Installation Guide for PHILIPS models including: BRP490, BRP490L, BRP490 BRP490L RoadFlair Eco, BRP490 RoadFlair Eco, BRP490L RoadFlair Eco, RoadFlair Eco, RoadFlair
1 day ago — 50/60Hz. 8-12m. 444170265491. Product Size. 产品尺寸. BRP490. BRP490L. H. Signify (China) Investment Co., Ltd. Building No. 9, Lane 888 Tianlin Road,. Minhang ...
RoadFlair ECO | BRP490 | Philips lighting
File Info : application/pdf, 6 Pages, 2.16MB
DocumentDocumentRoadFlair Eco BRP490 / 490L Mounting instruction / 444170265491 ta35 GB 7000 IEC 60598 IP66 IK08 220-240V 50/60Hz 8-12m Class I Type BRP490 12LED400(WW,722,727,R,P5) LEDs 12 CCT Power/W(max.) 30 BRP490 14LED450(WW,722,727,R,P5) 14 40 BRP490 18LED425(WW,722,727,R,P5) 18 50 2200K BRP490 22LED475(WW,722,727,R,P5) 22 2700K 70 3000K BRP490L 28LED450(WW,722,727,R,P5) 28 4000K 5700K 80 BRP490L 32LED450(WW,722,727,R,P5) 32 90 BRP490L 36LED450(WW,722,727,R,P5) 36 100 BRP490L 40LED475(WW,722,727,R,P5) 40 120 This product contains a light source of energy efficiency class: B Wind force(m2) 0.045 0.07 Weight(Kg) 1.8 2.8 Factory Description BRP490x LEDaaa/bb cccc dddd eee fff gg. x denotes housing type, could be L/nil, L denotes Large Housing; aaa denotes rated lumen output. could be 45, 75 to181, E.g. aaa=181. The rated lumen output 18100lm; bb denotes color temperature, CW=Cool White, NW=Neutral White, WW=Warm White, 727=CRI70&2700K, 722=CRI70&2200K; ccc denotes rated system power, could be 30, 31,120, E.g. ccc=120, the rated system power is 120W; ddd denotes Lens type: DW2n/DW2nR/nil; eee denotes driver type, PSA/nil; fff denotes SPD, SP1/nil, SP1 means 10KV SPD, SP5 means 15KV SPD, nil means blank; gg denotes Socket, P5/nil, P5 means NEMA socket and shorting Cap, nil means blank; *Maximum Number of Luminaire on MCB 16A Type C 1.6 Time of type B for MCB 16A The electrical circuit Touch current or protective conductor current (in some cases referred to Earth Leakage Current) may be greatly dependent upon electrical supply cables used such as its rating and length, proper connection of electrical supply cables to luminaires and wiring connection topology of luminaires to the supply electrical circuit amongst other site conditions. *Maximum Number of Luminaire on MCB 16A Type B 18 18 18 18 9 9 9 9 Alternative Program Driver Inrush Current 51A/25us@230V 51A/25us@230V 51A/25us@230V 51A/25us@230V 79A/122us@230V 79A/122us@230V 79A/122us@230V 78A/174us@230V Driver Description PLS 65W 0.7-1.05A 1-10V DS PLS 65W 0.7-1.05A 1-10V DS PLS 65W 0.7-1.05A 1-10V DS PLS 65W 0.7-1.05A 1-10V DS XI EP 100W 0.7-1.05A 1-10V WL Y XI EP 100W 0.7-1.05A 1-10V WL Y XI EP 100W 0.7-1.05A 1-10V WL Y XI EP 150W 0.7-1.05A 1-10V WL Y Model BRP490 12LED400 BRP490 14LED450 BRP490 18LED425 BRP490 22LED475 BRP490L 28LED450 BRP490L 32LED450 BRP490L 36LED450 BRP490L 40LED475 Product Size Standard Version System Ready Unit: mm : mm BRP490 BRP490L * 0.3 / Luminaire with 0.3M cable(s) Signify (China) Investment Co., Ltd. Building No. 9, Lane 888 Tianlin Road, Minhang District, Shanghai, China Postal code: 200233 H Data subject to change without notice. () 888 9 200233 1 of 6 ( P5 NEMA ) Shorting cap (only for P5 NEMA version) 1. Shall be fixed by a qualified electrician. 2. 10° Shall be fixed clockwise until the end. Rotation angle is about 10°. 3. 3 Shorting cap provided with the luminaire is rated for 3 years' service life. 4. 3 Shorting cap should be replaced with intended device or new shorting cap within 3 years. ( DW2nR ) Glare Ring in black (Only for DW2nR) Black Glare Ring / Note1. Signify IP66 Must use Signify suggested shorting cap to ensure IP66. 2. Node Node installation refer to their MI. / Safety String 1. 2. Use a hex wrench to remove the screws from the luminaire. S=4 Install the safety string and tighten screw. Secure end of safety string L=0.7m 1. Customer can install safety string as required. 2. Safety string is not provided by Signify, need to be prepared by user. 3. SUS304 2 Material spec of safety string should be robust and not less than SUS304 2. 4. 0.7 Safety String length should expose 0.7m. I Connect the power cord & signal cable On/Off Type Wiring IP66 / IP66 waterproof Box 1-10V 1-10V Control Type Wiring 1-10V+ Brown 1-10V + IP66 / IP66 waterproof Box L Brown L Luminaire Side N Blue N 1-10VBlue 1-10V - Connect to power supply Luminaire Side L Brown L Connect to signal cable Connect to power supply GND Yellow-Green GND N Blue N GND Yellow-Green GND ! : Notice: Correct connection for polarities. ! --: 60245 IEC57(YZW) 3x1.0mm2 Power supply cable: 60245 IEC57(YZW) 3x1.0mm2 --: 60245 IEC57(YZW) 2x1.0mm2 Signal cable: 60245 IEC57(YZW) 2x1.0mm2 IP66 Recommended to use waterproof box IP66, the dimension value must be below the pole arm inner diameter value, to ensure it go through the pole arm. Waterproof box is not provided by Signify. II Install the luminaire on the pole. 2-M8 Torque: 17N.m : 17N.m : 0-15 : 40-60mm The angle of pole: 0-15 degree Pole diameter: 40-60mm 2 of 6 0~15° Surge protection device replacement / 1. Need to remove the luminaire from the pole. 2. Open the gear cover. ! M4 (4X / 6X) Max. torque 2N.m : 2N.m ! Need to switch off the power supply before the operation. 3. Replace damaged SPD unit. 4mm ! I Class I level luminaire cannot remove this earth wire 2 1 After replacing the SPD, repeat steps 2 and 1 to restore the luminaire and light up the luminaire. 1. The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEEE electrical regulations or the national requirements. ! IEE 2. Switch off main power supply before Installation, maintenance and any operation. 3. The connection of power cable on luminaire is type Y. If the external cable or cord of the luminaire is damaged, the cable should be replaced by the manufacturer or its service agent or a similar qualified person to avoid danger. Y 4. The light source and/or control gear contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person. / 5. Earthing contact to customer end on luminaire must be connected by installer, including whole use process that the earthing contact is always reliably linked to earth ground. 6. The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 2.7m is not expected. 2.7 7. The insulation between LV and control circuit is basic insulation. LV 8. The luminaire should avoid storage and usage in such a surrounding or an occasion that is with corrosion or hazardous gases like sulfide, halide, phthalate and so on. 9. The PC material cannot be used in such a ambience that is with ethylamine, tetra-dichloroethylene, which is corrosion or hazardous to PC material and so on. PC PC 10. For periodically cleaning maintenance of luminaire which PC material is exposed to outside, Acid solution or alkali solution cannot be used as a cleaning solution to wash outside surface of luminaire. PC 11. Manufacturer is not responsible to improper use, change and modification structure on luminaire. Any damage or unsafety losses caused by these factors under not to be allowed, manufacturer do not take any responsibility for this situation. 12. All materials used in luminaire must be compliance to RoHS as the table. 3 of 6 ©2020 Signify Holding All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights. Signify Holding The Netherlands Please inform yourself about the local waste disposal, separation and collection system for electrical and electronic products and packaging. Please act according to your local rules and do not dispose your old product and packaging with your normal household waste. The correct disposal of the packaging, your product and/or batteries will help prevent potential negative consequences for the environment and human health. Batteries should be disposed separately from the municipal waste stream via designated collection facilities. When disposing a product that contains non-user replaceable batteries, the non-user replaceable batteries shall be removed by a professional. / EN arning 1. The luminaire shall be installed by a qualified electrican and ired in accordance ith the latest electrical regulations or ! the national requirements. 2. Turn po er off before inspection installation or removal. . The light source and/or control gear contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person. . efer to technical datasheet for additional electrical properties to ensure safe installation. . uminaire installed must not be in contact ith combustible materials. . nsure po er supply cables / are connected correctly before s itching on. aintenance 1. nsure po er supply is s itched off before attempting any maintenance or . 2. eriodic cleaning of the luminaire optical lens cover ill ensure ma imum optical efficiency. . uminaire optical lens cover shall be cleaned ith clean ater and non abrasive soap cleaner or detergent solution. aution The uminaire must be used ithin the applicable product specifications installation instructions and environmental conditions for storage operations according to application guidelines provided by ignify for product arranty to be valid. VN AR Lu ý Tt ngun in trc khi kim tra, lp t hay tháo ri B èn cn c lp t theo hng dn bi th in lành ngh Vui lòng xem các thông s k thut v in m bo lp t an toàn Sn phm phi do k thut viên lành ngh lp t & u ni dây theo tiêu chun in mi nht ca IEE hoc theo qui nh ca nc s ti Không c lp b èn trên b mt s dng vt liu d cháy thông thng Tránh v trí cáp ngun gn các linh kin có nhit cao m bo ni dây úng duy trì phân cc Signify B.V. sn xut tt c b iu khin s dng trong b èn này B èn này c thit k cho ng dng chiu sáng ngoài tri Bo trì m bo tt ngun in trc khi bo trì Lau chùi nh k mt ngoài ca kính èn m bo quang hiu ti a Mt kính cn c lau chùi bng nc sch và các loi xà phòng hay dung dch ty ra không n mòn Chú ý Vui lòng m bo rng các hng dn lp t và iu kin môi trng lu tr và hot ng c lu gi m bo tính hp l ca sn phm khi cn bo hành. IEEE 4 of 6 TH ID Perhatian 1. Luminer harus diinstal oleh teknisi listrik yang terkualifikasi sesuai dengan regulasi kelistrikan IEE terbaru atau standar nasional 2. Matikan sebelum inspeksi, pemasangan atau pemindahan 3. Sumber cahaya dari luminer ini tidak dapat diganti; saat sumber cahaya mencapai masa akhir, luminer secara keseluruhan harus diganti 4. Mohon merujuk pada lembar data teknis untuk tambahan fituk elektrik yang dibutuhkan untuk memastikan keamanan pemasangan 5. Luminer yang dipasang tidak boleh memiliki kontak dengan material yang mudah terbakar/ panas 6. Pastikan suplai kabel (L-N/ L-N-E) terpasang dengan benar sebelum menyalakan perangkat. Perawatan 1. Pastikan suplai listrik mati sebelum melakukan perawatan 2. Perawatan secara berkala pada penutup lensa optikal akan memastikan efisiensi optikal yang optimal 3. Penutup lensa optikal harus dibersihkan dengan air bersih dan sabun atau pembersih non-abrasif. Perhatian Luminer harus dipasang sesuai dengan spesifikasi produk, instruksi pemasangan dan kondisi lingkungan untuk penyimpanan & operasional sesuai dengan petunjuk dari Signify Indonesia agar garansi produk dapat berlaku. 5 of 6 Zh h ! ts lighting.philips.ru : " ..", 48, 5656 ., . ( Singify Netherlands B.V., High Tech Campus 48, 5656 AE Eindhoven, The Netherlands) : « », , 141402, , . , . , 25, 16. . 8 10 800 7445 47 75. DDDD < ! s t,/W/< dd lighting.philips.ua : Signify Netherlands B.V. ( .., , 48, 5656 , . , ). : « », : . , 4, 2, . , 03680, ! ts lighting.philips.ru : " ..", 48, 5656 ., : « » . : , 141402, , ., ., 25 , 16 . .: 8 10 800 7445 47 75. 6 of 6