungrounded fixt ure com ponent s. 912-00089-002 Page 4 of 7 Pre-Launch LED IM PORTANT SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS LBK TROFFER Inst allat ion Inst ruct ions: Step 1: Verify fixt ure pow er is t urned off. Rem ove lam ps and channel/ ballast cover from exist ing fixt ure. Ident ify and disconnect pow er supply w ires. Rem ove ballast (s), invert inst all lam pholders, and rem ove int ernal wiring t o provide adequate clearance for Retrofit Kit inst allat ion. Represent at ive t andem host housing wit h lam ps, channel cover, lam pholder bracket s, and lam pholders rem oved. Step 2: Inst all t he LED Driver provided inside t he housing at t he same location as ballast using t he self t apping screw s provided. 912-00089-002 #8-18 PAN HEAD TEK SCREW S Page 5 of 7 LED IM PORTANT SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS LBK TROFFER Step 3: At t ach safety tet her t o host housing using exist ing nail pierce/ extruded holes and provided self t apping screw s. Cent er and inst all Light bar in host housing using self t apping screw s provided (m inim um 2 screw on eit her side). Connect LED Harness (red and blue) t o t he LED Driver (red and blue). NOTE: If there is more than one Lightbar, connect individual LED harnesses to the LED driver in the housing using red and blue wire jumpers provided. (See w iring below ) M ake sure t o rout e t he w ire jum pers t hrough exist ing knockout s on housing endcaps and use t he bushing provided t o prot ect t he wire jum pers. Connect input pow er t o LED driver #8-18 TEK SCREW S Pre-Launch 912-00089-002 Page 6 of 7 LED IM PORTANT SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS LBK TROFFER Wiring Diagrams 1 LightBar Solution 2 LightBar Solution Pre-Launch 3 Lightbar Solution Step 4: Inst all original ballast cover over t he driver and t hen inst all t he diffuser fram e ont o host housing. Turn on t he fixture. 912-00089-002 Ballast Cover Diffuser Fram e 4 LightBar Solution Page 7 of 7