ANSULT LED Ceiling Luminaire
Product Code: 019744
Safety Instructions
- ? Only intended for indoor use.
- Ensure the power supply is disconnected before installation.
- Check that the rated voltage corresponds to the mains supply voltage.
- Do not connect the light to the mains while it is still in the pack.
- Check that all electrical and connection cables comply with applicable regulations and are connected according to instructions.
- Never overload the mains; this can result in fire or electric shock.
- Keep out of the reach of children.
- Do not store the light in damp, very cold, or hot places, as this can damage the electronics.
- The electronics are sensitive to knocks and blows; avoid dropping the unit.
- Never attempt to replace damaged power cords yourself.
- The light source should only be replaced by an authorized service center or qualified personnel.
- The product is not dimmable.
- Be careful not to damage concealed wires during installation.
WARNING!
New installations and extensions to existing systems must be carried out by an authorized electrician. If you have the necessary knowledge, you may replace switches, sockets, and fit plugs, extension cords, and lamp holders. Otherwise, contact an electrician. Incorrect installation can result in fatal injury and fire risk.
Symbols
- ? Read the instructions.
- ? Only intended for indoor use.
- ⚡ Risk of electric shock.
- ⚙️ Driver replaceable by qualified personnel.
- ? Light source replaceable by qualified personnel.
- ✅ Approved as per applicable directives.
- ♻️ Recycle discarded product in accordance with local regulations.
Technical Data
Parameter | Value |
---|---|
Rated voltage | 230 V ~ 50 Hz |
Output | 23 W |
Luminous flux | 2200 lm |
Colour temperature | 2700 K |
Colour rendering index | 80 |
Life span | 25000 h |
Off/On cycles | 25000 times |
Energy class | E |
Dimmable | No |
Protection rating | IP20 |
Diffusion angle | 120° |
Size | L 600 x W 160 x H 50 mm |
Installation Instructions
Refer to the figures for installation steps:
Step 1: Power Disconnection
Ensure the power supply is disconnected by switching off the main power (illustrated by a hand turning off a switch).
Step 2: Luminaire Preparation
Prepare the luminaire for mounting. This may involve accessing mounting points or removing a cover (illustrated by the luminaire body and screws).
Step 3: Ceiling Mounting
Mount the luminaire body to the ceiling. An arrow indicates the direction of attachment.
Step 4: Marking Mounting Holes
Mark and drill mounting holes on the ceiling according to the specified dimensions. Dimensions are provided for different luminaire lengths (e.g., L60: X=515mm, Y=106mm; L90: X=775mm, Y=106mm; L120: X=920mm, Y=106mm).
Step 5: Electrical Connections
Connect the electrical wires: Live (L), Neutral (N), and Earth. Ensure wire thickness is between 0.75-1.5 mm². The diagram shows connection terminals.
Step 6: Attaching the Cover
Attach the luminaire cover to the main body. An arrow indicates the direction of attachment.
Step 7: Final Power On
Complete the installation and switch on the power supply (illustrated by a hand turning on a switch).
Additional Views (Steps 8-13)
Steps 8-13 provide detailed views of the luminaire's internal structure, components, mounting brackets, and an exploded assembly view, illustrating the design and assembly process.