RKP-CMU1-SPEC
1U Rack Mountable Control and Monitor Unit

RKP-CMU1
User's Manual

UL62368-1

Bauar t gepruft Sicherheit
egelma ge od o s be wac g
www. tuv.com ID 2000000000
BS EN/EN62368-1

TPTC004

IEC62368-1

 





















       
 
 

 
                                                                                                                                                                                                                                             

 
 

   



  
 
 

  
File Name:RKP-CMU1-SPEC 2022-08-08

1U Rack Mountable Control and Monitor Unit

RKP-CMU1

SPECIFICATION

MODEL

RKP-CMU1

RKP-1U -CMU1

DIGITAL METER

Note.6 Display the DC output voltage, current, and internal temperature

OUTPUT

CONTROL OUTPUT LED INDICATOR

Note.6 PMBus signal Green: Power on

Red:Alarm

RELAY CONTACT

4 user programmable relay, relay contact rating(max.): 30V/1A resistive

VOLTAGE RANGE Note.3 12 ~ 15VDC

INPUT CURRENT

1A/12VDC 0.8A/15VDC

MONITORING INPUTS Note.6 PMBus signal

DISPLAY

LCD 16x2 Alphanumeric Matrix Display / PC Web Page Display

MONITOR

Output Voltage / Load Current / Temperature / Input Voltage

FUNCTION CONTROL

Output Voltage, Current Limit, ON/OFF

COMM. INTERFACE

USB, RS-232, Ethernet

MODEL SUPPORTED

RCP-1600, RCP-2000, DRP-3200

RCP-2000

WORKING TEMP.

Note.1 -25 ~ +70

ENVIRONMENT

WORKING HUMIDITY STORAGE TEMP., HUMIDITY

20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing

VIBRATION

10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY STANDARDS

EAC TP TC 004 approved, design refer to TUV BS EN/EN62368-1 UL62368-1, CSA C22.2 No. 62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved

SAFETY & WITHSTAND VOLTAGE Note.2 O/P-FG:0.7KVDC

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.7KVDC

EMC (Note 4)

ISOLATION RESISTANCE Note.2 O/P-FG:100M Ohms / 500VDC / 25/ 70% RH

I/P-O/P, I/P-FG,O/P-FG:100M Ohms / 500VDC / 25/ 70% RH

EMC EMISSION

Compliance to BS EN/EN55032 (CISPR32) Conduction Class B, Radiation Class A ; BS EN/EN61000-3-2,-3, EAC TP TC 020

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-1(BS EN/EN50082-2), BS EN/EN55035, light industry level, EAC TP TC 020

OTHERS NOTE

MTBF

671.5K hrs min. Telcordia SR-332 (Bellcore) ; 110.5K hrs min. MIL-HDBK-217F (25)

DIMENSION

147.5*127*41mm (L*W*H)

350.8*483.6*44mm (L*W*H)

PACKING

0.8Kg; 16pcs/13.8Kg/0.79CUFT

4.4Kg; 3pcs/14.2Kg/2.67CUFT











http://www.meanwell.com) 



https://www.meanwell.com/serviceDisclaimer.aspx

File Name:RKP-CMU1-SPEC 2022-08-08

1U Rack Mountable Control and Monitor Unit

RKP-CMU1

Function Manual

1.Communication interface  RKP-CMU1 can control and monitor parameters of power units via PMBus communication, and PC can manage the whole system by using USB, RS232, or Ethernet to connect to RKP-CMU1.  PMBus: RKP-CMU1 supports PMBus Rev. 1.1 with maximum 100KHz bus speed, allowing information reading, status monitoring and output trimming. For details, please refer to the Installation Manual.
USB

PMBus

RS-232

Ethernet

2.Monitoring and control RKP-CMU1 can monitor parameters of power units such as output voltage, output current, internal temperature, status, serial number, and firmware version. It also can turn power units on/off together or separately by using "ON/OFF" pin in CN500 or PMBus "CONTROL" pin in JK1 or PMBus "OPERATION" command, shows below. By using PMBus, output voltage and over load protection of power units are adjustable. Please refer to the Installation Manual.

3.Real time clock, Data Log and Event Log RKP-CMU1 has a build-in real time clock data to display actual date/time and for log time stamp. The data logger is designed to store operating data when the systems works. It has 1000 recodes and the interval of log is programmable from 1 to 60 minutes. The event log store system condition when alarm occur and remove. There are 600 records in event log.

4.Programmable relay There are 4 relays and each relay has normal open, normal close and common contact in terminal block. Their active conditions are programmable for flexible application, like charger and generator control.

Function
Alarm
PSU ON PSU OFF Digital input

Sub-function
1.Any alarm 2.OVP 3.OLP 4.Short circuit 5.OTP 6.High Temperature 7.AC fail 8.Fan lock 9.PMBus error
1.Immediately
2.Delay
1.Immediately
2.Delay
D-IN1 ~ D-IN4

PSU

Parameter

N/A

N/A

PSU0~ 31 PSU0~ 31
N/A

0 sec. 1 ~ 600 sec. 0 sec. 1 ~ 600 sec. N/A

File Name:RKP-CMU1-SPEC 2022-08-08



1U Rack Mountable Control and Monitor Unit

Mechanical Specification (Single Unit)

78

40.9

2-M3 L=6mm

1

1

147.5

18

JK500

1

8

RKP-CMU1
Case No. 959A Unit:mm
41 Fig1
1 2

Ethernet DC IN

SK100

CN503
1357 2468

127

12

TB4

RY1 RY2 RY3 RY4

5

9

CN502

6

1

JK1 RS-232 1

8

1

1

8

23

78
2-M3 L=6mm
1
78

40.9
1
40.9

71

2-M3 L=6mm BOTTOM VIEW

 Mounting Instruction

Hole No. Recommended Screw Size

1

M3

MAX. Penetration Depth L 6mm

Recommended mounting torque 6~8Kgf-cm

Mounting Surface

Chassis of RKP-CMU1

Mounting Screw File Name:RKP-CMU1-SPEC 2022-08-08

1U Rack Mountable Control and Monitor Unit
Mechanical Specification (Rack System)

RKP-CMU1
Case No. 959D Unit:mm

RKP-1UT-CMU1 RKP-1UI-CMU1

B L N FG B

ADDRESS SWITCH
10 8.2 ADDRESS SWITCH

L N FG

A


ADDRESS SWITCH
10 8.2 ADDRESS SWITCH

_

_

A

IEC320-C20

IEC320-C20 440

14
+

14
+

1

1

Fig1

14

25

1

13

CN500 SK100 TB4

RY1 RY2 RY3 RY4

DC IN

25

13

Ethernet

1357 2468

JK1 RS-232

8

1

JK500 CN503 CN502

CN500 SK100 TB4

RY1 RY2 RY3 RY4

DC IN

25

13

Ethernet

1357 2468

JK1 RS-232

8

1

JK500 CN503 CN502

Fig2

1 2
Fig3

8

1

1

8

Mounting Bracket

SVR1

SVR1

125

125

350.8

3-M5 L=6mm 3-M5 L=6mm

125

125

50

50

24

44

7.1 7

22 46
Module B 10.2
DC OK

Air flow direction Module A

DC OK 466.1 483.6

7.42 29.48

22 File Name:RKP-CMU1-SPEC 2022-08-08

1U Rack Mountable Control and Monitor Unit

RKP-CMU1

 IN/OUT Connector Pin No. Assignment(CN500) : D-Type Right Angle 25 positions

Pin No. 1,7 2,8 3,9 4,10 5,11 6,12 13
14
15 16~21
22
23 24 25

Function ON/OFF AC-OK DC-OK
PV T-ALARM FAN FAIL +5V-AUX
+12V-AUX
GND-AUX N.C. +S
-S +V(signal) -V(signal)

Description Each unit can separately turn the output on and off by electrical signal or dry contact between ON/OFF A,B(pin 1,7) and +5V-AUX(pin 13). Short: ON, Open:OFF. (Note.2) Low : When the input voltage is 87Vrms. High : when the input voltage in 75Vrms. (Note.2) High : When the Vout 80±5%. Low : When Vout 80±5%. (Note.2) Connection for output voltage trimming. The voltage can be trimmed within its defined range. (Note.1)
High : When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm. Low : When the internal temperature (TSW1 or TSW2 short) under the limit temperature. (Note.2)
High : When the internal fan fail. Low : When the internal fan is normal. (Note.2)
Auxiliary voltage output, 4.5 ~ 5.5V, referenced to GND-AUX (pin 15). The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by the remote ON/OFF control.
Auxiliary voltage output, 10.8 ~ 13.2V, referenced to GND-AUX (pin 15). The maximum load current is 0.8A. This output has the built-in "Oring diodes" and is not controlled by the remote ON/OFF control. Auxiliary voltage output GND. The signal return is isolated from the output terminals (+V & -V). Not used.
Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V.
Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. Positive output voltage. For local sense use only, can't be connected directly to the load. Negative output voltage. For local sense use only, can't be connected directly to the load.

 IN/OUT Connector Pin No. Assignment(JK1) : RJ45 8 positions

Pin No. 1,2 3 4 5 6 7 8

Function DA,DB
-V(signal) CONTROL
NC SDA SCL GND-AUX

Description Differential digital signal for parallel control. (Note.1) Negative output voltage. For parallel control, can't be connected directly to the load. Remote ON/OFF control pin used in the PMBus interface. (Note.2) Not use. Serial Data used in the PMBus interface. (Note.2) Serial Clock used in the PMBus interface. (Note.2) Auxiliary voltage output GND. The signal return is isolated from the output terminals (+V & -V).

Note.1: Non-isolated signal, referenced to -V(signal). Note.2: Isolated signal, referenced to GND-AUX.

 IN/OUT Connector Pin No. Assignment(CN502) : D-type Male 9 positions

Pin No. 1,4,6,7,8,9
2 3 4

Function NC RXD TXD
GND-FG

Description Not used. Data receiving pin of RS-232 interface. Data transmitting pin of RS-232 interface. RS-232 common GND. This signal connects to FG and isolated from -V and GND-AUX.

 IN/OUT Connector Pin No. Assignment(CN503) : HRS DF11-8DP-2DS or equivalent

Pin No. 1,3,5,7 2,4,6,8

Function D-IN1 D-IN2 D-IN3 D-IN4
GND-FG

Description
The isolated digital input signal and referenced to GND-FG. Open from GND-FG or +5V : Logic "1" input to RKP-CMU1 short to GND-FG or 0V : Logic "0" input to RKP-CMU1
Common GND for D-IN. This signal connects to FG and isolated from -V and GND-AUX.

 IN/OUT Connector Pin No. Assignment(JK500) : RJ45 8 position

Pin No. 1,2 3,6
4,5,7,8

Function TX+/TXRX+/RX-
NC

Description Transmit data used in the Ethernet interface. Receive data used in the Ethernet interface. Not used.

File Name:RKP-CMU1-SPEC 2022-08-08

1U Rack Mountable Control and Monitor Unit

 IN/OUT Connector Pin No. Assignment(TB4) : DECA MX422-25412 or equivalent

Pin No. 1,4,7,10 2,5,8,11 3,6,9,12

Function Description Relay-NO Normal-open contact of programmable relay. Relay-NC Normal-close contact of programmable relay. Relay-COM Common for NO/NC contact.

Note: Relay contact rating (max.) : 30Vdc/1A resistive.

 IN/OUT Connector Pin No. Assignment(SK100): Schurter 4840.2201 or equivalent

Pin No. 1 2

Function +VIN -VIN

Description Positive input voltage for RKP-CMU1. Negative input voltage for RKP-CMU1.

RKP-CMU1

File Name:RKP-CMU1-SPEC 2022-08-08

