User Manual for TERACOM models including: TSM400-4-CPTH, CO2 Humidity and Temperature Multi Sensor, TSM400-4-CPTH CO2 Humidity and Temperature Multi Sensor, Humidity and Temperature Multi Sensor, Temperature Multi Sensor, Multi Sensor, Sensor
Teracom TSM400-4-CPTH | Delmation
Prodotti - SARC ITALIA Srl - Teracom
File Info : application/pdf, 6 Pages, 684.59KB
DocumentDocument1. Short description TSM400-4-CPTH is a multi-sensor that supports MODBUS RTU protocol over the RS-485 interface. The sensor measures CO2 concentration, temperature, humidity, and barometric pressure. The MODBUS device integrates an advanced non-dispersive infrared sensing element (NDIR) for CO2 measurements. The measurement principle is based on the absorption of infra-red (IR) light with specific wavelengths by CO2 molecules. The carbon dioxide sensing element is temperature compensated for better accuracy. Self-calibration is available for carbon dioxide measurements. It is done if the sensor is left in fresh (around 400 ppm CO2 concentration) air. The basic sensing element for barometric pressure is factory calibrated and it does not require any lifetime recalibration. A unique capacitive element is used for measuring relative Humidity while the temperature is measured by a band gap sensor. Both sensors are seamlessly coupled to a 12-bit analog to digital-converter. This results in superior signal quality. The TSM400-4-CPTH multi-sensor is housed in a slim plastic enclosure. The bottom part of the enclosure is suitable for installation on standard flush-mounted/cavity wall boxes ø68mm, with installation openings on 61 mm. 2. Features · LED indicator for status of communication; · Long-term stability based on digital signal processing; · Self-calibration on fresh air for CO2 measurements; · RS-485 interface carrying up to 32 nodes; · Changeable bitrate and other communication parameters; · Firmware update via the interface. 3. Applications · Environmental quality monitoring and assessment for offices · CO2 pollution monitoring · Server room and data centers humidity and temperature monitoring · Smart ventilation systems · CO2, humidity, and temperature monitoring in building management systems (BMS) 4. Specifications · Physical characteristics Dimensions: 81 x 81 x 30 mm Weight: 66 g · Environmental limits Operating temperature range: -20 to 60°C Operating relative humidity range: 5 to 95% (non-condensing) Storage temperature range: -20 to 60°C Storage relative humidity range: 5 to 95% (non-condensing) Ingress protection: IP20 · Power requirements Operating voltage range (including -15/+20% according to IEC 62368-1): 4.5 to 26 VDC Current consumption: 25 mA@5VDC (Peak: 150 mA@5VDC) TSM400-4-CPTH_R1.0 August 2022 Page 2 · CO2 measurements Range: 400 to 5000 ppm Accuracy: ± (40 ppm + 5 %) Resolution: 1 ppm Calibration: Automatic, if the sensor is exposed to fresh air for more than 30 minutes. · Pressure measurements Range: 10 to 1200 hPa Accuracy (min): ±1.5 (25°C, 750 hPa) Accuracy (max): ±2.5 (-20°C to + 85°C, 300 to 1100 hPa) Resolution: 1 hPa · Humidity measurements Accuracy (min): ±3.0 %RH (in 20 to 80 %RH range) Accuracy (max): ±5.0 %RH (in 5 to 95 %RH range) Resolution: 0.1 %RH Recommended operating range is 20% to 80% RH (non-condensing) over 10 °C to 60 °C Prolonged operation beyond these ranges may result in a shift of sensor reading, with slow recovery time. · Temperature measurements Accuracy (min): ±0.4 °C (in -10 to +60°C range) Accuracy (max): ±0.6 °C (in -20 to +60°C range) Resolution: 0.1 °C · Warranty Warranty period: 3 years 5. Pinout Pin 1-W +5÷30V GND A+ BTERM Description Not used Positive power supply Ground (negative) supply Line A+ of RS-485 Line B- of RS-485 For termination, connect to B- UTP wires color Brown/White Tracer Brown Blue/White Tracer Blue 6. Installation Two-Wire MODBUS definition according to modbus.org: "A MODBUS solution over a serial line should implement a "Two-Wire" electrical interface in accordance with EIA/TIA-485 standard. On such a "Two-Wire" topology, at any time one driver only has the right for transmitting. In fact, a third conductor must also interconnect all the devices of the bus - the common." TSM400-4-CPTH_R1.0 August 2022 Page 3 Attention: For proper operation of the interface, terminators (120 ohms resistors) must be installed at both ends of the bus. The device has a built-in 120-ohm resistor and to terminate the line, "B-" and "TERM" must be shortened. A daisy-chained (linear) topology for multiple sensors should be used. UTP/FTP cables are mandatory for interconnection. 7. Installation tips The location and the mounting position of the sensor have a direct effect on the accuracy of the measurement. The tips below will ensure good measuring results: · Sensor shall be installed about 1.2-1.4 m above the floor; · To avoid solar radiation, the sensor should not be installed next to windows or directly in the sunlight; · Sensors shall be installed in a place with sufficient air circulation. TSM400-4-CPTH sensor is intended for installation on a cavity wall box with 68mm diameter and 61 mm screw spacing. TSM400-4-CPTH_R1.0 August 2022 Page 4 8. Status indicator The status of the device is shown by a single LED, located inside the box: · If the LED blinks for a period of 1 second, the sensor works properly; · If the LED blinks for a period of 3 seconds, there isn`t communication with the controller; · If LED doesn`t blink, there isn`t a power supply. 9. Factory default settings Disconnect the sensor from the bus (switch off the power supply). Press and hold the "config" button. Don't release the button, connecting the sensor to the bus (switch on the power supply). The "status" LED will be ON for 3 seconds and after this will flash for 7 seconds. After the 10-th second the LED will be ON. Release the button. The sensor will restart with factory default settings. 10. Firmware update The firmware of the sensor can be updated with a Teracom controller which supports MODBUS RTU or MBRTU-Config software. For more details ask your dealer. 11.Modbus address table Register name RS-485 address Baud rate* Parity, data, stop bits * Data order Sub-family number FW version Vendor URL Float test value (MSWF) Float test value (LSWF) Signed integer test value Signed integer test value (MSWF) Signed integer test value (LSWF) Unsigned integer test value Unsigned integer test value (MSWF) Unsigned integer test value (LSWF) Temperature °C Humidity %RH Dew point °C CO2, ppm Pressure, hPa Temperature °C Humidity %RH R/W FC R/W 03/06 R/W 03/06 R/W 03/06 R/W 03/06 R 3 R 3 R 3 R 3 R 3 R 3 R 3 R 3 R 3 R 3 R 3 R 3 R 3 R 3 R 3 R 3 R 3 R 3 PDU Address (Decimal) 10 11 Logical Address (Decimal) 40011 40012 Offset (Decimal) 40001 40001 Data size 16-bit uns. integer 16-bit uns. integer Default 1 19200 12 40013 40001 16-bit uns. integer 1 13 40014 40001 16-bit uns. integer 1 14 40015 40001 16-bit uns. integer 1 15 40016 40001 16-bit uns. integer 16 40017 40001 64 bytes UTF-8 82 40083 40001 32-bit float 84 40085 40001 32-bit float 86 40087 40001 16-bit sig. integer 87 40088 40001 32-bit sig. integer Valid values 1-247 2400, 4800, 9600, 19200, 38400, 57600 1=E81, 2=O81, 3=N81 1=MSWF (MSW, LSW) 2=LSWF (LSW, MSW) 0xC9 teracomsystems.com -9.9(0xC11E6666) -9.9(0xC11E6666) -999(0xFC19) -99999(0xFFFE7961) 89 40090 40001 32-bit sig. integer -99999(0xFFFE7961) 91 40092 40001 16-bit uns. integer 92 40093 40001 32-bit uns. integer 999(0x03E7) 99999(0x0001869F) 94 40095 40001 32-bit uns. integer 99999(0x0001869F) 100 40101 40001 32-bit float 102 40103 40001 32-bit float 104 40105 40001 32-bit float 106 40107 40001 32-bit float 108 40109 40001 32-bit float 200 40201 40001 32-bit float 202 40203 40001 32-bit float TSM400-4-CPTH_R1.0 August 2022 Page 5 Dew point °C R 3 CO2, ppm R 3 Pressure, mmHg R 3 Temperature °F R 3 Humidity %RH R 3 Dew point °F R 3 CO2, ppm R 3 Pressure, hPa R 3 Temperature °F R 3 Humidity %RH R 3 Dew point °F R 3 CO2, ppm R 3 Pressure, mmHg R 3 Temperature °C x 100 R 3 Humidity %RH x 100 R 3 Dew point °C x 100 R 3 CO2, ppm Pressure, hPa R 3 R 3 Temperature °C x 100 R 3 Humidity %RH x 100 R 3 Dew point °C x 100 R 3 CO2, ppm R 3 Pressure High, mmHg x 100 R 3 Pressure Low, mmHg x 100 R 3 Temperature °F x 100 R 3 Humidity %RH x 100 R 3 Dew point °C x 100 R 3 CO2, ppm Pressure, hPa R 3 R 3 Temperature °F x 100 R 3 Humidity %RH x 100 R 3 Dew point °C x 100 R 3 CO2, ppm R 3 Pressure High, mmHg x 100 R 3 Pressure Low, mmHg x 100 R 3 204 206 208 400 402 404 406 408 500 502 504 506 508 600 601 602 603 604 700 701 702 703 704 705 900 901 902 903 904 1000 1001 1002 1003 1004 1005 40205 40207 40209 40401 40403 40405 40407 40409 40501 40503 40505 40507 40509 40601 40602 40603 40604 40605 40701 40702 40703 40704 40705 40706 40901 40902 40903 40904 40905 41001 41002 41003 41004 41005 41006 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 40001 32-bit float 32-bit float 32-bit float 32-bit float 32-bit float 32-bit float 32-bit float 32-bit float 32-bit float 32-bit float 32-bit float 32-bit float 32-bit float 16-bit sig. integer 16-bit uns. integer 16-bit sig. integer 16-bit uns. integer 16-bit uns. integer 16-bit sig. integer 16-bit uns. integer 16-bit sig. integer 16-bit uns. integer 16-bit uns. integer 16-bit uns. integer 16-bit sig. integer 16-bit uns. integer 16-bit sig. integer 16-bit uns. integer 16-bit uns. integer 16-bit sig. integer 16-bit uns. integer 16-bit sig. integer 16-bit uns. integer 16-bit uns. integer 16-bit uns. integer MSWF - Most significant word first - (bits 31 ... 16), (bits 15 ... 0); LSWF - Least significant word first - (bits 15 ... 0), (bits 31 ... 16); PDU address - Actual address bytes used in a Modbus Protocol Data unit A "NaN" value is returned for unavailable floating-point values (e.g. in case of measurement error) * The settings will take effect after restarting the device by power off, power on. 12. Recycling Recycle all applicable material. Do not dispose of with regular household refuse. TSM400-4-CPTH_R1.0 August 2022 Page 6