User Guide for FS models including: S3410 Series Switches, S3410 Series, Switches
S3410 - FS.com
Technical - FS.com
File Info : application/pdf, 10 Pages, 595.76KB
DocumentDocumentS3410SS3e4r1i0esSSEwRIiEtcShSeWs SIToCfHtwEaSrSeOUFpTgWraAdReEGUuPiGdeRADE GUIDE S3410 Series Switches Software Upgrade Guide Models: S3410-24TS-P; S3410-48TS-P; S3410-10TF-P www.fs.com 1 S3410 SERIES SWITCHES SOFTWARE UPGRADE GUIDE Contents 1. Explanation.......................................................................................................................................................................1 2. Upgrade File..................................................................................................................................................................... 1 3. TFTP Server Setup............................................................................................................................................................1 4. Upgrade Steps.................................................................................................................................................................. 2 4.1 Upgrade Under the Main Program.............................................................................................................................................................. 2 4.1.1 Network Topology......................................................................................................................................................................................... 2 4.1.2 Configuration Steps....................................................................................................................................................................................... 2 4.1.3 Functional Verification...................................................................................................................................................................................3 4.2 U Disk Upgrade.............................................................................................................................................................................................. 4 4.2.1 Network Topology......................................................................................................................................................................................... 4 4.2.2 Configuration Steps....................................................................................................................................................................................... 4 4.2.3 Functional Verification...................................................................................................................................................................................5 4.3 Upgrade in Uboot Mode............................................................................................................................................................................... 6 4.3.1 Network Topology......................................................................................................................................................................................... 6 4.3.2 Configuration Steps....................................................................................................................................................................................... 6 4.3.3 Functional Verification...................................................................................................................................................................................8 www.fs.com I S3410 SERIES SWITCHES SOFTWARE UPGRADE GUIDE 1. Explanation When new features are added or the original performance needs to be optimized and the current running version is lagging behind, the device needs to be upgraded. At this time, you need to load the higher version of the system software, upgrade through the CLI interface, WEB interface, and restart the device to achieve. Precautions In the process of upgrading and downgrading, please pay attention to the prompt information output during the operation. If it fails, please save the log information and contact FS Network Technical Support. During the upgrade and downgrade process, there will be a prompt message not allowing restart. Once such a prompt message appears, please do not power off, do not reset the system, and do not insert or remove any modules. After the upgrade and downgrade are complete, run the show version command to view the current version number of the device to confirm the upgrade is successful. 2. Upgrade File To upgrade the device to this version or downgrade to this version, you need to use the following upgrade file. Applicable Products S3410-24TS-P Upgrade File File Description File Size MD5 Value Upgrade File S3410-24TS-P_FSOS11.4(1)B70P1_install.bin System installation package 75402076 bytes 820d6326f9228ad8067b794e063db015 3. TFTP Server Setup Use software TFTP on local PC Specify the folder where the version file is located and the IP address of the TFTP server www.fs.com 1 S3410 SERIES SWITCHES SOFTWARE UPGRADE GUIDE 4. Upgrade Steps 4.1 Upgrade Under the Main Program 4.1.1 Network Topology 4.1.2 Configuration Steps Set the IP address of the console port of the switch S3410-24TS-P>enable ------->Enter privileged mode S3410-24TS-P#configure terminal ------->Enter global configuration mode S3410-24TS-P(config)#interface vlan 1 ------->Enter vlan 1 interface S3410-24TS-P(config-if)#ip address 192.168.1.200 255.255.255.0 ------->Set management ip on vlan 1 interface S3410-24TS-P(config-if)#exit ------->Return to global configuration mode Set the computer IP address, and confirm that the computer can ping the switch, and the switch can also ping the computer C:\Users\FS>ping 192.168.1.200 Ping 192.168.1.200 with 32 bytes of data: Reply from 192.168.1.200: Byte=32 Time=3ms TTL=64 Reply from 192.168.1.200: Byte=32 Time=2ms TTL=64 Reply from 192.168.1.200: Byte=32 Time=2ms TTL=64 Reply from 192.168.1.200: Byte=32 Time=2ms TTL=64 Ping statistics of 192.168.1.200: Packet: Sent = 4, Received = 4, Lost = 0 (0% lost), Estimated time of round trip (in milliseconds): Shortest = 2ms, longest = 3ms, average = 2ms S3410-24TS-P#ping 192.168.1.100 Sending 5, 100-byte ICMP Echoes to 192.168.1.100, timeout is 2 seconds: < press Ctrl+C to break > !!!!! Success rate is 100 percent (5/5), round-trip min/avg/max = 1/1/2 ms. NOTE: The firewall function of the computer must be turned off, and the anti-virus software must be exited, otherwise the upgrade may not succeed Put the tftp software (tftp software can be downloaded from the Internet) and the new software version into the same directory. Start the tftp tool and execute the following commands on the switch, the device will be automatically upgraded: S3410-24TS-P#upgrade download tftp://192.168.1.100/S3410-24TS-P_FSOS11.4(1)B70P1_install.bin Upgrade the device must be auto-reset after finish, are you sure upgrading now?[Y/N]y www.fs.com 2 S3410 SERIES SWITCHES SOFTWARE UPGRADE GUIDE The following prompt indicates that the upgrade was successful: *Sep 19 12:37:24: %7: [Slot 0]:Upgrade processing is 10% *Sep 19 12:37:39: %7: *Sep 19 12:37:39: %7: [Slot 0]:Upgrade processing is 20% *Sep 19 12:37:39: %7: *Sep 19 12:37:40: %7: [Slot 0]:Upgrade processing is 30% *Sep 19 12:37:40: %7: *Sep 19 12:37:40: %7: [Slot 0]:Upgrade processing is 40% *Sep 19 12:37:40: %7: *Sep 19 12:37:40: %7: [Slot 0]:Upgrade processing is 50% *Sep 19 12:37:40: %7: *Sep 19 12:37:40: %7: [Slot 0]:Upgrade processing is 60% *Sep 19 12:37:41: %7: *Sep 19 12:37:41: %7: [Slot 0]:Upgrade processing is 70% Upgrade info [OK] Rootfs version[1.0.0.ca7d092b->1.0.0.99662b17] Reload system to take effect! System is reload%FS_SYS-0-REBOOT ...... Erasing at 0xfe0000 -- 100% complete. OK Erasing Nand... Erasing at 0x4e0000 -- 100% complete. Writing to Nand... done SUCCESS: UPGRADING OK. resetting ... ...... Restart the switch S3410-24TS-P#reload ----->Restart the switch to take effect Reload system?(Y/N) y After restart, confirm whether the switch is successfully upgraded 4.1.3 Functional Verification Confirm whether the version is the upgraded version by show version www.fs.com 3 S3410 SERIES SWITCHES SOFTWARE UPGRADE GUIDE 4.2 U Disk Upgrade 4.2.1 Network Topology 4.2.2 Configuration Steps Set the IP address of the console port of the switch S3410-24TS-P>enable ------->Enter privileged mode S3410-24TS-P#configure terminal ------->Enter global configuration mode S3410-24TS-P(config)#interface vlan 1 ------->Enter vlan 1 interface S3410-24TS-P(config-if)#ip address 192.168.1.200 255.255.255.0 ------->Set management ip on vlan 1 interface S3410-24TS-P(config-if)#exit ------->Return to global configuration mode Set the computer IP address, and confirm that the computer can ping the switch, and the switch can also ping the computer C:\Users\FS>ping 192.168.1.200 Ping 192.168.1.200 with 32 bytes of data: Reply from 192.168.1.200: Byte=32 Time=3ms TTL=64 Reply from 192.168.1.200: Byte=32 Time=2ms TTL=64 Reply from 192.168.1.200: Byte=32 Time=2ms TTL=64 Reply from 192.168.1.200: Byte=32 Time=2ms TTL=64 Ping statistics of 192.168.1.200: Packet: Sent = 4, Received = 4, Lost = 0 (0% lost), Estimated time of round trip (in milliseconds): Shortest = 2ms, longest = 3ms, average = 2ms S3410-24TS-P#ping 192.168.1.100 Sending 5, 100-byte ICMP Echoes to 192.168.1.100, timeout is 2 seconds: < press Ctrl+C to break > !!!!! Success rate is 100 percent (5/5), round-trip min/avg/max = 1/1/2 ms. NOTE: The firewall function of the computer must be turned off, and the anti-virus software must be exited, otherwise the upgrade may not succeed Insert the U disk carrying the installation package into the USB port of the device Log in to the switch and execute the following commands on the switch, the device will be automatically upgraded: S3410-24TS-P#upgrade usb0:S3410-24TS-P_FSOS11.4(1)B70P1_install.bin ------->There is no space between usb0 and the name of the rack package *Sep 19 12:37:24: %7: [Slot 0]:Upgrade processing is 10% www.fs.com 4 S3410 SERIES SWITCHES SOFTWARE UPGRADE GUIDE *Sep 19 12:37:39: %7: *Sep 19 12:37:39: %7: [Slot 0]:Upgrade processing is 20% *Sep 19 12:37:39: %7: *Sep 19 12:37:40: %7: [Slot 0]:Upgrade processing is 30% *Sep 19 12:37:40: %7: *Sep 19 12:37:40: %7: [Slot 0]:Upgrade processing is 40% *Sep 19 12:37:40: %7: *Sep 19 12:37:40: %7: [Slot 0]:Upgrade processing is 50% *Sep 19 12:37:40: %7: *Sep 19 12:37:40: %7: [Slot 0]:Upgrade processing is 60% *Sep 19 12:37:41: %7: *Sep 19 12:37:41: %7: [Slot 0]:Upgrade processing is 70% Upgrade info [OK] Rootfs version[1.0.0.ca7d092b->1.0.0.99662b17] Reload system to take effect! System is reload%FS_SYS-0-REBOOT ...... Erasing at 0xfe0000 -- 100% complete. OK Erasing Nand... Erasing at 0x4e0000 -- 100% complete. Writing to Nand... done SUCCESS: UPGRADING OK. resetting ... ...... Restart the switch S3410-24TS-P#reload ------> Restart the switch to take effect Reload system?(Y/N) y After restart, confirm whether the switch is successfully upgraded 4.2.3 Functional Verification Confirm whether the version is the upgraded version by show version www.fs.com 5 S3410 SERIES SWITCHES SOFTWARE UPGRADE GUIDE 4.3 Upgrade in Uboot Mode 4.3.1 Network Topology 4.3.2 Configuration Steps Restart the device When the Ctrl+C prompt appears, press the CTRL and C keys simultaneously on the keyboard to enter the bootloader menu Boot 1.2.28-0c4a1bf (Feb 09 2017 - 17:14:53) I2C: ready DRAM: 508 MiB NAND: (ONFI), chipsize 512 MiB In: serial Out: serial Err: serial Unlocking L2 Cache ...Done arm_clk=1000MHz, axi_clk=400MHz, apb_clk=100MHz, arm_periph_clk=500MHz SETMAC: Setmac operation was performed at 2020-02-28 15:24:58 (version: 11.0) Press Ctrl+C to enter Boot Menu Net: eth-0 Entering simple UI.... ====== BootLoader Menu("Ctrl+Z" to upper level) ====== TOP menu items. ************************************************ 0. Tftp utilities. 1. XModem utilities. 2. Run main. 3. SetMac utilities. 4. Scattered utilities. 5. Set Module Serial ************************************************ After entering the bootloader menu, click the red reminder below to enter the address configuration menu ====== BootLoader Menu("Ctrl+Z" to upper level) ====== TOP menu items. ************************************************ 0. Tftp utilities. 1. XModem utilities. www.fs.com 6 S3410 SERIES SWITCHES SOFTWARE UPGRADE GUIDE 2. Run main. 3. SetMac utilities. 4. Scattered utilities. 5. Set Module Serial ************************************************ Press a key to run the command: 0 ====== BootLoader Menu("Ctrl+Z" to upper level) ====== Tftp utilities. ************************************************ 0. Upgrade bootloader. 1. Upgrade kernel and rootfs by install package. 2. Down to memory and jump to run. ************************************************ Press a key to run the command: 1 Under the menu, follow the prompts to enter the switch device address, execute the pc address, and the file name to be upgraded Plz enter the Local IP:[]: 192.168.1.200 --------->Switch address Plz enter the Remote IP:[]: 192.168.1.100 -------->PC address Plz enter the Filename:[]: S3410-24TS-P_FSOS11.4(1)B70P1_install.bin -------->Upgrade bin file Follow the prompts to select Y to continue to the next step Determined to upgrade? [Y/N]: Y Upgrading, keep power on and wait please ... Upgrading boot ... After successful upgrade, automatically return to the bootloader menu interface, press ctrl+z to exit the menu item to restart ====== BootLoader Menu("Ctrl+Z" to upper level) ====== Tftp utilities. ************************************************ 0. Upgrade bootloader. 1. Upgrade kernel and rootfs by install package. 2. Down to memory and jump to run. ************************************************ Press a key to run the command: ====== BootLoader Menu("Ctrl+Z" to upper level) ====== TOP menu items. ************************************************ 0. Tftp utilities. 1. XModem utilities. 2. Run main. 3. SetMac utilities. 4. Scattered utilities. 5. Set Module Serial www.fs.com 7 S3410 SERIES SWITCHES SOFTWARE UPGRADE GUIDE ************************************************ Press a key to run the command: 2 Unmounting UBIFS volume kernel! 4.3.3 Functional Verification Confirm whether the version is the upgraded version by show version www.fs.com 8