LOOKING FOR CRYSTAL CLEAR PICTURE AND SOUND?

MAX® 5300-PM

HOME THEATER POWER MANAGEMENT

Key Features

Image Description: The front of the Panamax M5300-PM unit is shown, featuring a digital voltmeter display, power button, and various outlets. The text "MAX 5300-PM" is displayed vertically. A US Patent number (1,245,470) is visible, along with warranty information.

Key Benefits

1. Improves Picture and Sound Quality

Level 4 Power Cleaning and Filtration eliminates common symptoms of contaminated power (including loss of detail, pops, hisses, hums and visual artifacts) and allows your A/V equipment to perform up to its full capability.

2. Monitors Incoming Line Voltage and Provides a Visual Indication of Power Level

Panamax's patent pending AVM™ circuitry continuously monitors the incoming power as displayed on the digital voltmeter. In case of an undervoltage or an overvoltage, a flashing red lightning bolt ⚡ will be displayed in the voltmeter, and power to the connected equipment is automatically turned off if either of these conditions is detected. When voltage returns to a safe level, power to the equipment is automatically reconnected.

3. Reduces Cross-Contamination Between Components

The M5300-PM is designed to provide noise isolation between 5 isolated outlet banks (including 1 bank with 2 high current outlets) so that any noise created by an A/V component cannot contaminate the power going to equipment plugged into another outlet bank.

Back Panel Features

Image Description: The rear panel of the Panamax M5300-PM is illustrated, detailing 12 connection and protection points:

Specifications

General
Dimensions 17 in. W x 12.75 in. D x 3.5 in H, (4.1 in. Including feet)
Weight 14 lbs.
AC Power
Line Voltage 120V, 60Hz
Voltage Regulation No
Total Current Capacity 15 A (1800 W)
Voltage Protection Rating (UL1449 3rd Edition, 3,000A) 500V
Protection Modes L-N, L-G, N-G
Initial Clamping Level 200V Peak, 141V RMS
Energy Dissipation 2350 Joules
Peak Impulse Current 75,000 Amps
Catastrophic Surge Circuit Yes
Thermal Fusing Yes
Auto-resetting Over-voltage shutoff 142 VAC ± 8 VAC
Auto-resetting Under-voltage shutoff 86 VAC ± 6 VAC
EMI/RFI Noise Filtration
Bank 1 Up to -86 db (100 KHz – 2 MHz)
Bank 2 Up to -91 db (100 KHz – 2 MHz)
Bank 3 Up to -81 db (100 KHz – 2 MHz)
Bank 4 Up to -100 db (100 KHz – 2 MHz)
Bank 5, High Current Outlets Up to -81 db (100 KHz – 2 MHz)
DC Trigger Input
Jacks 3.5mm (1/8") mono mini-plug
Voltage and Polarity 3 - 24V DC, bidirectional
Current Requirement 4.6 mA @3V, 58 mA @24V
LAN Protection
Clamping Level 60V ± 5V
Compatibility 10/100bT
Connectors RJ-45
Wires Protected 8-Wires
USB Circuit
Jacks USB-A
Power Delivery 500 mA @ 5 VDC
Telco Protection
Fuseless/Auto-resetting Yes
Clamping Level 260V
Capacitance 30pf (approx.)
Suppression Modes Metallic & Longitudinal
Wires Protected 2-Wire, Pins 4 & 5
Connectors RJ-11
Universal Coax Protection
HD 1080 i/p Ready Yes
Shielded Yes
Clamping Level 75V
Frequency Range 0 MHz - 2.2 GHz
Insertion Loss < 0.5 dB
Connectors Female "F", Gold Plated
Bidirectional Yes
DC Trigger Output
Pass through no delay
Positive = Tip, Negative = Ring

UPC's, Quantities, Weights & Measurements for Ordering & Shipping

MODEL UNIT CARTON MASTER CARTON UPC Qty Dimensions Weight UPC
Dimensions Weight Dimensions Weight
M5300-PM 17" x 12.75" x 3.5"
4.1" H with feet
14 lbs 23.25" x 19" x 9.25" 18 Lbs 0 50616 00816 7 1 23.75" x 19.75" x 10" 20 Lbs 5 00 50616 00816 2
M5300PM Spec Sheet Adobe PDF library 8.00 Adobe Illustrator CS3

Related Documents

Preview Panamax M5300-PM Power Conditioner and Surge Protector: Features, Specifications, and Warranty
Comprehensive guide to the Panamax M5300-PM power conditioner and surge protector. Details key features like Linear Filtering Technology (LiFT) and Automatic Voltage Monitoring (AVM), explains front and back panel connections, lists technical specifications, and outlines product warranty information.
Preview Panamax M5400-PM Power Conditioner: Features, Specifications, and Warranty
Comprehensive guide to the Panamax M5400-PM power conditioner, detailing its voltage regulation, surge protection, EMI/RFI noise filtration, isolated outlet banks, sequential startup/shutdown, front and back panel features, technical specifications, and connected equipment protection policy.
Preview Panamax M5400-PM Power Conditioner and Surge Protector User Manual
Comprehensive guide to the Panamax M5400-PM, detailing its voltage regulation, LiFT noise filtration, automatic over/under voltage protection, sequential startup/shutdown, USB charging, LAN protection, and warranty information.
Preview Panamax M5300-PM Home Theater Power Management System
Detailed specifications and features of the Panamax M5300-PM, a Level 4 power management system designed to improve audio-visual performance through advanced surge protection, noise filtration, and voltage monitoring.
Preview Panamax M5400-PM Power Conditioner: Features, Specifications, and Warranty
Comprehensive guide to the Panamax M5400-PM power conditioner, detailing its voltage regulation, noise filtration, surge protection, connectivity options, specifications, and limited warranty.
Preview Panamax MR5100 Home Theater Power Management and Surge Protection Guide
Comprehensive guide to the Panamax MR5100, detailing its features, specifications, safety guidelines, and warranty information for home theater power management and surge protection.
Preview Panamax MR4000 Power Conditioner and Surge Protector Reference Guide
Comprehensive reference guide for the Panamax MR4000 Home Theater Power Management unit, detailing its features, specifications, safety guidelines, and warranty information for protecting audio-video and electronic equipment.
Preview Panamax: Advanced Power and Energy Management Solutions for Home Electronics
Discover Panamax's comprehensive range of power management, surge protection, and energy control products designed to optimize performance and protect your valuable home electronics. Explore solutions for home theater, audio/video systems, and more.