DSC NEO Power Series (HS2016/2032/2064/2128)

PDF preview unavailable. Download the PDF instead.

Uplink DSC Neo Wiring Programming
DSC NEO Power Series (HS2016/2032/2064/2128)
Wiring Uplink's Cellular Communicators and Programming the Panel
CAUTION: · It is advised that an experienced alarm installer programs the panel as further programming may
be required to ensure proper performance and use of the full functionality. · Do not route any wiring over circuit board. · Full panel testing, and signal confirmation, must be completed by the installer. NEW FEATURE: For Uplink Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler. Therefore, wiring the white wire and programming of the status PGM of the panel is optional. IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure.
Wiring the 5530M communicators to DSC NEO
1 of 3

Wiring and Programming Uplink Communicators to DSC NEO
Wiring the 5530M with UDM to DSC NEO for remote upload/download.

Programming the DSC NEO Alarm Panel via the Keypad

Enable Contact ID reporting:

Keypad Display Keypad Entry

Action description

Select:

*85555 To enter in Programming mode

Select:

301

To enter menu" First phone number"

Select: 001

001

To select first phone number

DFFFFF

123456*6*#

Enter actual or non-existing number (any number will do, 123456 is an example) followed by *6* (F in hex).

Select:

383

Enter Communication Options 4.

Comm. Option 4:

2#

Toggle 2 to OFF, to set the programmable account code in 310 to 4 digits.

Select:

310

To enter menu "System account code".

System Account:

000

To enter submenu for the whole system (001, 002... for more partitions)

System Account:

1234

Enter 4-digit account number for CMS identification (1234 is an example)

System Account:

001

To enter submenu for Partition 1

Part.1 Account:

1234# Enter 4-digit account number for CMS identification (1234 is an example)

Select:

311

To enter menu "Reporting".

Select:

001

Go to "Alarm restore" options.

Toggle receiver#1

*#

Press * to select "Y" (yes) ­ "Alarm/Restore" events are reported to telephone number 1

Tamper restore:

002

To go to "Tamper/Tamper restore".

Toggle receiver#1

*#

Press * to select "Y" (yes) ­ "Tamper/Tamper restore" events are reported to telephone number 1.

2 of 3

Opening/Closing
Select: Enter Data: Enter Data: Select: Comms. Enabled:

Wiring and Programming Uplink Communicators

to DSC NEO

003

Go to "Open/Close" events.

*##

Press * to select "Y" (yes) ­ "Open/Close" events are reported to telephone number 1, # to save, # to exit to main menu

350

To enter "Communicator Alarm Format" options.

001

To select phone number 1

03#

03 is for Contact ID.

380

Enter First Communication Options

1##

Toggle 1 to ON, 3 and 4 must be off (DTMF touch-tone dialing, DTMF dialing for all attempts).

Program Keyswitch zone and output:

Keypad Display Select: Select: Zone definitions Zone 1 Momentary KSW Select:
Toggle 1
Toggle Option 1 Select: PGM 1 PGM 1 PGM 1

Keypad Entry

Action Description

*85555 To enter in Programming mode.

001

Enter zone definition menu.

*

Enter Zone 1 definition.

066

To choose Momentary Keyswitch for Zone 1.

##

To exit to main menu.

013

Enter First System Options (to configure Normally Closed Zones).

*

Press * or toggle buttons <> until 1 is OFF (all zones are wired as normally closed circuits with returns to COM terminal).

##

Press ## to exit to main menu.

009

Enter I/O Programming menu.

001

To enter PGM 1 subsection.

115

To program the output to report Armed/Disarmed status.

##

Press ## to exit to main menu.

Programming the DSC NEO Alarm Panel via the Keypad for remote Upload/Download (UDL)

Program the Panel for Upload/Download (UDL):

Display

Keypad Entry

Action Description

Date / Time Enter section Toggle option Enter section Enter Hex Data Enter section Enter Hex Data Enter section Enter Data Enter section Enter Data

*8 + Inst. Code 401
1,3,6# 403
915500# 404
915500# 405 255# 406 001#

Enter programming menu. Default installer code is "5555". First downloading options toggle menu 1 and 3 should be disabled. 6 should be enabled. Press # to exit. DLS downloading access code. Set this field's value to its default. Press # to exit. Panel ID code. Set this field's value to its default. Press # to exit. Double call timer address Disable double call. Number of rings address Set the panel to answer on the first ring.

3 of 3

