DocumentDocumentblaubergventilation.com.au Turbo EC 150 Mixed-flow inline fans with EC-motors · Sound pressure level LpA at 3 m: 46 · Motor type: EC · Impeller type: Mixed-flow · Casing material: Plastik · Installation in any position Connected air duct size Speed Phases Minimum supply voltage Maximum supply voltage Power supply frequency Rated power Unit current Maximum airflow Rotation speed at 50hz Sound pressure level LpA at 3 m Weight Transported air temperature (max) Transported air temperature (min) Ingress protection rating Unit of measurement mm V V Hz W A m3/h - dB(A) kg ° ° - Turbo EC 150 150 1 1 230 230 50/60 55 0.48 600 46 2.95 55 -25 IPX4 blaubergventilation.com.au blaubergventilation.com.au Dimensions ØD 148 B 216.5 H L 253.5 289 ØD1 187 blaubergventilation.com.au Ecodesign Trademark Model Specific energy consumption (SEC) (kWh/(m2/a)) Type of ventilation unit Type of drive installed Type of heat recovery system Maximum flow rate (m3/h) Electric power input (W) Reference flow rate (m3/s) Reference pressure difference (Pa) Specific power input (SPI) (W/(m3/h)) Control typology Maximum external leakage rates (%) Sound power level (dB(A)) Declared typology The annual electricity consumption (AEC) (kWh/a) The annual heating saved (AHS) (kWh/a) blaubergventilation.com.au Blauberg Turbo EC 150 Cold Average Warm 54.6 A+ 27.5 B 12 E Unidirectional Variable speed None 508 54.3 0.099 50 0.058 Local demand control 2.7 66 RVU UVU Cold Average Warm 31 31 31 Cold Average Warm 5536 2830 1280