Instruction Manual for MYSON models including: Kickspace 600, Kickspace 500, Hydronic Plinth Fan Convector Heater, Plinth Fan Convector Heater, Fan Convector Heater, Convector Heater, Kickspace 600, Heater
Myson Kickspace 500 Installation and Operating Manual – Jungle Property Knowledgebase
File Info : application/pdf, 8 Pages, 558.09KB
DocumentDocumentKICKSPACE® 500, 600 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER COMPLETE HEATING SOLUTIONS 02 KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D Contents 1.0 Safety Information 02 2.0 Installation 03 3.0 Water Connection 03 4.0 Electrical Connection 04 5.0 Controls 04 6.0 Troubleshooting 04 7.0 Appendix 05 1.0 Safety Information The KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D MUST NOT be installed in a bathroom or other similar high humidity area. WARNING: KICKSPACE® 500, 600, 800, 80S & 80D models must be earthed. For MYSON KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D, a fused (3A) electrical spur with a switch having 3mm separation on all poles must be provided in an easily accessible position adjacent to the unit. For the KICKSPACE® 600-12V, a fused electrical spur having 3mm separation on all poles must be provided in an easily accessible position adjacent to the transformer. Both the fused spur and the transformer must not be positioned in a bathroom or other similar high humidity area. If the supply cord to the KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D is damaged, it must be replaced by the manufacturer, its service agent or similar qualified persons in order to avoid a hazard. This appliance can be used by children aged from 8 years and above and persons with reduced physical or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children unless they are older than 8 years and supervised. Keep the appliance and its cord out of reach of children aged less than 8 years. Children of less than 3 years should be kept away from the unit unless continuously supervised. Children aged from 3 years and less than 8 years shall only switch on / off the appliance provided that it has been placed or installed in its normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, clean the appliance or perform user maintenance. KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL 01.01.2018 KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D 03 1.0 2.0 3.0 2.0 Installation G Before proceeding with the installation, the heating system design must be considered and the unit correctly sized to meet the heat loss requirements of the room. G Before proceeding with the installation, unpack the carton contents and check against the checklist below: 1. KICKSPACE® unit. 2. Flexible hoses including isolating valves (1 pair). 3. Instruction manual. 4. Warranty card. 5. Grille. 6. Screw fixing kit (with grille). 7. Transformer (12V model only). 8. Connector (12V model only). G This MYSON KICKSPACE® fan convector is designed for installation in the cavity beneath kitchen cupboards on the vacant floor space, or other similar locations. G For KICKSPACE® 500, 600, 600-12V & 800 a minimum of 25mm clear headroom is required above the top of the KICKSPACE® when fitted. G The unit should be mounted on a clean and level floor area under the cupboard base. G KICKSPACE® 80S & 80D models can only be installed if there is a minimum height of 80mm from the top of the floor covering to the underside of the kitchen unit (see Fig. 1). G KICKSPACE® 500, 600, 600-12V & 500 floor mounting (see Fig. 2a) - The KICKSPACE® is normally fitted directly onto the floor and the base of the unit is fitted with four mounting feet. G KICKSPACE® 500, 600, 600-12V & 500 plinth mounting (see Fig. 2b) · As an alternative to floor mounting the unit may be fitted into the plinth. · A suitable support must be securely fitted to the floor. · The top of the support must be level with the lower edge of the cut-out when fitted. G KICKSPACE® 80S & 80D floor mountings (see fig. 2c) - Applies to 80S & 80D units in 80mm plinth height kitchen unit. G Decide the position of the KICKSPACE®, mark out and cut the plinth to the dimensions using table on page 6. G Position the KICKSPACE® under the cupboard in the required location, with the front edge just behind the line of the plinth. G Replace the plinth and bring the KICKSPACE® forward into the opening so the front edge projects approximately 10mm through the plinth. G Align the grille and secure it to the unit with two screws supplied (use the shorter screws). (See Fig. 3). G Secure the unit/grille to the plinth with two screws supplied (use the longer screws). (See Fig. 3). G Complete the electrical installation, switch on and test the KICKSPACE® (see Fig. 3). G When installed in a kitchen consideration should be given to storage of perishable goods in the cupboard above. 3.0 Water Connection G The KICKSPACE® should only be used on closed circulation, two pipe, pump assisted central heating systems. G For optimum fan convector heating performance the system must be capable of providing sufficient hot water through the heat exchanger. This means that: 1. The minimum pipe size from boiler to fan convector must be at least 15mm. Microbore pipe MUST NOT be used. 2. Where the unit is fitted on to a system with other emitters a separate circuit for the fan convector should be considered to provide adequate water flow. 3. The system water temperature on the return of the KICKSPACE® must be above 43°C for the fan to switch on. 4. This unit is NOT suitable for one-pipe systems. 5. Optimum performance will require effective balancing of the whole system. 6. This unit must not be used to replace a radiator in an existing system unless an adequate flow of water can be guaranteed. Pipework must be positioned correctly to ensure flexible hoses are not kinked when installed (see Figs. 5a & 5b). Only use the hose sets supplied with this unit. Do not use old or alternative hose sets. G Connect valve ends of the flexible pipes to the KICKSPACE®. Note: The direction of the arrows on the valves are not significant in this application (see Fig. 4). G Open valves fully, check pipe connections for leaks and vent the heat exchanger. A vent screw is provided to vent the heat exchanger. KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL 01.01.2018 04 KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D 4.0 Electrical Connection WARNING: KICKSPACE® 500, 600, 800, 80S & 80D models must be earthed. G The electrical installation must comply with local or national wiring regulations. G This unit is supplied fitted with a 2 metre 0.75mm2 cord. G For KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D a fused (3A) electrical spur with a switch having 3mm separation on all poles must be provided in an easily accessible position adjacent to the unit (see Fig. 6a). G For the KICKSPACE® 600-12V, a fused electrical spur having 3mm separation on all poles must be provided in an easily accessible position adjacent to the transformer. Both the fused spur and the transformer must not be positioned in a bathroom or other similar high humidity installation (see Fig. 6b). G If the supply cord to KICKSPACE® models 500, 600, 800, 80S and 80D is damaged, it must be replaced by the manufacturer, its service agent or similar qualified persons in order to avoid a hazard. G If the supply or outlet cord to KICKSPACE® 600-12V transformer is damaged, it must be replaced by the manufacturer, its service agent or similar qualified persons in order to avoid a hazard. G For the KICKSPACE® 600-12V, a connector block is supplied to connect the low voltage supply from the transformer to the supply cord fitted to the unit. Do not energise the electrical supply until the remaining stages of the installation have been completed. 5.0 Controls This unit is controlled by the switches on the front of the unit (see Fig. 3). Ensure the electricity supply is switched on. Heating Mode · Set the heating/fan only switch to heating · Set fan speed control to position I · The unit will now run on low fan speed. The system water temperature on the return of the KICKSPACE® must be above 43°C for the fan to switch on* *Eg. When the mean water temperature is greater than 43°C the fan will switch on, then when the water temperature drops below 43°C the fan will switch off. Performance will depend on the water temperature at the coil and the flow through the coil. 6.0 Troubleshooting The fan speed can be set to boost by switching the fan speed switch to II. A low speed setting is recommended for normal operation with the higher speeds for boost heating when required. Off Position Set the fan speed selector switch to the off (O) position. Fan Only Mode If required, the KICKSPACE® can be used in summer for air circulation without heat. · Set the heating/fan only switch to fan only · Adjust fan speed to required setting. Once installed this fan convector becomes an integral part of a complete heating system that includes boiler, pump, other emitters such as radiators and fan convectors, and a number of heating controls, dependent on system complexity. An apparent problem with this unit may be the result of system controls being incorrectly set and can be solved easily without calling out your installer. Before calling your installer, please carry out the checks listed below. Problem Possible Causes Remedy Fan not working in heating mode Unit switched off Room thermostat not calling for heat Unit not switched on at fused spur Fuse blown at fused spur Unit isolating valves shut Water temperature of KICKSPACE® below 43°C Turn on Turn up room thermostat Switch on at spur Replace fuse Open valves Ensure boiler, pump and other central heating equipment is working correctly, if not contact your installer Note: Operation of fan can be checked by switching to fan only setting If the fan convector is still faulty after checking the above, call your installer. KICKSPACE® may have poor performance/cycle if a low water temperature/flow rate is supplied, please refer to your installer as this could be from the following: · Unit incorrectly sized for heat loss of room · Lack of flow to KICKSPACE® from heating system · Pipe sizes/pump sized incorrectly · System incorrectly balanced KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL 01.01.2018 KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D 05 KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL 01.01.2018 7.0 Appendix Heating Performance Data Model 500 600 600-12V 800 80S 80D Fan Speed Normal Boost Normal Boost Normal Boost Normal Boost Normal Boost Normal Boost T20 393 447 467 607 467 607 747 845 304 331 421 475 Temperature Difference (°C) Heat Output (Watts) Heat Output (Btu/h) T30 T40 T50 T60 T20 T30 T40 T50 566 733 896 1056 1340 1930 2501 3057 683 923 1166 1412 1524 2331 3150 3980 729 1000 1278 1562 1592 2486 3412 4361 939 1279 1625 1977 2072 3203 4363 5545 729 1000 1278 1562 1592 2486 3412 4361 939 1279 1625 1977 2072 3203 4363 5545 1077 1396 1707 2012 2550 3675 4763 5824 1289 1738 2192 2649 2885 4397 5930 7478 455 605 755 905 1037 1552 2064 2576 509 691 876 1062 1129 1737 2358 2989 624 824 1023 1221 1436 2129 2811 3490 707 938 1169 1399 1621 2412 3200 3989 T60 3603 4817 5330 6744 5330 6744 6864 9039 3088 3624 4166 4773 Heat outputs tested in accordance with BS 4856 Part 1. Flow Rate: 340 ltr/h (75 gal/h). Flow Rate Correction Factors: 455 ltr/h (100 gal/h) multiply output by 1.03. 227 ltr/h (50 gal/h) multiply output by 0.96. 113 ltr/h (25 gal/h) multiply output by 0.85. Test Pressure 20 bar Maximum Working Pressure 10 bar Approximate Hydraulic Resistance through Fan Convectors Litres/h 455 340 227 113 mm wg 500 600 600-12V 800 788 1046 1046 911 488 625 625 544 231 326 326 258 82 95 95 82 80S 80D 592 613 372 439 207 295 95 176 kPa Litres/h 500 600 600-12V 800 80S 80D 455 7.7 10.3 10.3 8.9 5.8 6.0 340 4.8 6.1 6.1 5.3 3.6 4.3 227 2.3 3.2 3.2 2.5 2.0 2.9 113 0.8 0.9 0.9 0.8 0.9 1.7 Sound Levels Model Sound Pressures at 2.5m (dBA) Normal Boost 500 25.7 38.1 600 26.4 37.2 600-12V 29.4 39.0 800 28.5 49.8 80S 24.5 31.4 80D 21.8 35.6 Sound levels tested in accordance with EN 23741. Weight, Water Content and Motor Power Model Motor Power (W) 500 25 600 40 600-12V* 40 800 40 80S 13 80D 17 *Includes transformer. Water Content (l) 0.26 0.30 0.30 0.34 0.17 0.25 Unit Weight (kg) 4.3 5.0 7.9* 5.5 3.83 5.13 4.0 5.0 6.0 7.0 06 KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D 7.0 Appendix (continued...) KICKSPACE® 500 View on arrow Cable entries 54 24 12 93 67 Top view 82 36 309 Cable entry Mains cable 25 129 322 FRONT GRILLE 101 KICKSPACE® 600 & 600-12V 54 24 12 82 36 309 View on arrow Cable entries 93 67 Top view Cable entry Mains cable 25 129 376 FRONT GRILLE 101 KICKSPACE® 800 54 24 12 82 36 309 View on arrow Cable entries 93 67 Top view Cable entry Mains cable 25 129 447 FRONT GRILLE 101 496 550 KICKSPACE® 80S 36 21 14 24.5 View on arrow Cable entries 4472 Top view 123 40 301 Cable entry Mains cable 25 123 603 KICKSPACE® 80D 36 21 14 24.5 View on arrow Cable entries 4472 Top view 123 40 301 Cable entry Mains cable 25 123 432 FRONT GRILLE 80 560 602 FRONT GRILLE 80 760 Dimensions Dimensions (mm) Model A B 500 466 600 & 600-12V 520 800 573 80S 530 80D 730 93 93 93 80 80 FLOOR COVERING Fig. 1 80mm FLOOR COVERING 80mm A = Width of cutout B = Height of cutout For corresponding diagrams please refer to Figs. 2a, 2b & 2c overleaf. KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL 01.01.2018 7.0 Appendix (continued...) KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D 07 A B Fig. 2a Plinth opening - floor mounting A B Fig. 2b Plinth opening - plinth mounting Grille securing screw Heating/fan only switch Grille securing screw A B Fig. 2c Plinth opening - 80mm plinth height Flexible pipes Unit securing screw Fig. 3 Front view of unit Switch for fan Boost Off Normal Unit securing screw Isolating valves Fig. 4 WALL WALL 250 300 400 100 Fig. 5a Left hand view - suggestion only Fig. 5b Right hand view - suggestion only L br N bl g/y MOTOR bl yr Fan Selector Switch L Mains Supply 240V N Transformer MOTOR br bl br bl Connector Block Chassis Earth bl bl Fan Only/Heating Switch LOW LIMIT THERMOSTAT Fig. 6a KICKSPACE® 500, 600, 800, 80S & 80D wiring diagram LOW LIMIT THERMOSTAT Fig. 6b KICKSPACE® 600-12V wiring diagram Fan Selector Switch Fan Only/Heating Switch KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL 01.01.2018 7.0 Product Serial Number: Product code and serial number location COMPLETE HEATING SOLUTIONS 01.01.18Acrobat Distiller 18.0 (Macintosh)