Instruction Manual for SMART DENTURE CONVERSIONS models including: Lab Analog and Coating Mandrel, Analog and Coating Mandrel, Coating Mandrel, Mandrel

Andrew Wood

IFUs – Smart On X


File Info : application/pdf, 6 Pages, 281.84KB

PDF preview unavailable. Download the PDF instead.

IFU-007 - Rev F - Lab Analog and Coating Mandrel ?v=1725031870
Instructions for Use (IFU)
Lab Analog and Coating Mandrel
Manufacturer: Smart Denture Conversions, LLC 1800 N. Salem St. Suite 104 Apex NC, 27523 855-550-0707 www.SmartDentureConversions.com

Training: The following descriptions are insufficient to allow immediate use of the Smart Denture Conversions' system. Knowledge of implant-prosthetic treatment and instruction in the handling of the Smart Denture Conversions' system provided by an operator with the relevant experience are necessary. It is strongly recommended that new and experienced users of Smart Denture Conversions' products complete special training before using a new product for the first time. Smart Denture Conversions offers a variety of training options. Please go the
www.SmartDentureConversions.com for more information.

Product Description: Lab Analog The Lab Analog is designed to simulate the prosthetic side of a multi-unit abutment and can be used in a quick set stone model to create a repair jig or stone model. It is also used in packaging to hold the Separable Fastener, TiBase and Prosthetic Screw in a single unit.

Coating Mandrel The Coating Mandrel is used to hold the TiBase and Separable Fastener together, making it easier to precoat the two components together with acrylic. Precoating allows for an easier handle of the combined components, ensures acrylic fills all crevices for a better pickup and prevents the PEEK Cap from spinning when drilling through it later in the process. The Coating Mandrel can be held by hand or in a lab handpiece with a 2.35mm collet, run at the lowest speed setting. The table below summarizes the items:

Name
Lab Analog, M1.4
Coating Mandrel, M1.4 Lab Analog, #1-72
Coating Mandrel, #1-72 Lab Analog, Omnibut Coating Mandrel, Omnibut

Part Number
SFT-003
SFT-008 PT-007 PT-008 OA-008 OA-009

Compatible Separable Fastener
ASF-001, ASF-001L, ASF-002, ASF-002L, ASF-003, ASF-003L, ASF-005, ASF-005L
ASF-004, ASF-004L

Compatible TiBases
SF-003/SF-004 SF-012/SF-012L
PT-003/PT-004

ASF-006, ASF-006L OA-003/OA-003L

Compatible Prosthetic
Screw PS-001, PS-002, PS-003, PS-005, PS-006, PS-007,
PS-008
PS-004

Material
300 Series Stainless
Steel

OA-506

# of Uses
Single

Indications for Use: Lab Analogs and Coating Mandrels are intended for use with the compatible Smart Denture Conversions' Separable Fastener, Prosthetic Screw and TiBases and are intended for use within the lab. Lab Analogs and Coating Mandrels are not for patient contact and are intended for single use. Re-use of single use devices creates a potential risk of patient or user infection and misfitting components. For more specific information on process steps, please refer to the Technique manual located on the website www.SmartDentureConversions.com.

Note: The Prosthetic Screw/Separable Fastener must be properly aligned with the axis of the threaded hole in the

Lab Analog or Coating Mandrel. Failure to properly align the axis' can cause damage to either or both components.

IFU-007 Rev F

Page 1 of 6

Instructions for Use (IFU)
Lab Analog and Coating Mandrel

Contraindications: It is contraindicated to using Smart Denture Conversions' Pin Vise if: · Operator or Patient shows signs of allergy or hypersensitivity to the chemical components of the materials listed in the chart above.
Warning: · The supplied Lab Analog and Coating Mandrel are intended for laboratory use by a trained technician. · Components are to be used by dental health care professionals and are to be used in patients subject to dental implant treatment. · If the indication or the nature of use is not clear, do not use until all points have been clarified. · Do not use if package is damaged. · Always inspect components before use. Do not use damaged, deformed, corroded, or discolored components. · Overtightening may cause components to become deformed, broken or stuck resulting in damage to components. · Smart Denture Conversions is not liable for damage resulting from use outside the intended use of the product.

Cautions/Precautions: The following precautions are required before or during treatment: · Do not use Smart Denture Conversion components after the expiration date indicated on the packaging. · All products intended for single use must not be reused. Re-use of single use devices creates a potential risk of patient or user infection and misfitting components. · Before every procedure make sure that all required components, instruments, and auxiliary equipment are complete, in operating order and available in the required quantity. · If, due to unfavorable anatomical conditions, instruments do not fit or cannot be used for other reasons, the course of treatment planned with them must not be continued and alternatives must be sought. · Always wear suitable personal protective equipment for your own safety. · Position the patient such that the danger of aspiration of components is minimized. · All components used in the patient's mouth must be secured to prevent aspiration and swallowing.

Sterilization Instructions: Components are delivered non-sterile by Smart Denture Conversions and are intended for single use. Prior to use, the devices must be sterilized by the user.

Smart Denture Conversions recommends the following procedure for sterilization prior to use. Sterilization is recommended to be performed corresponding to the following scheme:

1. Preparation for sterilization: Place components (up to 6 devices) in a sterilization pouch which is FDA-cleared for the intended cycle.
2. Sterilization:

Method

Cycle

Steam

Dynamic Air Removal (Prevacuum)

Temperature 132°C (270°F)

Exposure Time* Dry Time

4min

20min

Steam Gravity Displacement

121°C (250°F)

30min

30min

*Minimum exposure times, the operating times are longer and may vary depending on the device.

Storage, Handling and Transportation: The devices must be stored in a dry place in their original packaging at room temperature and protected from direct sunlight. Improper storage may compromise essential material and design characteristics, leading to device failure.

IFU-007 Rev F

Page 2 of 6

Instructions for Use (IFU)
Lab Analog and Coating Mandrel
Disposal: Safely discard potentially contaminated or no longer usable medical devices as healthcare (clinical) waste in accordance with local healthcare guidelines, country and government legislation or policy. Separation, recycling, or disposal of packaging material shall follow local country and government legislation on packaging and packaging waste, where applicable. If there is no current legislation, pack them in a perforating waste/sharps disposal container and dispose of them in hospital waste.

IFU-007 Rev F

Page 3 of 6

Instructions for Use (IFU)
Lab Analog and Coating Mandrel

Basic UDI-DI Information:

The following table lists the Basic UDI-DI information for the devices described in this IFU.

Product

Catalog Number Included Parts

Basic UDI-DI Number

Lab Analog 10PK

LA10PK

SFT-003

+D990LA10PK0

Coating Mandrel 6PK

CM6PK

SFT-008

+D990CM6PK0

Coating Mandrel 10PK

CM10PK

SFT-008

+D990CM10PK0

Lab Analog 10PK, Paltop

KDIH-LA10PK

PT-007

+D990KDIH-LA10PK0

Coating Mandrel 6PK, Paltop (IHex)

KDIH-CM6PK

PT-008

+D990KDIH-CM6PK0

Coating Mandrel 10PK, Paltop (IHex)

KDIH-CM10PK

PT-008

+D990KDIH-CM10PK0

Premium Starter Kit, SDC

PSK

SFT-003/SFT-008

+D990PSK0

Starter Kit, SDC

SK

SFT-003

+D990SK0

Recharge Kit w/ Tall Spare Parts, SDC

RK

SFT-003

+D990RK0

Recharge Kit w/ POC, SDC

RKPOC

SFT-003

+D990RKPOC0

Separable Fastener Assembly 10-pack with Drill kit

SFA10PKDK

SFT-003

+D990SFA10PKDK0

Premium Starter Kit, Straumann

PSK-ST

SFT-003/SFT-008

+D990PSK-ST0

Starter Kit, Straumann

SK-ST

SFT-003

+D990SK-ST0

Recharge Kit w/ Tall Spare Parts, Straumann

RK-ST

SFT-003

+D990RK-ST0

Recharge Kit w/ POC, Straumann

RKPOC-ST

SFT-003

+D990RKPOC-ST0

Separable Fastener Assembly 10-pack with Drill kit, Straumann

SFA10PKDK-ST

SFT-003

+D990SFA10PKDK-ST0

Premium Starter Kit, TiLobe

KDTL-PSK

SFT-003/SFT-008

+D990KDTL-PSK0

Starter Kit, TiLobe

KDTL-SK

SFT-003

+D990KDTL-SK0

Recharge Kit w/ Tall Spare Parts, TiLobe

KDTL-RK

SFT-003

+D990KDTL-RK0

Recharge Kit w/ POC, TiLobe

KDTL-RKPOC

SFT-003

+D990KDTL-RKPOC0

Separable Fastener Assembly 10-pack with Drill Kit, TiLobe

KDTL-SFA10PKDK

SFT-003

+D990KDTL-SFA10PKDK0

Premium Starter Kit, Paltop

KDIH-PSK

PT-007/PT-008

+D990KDIH-PSK0

Starter Kit, Paltop

KDIH-SK

PT-007

+D990KDIH-SK0

Recharge Kit w/ Tall Spare Parts, Paltop

KDIH-RK

PT-007

+D990KDIH-RK0

Recharge Kit w/ POC, Paltop

KDIH-RKPOC

PT-007

+D990KDIH-RKPOC0

Separable Fastener Assembly 10-pack with Drill kit, Paltop

KDIH-SFA10PKDK

PT-007

+D990KDIH-SFA10PKDK0

Premium Starter Kit, BioHorizons

BHHD-PSK

SFT-003/SFT-008

+D990BHHD-PSK0

Starter Kit, BioHorizons

BHHD-SK

SFT-003

+D990BHHD-SK0

Recharge Kit w/ Tall Spare Parts, BioHorizons

BHHD-RK

SFT-003

+D990BHHD-RK0

Recharge Kit w/ POC, BioHorizons

BHHD-RKPOC

SFT-003

+D990BHHD-RKPOC0

Separable Fastener Assembly 10-pack with Drill kit, BioHorizons

BHHDSFA10PKDK

SFT-003

+D990BHHD-SFA10PKDK0

Premium Starter Kit, TSV

ZVTS-PSK

SFT-003/SFT-008

+D990ZVTS-PSK0

Premium Starter Kit, Low Profile

ZVLP-PSK

SFT-003/SFT-008

+D990ZVLP-PSK0

Recharge Kit w/ Tall Spare Parts, TSV

ZVTS-RK

SFT-003

+D990ZVTS-RK0

Recharge Kit w/ Tall Spare Parts, Low Profile

ZVLP-RK

SFT-003

+D990ZVLP-RK0

Recharge Kit w/ POC, TSV

ZVTS-RKPOC

SFT-003

+D990ZVTS-RKPOC0

Recharge Kit w/ POC, Low Profile

ZVLP-RKPOC

SFT-003

+D990ZVLP-RKPOC0

Separable Fastener Assembly 10PK - Drill Kit Included, TSV

ZVTS-SFA10PKDK

SFT-003

+D990ZVTS-SFA10PKDK0

IFU-007 Rev F

Page 4 of 6

Instructions for Use (IFU)
Lab Analog and Coating Mandrel

Separable Fastener Assembly 10PK - Drill Kit Included, Low Profile Lab Analog 10PK, ZimVie
Coating Mandrel 10PK, ZimVie Premium Starter Kit, Omnibut Recharge Kit w/ Tall Spare Parts, Omnibut Recharge Kit w/ POC, Omnibut Separable Fastener Assembly 10-pack
with Drill kit, Omnibut Lab Analog 10PK, Omnibut Coating Mandrel 10PK, Omnibut Coating Mandrel 6PK, Omnibut

ZVLP-SFA10PKDK
ZV-LA10PK ZV-CM10PK
PSK-OA RK-OA RKPOC-OA
SFA10PKDK-OA
LA10PK-OA CM10PK-OA CM6PK-OA

SFT-003
SFT-003 SFT-008 OA-008/OA-009 OA-008 OA-008
OA-008
OA-008 OA-009 OA-009

+D990ZVLP-SFA10PKDK0
+D990ZV-LA10PK0 +D990ZV-CM10PK0
+D990PSK-OA0 +D990RK-OA0 +D990RKPOC-OA0
+D990SFA10PKDK-OA0
+D990LA10PK0 +D990CM10PK0 +D990CM6PK0

Validity: Upon publication of these instructions for use, all previous versions are superseded.
Availability: Some items of Smart Denture Conversions are not available in all countries.
Warranty: Please visit www.SmartDentureConversions.com for the most up to date warranty information.

IFU-007 Rev F

Page 5 of 6

Instructions for Use (IFU)
Lab Analog and Coating Mandrel
Symbols Glossary: The following Symbols may be present on the device labeling or in information accompanying the device. Refer to the device labeling or accompanying information for the applicable symbols.

Manufacturer

Date of Manufacture

Use By Date

Serial Number

Batch Code

Catalog Number

Unique Device Identifier

Medical Device

CE Mark
United Kingdom Conformity Assessment Mark European Representative
Comes Sterilized
Comes Sterilized using Ethylene Oxide Processing Comes Sterilized using Dry Heat Processing
Do Not Reuse

UK Representative United Kingdom Conformity Assessment Mark with Approved Body Number Non-Sterile
Comes Sterilized using Aseptic Processing Comes Sterilized using Irradiation Processing
Do Not Resterilize
Consult Instructions for Use

RX Only

Keep Dry
For Prescription Use Only
Do Not Use if Packaging is Damaged

Keep Away from Sunlight
Caution, Consult Accompanying Documents

IFU-007 Rev F

Page 6 of 6



References