KICKSPACE® 500, 600 600-12V, 800, 80S & 80D
INSTALLATION & OPERATING MANUAL
PLEASE LEAVE THIS MANUAL WITH THE END USER
COMPLETE HEATING SOLUTIONS

02 KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D

Contents

1.0 Safety Information

02

2.0 Installation

03

3.0 Water Connection

03

4.0 Electrical Connection

04

5.0 Controls

04

6.0 Troubleshooting

04

7.0 Appendix

05

1.0 Safety Information

The KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D MUST NOT be installed in a bathroom or other similar high humidity area.

WARNING: KICKSPACE® 500, 600, 800, 80S & 80D models must be earthed.

For MYSON KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D, a fused (3A) electrical spur with a switch having 3mm separation on all poles must be provided in an easily accessible position adjacent to the unit.
For the KICKSPACE® 600-12V, a fused electrical spur having 3mm separation on all poles must be provided in an easily accessible position adjacent to the transformer. Both the fused spur and the transformer must not be positioned in a bathroom or other similar high humidity area.
If the supply cord to the KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D is damaged, it must be replaced by the manufacturer, its service agent or similar qualified persons in order to avoid a hazard. This appliance can be used by children aged from 8 years and above and persons with reduced physical or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.

Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children unless they are older than 8 years and supervised.
Keep the appliance and its cord out of reach of children aged less than 8 years.
Children of less than 3 years should be kept away from the unit unless continuously supervised.
Children aged from 3 years and less than 8 years shall only switch on / off the appliance provided that it has been placed or installed in its normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children aged from 3 years and less than 8 years shall not plug in, clean the appliance or perform user maintenance.

KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL 01.01.2018

KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D 03

1.0

2.0

3.0

2.0 Installation
G Before proceeding with the installation, the heating system design must be considered and the unit correctly sized to meet the heat loss requirements of the room.
G Before proceeding with the installation, unpack the carton contents and check against the checklist below:
1. KICKSPACE® unit. 2. Flexible hoses including isolating valves (1 pair). 3. Instruction manual. 4. Warranty card. 5. Grille. 6. Screw fixing kit (with grille). 7. Transformer (12V model only). 8. Connector (12V model only).
G This MYSON KICKSPACE® fan convector is designed for installation in the cavity beneath kitchen cupboards on the vacant floor space, or other similar locations.
G For KICKSPACE® 500, 600, 600-12V & 800 a minimum of 25mm clear headroom is required above the top of the KICKSPACE® when fitted.
G The unit should be mounted on a clean and level floor area under the cupboard base.
G KICKSPACE® 80S & 80D models can only be installed if there is a minimum height of 80mm from the top of the floor covering to the underside of the kitchen unit (see Fig. 1).
G KICKSPACE® 500, 600, 600-12V & 500 floor mounting (see Fig. 2a) - The KICKSPACE® is normally fitted directly onto the floor and the base of the unit is fitted with four mounting feet.

G KICKSPACE® 500, 600, 600-12V & 500 plinth mounting (see Fig. 2b) · As an alternative to floor mounting the unit may be fitted into the plinth. · A suitable support must be securely fitted to the floor. · The top of the support must be level with the lower edge of the cut-out when fitted.
G KICKSPACE® 80S & 80D floor mountings (see fig. 2c) - Applies to 80S & 80D units in 80mm plinth height kitchen unit.
G Decide the position of the KICKSPACE®, mark out and cut the plinth to the dimensions using table on page 6.
G Position the KICKSPACE® under the cupboard in the required location, with the front edge just behind the line of the plinth.
G Replace the plinth and bring the KICKSPACE® forward into the opening so the front edge projects approximately 10mm through the plinth.
G Align the grille and secure it to the unit with two screws supplied (use the shorter screws). (See Fig. 3).
G Secure the unit/grille to the plinth with two screws supplied (use the longer screws). (See Fig. 3).
G Complete the electrical installation, switch on and test the KICKSPACE® (see Fig. 3).
G When installed in a kitchen consideration should be given to storage of perishable goods in the cupboard above.

3.0 Water Connection
G The KICKSPACE® should only be used on closed circulation, two pipe, pump assisted central heating systems.
G For optimum fan convector heating performance the system must be capable of providing sufficient hot water through the heat exchanger. This means that:
1. The minimum pipe size from boiler to fan convector must be at least 15mm. Microbore pipe MUST NOT be used.
2. Where the unit is fitted on to a system with other emitters a separate circuit for the fan convector should be considered to provide adequate water flow.
3. The system water temperature on the return of the KICKSPACE® must be above 43°C for the fan to switch on.
4. This unit is NOT suitable for one-pipe systems.
5. Optimum performance will require effective balancing of the whole system.
6. This unit must not be used to replace a radiator in an existing system unless an adequate flow of water can be guaranteed.

Pipework must be positioned correctly to ensure flexible hoses are not kinked when installed (see Figs. 5a & 5b). Only use the hose sets supplied with this unit. Do not use old or alternative hose sets.
G Connect valve ends of the flexible pipes to the KICKSPACE®.
Note: The direction of the arrows on the valves are not significant in this application (see Fig. 4).
G Open valves fully, check pipe connections for leaks and vent the heat exchanger. A vent screw is provided to vent the heat exchanger.

KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL 01.01.2018

04 KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D

4.0 Electrical Connection WARNING: KICKSPACE® 500, 600, 800, 80S & 80D models must be earthed.

G The electrical installation must comply with local or national wiring regulations.
G This unit is supplied fitted with a 2 metre 0.75mm2 cord.
G For KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D a fused (3A) electrical spur with a switch having 3mm separation on all poles must be provided in an easily accessible position adjacent to the unit (see Fig. 6a).
G For the KICKSPACE® 600-12V, a fused electrical spur having 3mm separation on all poles must be provided in an easily accessible position adjacent to the transformer. Both the fused spur and the transformer must not be positioned in a bathroom or other similar high humidity installation (see Fig. 6b).

G If the supply cord to KICKSPACE® models 500, 600, 800, 80S and 80D is damaged, it must be replaced by the manufacturer, its service agent or similar qualified persons in order to avoid a hazard.
G If the supply or outlet cord to KICKSPACE® 600-12V transformer is damaged, it must be replaced by the manufacturer, its service agent or similar qualified persons in order to avoid a hazard.
G For the KICKSPACE® 600-12V, a connector block is supplied to connect the low voltage supply from the transformer to the supply cord fitted to the unit.

Do not energise the electrical supply until the remaining stages of the installation have been completed.

5.0 Controls

This unit is controlled by the switches on the front of the unit (see Fig. 3).
Ensure the electricity supply is switched on.
Heating Mode
· Set the heating/fan only switch to heating · Set fan speed control to position I · The unit will now run on low fan speed. The system water temperature on the return of the KICKSPACE® must be above 43°C for the fan to switch on*
*Eg. When the mean water temperature is greater than 43°C the fan will switch on, then when the water temperature drops below 43°C the fan will switch off.
Performance will depend on the water temperature at the coil and the flow through the coil.
6.0 Troubleshooting

The fan speed can be set to boost by switching the fan speed switch to II.
A low speed setting is recommended for normal operation with the higher speeds for boost heating when required.
Off Position
Set the fan speed selector switch to the off (O) position.
Fan Only Mode
If required, the KICKSPACE® can be used in summer for air circulation without heat.
· Set the heating/fan only switch to fan only · Adjust fan speed to required setting.

Once installed this fan convector becomes an integral part of a complete heating system that includes boiler, pump, other emitters such as radiators and fan convectors, and a number of heating controls, dependent on system complexity. An apparent

problem with this unit may be the result of system controls being incorrectly set and can be solved easily without calling out your installer. Before calling your installer, please carry out the checks listed below.

Problem

Possible Causes

Remedy

Fan not working in heating mode

Unit switched off Room thermostat not calling for heat
Unit not switched on at fused spur Fuse blown at fused spur Unit isolating valves shut Water temperature of KICKSPACE® below 43°C

Turn on Turn up room thermostat
Switch on at spur Replace fuse Open valves
Ensure boiler, pump and other central heating equipment is working correctly,
if not contact your installer
Note: Operation of fan can be checked by switching to fan only setting

If the fan convector is still faulty after checking the above, call your installer.

KICKSPACE® may have poor performance/cycle if a low water temperature/flow rate is supplied, please refer to your installer as this could be from the following:

· Unit incorrectly sized for heat loss of room · Lack of flow to KICKSPACE® from heating system · Pipe sizes/pump sized incorrectly · System incorrectly balanced

KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL 01.01.2018

KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D 05

KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL 01.01.2018

7.0 Appendix Heating Performance Data

Model
500 600 600-12V 800 80S 80D

Fan Speed
Normal Boost Normal Boost Normal Boost Normal Boost Normal Boost Normal Boost

T20 393 447 467 607 467 607 747 845 304 331 421 475

Temperature Difference (°C)

Heat Output (Watts)

Heat Output (Btu/h)

T30 T40 T50 T60 T20 T30 T40 T50

566

733

896 1056 1340 1930 2501 3057

683

923 1166 1412 1524 2331 3150 3980

729 1000 1278 1562 1592 2486 3412 4361

939 1279 1625 1977 2072 3203 4363 5545

729 1000 1278 1562 1592 2486 3412 4361

939 1279 1625 1977 2072 3203 4363 5545

1077 1396 1707 2012 2550 3675 4763 5824

1289 1738 2192 2649 2885 4397 5930 7478

455

605

755

905 1037 1552 2064 2576

509

691

876 1062 1129 1737 2358 2989

624

824 1023 1221 1436 2129 2811 3490

707

938 1169 1399 1621 2412 3200 3989

T60 3603 4817 5330 6744 5330 6744 6864 9039 3088 3624 4166 4773

Heat outputs tested in accordance with BS 4856 Part 1.
Flow Rate: 340 ltr/h (75 gal/h).
Flow Rate Correction Factors: 455 ltr/h (100 gal/h) multiply output by 1.03. 227 ltr/h (50 gal/h) multiply output by 0.96. 113 ltr/h (25 gal/h) multiply output by 0.85. Test Pressure 20 bar Maximum Working Pressure 10 bar

Approximate Hydraulic Resistance through Fan Convectors

Litres/h
455 340 227 113

mm wg

500

600

600-12V

800

788

1046

1046

911

488

625

625

544

231

326

326

258

82

95

95

82

80S

80D

592

613

372

439

207

295

95

176

kPa

Litres/h

500

600

600-12V

800

80S

80D

455

7.7

10.3

10.3

8.9

5.8

6.0

340

4.8

6.1

6.1

5.3

3.6

4.3

227

2.3

3.2

3.2

2.5

2.0

2.9

113

0.8

0.9

0.9

0.8

0.9

1.7

Sound Levels

Model

Sound Pressures at 2.5m (dBA)

Normal

Boost

500

25.7

38.1

600

26.4

37.2

600-12V

29.4

39.0

800

28.5

49.8

80S

24.5

31.4

80D

21.8

35.6

Sound levels tested in accordance with EN 23741.

Weight, Water Content and Motor Power

Model

Motor Power (W)

500

25

600

40

600-12V*

40

800

40

80S

13

80D

17

*Includes transformer.

Water Content (l)
0.26 0.30 0.30 0.34 0.17 0.25

Unit Weight (kg)
4.3 5.0 7.9* 5.5 3.83 5.13

4.0

5.0

6.0

7.0

06 KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D

7.0 Appendix (continued...)

KICKSPACE® 500

View on arrow Cable entries
54 24 12

93 67

Top view

82 36 309

Cable entry

Mains cable 25

129

322 FRONT GRILLE
101

KICKSPACE® 600 & 600-12V

54 24 12
82 36 309

View on arrow Cable entries

93 67

Top view

Cable entry

Mains cable 25
129

376 FRONT GRILLE
101

KICKSPACE® 800

54 24 12
82 36 309

View on arrow Cable entries

93 67

Top view

Cable entry

Mains cable 25
129

447 FRONT GRILLE
101

496

550

KICKSPACE® 80S

36 21

14 24.5

View on arrow Cable entries

4472

Top view

123 40 301

Cable entry

Mains cable 25 123

603

KICKSPACE® 80D

36 21

14 24.5

View on arrow Cable entries

4472

Top view

123 40 301

Cable entry

Mains cable 25 123

432 FRONT GRILLE 80
560

602 FRONT GRILLE 80
760

Dimensions

Dimensions (mm)

Model

A

B

500

466

600 & 600-12V

520

800

573

80S

530

80D

730

93 93 93 80 80

FLOOR COVERING
Fig. 1

80mm

FLOOR COVERING

80mm

A = Width of cutout B = Height of cutout

For corresponding diagrams please refer to Figs. 2a, 2b & 2c overleaf.

KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL 01.01.2018

7.0 Appendix (continued...)

KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D 07

A B
Fig. 2a Plinth opening - floor mounting

A

B

Fig. 2b Plinth opening - plinth mounting

Grille securing screw
Heating/fan only switch Grille securing screw

A B
Fig. 2c Plinth opening - 80mm plinth height
Flexible pipes

Unit securing screw

Fig. 3 Front view of unit

Switch for fan Boost Off Normal

Unit securing screw

Isolating valves Fig. 4

WALL

WALL

250 300

400 100

Fig. 5a Left hand view - suggestion only

Fig. 5b Right hand view - suggestion only

L

br

N

bl

g/y

MOTOR

bl

yr

Fan Selector Switch

L Mains Supply 240V
N

Transformer

MOTOR br
bl br bl
Connector Block

Chassis Earth

bl bl

Fan Only/Heating Switch

LOW LIMIT THERMOSTAT
Fig. 6a KICKSPACE® 500, 600, 800, 80S & 80D wiring diagram

LOW LIMIT THERMOSTAT
Fig. 6b KICKSPACE® 600-12V wiring diagram

Fan Selector Switch
Fan Only/Heating Switch

KICKSPACE® 500, 600, 600-12V, 800, 80S & 80D INSTALLATION & OPERATING MANUAL 01.01.2018