User Manual for CASAMBI models including: LINE 5CV 5 Channel Output Dimmer LED, LINE 5CV, 5 Channel Output Dimmer LED, Output Dimmer LED, Dimmer LED, LED
Casambi 5-Channel RGB TW LED Dimmer ~ LINE-5CV-CASAMBI
Slimline 5-Channel RGB TW LED Dimmer with Casambi ~ Model LINE-5CV-CAS – Bricodex
File Info : application/pdf, 10 Pages, 1.57MB
DocumentDocumentLI NE 5CV CA S A MBI Dev ice Manual Made in Italy F EA T UR ES DIMMER LED CAS AMBI Power S upply : 12- 24- 48 V dc Voltag e Output for strip LED and LED module W HITE , MONOCOLOR , DYNAMIC W HITE, R GB, R GB+ W , R GB+ W W and R GB+ TW Lig ht Control Command: CAS AMBI APP Local Command: N°2 Button Normally Open Control voltage output R Minimum brig htness lev el: down to 0.8% PW M Modulation Frequency PWM 4000Hz Linear curv e S oft start and soft stop S oft dimming of brig htness Extended temperature range 100% Functional Test PRODUCT DESCRIPTION The LINE - 5C V - CAS AMBI is a 5- channel output dimmer LED, controllable v ia Bluetooth thanks to the Casambi APP or locally throug h two normally open buttons. The dimmer LE D is suitable for driv ing loads such as S trip LE D and LED modules, W hite, monochromatic colour, Dy namic W hite, RGB, RGB+ W, RGB+ WW and RGB+ TW at constant voltage. You can connect a power supply at 12 -24-48 Vdc. The maximum v alue of the output current is equal to 12A. The dimmer LED has the following protections: ov er- power protection, under- power protection, rev erse polarity protection and input fuse protection. The LINE - 5C V - CAS AMBI enables you to make not only simple brig htness adjustments but also more intricate lig hting control systems. This is made possible through the creation of multiple scenarios, animations, timers, daylight controls, and more. The CAS AMBI APP can be downloaded for free from the Apple App S tore and the Goog le Play S tore. For the alway s updated manual, consult our website: www.dalcnet.com or QR Code For the correct functioning of the CAS AMBI APP, consult the forum on the C asambi website: https: //support.casambi.com/support/home DALCNET S .r.l. 36077 Altav illa V icentina ( V I) Italy V ia Lago di Garda, 22 Tel. + 39 0444 1836680 DIS TR IBUTE D BY www.dalcnet.com info@ dalcnet.com Wired 4 S igns US A www.w4Rseuvs. a0.1co/ m0 6 / 2 0 2 3 - Pag. 1 / 1 0 +1 (865) 339 4956 7669 C linton Highway, info@ w4susa.com Powell, Tennessee, 37849 LI NE 5CV CA S A MBI Dev ice Manual PRODUCT CODE CODE LI NE-5CV -CAS AMBI SUPPLY VOLTAGE 12-24-48 VDC LED OUTPUT 5 x 5A (max 12A)1 N° OF CHANNELS 5 Made in Italy TY PE OF COMMA ND APP CAS AMBI N°2 Button N.O. PR OT ECT I ONS O V P Ov er voltage protection2 UV P Under voltage protection2 R V P R ev erse polarity protection2 IFP Input fuse protection2 TY PE OF PROFILES NAME OF PR OFI LE [ Lb9 5x5La ([ in) [ Lb9 TW xTW ([ in) [ Lb9 wD. ([ in) [ Lb9 wD. +W ([ in) [ Lb9 wD. +W +W ([ in) [ Lb9 wD. +TW ([ in) # PROFI LE 25222 25223 25224 25225 25226 25227 DESCRI PTION N°5 LED output channels, fiv e slides to dim the outputs. PWM frequency = 4000Hz. Linear dimming curv e. PWM resolution 1000step. N°2+ 2 LED output channels, two slides to dim the outputs and two slides to vary the Colour Temperature PWM frequency = 4000Hz. Linear dimming curv e. PWM resolution 1000step. N°3 Output channels for R GB LE Ds. PWM frequency = 4000Hz. Linear dimming curv e. PWM resolution 1000step. N°3+ 1 Output channels for LE Ds. R GB and W hite can be dimmed separately . PWM frequency = 4000Hz. Linear dimming curv e. PWM resolution 1000step. N°3+ 2 Output channels for LE Ds. R GB and two white channels can be dimmed separately. PWM frequency = 4000Hz. Linear dimming curv e. PWM resolution 1000step. N°3+ 2 Output channels for LE Ds. R GB and Tunable white loads can be dimmed separately. PWM frequency = 4000Hz. Linear dimming curv e. PWM resolution 1000step. 1 The maximum output current depends on the operating conditions and the ambient temperature of the installation. For the correct config uration, check the maximum deliv erable power in the "Technical S pecifications" section and the "Operating W indow". 2 Protections refer to the control logic of the board. DALCNET S .r.l. 36077 Altav illa V icentina ( V I) Italy V ia Lago di Garda, 22 Tel. + 39 0444 1836680 DIS TR IBUTE D BY www.dalcnet.com info@ dalcnet.com Wired 4 S igns US A www.w4Rseuvs. a0.1co/ m0 6 / 2 0 2 3 - Pag. 2 / 1 0 +1 (865) 339 4956 7669 C linton Highway, info@ w4susa.com Powell, Tennessee, 37849 LI NE 5CV CA S A MBI Dev ice Manual Made in Italy REFERENCE STANDARDS EN 55015 EN 61547 EN 61347-1 EN 61347-2-13 Limits and methods of measurement of radio disturbance characteristics of electrical lig hting and similar equipment E quipment for general lig hting purposes EMC immunity requirement Lamp Controlgear Part 1: General and safety requirement Lamp Controlgear Part 2- 13: Particular requirement for d.c. or a.c. supplied electronic Controlgear for LED modules TECHNICAL S PECIFI CATIONS S upply v oltag e Output v oltag e I nput current Output current3 Nominal pow er Pow er loss in standby mode Type of load4 Dimming curves Dimming range5 Minimum dimming level Dimming method PW M Frequency5 PW M R esolution5 Operating Frequencies5 Maximum output pow er5 S torage temperature Ambient temperature, Ta range3 Type of connector W iring section W ire strip length I P protection g rade Casing material Pack aging units ( pieces/ units) Mechanical dimensions Pack aging dimensions W eight 12 Vdc 24 Vdc 48 Vdc S olid S ize S tranded S ize LI NE 5CV CAS AMBI Min: 10, 8V dc Max : 52, 8V dc = V in Max 12A 5x max 5A 1x max 12A 60W 144W 120W 288W 240W 579W < 0.5W R Linear 0,8 100% 0, 8% ( Linear curve 4kHz) Pulse W idth Modulation "PWM" 4000 Hz 1000 S tep 2402 2483 MHz 7dBm Min: - 40°C Max: 60°C Min: - 10°C Max: 60°C Push- In terminals 0.2 ÷ 1.5mm2 / 24 ÷ 16 AWG 9 ÷ 10 mm I P2 0 Plastic 1pcs 186 x 29 x 21 mm 197 x 34 x 29 mm 71g 3For the full rang e check the "Operating W indow" of product. 4Type ofload:wesis ve and 5/ /5/ / onverter. 5 The parameters are deriv ed from the config uration of the Casambi module. DALCNET S .r.l. 36077 Altav illa V icentina ( V I) Italy V ia Lago di Garda, 22 Tel. + 39 0444 1836680 DIS TR IBUTE D BY www.dalcnet.com info@ dalcnet.com Wired 4 S igns US A www.w4Rseuvs. a0.1co/ m0 6 / 2 0 2 3 - Pag. 3 / 1 0 +1 (865) 339 4956 7669 C linton Highway, info@ w4susa.com Powell, Tennessee, 37849 LI NE 5CV CA S A MBI Dev ice Manual Made in Italy W IRING DIAGR AM Follow the steps below for product installation as shown in the connection diagram: · Connect the positiv e of the LED load to the "L" terminal with the "+ " symbol, instead the neg ativ es of the LED load to the terminals "L1", "L2", "L3", "L4" and "L5" with the "- " sy mbol. · Connect the N.O. push button to the "INPUT 1" and "INPUT 2" terminals with the " " symbol. Be sure not to connect liv e parts to "INPUT" terminals. · Connect a 12- 24- 48 V dc constant voltage S ELV power supply ( depending on the technical characteristics of LED load) to the DC IN terminal block with the "+ " and "- " symbols. Be sure not to use constant current LED Driv er and check that the polarity of the cables is correct. Like any other product with Bluetooth control, be sure not to place the product inside a meta l case or placed near large metal structures. The metal will significantly obstruct the radio signal, which is crucial for the proper functioning of the dev ice. CONNECTI ON SCHEME PR OFI LE: LI NE 5xDI M ( Lin) DI MMER 5xW DALCNET S .r.l. 36077 Altav illa V icentina ( V I) Italy V ia Lago di Garda, 22 Tel. + 39 0444 1836680 DIS TR IBUTE D BY www.dalcnet.com info@ dalcnet.com Wired 4 S igns US A www.w4Rseuvs. a0.1co/ m0 6 / 2 0 2 3 - Pag. 4 / 1 0 +1 (865) 339 4956 7669 C linton Highway, info@ w4susa.com Powell, Tennessee, 37849 LI NE 5CV CA S A MBI Dev ice Manual CONNECTI ON SCHEME PROFI LE: LI NE TW xTW ( Lin) Made in Italy TW+ TW CONNECTI ON SCHEME PR OFI LE: LI NE R GB ( Lin) R GB CONNECTI ON SCHEME PROFI LE: LI NE RGB+ W ( Lin) RGB+ W DALCNET S .r.l. 36077 Altav illa V icentina ( V I) Italy V ia Lago di Garda, 22 Tel. + 39 0444 1836680 DIS TR IBUTE D BY www.dalcnet.com info@ dalcnet.com Wired 4 S igns US A www.w4Rseuvs. a0.1co/ m0 6 / 2 0 2 3 - Pag. 5 / 1 0 +1 (865) 339 4956 7669 C linton Highway, info@ w4susa.com Powell, Tennessee, 37849 LI NE 5CV CA S A MBI Dev ice Manual CONNECTI ON SCHEME PR OFI LE: LI NE R GB+ W + W ( Lin) Made in Italy RGB+ W + W CONNECTI ON SCHEME PR OFI LE: LI NE R GB+ TW ( Lin) RGB+ TW DALCNET S .r.l. 36077 Altav illa V icentina ( V I) Italy V ia Lago di Garda, 22 Tel. + 39 0444 1836680 DIS TR IBUTE D BY www.dalcnet.com info@ dalcnet.com Wired 4 S igns US A www.w4Rseuvs. a0.1co/ m0 6 / 2 0 2 3 - Pag. 6 / 1 0 +1 (865) 339 4956 7669 C linton Highway, info@ w4susa.com Powell, Tennessee, 37849 LI NE 5CV CA S A MBI Dev ice Manual Made in Italy LOCAL COMMANDS FUNCTI ONALI TY N.O. PUS H BUTTON6 N° Button F unction Controls a luminaire C lick T ap to turn a luminaire on or off hold to adj ust Long pressure ( > 1s) luminaire brightness Controls an element C lick Tap to turn a device element on or off hold to Long pressure ( > 1s) adjust the element v alue Control a group C lick Tap to turn a group on or off hold to adjust Long pressure ( > 1s) brig htness 1-2 Control scene C lick Long pressure ( > 1s) Tap to turn a scene on or off hold to adjust scene brig htne s s Control all luminaires C lick Tap to turn all luminaires on or off hold to adjust Long pressure ( > 1s) brig htne s s Cycles scenes C lick Tap to cycle through the list of scenes hold to Long pressure ( > 1s) adjust current scene brightness Activ e/S tandby C lick Tap to switch between two scenes hold to adjust Long pressure ( > 1s) current scene brig htness F or all other functions consult the documentation of the CAS AMBI APP at: https:/ / support.casambi.com/ support/ home UNPAI R DEV I CE FR OM THE CAS A MBI NETW OR K If the dev ice is already connected to a network for which you don't hav e the credentials and you wish to associate it with a new network, please follow the instructions prov ided in the Casambi APP's "Nearby Dev ices" section. Once you hav e selected the unpair function and started the procedure, turn offthe main power of the power supply connected to the LINE - 5CV - CAS AMBI and turn it on ag ain after 1 - 2 seconds. If the main power supply is switched offand on again quickly , unpair may not be done properly . Repeat the unpair sequence by allowing 1 or 2 more seconds to elapse between the moment y ou turn offand re - turn on the main power of the power 7. A second method to unpair the product is to connect an N.O. push button to an "INPUT" terminal of the LINE - 5CV - CAS AMBI and during the decoupling procedure press the button. 6 By default, the N.O. Push button is set as "Control a luminaire" and controls the output of the LINE - 5CV - CAS AMBI. 7 The discharge time of the power supply secondary depends on the construction characteristics of the power supply used. DALCNET S .r.l. 36077 Altav illa V icentina ( V I) Italy V ia Lago di Garda, 22 Tel. + 39 0444 1836680 www.dalcnet.com info@ dalcnet.com Rev . 0 1 / 0 6 / 2 0 2 3 - Pag . 7 / 1 0 DIS TR IBUTE D BY Wired 4 S igns US A +1 (865) 339 4956 info@ w4susa.com www.w4susa.com 7669 C linton Highway, Powell, Tennessee, 37849 LI NE 5CV CA S A MBI Dev ice Manual OPERATING W I NDOW L[ 95 [A ] 14 h t 9wA TLb D W Lb 5 h W S 12 10 8 6 4 2 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 TA [°/ ] Ambient temperature [ Ta] : - prov ides a current up to 12A, with a working temperature rang e of - 10°C ÷ + 60°C . These maximum current v alues can be applied only under proper v entilation conditions. Made in Italy FLI CK ER PER FOR MA NCE Thanks to its 4kHz dimming frequency, the LINE - 5CV CAS AMBI effectiv ely reduces the occurrence of the Flicker phenomenon. Depending on an individual's sensitivity and the nature of their activ ities, flickering can impact one's well- being , ev en if the changes in luminance are beyond the threshold detectable by the human ey e. The graph shows the phenomenon of Flickering in function at the frequency, measured throughout the dimming rang e. The results show the low- risk zone ( yellow) and the noeffect zone ( g reen) . Defined by IEE E 1789 - 20158 8 Institute of E lectrical and E lectronics E ng ineers ( IEE E) . IEE E std 1789: R ecommended Practices for Modulating C urrent in Hig hBrig htness LE Ds for Mitig ating Health R isks to V iewers. DALCNET S .r.l. 36077 Altav illa V icentina ( V I) Italy V ia Lago di Garda, 22 Tel. + 39 0444 1836680 DIS TR IBUTE D BY www.dalcnet.com info@ dalcnet.com Wired 4 S igns US A www.w4Rseuvs. a0.1co/ m0 6 / 2 0 2 3 - Pag. 8 / 1 0 +1 (865) 339 4956 7669 C linton Highway, info@ w4susa.com Powell, Tennessee, 37849 LI NE 5CV CA S A MBI Dev ice Manual DI MMI NG CUR V E Output power [ % ] 100 90 80 70 60 50 40 30 20 10 0 0 Linear 10 20 30 40 50 60 70 80 90 100 Dimming Level [ % ] Made in Italy MECHA NI CAL DI MENS I ONS 0.827" 1.122" 1.132" 0.122" 0.209" 7.33" 0.157" 6.699" DALCNET S .r.l. 36077 Altav illa V icentina ( V I) Italy V ia Lago di Garda, 22 0.204" 0.157" Tel. + 39 0444 1836680 DIS TR IBUTE D BY www.dalcnet.com info@ dalcnet.com Wired 4 S igns US A www.w4Rseuvs. a0.1co/ m0 6 / 2 0 2 3 - Pag. 9 / 1 0 +1 (865) 339 4956 7669 C linton Highway, info@ w4susa.com Powell, Tennessee, 37849 LI NE 5CV CA S A MBI Dev ice Manual Made in Italy TECHNICAL NOTE INS TALLATION · CAUTION: The product may only be connected and installed by a qualified electrician. All applicable regulations, legislation, and building codes must be observed. Incorrect installation of the product can cause irreparable damage to the product and the connected LEDs. · Maintenance must be performed only by a qualified electrician in compliance with current regulations. Pay attention when connecting the LEDs: polarity reversal results in no light output and often damag es the LEDs. · The product is desig ned and intended to operate LED loads only . Powering non- LED loads may push the product outside its specified design limits and is, therefore, not covered by any warranty. Operating conditions of the product may never exceed the specifications as per the product datasheet. · The product must be installed inside a switchgear/controlgear cabinet and/or junction box protection against overv oltage. · The product must be installed in a vertical or horizontal position with the label/top cover facing upwards or vertically . Other positions are not permitted. The bottom position is not permitted ( label/top cover facing down) . · K eep separated 230Vac ( LV) circuits and not S E LV circuit from safety extra low v oltag e ( S E LV) circuit and from any connection with this product. It is absolutely forbitten to connect, for any reason whatsoever, directly or indirectly, the 230Vac mains v oltage to the product ( terminal block of BUS included) . · The product must be dissipated correctly. · The use of the product in harsh env ironments could limit the output power. · For built- in components inside luminaires, the ta ambient temperature range is a guideline given for the optimum operating env ironment. However, integ rator must alway s ensure proper thermal management ( i.e. correct mounting of the d ev ice, air flow etc. ) so that the tc point temperature does not exceed the tc maximum limit in any circumstance. Reliable operation and lifetime is only guaranteed if the maximum tc point temperature is not exceeded under the conditions of use. POWE R S UPPLY · Only use S ELV power supplies with limited current for dev ice power supply, short circuit protection and the power must be dimensioned correctly. In the case of power supplies equipped with g round terminals, it is mandatory to connect ALL protective g round points ( PE= Protection Earth) to a properly and certified protection earth. · The connection cables between the v ery low v oltag e power source and the product must be properly dimensioned and must be insulated from any wiring or part at non- S E LV v oltag e. Use double insulated cables. · Dimension the power of the power supply in relation to the load connected to the device. In case the power supply is ov ersized compared to the maximum absorbed current, insert a protection against over- current between the power supply and the device. C O MMA ND · The leng th of the cables connecting between the local commands ( N.O. Push button or other) and the product must be less than 10m. The cables must be properly dimensioned and must be insulated from any non- S E LV wiring or voltage. It is recommended to use double insulated cables, if deemed appropriate also shielded. · ALL dev ice and control sig nal connected to the local command "N.O. Push button" with symbol, they must not supply any type of v oltage. O UT PUT S · It is recommended a leng th of the connecting cables between the product and the LED module less than 10m. T he cables must be properly dimensioned and must be insulated from any wiring or circuits at v oltage not S E LV. It is recommended to use doubl e insulated cables. In case you want to use connecting cables between the product and the LED module g reater than 10m, the installer must guarantee the correct operation of the system. In any case, the connection between the product and the LED module must not exceed 30m. ONLY CAS AMBI/BLUE TOOTH PRODUCT · W AR NING: For optimal functionality of the Casambi sig nal, do not put the dev ice into metal or aluminium boxes and do not shield the dev ice. As any other Casambi product, should not be placed in a metal enclosure or next to larg e me tal structures. Metal will effectively block all radio signals which are crucial to the operation of the product. W ARNI NGS · To guarantee the best performances and the full use of functions, make sure to download on y our dev ice the last release of CAS AMBI APP. · W henev er CAS AMBI APP requires an upgrade of the profile installed in the LED Dimmers, follow the instruction to do it. This a llows you to stay alway s up to date and benefit of new functions released. · Functionality test are done on all dimmers to ensure the right working . In case the dev ice is still paired to "Dalcnet network", y ou are asked to unpair it by following the instructions on CAS AMBI APP and in paragraph "UNPAIR DE VICE FR OM THE CAS AMBI NE TWOR K ". DALCNET S .r.l. 36077 Altav illa V icentina ( V I) Italy V ia Lago di Garda, 22 Tel. + 39 0444 1836680 DIS TR IBUTE D BY www.dalcnet.com info@ dalcnet.com Wired 4 S igns US A www.wR4esvu. s0a1./co0 m6 / 2 0 2 3 - Pag. 1 0 / 1 0 +1 (865) 339 4956 7669 C linton Highway, info@ w4susa.com Powell, Tennessee, 37849