Murata Library for Cadence AWR Design Environment (Microwave Office)

User Manual

1. About this manual

This manual is intended for users of the design kit, referred to as the "library." This library provides Murata Manufacturing Co., Ltd.'s (Murata) electrical models for MLCC (Multi-Layer Ceramic Capacitor) and RF-inductors. These models are specifically designed for use with Cadence's AWR Design Environment Microwave Office (MWO) software. This manual details the procedures for installing the library and demonstrates how to utilize it within the Schematic window of MWO.

The procedures outlined in this manual are designed to facilitate necessary operations. However, users should be aware that certain contents might exhibit differences depending on their specific operating environment.

2. Operation environment

This manual is based on the following operating environment. Users are also advised to consult the manuals for their relevant equipment and software for environment-specific details.

3. How to install

The installation process involves unzipping the downloaded library files and then placing them into the appropriate directory within the AWR Design Environment installation.

3.1. Unzipping Library Files

Begin by unzipping the downloaded files. The library consists of two main zip archives: murata_lib_mwo_MLCC_****.zip for MLCC components and murata_lib_mwo_Ind_****.zip for RF-inductor components. After unzipping, examine the contents of each archive.

For MLCC components, the unzipped contents typically include a folder named murata_lib_mwo_MLCC, a configuration file murata_cap.xml, a netlist folder, and specific component data files such as eia_capacitor.xml, jis_capacitor.xml, and murata_smt_cap.gds. For RF-inductor components, the unzipped contents include a folder named murata_lib_mwo_Ind, a configuration file murata_ind.xml, a netlist folder, and specific component data files such as eia_inductor.xml, jis_inductor.xml, and murata_smt_ind.gds.

3.2. Placing Files in the Directory

Move the unzipped folders and their associated .xml files into the following directory within your AWR Design Environment installation:

C:\Users\"UserName"\AppData\Local\AWR\Design Environment\16.0\xml\Circuit Elements\

Important Notes:

4. How to use

To utilize the library components, open the relevant category, either murata_cap for MLCCs or murata_ind for RF-inductors, within the Elements browser in AWR Design Environment.

The library offers two types of part numbers for components: EIA and JIS. Users can select and use either standard as per their project requirements.

Elements can be easily placed onto the schematic by performing a drag-and-drop operation from the Elements browser directly onto the schematic canvas.

The process involves locating the desired component (e.g., murata_MLCC or murata_Ind (RF-inductor)) in the Elements browser. Users then drag the component and drop it onto the schematic. The accompanying simulation graph (e.g., Graph 1) visualizes the performance characteristics of the placed component, such as S-parameters (S21, S11) plotted against frequency, typically ranging from 0.1 MHz to 30 GHz. The Status Window provides simulation progress and information.

5. Contact

For any inquiries regarding this library, please visit the following inquiry form on the Murata website:

https://WWW.murata.com/ja-jp/contactform

* AWR, Cadence AWR Design Environment, and Microwave Office are registered trademarks of Cadence Corporation in the United States and other countries.

Models: Library for Cadence AWR Design Environment Microwave Office, Design Environment Microwave Office, Environment Microwave Office, Microwave Office

File Info : application/pdf, 8 Pages, 334.49KB

PDF preview unavailable. Download the PDF instead.

manual mwo s 2408e

References

, Murata Manufacturing Co.,Ltd.

Related Documents

Preview Murata LQM18NN1R0K00# Inductor Datasheet
Product search datasheet for the Murata LQM18NN1R0K00# inductor. Includes specifications, applications, and characteristic data.
Preview Murata LQP02HQ2N2B02# Inductor Datasheet
Datasheet for the Murata LQP02HQ2N2B02# inductor, featuring specifications, applications, and characteristic data. This non-shielded inductor is suitable for consumer equipment.
Preview Murata LQM21NNR10K10# Product Data Sheet
Product data sheet for Murata's LQM21NNR10K10# series of inductors, detailing specifications, applications, and characteristic data.
Preview Murata Type 1YM Wi-Fi + Bluetooth Module Hardware Application Note
This hardware application note provides RF and hardware design guidance for Murata's Type 1YM Wi-Fi and Bluetooth module, which is based on the NXP 88W8997 chipset. It details reference design, configuration, performance data, and technical specifications for integration.
Preview Murata 4M Change Notice: LQH3NPN/Z/H_ME Series Production Relocation
Official notification from Murata Manufacturing Co., Ltd. regarding the 4M change for LQH3NPN/Z/H_ME series chip inductors, detailing the production relocation to Malaysia due to earthquake impact and BCP enhancement, with no change to product quality or specifications.
Preview Murata 2CX Installation Manual: Land Pattern, PIN Layout, Supply Voltage, Antenna
Installation guide for the Murata 2CX module, detailing land pattern, PIN layout, supply voltage specifications, and antenna design considerations. Includes FCC and IC identification numbers.
Preview Murata MEJ2 Series: 5.2kVDC Isolated 2W DC-DC Converters Datasheet
Murata Power Solutions presents the MEJ2 Series datasheet, featuring 5.2kVDC isolated 2W DC-DC converters in a SIP package. These medically approved converters (UL60950, ES60601-1) offer high isolation and reliability for industrial and medical applications.
Preview Murata NMV1 Series: 3kVDC Isolated 1W Single Output DC-DC Converters Datasheet
Explore the Murata NMV1 Series, a range of 3kVDC isolated 1W single output DC-DC converters designed for extended industrial temperature ranges. This datasheet details specifications, features, and application notes for reliable power solutions.