DocumentDocumentHART Transmitter Power Supply, Input Isolator LB3005A2 < 4-channel < Power supply for 2-wire transmitters with 4 mA ... 20 mA < Installation in Zone 2 or safe area < Supply circuit 15 V (20 mA) < Input from active signals of 4-wire transmitters < HART communication via field bus or service bus < Simulation mode for service operations (forcing) < Line fault detection (LFD): one LED per channel < Permanently self-monitoring < Module can be exchanged under voltage Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 254700_eng.pdf Function The transmitter power supply feeds 2-wire transmitters. Active signals from separately powered field devices and 4-wire transmitters can be connected. Open and short circuit line faults are detected. The inputs are galvanically isolated from the bus and the power supply. Connection COM HART 8- 16- mA II 7+ IV 15+ 6- 14- 5+ 13+ 4- 12- mA I 3+ III 11+ 2- 10- 1+ 9+ HART Technical Data Slots Occupied slots Supply Connection Rated voltage Power dissipation Power consumption Internal bus Connection Interface Zone 2 2 backplane bus Ur 12 V DC , only in connection with the power supplies LB9*** 1.5 W 2.7 W backplane bus manufacturer-specific bus to standard com unit Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group www.pepperl-fuchs.com USA: +1 330 486 0002 pa-info@us.pepperl-fuchs.com Germany: +49 621 776 2222 pa-info@de.pepperl-fuchs.com Singapore: +65 6779 9091 pa-info@sg.pepperl-fuchs.com 1 HART Transmitter Power Supply, Input Isolator Technical Data LB3005A2 Analog input Number of channels Suitable field devices Field device Field device [2] Field device [3] Field device [4] Field device interface Connection Connection [2] Connection [3] Connection Transmitter supply voltage Input resistance Conversion time Line fault detection Short-circuit Open-circuit HART communication HART secondary variable Transfer characteristics Deviation After calibration Influence of ambient temperature Resolution Refresh time Indicators/settings LED indication Coding Directive conformity Electromagnetic compatibility Directive 2014/30/EU Conformity Electromagnetic compatibility Degree of protection Environmental test Shock resistance Vibration resistance Damaging gas Relative humidity Ambient conditions Ambient temperature Storage temperature Relative humidity Shock resistance 4 pressure converter flow converter level converter Temperature Converter 2-wire transmitter 3-wire transmitter 4-wire transmitter 2-wire transmitter (HART):Supply circuit: channel I 1+, 2-, channel II 5+, 6-, channel III 9+, 10-, channel IV 13+, 14-3-wire transmitter:Supply circuit: channel I 1+, 4-, channel II 5+, 8-, channel III 9+, 12-, channel IV 13+, 16-Measurement loop: channel I 3+, 4-, channel II 7+, 8-, channel III 11+, 12-, channel IV 15+, 16-4-wire transmitter (powered externally):Measurement loop: channel I 3+, 4-, channel II 7+, 8-, channel III 11+, 12-, channel IV 15+, 16min. 15 V at 20 mA ; 21.5 V at 4 mA 15 max. 100 ms can be switched on/off for each channel via configuration tool , configurable via configuration tool factory setting: > 22 mA configurable between 0 ... 26 mA factory setting: < 1 mA configurable between 0 ... 26 mA yes no 0.1 % of the signal range at 20 °C (68 °F) 0.1 %/10 K of the signal range 12 Bit (0 ... 26 mA) 100 ms Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit) optional mechanical coding via front socket EN 61326-1:2013 NE 21:2007 IEC 60529:2000 EN 60068-2-14:2009 EN 60068-2-27:2009 EN 60068-2-6:2008 EN 60068-2-42:2003 EN 60068-2-78:2001 -40 ... 60 °C (-40 ... 140 °F) , 70 °C (non-Ex) -40 ... 85 °C (-40 ... 185 °F) 95 % non-condensing shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 254700_eng.pdf Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group www.pepperl-fuchs.com USA: +1 330 486 0002 pa-info@us.pepperl-fuchs.com Germany: +49 621 776 2222 pa-info@de.pepperl-fuchs.com Singapore: +65 6779 9091 pa-info@sg.pepperl-fuchs.com 2 HART Transmitter Power Supply, Input Isolator Technical Data LB3005A2 Vibration resistance frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance Damaging gas designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Degree of protection IP20 when mounted on backplane Connection removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) Mass approx. 150 g Dimensions 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch) Data for application in connection with hazardous areas Certificate BVS 12 ATEX E 105 X Marking 1 II 3 G Ex nA [ic] IIC T4 Gc Galvanic isolation Input/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V Directive conformity Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 EN 60079-11:2012 EN 60079-15:2010 International approvals ATEX approval BVS 12 ATEX E 105 X IECEx approval BVS 12.0055X Approved for Ex nA [ic] IIC T4 Gc General information System information The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure. Supplementary information EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. Assembly Front view Power LED green Status LED red per channel P I 1 2 3 4 Ex ic Ex ic Diagnostic LED red/white Release date: 2021-12-01 Date of issue: 2021-12-01 Filename: 254700_eng.pdf 8 16 7 15 6 14 5 13 4 12 3 11 2 10 19 Sockets for removable plugs green (accessory) Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group www.pepperl-fuchs.com USA: +1 330 486 0002 pa-info@us.pepperl-fuchs.com Germany: +49 621 776 2222 pa-info@de.pepperl-fuchs.com Singapore: +65 6779 9091 pa-info@sg.pepperl-fuchs.com 3