User Manual for UNITRONGROUP models including: 4002, 4003, 4004, 4004 Optical Headend, 4004, Optical Headend, Headend

Alexander Steen

 User Manual

4003 - Tienda Profesional Antares Sistemas


File Info : application/pdf, 12 Pages, 892.50KB

PDF preview unavailable. Download the PDF instead.

4002-4003-4004 MANUAL ENGLISH
User Manual
Optical Headend Ref. 4002 & 4003 & 4004

Optical Headend (Ref. 4002 & 4003 & 4004)
CONTENTS
1. INTRODUCTION .............................................................................. 3
Product description ............................................................................................ 3 Package contents .............................................................................................. 3
2. CONFIGURATION OF THE MODULE........................................................ 4 3. INSTALLATION OF THE HARDWARE ...................................................... 6
Wideband to SCR (up to 64 splits) ....................................................................... 6 Hybrid dSCR Solution: Wideband to SCR + CATV (up to 64 splits) ........................... 7 Legacy and dSCR: Wideband to SCR + CATV (up to 64 splits) ................................. 8 Dual Wideband + CATV (up to 32 splits)............................................................... 9
4. TECHNICAL SPECIFICATIONS ........................................................... 10 5. SAFETY INSTRUCTIONS .................................................................. 11 6. CONDITIONS OF WARRANTY ............................................................ 12
No part of this manual may be copied, reproduced, transmitted, transcribed or translated into any language without permission. Unitron reserves the right to change the specifications of the hardware and software described in these manuals at any time. Unitron cannot be held liable for any damages resulting from the use of this product. Specifications are subject to change without notice. 7/23 © Unitron NV - Frankrijklaan 27 - B-8970 Poperinge - Belgium T +32 57 33 33 63 F +32 57 33 45 24 sales@unitrongroup.com www.unitrongroup.com
2

Optical Headend (Ref. 4002 & 4003 & 4004)
1. INTRODUCTION
Product description
The new Optical Compact Headend converts Wideband/CATV signals to multiple optical wavelengths. Thanks to built-in Automatic Gain Control (AGC) and Automatic Slope Control (ASC), the output signal quality is optimal for your optical distribution system (9 dBm output power). The Optical Transmitters are suited for many types of optical systems: up to 64 splits, up to 128 splits and even more than 2000 splits! REF 4002: OPTICAL HEADEND TRANSMITTER 2 WAVELENGTHS
· 2 Wideband inputs · Frequency range: SAT: 290 ­ 2340 MHz (Wideband) / 950 ­ 2150 MHz (Quattro) · 1 Optical output (wavelengths 1310 - 1330nm) REF 4003: OPTICAL HEADEND TRANSMITTER 3 WAVELENGTHS · 2 Wideband and 1 CATV inputs · frequency range: SAT: 290 ­ 2340 MHz (Wideband) / 950 ­ 2150 MHz (Quattro) /
CATV: 40 ­ 1218 MHz · 1 Optical output (wavelengths 1310 ­ 1330 - 1550nm) REF 4004: OPTICAL HEADEND TRANSMITTER 3 WAVELENGTHS · 2 Wideband and 1 CATV inputs · frequency range: SAT: 290 ­ 2340 MHz (Wideband) / 950 ­ 2150 MHz (Quattro) /
CATV: 40 ­ 1218 MHz · 1 Optical output (wavelengths 1350 ­ 1370 -1550 & 1310 ­ 1330 from optical
loopthrough)
Package contents
· 1x Optical Headend (REF 4002 or REF 4003 or REF 4004) · Not included: 20V / 3A Power Supply (Ref. 2460)
3

Optical Headend (Ref. 4002 & 4003 & 4004)
2. CONFIGURATION OF THE MODULE
Select LNB Type:
With this switch you can select the frequency range of the Sat input signal. This is necessary to make the Automatic Slope Control (ASC) working properly. If signals of a Quattro LNB are inserted, then set the switch to "Q". If Wideband signals are inserted, set the switch to "WB".
Select # splits (only for REF. 4003 and REF. 4004):
With this switch you can select the number of splits in your system, this is necessary to make the Automatic Gain Control working properly.
4

Optical Headend (Ref. 4002 & 4003 & 4004)
Signal Quality LED:
The signal quality LED shows you the quality of the signal with different colors. Orange Color: Signal level is too low. In this case you should amplify the signal with an external amplifier. Green Color: Signal level is within the AGC supported range. Red Color: Signal level is too high. You need to attenuate the signal with external attenuator(s). Solid LED: Slope is OK Blinking LED: Slope is out of range
Set DC Supply and Laser Diode:
With this switch you can set the DC (18V) supply to the RF input and switch off the Laser Diode (LD) in order to measure each optical signal separately. To measure the signal strength of a certain wavelength, you need to switch off both other Laser Diodes. Don't forget to switch all LDs on after measurement. The LED is off if no DC is supplied to the RF input and if no DC is supplied to the Laser Diode. If no DC is supplied to the laser diode, the related signal is not converted into an optical signal. Please make sure to switch on at least the laser diode for proper operation. The LED is green if the Laser diode is switched on and the related output voltage off. The LED is orange if the Laser diode is switched on the related output voltage is supplied to the RF input. The LED is green/orange blinking if DC is supplied to the RF input and the device recognized a short circuit.
Optical output:
The optical transmitters each have an optical output power of +9 dBm per wavelength. For REF.4003 and REF. 4004, make sure to set the select the right number of splits using the split switch.
5

Optical Headend (Ref. 4002 & 4003 & 4004)
3. INSTALLATION OF THE HARDWARE
Wideband to SCR (up to 64 splits)
6

Optical Headend (Ref. 4002 & 4003 & 4004)
Hybrid dSCR Solution: Wideband to SCR + CATV (up to 64 splits)
7

Optical Headend (Ref. 4002 & 4003 & 4004)
Legacy and dSCR: Wideband to SCR + CATV (up to 64 splits)
8

Optical Headend (Ref. 4002 & 4003 & 4004)
Dual Wideband + CATV (up to 32 splits)
9

Optical Headend (Ref. 4002 & 4003 & 4004)

4. TECHNICAL SPECIFICATIONS

REF 4002

REF 4003

REF 4004

RF Inputs (F-connector)

-

2 x Satellite (WB / Q)

2 x Satellite (WB / Q) 1 x CATV

Input frequency SAT

MHz

Wideband: 290 - 2340 Quattro: 950 - 2150

Input frequency CATV MHz

-

47 - 1218

Optical outputs (SC/APC) -

1

Optical inputs (SC/APC) Optical output wavelengths nm
Optical output power dBm

1310 - 1330

1310 ­ 1330 - 1550 +9 (per wavelength)

1
1310 ­ 1330 (Bypass) 1350 ­ 1370 ­ 1550

Minimal input level SAT dBµV

Minimal input level CATV dBµV

-

DC supply

-

75 - 95
55 - 75 (CATV 4 splits) 65 - 85 (CATV >4 splits)
18V / 400mA

DC supply CATV

-

-

12V / 200mA

Automatic Gain Control dB

15

Automatic Slope Control dB

10

Power consumption

W

22

27

DC input Power Supply

-

20 V / 1.1A (F-type)

20 V / 1.35A (F-type)

-

Use a 20V / 3A Power Supply (Ref. 2460) Not included with product

Operating temperature range °C

-10 to +50

Dimensions

Mm

Weight

kg

221 x 141 x 50 0.8

10

Optical Headend (Ref. 4002 & 4003 & 4004)
5. SAFETY INSTRUCTIONS
Read these instructions carefully before connecting the unit
To prevent fire, short circuit or shock hazard: · Do not expose the unit to rain or moisture. · Install the unit in a dry location without infiltration or condensation of water. · Do not expose it to dripping or splashing. · Do not place objects filled with liquids, such as vases, on the apparatus. · If any liquid should accidentally fall into the cabinet, disconnect the power plug. To avoid any risk of overheating: · Install the unit in a well aery location and keep a minimum distance of 15 cm around the
apparatus for sufficient ventilation · Do not place any items such as newspapers, table-cloths, curtains,
on the unit that might cover the ventilation holes. · Do not place any naked flame sources, such as lighted candles, on the apparatus · Do not install the product in a dusty place · Use the apparatus only in moderate climates (not in tropical climates) · Respect the minimum and maximum temperature specifications To avoid any risk of electrical shocks: · Connect apparatus only to socket with protective earth connection. · The mains plug shall remain readily operable · Pull out power plug to make the different connections of cables · To avoid electrical shock, do not open the housing of adapter.
Maintenance
Only use a dry soft cloth to clean the cabinet. Do not use solvent For repairing and servicing refer to qualified personnel.
Dispose according your local authority's recycling processes
11

Optical Headend (Ref. 4002 & 4003 & 4004)
6. CONDITIONS OF WARRANTY
Unitron N.V. warrants the product as being free from defects in material and workmanship for a period of 24 months starting from the date of production indicated on it. See note below. If during this period of warranty the product proves defective, under normal use, due to defective materials or workmanship, Unitron N.V, at its sole option, will repair or replace the product. Return the product to your local dealer for reparation. THE WARRANTY IS APPLIED ONLY FOR DEFECTS IN MATERIAL AND WORKMANSHIP AND DOES NOT COVER DAMAGE RESULTING FROM: · Misuse or use of the product out of its specifications, · Installation or use in a manner inconsistent with the technical or safety standards in
force in the country where the product is used, · Use of non-suitable accessories (power supply, adapters...), · Installation in a defect system, · External cause beyond the control of Unitron N.V. such as drop, accidents,
lightning, water, fire, improper ventilation... THE WARRANTY IS NOT APPLIED IF · Production date or serial number on the product is illegible, altered, deleted or
removed. · The product has been opened or repaired by a non-authorized person.
NOTE
Date of production can be found in the product's serial number code. The format will either be "YEAR W WEEK" (e.g., 2017W32 = year 2017 week 32) or "YYWW" (e.g., 1732 = year 2017 week 32).
UNITRON NV Frankrijklaan 27 B-8970 Poperinge Belgium T +32 57 33 33 63
sales@unitrongroup.com www.unitrongroup.com