Owner's Manual for Goodnature models including: PF-150S, Pomace Feed System, Pomace Feed, Feed System, PF-150S

POMACE FEED SYSTEM OWNER'S MANUAL - Goodnature

IMPORTANT WARNING: To limit electric shocks, personal injury or material damage due to misuse, please read these instructions carefully and follow them ...

IMPORTANT WARNING: To limit electric shocks, personal injury or material damage due to misuse, please read these instructions carefully and follow them ...

GOODNATURE PF-150S (01) PDF MANUAL

PDF preview unavailable. Download the PDF instead.

GOODNATURE PF-150S (01)
POMACE FEED SYSTEM OWNER'S MANUAL
SHOWN WITH EG400

SERIAL #

MANUAL VERSION
1.0

Introduction

IMPORTANT WARNING: To limit electric shocks, personal injury or material damage due to misuse, please read these instructions carefully and follow them strictly. The operation manual should be kept within easy access for all users and read completely by all first-time users of the machine.

MACHINE SPECIFICATIONS
HP: 5.0 | Voltage: 230/460 VAC | Amperage: 15.5/8.0 AMPS

Total Weight:
650 LBS

Weight Crated:
850 LBS

Dimensions:
44"L X 44"W X 56"H

Progressive Cavity Pump Rating:
5 GALLONS PER 100 REVOLUTIONS

RPM:
SET TO 900 RPMS

Hopper Capacity:
STANDARD MODEL 800 LBS, 100 GALLONS.

PF-150S POMACE FEED SYSTEM

02

OWNER'S MANUAL

11

Table of Contents

SECTION 1 SECTION 2 SECTION 2.1 SECTION 2.2 SECTION 3 SECTION 3.1 SECTION 4 SECTION 4.1 SECTION 5 SECTION 5.1 SECTION 6 SECTION 6.1 SECTION 7 SECTION 7.1

Safety Precautions Unpacking Unpacking Parts List Installation Installation Operation Setup Cleaning Machine Cleaning Maintenance Routine Maintenance Useful Information Replacement Parts List

PAGE 04 PAGE 05 PAGE 05 PAGE 05 PAGE 06 PAGE 06 PAGE 07 PAGE 07 PAGE 08 PAGE 08 PAGE 09 PAGE 09 PAGE 10 PAGE 10

PF-150S POMACE FEED SYSTEM

03

OWNER'S MANUAL

11

Section 1: Safety Precautions
IMPORTANT WARNING: To limit electric shocks, personal injury or material damage due to misuse, please read these instructions carefully and follow them strictly. The operation manual should be kept within easy access for all users and read completely by all first time users of the machine.
1.1 SAFETY PRECAUTIONS
Drop SAFETY GLASSES must be worn at all times during operation, cleaning, and servicing of the machine. Drop Never wear loose fitting clothing that can get caught on any moving parts. Drop Long hair must be worn up and tied back or in a hat or hair net. Drop Never insert any foreign items into the PF-150 that weren't supplied by the manufacturer and described in this
manual. Drop Always disconnect power before cleaning or servicing this machine. Drop If any components are damaged or are malfunctioning, discontinue use immediately and get the machine serviced.

PF-150S POMACE FEED SYSTEM

04

OWNER'S MANUAL

11

Section 2: Unpacking

2.1 UNPACKING
UNPACKING EQUIPMENT The equipment has been packaged to reduce the chance of damage during shipment. After unloading the pomace pump from the common carrier, remove the crate, banding and shrink wrap to expose the pump for inspection.
INSPECTION This equipment was carefully inspected both mechanically and electrically before shipment. It should be physically free of marks or scratches and in perfect electrical order upon receipt. The equipment should be inspected for physical damage. Also, the equipment should be inspected for loose or bare wires. If there are any damaged items due to shipping, contact the freight carrier. If any parts are missing, please call our Customer Service Department at (716)855-3325.

2.2 PARTS LIST
Please check that the following parts have been received with your pomace pump.

PART # 19067 11261 18787 11271 14165

QTY 1 1 1 1 1

PART NAME Stainless steel TC reducer Foot switch with 20' cord Stainless steel TC x Barb Adapt 15', 2" Clear F.D.A. hose Stainless hose clamp

Note: Some items are factory assembled. Don't forget to check your packing list for any additional items you may have purchased.

PF-150S POMACE FEED SYSTEM

05

OWNER'S MANUAL

11

Section 3: Installation
IMPORTANT WARNING: All electrical connections should be made by a licensed professional in accordance with state and local codes.
3.1 INSTALLATION
Drop Check for proper voltage before connecting any power to the machine. Drop The voltage and amperage of the power supply depend on the specifications provided by the customer. Information
should be written in on page 2 of this manual. For help finding this information call Goodnature customer service. 716-855-3325. Drop After unpacking and before running, it is important to check that no fasteners became loose during shipping. Check all nuts, bolts, and screws to make sure everything is tight. Drop Be certain that pump is sitting level after installation. Adjustable legs are provided to accomplish this. Drop Foot switch should in a position that allows for ease of use.

PF-150S POMACE FEED SYSTEM

06

OWNER'S MANUAL

11

Section 4: Operation
4.1 START UP
Drop Check to make sure power is disconnected and machine is off before setup.
Drop SAFETY GLASSES must be worn at all times during operation.
Drop Before operating the pump for the first time, fill it with liquid.
Drop CAUTION: DRY OPERATION IS HARMFUL TO THE PUMP. THIS MAY CAUSE DAMAGE TO YOUR STATOR. THE STATOR IS LUBRICATED BY THE LIQUID WHICH IS BEING PUMPED THROUGH THE SYSTEM.
Drop If the liquid being pumped is highly viscous, dilute it before filling the pump. The liquid fill up will lubricate the stator on initial start up.
Drop If the pump is shut down temporarily, enough liquid will remain in the system to provide lubrication upon restarting. It is advisable to maintain the suction piping at higher elevation than the centerline of the pump . This will contain some liquid in the pump at the time of shut down.
Drop After the pump has been filled with liquid, check the direction of the pump rotation by momentarily starting and stopping the drive. See nameplate for correct rotation.

PF-150S POMACE FEED SYSTEM

07

OWNER'S MANUAL

11

Section 5: Cleaning
5.1 MACHINE CLEANING
Drop Power Off and Disconnect all power before cleaning.
Drop SAFETY GLASSES must be worn at all times during operation.
Drop Beware of all pinch-points and moving parts.
1 The first step to cleaning is to flush all solids out of the hopper and pump. 2 Direct pump discharge back into the hopper to allow circulation. 3 After all easily-removable debris has been cleaned off, we recommend using a cleanser that will help break down and
remaining particles. "Master Kleen" can be purchased through our customer service, or any similar products can be used. For information on the chemical makeup of "Master Kleen" please contact Goodnature Products customer service (716)-855- 3325. 4 Mix up the cleanser solution as described in the instructions enclosed with the cleanser using hot water. 5 Turn pump "on" to allow solution to circulate for approximately 10 minutes. 6 Flush cleaning solution with clean water. 7 All removed parts can be washed and sanitized by hand in a sink or soaked if desired.

PF-150S POMACE FEED SYSTEM

08

OWNER'S MANUAL

11

Section 6: Maintenance
6.1 ROUTINE MAINTENANCE
Drop Power Off and Disconnect all power before maintenance. Drop SAFETY GLASSES must be worn at all times during operation.
1 Keep machine clean and free of any foreign objects. 2 Check all fasteners for tightness and damage. 3 Check the condition and tension of the V-Belt. 4 Check that the belt guard is secure. 5 Check all fasteners for tightness.

PF-150S POMACE FEED SYSTEM

09

OWNER'S MANUAL

11

Section 7: Useful Information

7.1 REPLACEMENT PARTS LIST

PART # 14055 11261 11271 18787 19067 14056 19722 19409 19723 19724 17907

PART NAME Buna Gasket 2" Foot Switch Hose 2" Stainless steel TC x Barb adapt Stainless steel TC reducer Buna Gasket 3" Progressive Cavity Pump (rect flange) Gasket for rectangular flange Gearmotor 5HP 60hz Gearmotor 5HP 50hz Progressive Cavity Pump (round inlet)

PF-150S POMACE FEED SYSTEM

10

OWNER'S MANUAL

11

POMACE FEED SYSTEM


Adobe InDesign CC 2015 (Macintosh) Adobe PDF Library 15.0