Owner's Manual for MEAN WELL models including: RKP-CMU1 1U Rack Mountable Control and Monitor Unit, RKP-CMU1, 1U Rack Mountable Control and Monitor Unit, Mountable Control and Monitor Unit, Control and Monitor Unit, Monitor Unit
Мощные системы питания от MEAN WELL заказать в ИНЕЛСО. СПб
Мощные системы питания MEAN WELL от официального дистрибьютора
File Info : application/pdf, 7 Pages, 962.63KB
DocumentDocument1U Rack Mountable Control and Monitor Unit RKP-CMU1 User's Manual UL62368-1 Bauar t gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 BS EN/EN62368-1 TPTC004 IEC62368-1 File Name:RKP-CMU1-SPEC 2022-08-08 1U Rack Mountable Control and Monitor Unit RKP-CMU1 SPECIFICATION MODEL RKP-CMU1 RKP-1U -CMU1 DIGITAL METER Note.6 Display the DC output voltage, current, and internal temperature OUTPUT CONTROL OUTPUT LED INDICATOR Note.6 PMBus signal Green: Power on Red:Alarm RELAY CONTACT 4 user programmable relay, relay contact rating(max.): 30V/1A resistive VOLTAGE RANGE Note.3 12 ~ 15VDC INPUT CURRENT 1A/12VDC 0.8A/15VDC MONITORING INPUTS Note.6 PMBus signal DISPLAY LCD 16x2 Alphanumeric Matrix Display / PC Web Page Display MONITOR Output Voltage / Load Current / Temperature / Input Voltage FUNCTION CONTROL Output Voltage, Current Limit, ON/OFF COMM. INTERFACE USB, RS-232, Ethernet MODEL SUPPORTED RCP-1600, RCP-2000, DRP-3200 RCP-2000 WORKING TEMP. Note.1 -25 ~ +70 ENVIRONMENT WORKING HUMIDITY STORAGE TEMP., HUMIDITY 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS EAC TP TC 004 approved, design refer to TUV BS EN/EN62368-1 UL62368-1, CSA C22.2 No. 62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved SAFETY & WITHSTAND VOLTAGE Note.2 O/P-FG:0.7KVDC I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.7KVDC EMC (Note 4) ISOLATION RESISTANCE Note.2 O/P-FG:100M Ohms / 500VDC / 25/ 70% RH I/P-O/P, I/P-FG,O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Conduction Class B, Radiation Class A ; BS EN/EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-1(BS EN/EN50082-2), BS EN/EN55035, light industry level, EAC TP TC 020 OTHERS NOTE MTBF 671.5K hrs min. Telcordia SR-332 (Bellcore) ; 110.5K hrs min. MIL-HDBK-217F (25) DIMENSION 147.5*127*41mm (L*W*H) 350.8*483.6*44mm (L*W*H) PACKING 0.8Kg; 16pcs/13.8Kg/0.79CUFT 4.4Kg; 3pcs/14.2Kg/2.67CUFT http://www.meanwell.com) https://www.meanwell.com/serviceDisclaimer.aspx File Name:RKP-CMU1-SPEC 2022-08-08 1U Rack Mountable Control and Monitor Unit RKP-CMU1 Function Manual 1.Communication interface RKP-CMU1 can control and monitor parameters of power units via PMBus communication, and PC can manage the whole system by using USB, RS232, or Ethernet to connect to RKP-CMU1. PMBus: RKP-CMU1 supports PMBus Rev. 1.1 with maximum 100KHz bus speed, allowing information reading, status monitoring and output trimming. For details, please refer to the Installation Manual. USB PMBus RS-232 Ethernet 2.Monitoring and control RKP-CMU1 can monitor parameters of power units such as output voltage, output current, internal temperature, status, serial number, and firmware version. It also can turn power units on/off together or separately by using "ON/OFF" pin in CN500 or PMBus "CONTROL" pin in JK1 or PMBus "OPERATION" command, shows below. By using PMBus, output voltage and over load protection of power units are adjustable. Please refer to the Installation Manual. 3.Real time clock, Data Log and Event Log RKP-CMU1 has a build-in real time clock data to display actual date/time and for log time stamp. The data logger is designed to store operating data when the systems works. It has 1000 recodes and the interval of log is programmable from 1 to 60 minutes. The event log store system condition when alarm occur and remove. There are 600 records in event log. 4.Programmable relay There are 4 relays and each relay has normal open, normal close and common contact in terminal block. Their active conditions are programmable for flexible application, like charger and generator control. Function Alarm PSU ON PSU OFF Digital input Sub-function 1.Any alarm 2.OVP 3.OLP 4.Short circuit 5.OTP 6.High Temperature 7.AC fail 8.Fan lock 9.PMBus error 1.Immediately 2.Delay 1.Immediately 2.Delay D-IN1 ~ D-IN4 PSU Parameter N/A N/A PSU0~ 31 PSU0~ 31 N/A 0 sec. 1 ~ 600 sec. 0 sec. 1 ~ 600 sec. N/A File Name:RKP-CMU1-SPEC 2022-08-08 1U Rack Mountable Control and Monitor Unit Mechanical Specification (Single Unit) 78 40.9 2-M3 L=6mm 1 1 147.5 18 JK500 1 8 RKP-CMU1 Case No. 959A Unit:mm 41 Fig1 1 2 Ethernet DC IN SK100 CN503 1357 2468 127 12 TB4 RY1 RY2 RY3 RY4 5 9 CN502 6 1 JK1 RS-232 1 8 1 1 8 23 78 2-M3 L=6mm 1 78 40.9 1 40.9 71 2-M3 L=6mm BOTTOM VIEW Mounting Instruction Hole No. Recommended Screw Size 1 M3 MAX. Penetration Depth L 6mm Recommended mounting torque 6~8Kgf-cm Mounting Surface Chassis of RKP-CMU1 Mounting Screw File Name:RKP-CMU1-SPEC 2022-08-08 1U Rack Mountable Control and Monitor Unit Mechanical Specification (Rack System) RKP-CMU1 Case No. 959D Unit:mm RKP-1UT-CMU1 RKP-1UI-CMU1 B L N FG B ADDRESS SWITCH 10 8.2 ADDRESS SWITCH L N FG A ADDRESS SWITCH 10 8.2 ADDRESS SWITCH _ _ A IEC320-C20 IEC320-C20 440 14 + 14 + 1 1 Fig1 14 25 1 13 CN500 SK100 TB4 RY1 RY2 RY3 RY4 DC IN 25 13 Ethernet 1357 2468 JK1 RS-232 8 1 JK500 CN503 CN502 CN500 SK100 TB4 RY1 RY2 RY3 RY4 DC IN 25 13 Ethernet 1357 2468 JK1 RS-232 8 1 JK500 CN503 CN502 Fig2 1 2 Fig3 8 1 1 8 Mounting Bracket SVR1 SVR1 125 125 350.8 3-M5 L=6mm 3-M5 L=6mm 125 125 50 50 24 44 7.1 7 22 46 Module B 10.2 DC OK Air flow direction Module A DC OK 466.1 483.6 7.42 29.48 22 File Name:RKP-CMU1-SPEC 2022-08-08 1U Rack Mountable Control and Monitor Unit RKP-CMU1 IN/OUT Connector Pin No. Assignment(CN500) : D-Type Right Angle 25 positions Pin No. 1,7 2,8 3,9 4,10 5,11 6,12 13 14 15 16~21 22 23 24 25 Function ON/OFF AC-OK DC-OK PV T-ALARM FAN FAIL +5V-AUX +12V-AUX GND-AUX N.C. +S -S +V(signal) -V(signal) Description Each unit can separately turn the output on and off by electrical signal or dry contact between ON/OFF A,B(pin 1,7) and +5V-AUX(pin 13). Short: ON, Open:OFF. (Note.2) Low : When the input voltage is 87Vrms. High : when the input voltage in 75Vrms. (Note.2) High : When the Vout 80±5%. Low : When Vout 80±5%. (Note.2) Connection for output voltage trimming. The voltage can be trimmed within its defined range. (Note.1) High : When the internal temperature (TSW1 or TSW2 open) exceeds the limit of temperature alarm. Low : When the internal temperature (TSW1 or TSW2 short) under the limit temperature. (Note.2) High : When the internal fan fail. Low : When the internal fan is normal. (Note.2) Auxiliary voltage output, 4.5 ~ 5.5V, referenced to GND-AUX (pin 15). The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by the remote ON/OFF control. Auxiliary voltage output, 10.8 ~ 13.2V, referenced to GND-AUX (pin 15). The maximum load current is 0.8A. This output has the built-in "Oring diodes" and is not controlled by the remote ON/OFF control. Auxiliary voltage output GND. The signal return is isolated from the output terminals (+V & -V). Not used. Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. Positive output voltage. For local sense use only, can't be connected directly to the load. Negative output voltage. For local sense use only, can't be connected directly to the load. IN/OUT Connector Pin No. Assignment(JK1) : RJ45 8 positions Pin No. 1,2 3 4 5 6 7 8 Function DA,DB -V(signal) CONTROL NC SDA SCL GND-AUX Description Differential digital signal for parallel control. (Note.1) Negative output voltage. For parallel control, can't be connected directly to the load. Remote ON/OFF control pin used in the PMBus interface. (Note.2) Not use. Serial Data used in the PMBus interface. (Note.2) Serial Clock used in the PMBus interface. (Note.2) Auxiliary voltage output GND. The signal return is isolated from the output terminals (+V & -V). Note.1: Non-isolated signal, referenced to -V(signal). Note.2: Isolated signal, referenced to GND-AUX. IN/OUT Connector Pin No. Assignment(CN502) : D-type Male 9 positions Pin No. 1,4,6,7,8,9 2 3 4 Function NC RXD TXD GND-FG Description Not used. Data receiving pin of RS-232 interface. Data transmitting pin of RS-232 interface. RS-232 common GND. This signal connects to FG and isolated from -V and GND-AUX. IN/OUT Connector Pin No. Assignment(CN503) : HRS DF11-8DP-2DS or equivalent Pin No. 1,3,5,7 2,4,6,8 Function D-IN1 D-IN2 D-IN3 D-IN4 GND-FG Description The isolated digital input signal and referenced to GND-FG. Open from GND-FG or +5V : Logic "1" input to RKP-CMU1 short to GND-FG or 0V : Logic "0" input to RKP-CMU1 Common GND for D-IN. This signal connects to FG and isolated from -V and GND-AUX. IN/OUT Connector Pin No. Assignment(JK500) : RJ45 8 position Pin No. 1,2 3,6 4,5,7,8 Function TX+/TXRX+/RX- NC Description Transmit data used in the Ethernet interface. Receive data used in the Ethernet interface. Not used. File Name:RKP-CMU1-SPEC 2022-08-08 1U Rack Mountable Control and Monitor Unit IN/OUT Connector Pin No. Assignment(TB4) : DECA MX422-25412 or equivalent Pin No. 1,4,7,10 2,5,8,11 3,6,9,12 Function Description Relay-NO Normal-open contact of programmable relay. Relay-NC Normal-close contact of programmable relay. Relay-COM Common for NO/NC contact. Note: Relay contact rating (max.) : 30Vdc/1A resistive. IN/OUT Connector Pin No. Assignment(SK100): Schurter 4840.2201 or equivalent Pin No. 1 2 Function +VIN -VIN Description Positive input voltage for RKP-CMU1. Negative input voltage for RKP-CMU1. RKP-CMU1 File Name:RKP-CMU1-SPEC 2022-08-08