Instructions for SUSSEX models including: BMDSRH, CBM, Suba Mixer Diverter System Dress Kit, BMDSRH Suba Mixer Diverter System Dress Kit, Mixer Diverter System Dress Kit, Diverter System Dress Kit, System Dress Kit

BMDSRH - Sussex - Installation Guide


File Info : application/pdf, 2 Pages, 845.54KB

PDF preview unavailable. Download the PDF instead.

5121cbd8f1ed718b3e94983a0707991fc946b3ea SUSSEX SUBA BMDSRH mixer diverter system RH Installation Guide
Suba
Mixer diverter system Dress kit

Product code: CBM

Product code

BMDSRH

Mixer diverter system

1
Stud Face Finished
Wall Surface
Apply Silicone

NOGGING Masterfit

80 mm Backplate

Handle Body

Apply Silicone

Set Screw

2
NOGGING Masterfit

Stud Face Finished
Wall Surface Apply Silicone
80 mm Backplate

Handle Body

Apply Silicone

Set Screw

Mixer dress kit
- Remove Mixer protective cover. - Using silicon, seal the wall surface around the Mixer. - Apply a small amount of silicon to the rear of the backplate prior to mounting onto the wall. - Fit the handle body onto the Mixer Cartridge Lever ensuring the Handle is fully engaged. - Secure the Handle Body by tightening the Set screw using the Allen Key provided (tighten well).
Diverter dress kit
- Remove Mixer protective cover. - Using silicone, seal the wall surface around the Diverter. - Apply a small amount of silicone to the rear of the backplate prior to mounting onto the wall. - Fit the Handle Body onto the Diver ter Adapter, ensure the Handle is fully engaged. - Secure the Handle Body by tightening the Set screw using the Allen Key provided (tighten well). To complete the installation, operate the Mixer(s) checking the flow of both hot and cold water from Outlet. Check all fittings and fixtures for water leaks.

sussextaps.com.au

AS/NZS 3718:2005 LIC. 20081
Tapware is to be installed by a Licensed Plumber in accordance with AS/NZS 3500:2003 Recommended working water pressure 300-500 kpa. Maximum water temperature is 65 deg.c
Copyright © Sussex Taps.

Suba
Mixer diverter system Rough in

Product code: CBM

Product code

BMDSRH

Mixer diverter system

1 Vi ew f ro m ab ov e

This
Outlet Side 1 UP

Masterfit

70
Diverter
Min. 8mm

NOGGING
Mixer

90

30-32mm

Stud face

Wall Covering Max. 30mm

Dress Ring

Back Plate

Handle Body
No te: Th e di ve rt er i s of t he d ial ty pe , ro ta te h andl e to d irec t

Outlet 1

Pipe Connections

Diverter

Mixer

Cold

Outlet 2

Hot

Rough in plumbing
- Prior to installing, calculate the finished wall thickness, maximum is 30mm thick, contact manufacturer for further options.
- If Wall thickness is greater than 30mm, contact manufacturer for further options. - Prepare a Nogging to be fixed parallel between the Wall Studs. - The Nogging must be fitted to enable the base of the Masterfit to be 30-32mm back from the Stud Face. - The Masterfit will be marked "This side Up" to indicate orientation. - Using the screws (x4) provided, mount the Masterfit to the Nogging. Ensure the Masterfit is level and square.
Pipe connections
- The Hot and Cold ports are marked on the Masterfit. (Mixers have individual Hot/Cold inlet ports). - Flush all water feed lines. All lines must be free from any dirt and debris before connecting to the Masterfit. - Connect Hot and Cold lines to the corresponding 1/2" BSP ports of the Masterfit. (see Drawing) - Do not remove any factory fitted pressure plugs or Fixings. - Once all water connections are made, check Hot/Cold water flow by operating the Mixer Cartridge. - Check all fittings and fixtures for leaks. - Leave the Mixer(s) in the closed position and replace the Mixer protective cover. - Store the Dress Kit in a safe place until required (see Dress Finishing Guide)
Plumber note
- On-site high pressure line testing must be conducted with the Mixer in the closed position. (STATIC TEST ONLY) - Under no circumstances is the Mixer to be opened when exceeding the maximum stated water pressure. - At the completion of the testing, do not relieve any high pressure by opening the Mixer. - Exposing the internals of the Mixer Cartridge to higher than specified water pressures, will void the