Instruction Manual for MEAN WELL models including: MPS-65 Series 65W Single Output Medical Type, MPS-65 Series, 65W Single Output Medical Type, Output Medical Type, Medical Type
specification model mps-65-3.3 mps-65-5 mps-65-7.5 mps-65-12 mps-65-13.5 mps-65-15 mps-65-24 mps-65-27 mps-65-48 dc voltage rated current current range rated power output line regulation load regulation setup, rise time hold up time (typ.) voltage range
File Info : application/pdf, 2 Pages, 96.15KB
DocumentDocument65W Single Output Medical Type MPS-65 series User's Manual Features : Universal AC input / Full range Low leakage current <250A Protections: Short circuit / Overload / Over voltage Cooling by free air convection Medical safety approved (2 x MOPP between primary to secondary) 100% full load burn-in test Fixed switching frequency at 45KHz 3 years warranty EN 60601-1 IEC 60601-1 SPECIFICATION 8 MODEL MPS-65-3.3 MPS-65-5 MPS-65-7.5 MPS-65-12 MPS-65-13.5 MPS-65-15 MPS-65-24 MPS-65-27 MPS-65-48 DC VOLTAGE 3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V RATED CURRENT 12A 12A 8A 5.2A 4.7A 4.2A 2.7A 2.4A 1.35A CURRENT RANGE 0 ~ 15.2A 0 ~ 13.8A 0 ~ 9.6A 0 ~ 6A 0 ~ 5.4A 0 ~ 4.8A 0 ~ 3A 0 ~ 2.7A 0 ~ 1.5A RATED POWER 39.6W 60W 60W 62.4W 63.45W 63W 64.8W 64.8W 64.8W OUTPUT POWER (max.) 72W(+3.3V:50W;+5V:69W)with 18CFM min. Forced air convection OUTPUT RIPPLE & NOISE (max.) Note.2 80mVp-p 100mVp-p VOLTAGE ADJ. RANGE 2.97 ~ 3.63V 4.5 ~ 5.5V VOLTAGE TOLERANCE Note.3 ±3.0% ±3.0% LINE REGULATION ±1.0% ±1.0% LOAD REGULATION ±3.0% ±3.0% 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 6.75 ~ 8.25V 10.8 ~ 13.2V 12.2 ~ 14.85V 13.5 ~ 16.5V 21.6 ~ 26.4V 24.3 ~ 29.7V 43.2 ~ 52.8V ±3.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±3.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% ±2.0% SETUP, RISE TIME 800ms, 30ms/230VAC 800ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 50ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz INPUT EFFICIENCY(Typ.) AC CURRENT (Typ.) 66% 74% 76% 77% 78% 79% 80% 80% 1.6A/115VAC 0.9A/230VAC INRUSH CURRENT (Typ.) COLD START 17A/115VAC 40A/230VAC LEAKAGE CURRENT Note.7 Earth leakage current < 250A/264VAC , Touch current < 60A/264VAC OVERLOAD PROTECTION OVER VOLTAGE 73 ~ 105W (3.3V:51 ~ 75W)(5V:70 ~ 105W) rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 3.8 ~ 4.46V 5.75 ~ 6.75V 8.63 ~ 10.1V 13.8 ~ 16.2V 15.5 ~ 18.2V 17.25 ~ 20.25V 27.6 ~ 32.4V 31 ~ 36.45V Protection type : Hiccup mode, recovers automatically after fault condition is removed WORKING TEMP. -10 ~ +60 (Refer to "Derating Curve") 80% 55.2 ~ 64.8V WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS 20 ~ 90% RH non-condensing -20 ~ +85, 10 ~ 95% RH ±0.04%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved SAFETY & EMC (Note 4) ISOLATION LEVEL WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN60601-1-2, medical level, criteria A 359.7Khrs min. MIL-HDBK-217F (25) OTHERS NOTE DIMENSION 127*76*42mm (L*W*H) PACKING 0.23Kg; 54pcs/14.6Kg/1.28CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Mounting holes M1 and M2 should be grounded for EMI purposes. 6. Heat Sink HS1,HS2 can not be shorted. 7. Touch current was measured from primary input to DC output. Product Liability DisclaimerFor detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:MPS-65-SPEC 2021-09-15 65W Single Output Medical Type MPS-65 series Mechanical Specification M1 5.6 127 115.8 5.6 HS1 Unit:mm 64.8 76 FS1 AC FUSE T2A/250V 1 HS2 2 CN1 FS2 AC FUSE T2A/250V CN2 1 2 3 4 5 6 SVR1 LED 4- 3.8 42 3 max. AC Input Connector (CN1) : Molex 5277-02 or equivalent Pin No. Assignment Mating Housing Terminal 1 AC/L Molex 5195 Molex 5194 2 AC/N or equivalent or equivalent Block Diagram I/P EMI FILTER RECTIFIERS & FILTER POWER SWITCHING DC Output Connector (CN2) : Molex 5273-06 or equivalent Pin No. Assignment Mating Housing Terminal 1,2,3 +V 4,5,6 -V Molex 5195 or equivalent Molex 5194 or equivalent : Grounding Required 1.HS1,HS2 cannot be shorted 2.M1 is safety ground RECTIFIERS & FILTER fosc : 45KHz +V -V FG Derating Curve O.L.P. PWM CONTROL DETECTION CIRCUIT O.V.P. Static Characteristics 100 Others 80 60 3.3V,5V 40 20 -10 0 10 20 30 40 50 60 (HORIZONTAL) AMBIENT TEMPERATURE () 100 90 80 70 60 50 40 90 100 110 135 155 INPUT VOLTAGE (V) 60Hz 230 264 File Name:MPS-65-SPEC 2021-09-15 LOAD (%) LOAD(%)