Owner's Manual for ARROW models including: PB-40002-100B, PR-45563-HPHNL, LBL070055 R01, PB-40002-100B Pressure Injectable Arrowg plus ard, PB-40002-100B, Pressure Injectable Arrowg plus ard, Injectable Arrowg plus ard, Arrowg plus ard
PR-45563-HPHNL - Teleflex Incorporated - Vascular Access Product Catalog
File Info : application/pdf, 1 Pages, 707.89KB
DocumentDocumentDimensions: Width: 8-1/2" Length: 11 PB-40002-100B 6 NO NO CT CT ADVANCE Antimicrobial Antithrombogenic PR-45563-HPHNL (IPNXXXXXX) 6 3 Fr. Lumen 55 cm catheter length .018 inch dia. spring-wire guide Pressure Injectable Arrowg+ard Blue Advance® Three-Lumen PICC with 130 cm Hydrophilic-Coated Nitinol Guidewire Contents: 1: Three Lumen TaperFree® Catheter with Arrowg+ard Blue Advance® Antimicrobial/Antithrombogenic Protection1: 6 Fr. (2.11 mm OD) x 55 cm Pressure Injectable and Contamination Guard 1: GlideThruTM Peel-Away Sheath: 6 Fr. x 4" (10 cm) Radiopaque over 6 Fr. Dilator 1: Spring-Wire Guide, Nitinol, Marked: .018" (0.46 mm) dia. x 17-3/4" (45 cm) (Straight Soft Tip on One End - Straight Stiff Tip on Other) 1: Guidewire, Marked: .018" (0.46 mm) dia. x 130 cm Hydrophilic-Coated Nitinol with Soft Tip Tungsten Coil 1: Introducer Needle: Echogenic 21 Ga. x 2-3/4" (7 cm) TW 1: Syringe: 10 mL Luer-Lock 3: Dust Cap: Non-Vented 1: Catheter Trimmer 1: Safety Scalpel: #11 1: Patient ID Card 1: Patient Information Booklet 1: Paper Tape Measure 1: Dressing: STATLOCK®2 PICC Plus Catheter Stabilization Device 1Licensed under US Patent No. 7,329,412 and 11,219,706. 2A registered trademark of C. R. Bard, Inc. All components are CE 2797 unless otherwise noted. Rx only Warning: Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death. www.teleflex.com/IFU California Prop. 65 WARNING: Cancer and Reproductive Harm. www.P65Warnings.ca.gov MR Safe Not made with natural rubber latex. Store below 25°C (77°F). Avoid excessive heat above 30°C (86°F). Fluid path components are non-pyrogenic. Contraindications: The Pressure Injectable Arrowg+ard Blue Advance antimicrobial/antithrombogenic catheter is contraindicated: · for patients with known hypersensitivity to chlorhexidine · in the presence of device related infection in the intended insertion vessel or catheter pathway · in the presence of thrombosis in the intended insertion vessel or catheter pathway Lumen Pink (18 Ga.) Blue (19 Ga.) White (19 Ga.) Priming Volume* (mL) 0.70 0.52 0.49 Gravity Flow Rate (mL/hr) 990 240 270 Pump Flow Rate (mL/hr) 5440 1930 2070 MAX Pressure Injection Flow Rate** (mL/sec) 6 not rated not rated * Priming volumes are approximate and are done without accessories. Flow rate values are approximate and are determined using deionized water at 100 cm head height. Pump flow rates are determined at maximum pump pressure of 10 psig and represent approximate flow capabilities. ** Pressure injection flow rates are determined at the injector pressure setting of 300 psi maximum using media of 11.8 centipoise viscosity, with 152 cm pressure tubing. LotNumber YYYY-MM-DD YYYY-MM-DD (01)XXXXXXXXXXXXXX (17)YYMMDD (11)YYMMDD (10)LotNumber CAS # 7440-48-4 EU Authorized Representative and Importer: Teleflex Medical IDA Business and Technology Park Dublin Road, Athlone Co. Westmeath, Ireland All components are CE 2797 unless otherwise noted. Arrow International LLC Subsidiary of Teleflex Incorporated 3015 Carrington Mill Blvd. Morrisville, NC 27560 USA Product of XXX Packaged in XXX LBL070055 R01 (2024-05)