User Manual for PCE Instruments models including: PCE-PTH 10 Thermo Hygrometer, PCE-PTH 10, Thermo Hygrometer, Hygrometer
© PCE Instruments Contents 1 Safety notes..... 1 2 Specifications..... 2
PCE Instruments - Thermo-Hygrometer PCE-PTH 10 - Hengrythm Sdn Bhd
File Info : application/pdf, 8 Pages, 413.65KB
DocumentDocumentEnglis h User Manual PCE-PTH 10 Thermo-Hygrometer User manuals in various languages (français, italiano, español, português, nederlands, türk, polski, , ) can be found by using our product search on: www.pce-instruments.com Last change: 20 January 2022 v1.0 © PCE Instruments Contents 1 Safety notes ........................................................................................... 1 2 Specifications ........................................................................................ 2 3 Delivery scope ....................................................................................... 2 4 Device description ................................................................................ 3 5 Display description ............................................................................... 4 6 Switching the meter on and off ........................................................... 4 7 Set units ................................................................................................. 4 8 MIN / MAX / normal measuring mode.................................................. 5 9 Insert or replace battery ....................................................................... 5 10 Contact................................................................................................. 5 11 Disposal ................................................................................................. 5 © PCE Instruments 1 Safety notes Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty. · The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter. · The instrument may only be used if the environmental conditions (temperature, relative humidity, ...) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture. · Do not expose the device to shocks or strong vibrations. · The case should only be opened by qualified PCE Instruments personnel. · Never use the instrument when your hands are wet. · You must not make any technical changes to the device. · The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents. · The device must only be used with accessories from PCE Instruments or equivalent. · Before each use, inspect the case for visible damage. If any damage is visible, do not use the device. · Do not use the instrument in explosive atmospheres. · The measurement range as stated in the specifications must not be exceeded under any circumstances. · Non-observance of the safety notes can cause damage to the device and injuries to the user. We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of business. If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual. © PCE Instruments 1 2 Specifications Temperature Measurement range Resolution Measurement accuracy Humidity Measurement range Resolution Measurement accuracy Further specifications Units Functions Measurement rate Power supply Power consumption Operating conditions Storage conditions Dimensions Weight 3 Delivery scope 1 x thermo-hygrometer PCE-PTH 10 1 x 1.5 V LR44 battery 1 x user manual -10 ... 50 °C / 14 ... 122 °F 0.1 °C / 32.18 °F ±1.0 °C / 33.8 °F 20 ... 90 % RH 1 % RH ±15 % RH °C, °F Normal measuring mode, MIN / MAX 1 value every seconds 10 1.5 V, LR44, battery <10 µA -10 ... 50 °C / 14 ... 122 °F, <90 % RH, non-condensing -10 ... 60 °C / 14 ... 140 °F, <90 % RH, non-condensing 138 x 27 x 19 mm / 5.4 x 1.0 x 0.7" 40 g / 1.4 oz © PCE Instruments 2 4 Device description Front view Rear view No. Description 1 Temperature and humidity sensor 2 Display 3 Unit key to select between °C and °F 4 MIN / MAX key to display the highest and lowest measured value 5 Battery compartment and retaining clip 6 On and off switch © PCE Instruments 3 5 Display description No. Description 1 Temperature reading 2 Humidity reading Display RH % MAX MIN °C °F Description Relative humidity Unit for relative humidity The values displayed are the highest measured values The values displayed are the lowest measured values Unit for degrees Celsius Unit for degrees Fahrenheit 6 Switching the meter on and off To turn the meter on and off, press the switch on the back of the meter. 7 Set units To select between the units °C and °F, press the unit key. © PCE Instruments 4 8 MIN / MAX / normal measuring mode After switching on the meter, the measurement is recorded directly. At the same time, the highest and lowest measured values are saved in the background. To see these values, repeatedly press the "MIN / MAX" key on the meter until "MAX" is displayed for the highest measured value or "MIN" for the lowest measured value. If nothing is displayed, you are in normal measuring mode. Note: If no entry is made, the meter automatically switches back to normal measuring mode after 8 seconds. As soon as the meter is switched off, the memory is cleared. 9 Insert or replace battery To insert or replace the battery, first switch off the meter. Open the battery compartment on the back with a Phillips screwdriver. Now insert a 1.5 V LR44 battery into the meter. Make sure that the polarity is correct when inserting the battery. Then close the battery compartment. The meter is ready for use again. 10 Contact If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual. 11 Disposal For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either reuse them or give them to a recycling company which disposes of the devices in line with law. For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations. If you have any questions, please contact PCE Instruments. © PCE Instruments 5 PCE Instruments contact information Germany PCE Deutschland GmbH Im Langel 26 D-59872 Meschede Deutschland Tel.: +49 (0) 2903 976 99 0 Fax: +49 (0) 2903 976 99 29 info@pce-instruments.com www.pce-instruments.com/deutsch United Kingdom PCE Instruments UK Ltd Unit 11 Southpoint Business Park Ensign Way, Southampton Hampshire United Kingdom, SO31 4RF Tel: +44 (0) 2380 98703 0 Fax: +44 (0) 2380 98703 9 info@pce-instruments.co.uk www.pce-instruments.com/english The Netherlands PCE Brookhuis B.V. Institutenweg 15 7521 PH Enschede Nederland Telefoon: +31 (0)53 737 01 92 info@pcebenelux.nl www.pce-instruments.com/dutch France PCE Instruments France EURL 23, rue de Strasbourg 67250 Soultz-Sous-Forets France Téléphone: +33 (0) 972 3537 17 Numéro de fax: +33 (0) 972 3537 18 info@pce-france.fr www.pce-instruments.com/french Italy PCE Italia s.r.l. Via Pesciatina 878 / B-Interno 6 55010 Loc. Gragnano Capannori (Lucca) Italia Telefono: +39 0583 975 114 Fax: +39 0583 974 824 info@pce-italia.it www.pce-instruments.com/italiano United States of America PCE Americas Inc. 1201 Jupiter Park Drive, Suite 8 Jupiter / Palm Beach 33458 FL USA Tel: +1 (561) 320-9162 Fax: +1 (561) 320-9176 info@pce-americas.com www.pce-instruments.com/us Spain PCE Ibérica S.L. Calle Mayor, 53 02500 Tobarra (Albacete) España Tel. : +34 967 543 548 Fax: +34 967 543 542 info@pce-iberica.es www.pce-instruments.com/espanol Turkey PCE Teknik Cihazlari Ltd.ti. Halkali Merkez Mah. Pehlivan Sok. No.6/C 34303 Küçükçekmece - stanbul Türkiye Tel: 0212 471 11 47 Faks: 0212 705 53 93 info@pce-cihazlari.com.tr www.pce-instruments.com/turkish © PCE Instruments 6