User Manual for VEVOR models including: CL-850 Aquarium Chiller, CL-850, Aquarium Chiller, Chiller
VEVOR Aquarium Chiller, 110 Gal 416 L, 1/3 HP Hydroponic Water Chiller, Quiet Refrigeration Compressor for Seawater and Fresh Water, Fish Tank Cooling System with Pump/Hose, for Jellyfish, Coral Reef | VEVOR US
File Info : application/pdf, 20 Pages, 2.67MB
DocumentDocumentTechnical Support and E-Warranty Certificate https://www.vevor.com/support WATER CHILLER USER MANUAL MODEL: CL-850 We continue to be committed to provide you tools with competitive price. "Save Half", "Half Price" or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and doses not necessarily mean to cover all categories of tools offered by us. You are kindly reminded to verify carefully when you are placing an order with us if you are actually saving half in comparison with the top major brands. CL-850 Coffee Grinder CL-850 <Picture Only For Reference > NEED HELP? CONTACT US! Have product questions? Need technical support? Please feel free to contact us: CustomerService@vevor.com This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won't inform you again if there are any technology or software updates on our product. -1- PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USING THE EQUIPMENT AND KEEP IT FOR FURTHER REFERENCE Contents . SAFETY PRECAUTIONS . PRODUCT DESCRIPTION . DIMENSION AND SPECIFICATION . INSTALLATION . HOW TO USE . MAINTENANCE . CLEANING . ATTENTIONS IX. CIRCUIT DIAGRAM X. TROUBLE-SHOOTING . Safety precautions WARNINGRead all safety warnings, instructions, illustrations and specifications provided with this electric appliance. Failure to follow all instructions listed below may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference. Improper operation may cause personal injury. WARNING Improper operation may cause damage to the machine. Improper operation may cause others object damage. The symbol indicates that the user should pay high attention to and pay attention to the drawing shows the situation to be noted, and the left figure shows "Be careful of electric shock". Disconnect the chiller when moving from one location to another. Do not use a power supply that does not meet the rated voltage and frequency. The use of non-compliant power supplies can cause fire or electric shock. -2- If the machine emits smoke, odor, motor noise and other abnormal conditions, Please do not use it. It may cause fire or electric shock. Do not disassemble, repair or rectify the machine during use. Doing so may result in fire or electric shock and personal injury. BE CAREFUL Do not damage or arbitrarily change the original power cord, and do not bend, forcibly pull, bind or press the power cord under heavy objects. This will damage the power cord, causing electric leakage fire or electric shock. If the machine is not used for a long time, please unplug the power cord from the socket. If the power cord is damaged, contact your local service center or a qualified electrician to install an appropriate replacement cord to prevent any injury or damage. Never insert fingers, pencils, or any other object through the air inlet when chiller is running. When the power cord is unplugged from the socket, the plug should be unplugged. Do not pull the power cord to forcibly pull the wire, which may cause damage to the wire and lead to leakage or electric shock. Please disconnect the power supply when cleaning. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. FCC information: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)This device may not cause -3- harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation. . PRODUCT DESCRIPTION INTRODUCTION: Many thanks for choosing the VEVOR water chillers. --- with energy-saving, low-noise and excellent durable compressor provided by well-known brands. --- with finned condensor produced under strict quality control procedures and the radiator made with premium aluminum and coated with anti-corrosion paint. --- With corrosion-resistant heat exchanger made of high quality industrial pure titanium, ideal for both fresh and marine water. The chillers are widely used in ornamental aquariums, medical cosmetology, biopharmaceutical, horticulture, soilless cultivation and other fields. FEATURES · Unique and creative design of the space with ABS housing, safe and reliable. · Micro computer controlled and easily operated with the control panel. · High-quality compressor of excellent durability, low-noise and energy efficiency. · Titanium heat exchanger, reliable and corrosion-resistant. · Reserved socket for outside heater, if water heating is needed, plug in a heater and then it is controlled by the inner thermostant. · The air filter prevents the chiller from being affected by dirt accummulation, and the air filter can be removed, assembled and cleaned with ease. · The water inlet and outlet are 360 degree turnable, easy to use. -4- TECHNICAL PARAMETER MODEL POWER VOLT. & FREQ. COOLANT PUMP OUTFLOW REFRIGERATING CAPACITY RECOMMENDED TANK SIZE WEIGHT (KG) SIZE(MM) CARTON DIMENSION(MM) CL-850 1/3HP 115V/60HZ R134A 1200L/H 850W 450L120gal 16.7 350*430*400 495*414*550 PERFROMANCE CURVES Temperature Work time (Min=Minute, H=Hour) CL-850 -5- NOTES: 1.Refrigerating effect will be impacted by ambient temperature, water circulation flow rate, installation position, lighting system, surrounding heat sources, room ventilation, aquarium/reservoir structure, etc. To get the best use of this machine, please strictly follow this instruction manual. 2.Recommended water volume is closely related to the ambient temperature and the required water temperature. When ambient temperature is high (and a low water temperature is required) the water volume should be REDUCED to achieve best performance. PRODUCT STRUCTURE DIAGRAM -6- heater socket28*26*16 Model A B C D1 D2 d E H G F CL-850 42 22 21 16 20 12 29 90 24 18 -7- . DIMENSION Back View View from right side Front View MODEL CL-850 L(mm) 350 Top View DIMENSION W(mm) 430 -8- H1(mm) 400 H2(mm) 500 . INSTALLATION TIPSPlease check the accessories before installation. Installation method: 1.Check the Accessories Box, inside of which there are 2 PVC hoses, 1 water pump, 1 hose clamp, and 1 suction cup. See the Fig.1. Take out the 2 hoses firstly. Fig. 1 2.Go on Check the Accessories Bag. See the Fig.2. Assemble the water inlet and outlet. See the Fig.3. Fig. 2 Fig. 3 3.Fix water inlet and outlet on the chiller. See the Fig.4 and connect to the PVC flexible hoses. See the Fig.5. Fig. 4 Fig. 5 -9- 4.Pick the hose 1 ( the hose with one end connected to the chiller inlet), see the Fig. 5, then connect the other end to the water pump outlet, fasten the hose clamp tight (see the Fig. 6) Pick the hose 2 (the hose with one end connected to the chiller outlet), then insert the other end through the elastic ring of the suction cup, and fix it at proper position inside the aquarium wall (see the Fig.6.) Note: for the water pump installation, please refer to the Water Pump Instruction Manual. Attention: Check the chiller inlet and outlet carefully, DO NOT MISCONNECT. Fig. 5 . HOW TO USE Before using the machine, please check: (1)Power cord is securely plugged into a grounded, correctly rated outlet. Make sure the power voltage and frequency are in accordance with the data specified on the nameplate or in the instruction manual. (2)The water inlet, outlet and hose are connected correctly and firmly, make sure there are - 10 - no leaks or clogs. (3)Keep sufficient clearance between the chiller and its surrounding objects for heat dissipation and convenient maintenance, with at least 30cm clearance around front (air inlet) and sides and 60cm in back (air outlet). If the chiller is to be put in an aquarium cabinet, the cabinet should have enough grilles for air circulation, or to be equipped with an extra small exhaust fan. If the 3 items above are OK, you may begin using your water chiller: (1)Turn on water pump, making sure the Circulating Cooling Water System can run normally without any blockage or leak. (2)Turn on the chiller and use the Control Panel to set desired water temperature. Adjust temperature 1.Plug the chiller into a socket of rated voltage and frequency, turn it on. The power indicator light is on and the LCD shows the current water temperature. Fig.1. 2.Press "SET" to enter the setting. Press to turn up pre-set temperature, and press to turn down pre-set temperature. The starting temperature difference is 2for example, the chiller needs to be set at least 2 lower than the actual water temperature to get it started. The chiller needs to set at least 2 lower The chiller needs to set at least 2 higher than the actual water temperature to cool. than the actual water temperature to heat. Fig.2. Fig.3. - 11 - 3.After setting the temperature, the LCD shows the current water temperature, and the chiller will select cool or heat mode automatically after comparing the set temperature and actual water temperature. If in cool mode, the green indicator blinks in "delayed start" state, after a 3 minutes' delay, the chiller starts chilling, and the green indicator becomes solid. If in heat mode, the heater works without delay and the red indicator turns on (Note: heater not included, it requires the user to insert a heater with a two-pin flat plug). Fig.4. 4.When the chiller works in cool mode, the green indicator turns on. When the water temperature drops to the pre-set temperature, the chiller stops working. If the water temperature rises to meet the starting condition (temperature difference is 2), the chiller enters a 3-minute delay and then starts working automatically. By repeating in this way, the chiller keeps the water temperature stay between pre-set temperature and the temperature + 2. See the Fig. 5. 5.When the chiller works in heat mode, the red indicator turns on. When the water temperature rises to the pre-set temperature, the heater stops working. If the water temperature drops to meet the starting condition (temperature difference is 2), the heater works again. By repeating in this way, the chiller keeps the water temperature stay between pre-set temperature and the temperature - 2. See the Fig. 6. Fig.5. Fig.6. - 12 - . MAINTENANCE 1.Regular maintenance is needed each year. Please power off and unplug before maintaining. 2.Please DO NOT use chemicals such as gasoline, benzene and diluent to wipe the chiller. 3.Control panel and motor must be kept dry. If water or any liquid is found on the chiller, please turn off the power immediately and wipe it off with cloth before restarting. 4.DO NOT operate the chiller if it has a damaged cord or plug, or it is malfunctioning or has been dropped or damaged in any manner. 5.DO NOT attempt to service this unit yourself as opening or removing covers may expose you to dangers or other hazards. Refer servicing to qualified service personnel for service or replacing all electrical parts. 6.If the chiller is not in use for a long time, please unplug the power cord, fully discharge the residual water in the tubes, clean the inlet/outlet and hoses and dry them thoroughly. Put the chiller away at a safe dry place. . CLEANING Step1: Please unplug (important!). See the Fig. 1. - 13 - Fig.1 Step2: Please open the front cover (see the Fig. 2), and then take the air filter out (see the Fig. 3). Fig.2 Fig.3 Step3: To prevent dust accumulation, please clean the air filter in water or with a vacuum cleaner regularly. See the Fig. 4 Fig.4 Note: For optimal refrigerating performance, circulating and filter system, and the air filter should be cleaned at least once every month including hoses, fittings, filter media, titanium tube inside the machine and others, as the dirt accumulation and or clogs would weaken the refrigerating capacity. . ATTENTIONS - 14 - - 15 - - 16 - IX. CIRCUIT DIAGRAM X. TROUBLE-SHOOTING Failures may be caused by improper operation or maintenance. Before sending the defective product for repair, check the troubleshooting table below. Failure Possible cause Possible solution The LCD doesn't display and the machine doesn't work The compressor stops working Refrigerating capacity reduces dramatically or no refrigeration at all after a long time of normal use Bad power connection, blown fuse, or broken circuit High air and water temperature leading to high internal pressure, heat protector or capacitor failure Refrigerant leakage or not enough refrigerant left. Poor heat dissipation, condenser radiator fins blocked by dust. Change fuse, check the power switch, plug. Check if plug in the rated voltage and frequency. Please improve the heat dissipation and air ventilation. Change capacitor or heat protector. Please contact a certificated and licensed technician to check and refill the refrigerant. Improve the heat dissipation and air ventilation. Remove dust accumulation on the air inlet and parts. Reduce the water volume referring to the specifications. - 17 - To calibrate water temperature: 1. Press and hold "SET" for 10 seconds to enter Temp Error Adjustment Function, digital display will show "CA". The displayed There is tolerance 2. Press ""(turn up) or "" (turn down) water temp is between the LCD until the displayed figure equals to the different from the displayed temp and the tolerance intended to eliminate (tolerance actual water temp actual water temp. CA = actual water temp - displayed water temp), adjusting range is +4 to -4. 3. After your adjusting operation has stopped for 10 seconds, the control panel will exit to show the adjusted temperature. Water temp reaching set-up temp, but the unit continues to run Temperature sensor not installed at right Turn off or replace the heating switch; refer to operating instructions to adjust temperature control. Digital display place, or temperature shows "E1", cannot detect sensor failed Check the temperature sensor installation. water temp Note: If any other abnormal conditions occur during normal use, please do not try to dissemble and fix the machine by yourself, take it to your supplier or contact certificated and licensed technicians for repair. Manufacturer: Shenzhen XingRisheng lndustrial Co., Ltd. Address: No. 2, Baolong Road 3, Baolong Avenue, Baolong Industrial Park, Longgang, Shenzhen, Guangdong, China MADE IN CHINA - 18 - TechnicalSupport and E-Warranty Certificate https://www.vevor.com/support