Combi-kit Extension Sets
Models: VKS01COMBI, VKS02COMBI, VKS03COMBI, VKS04COMBI
These Combi-kits are designed to expand the Hager 'vision' system, providing multiple circuit breakers and associated components for electrical installations.
Included Components:
- Residual Current Device (RCD): ALS 2p/30mA (Model: CDA540G)
- Circuit Breakers: 1, 2, 3, or 4 units, 16A, B-characteristic
- QuickConnect System: (Model: MKS516)
- Wiring: Brown wire (6 mm² cross-section, 250 mm length), Blue wire (6 mm² cross-section, 250 mm length)
- Connecting Rail: (Model: KB4FN)
- Shielding: (Model: KZ059)
Note: The set includes the KB4FN connecting rail, which supports maximum extension up to 4 final circuits. Wiring should be connected directly to the main switch.
Installation Overview and Visuals:
The 'vision' system components are designed for modular installation within electrical distribution boards. The following illustrates general installation principles and specific product views.
Diagram 1: General Safety Warnings
⚠️ [Electrical Hazard symbol] - Indicates potential electrical danger. Always follow safety procedures.
⚠️ [Person with tool symbol] - Shows a person performing electrical work, emphasizing the need for caution and proper tools.
⚠️ [House with warning symbol] - Suggests that installation should be done in a safe environment, possibly within a building structure.
Product Visuals:
Images display the VKS01COMBI, VKS02COMB, VKS03COMBI, and VKS04COMBI units, showing their physical layout and terminal connections.
Diagram 2: Installation Steps
Step 1: Shows a component being inserted into a mounting rail or slot, with a label "boven." (top) indicating orientation. The action is accompanied by a "klik!" (click) sound, signifying secure attachment.
Step 2: Illustrates connecting wires. The image shows a hand manipulating a wire into a terminal block. The "klik!" sound is again indicated, suggesting the wire is securely fastened.
Extension Sets VKS15S and VKS151S
Models: VKS15S, VKS151S
These sets include Residual Current Devices (RCDs) and associated wiring and accessories for the Hager 'vision' system.
VKS15S Components:
- 2x Residual Current Device (RCD): 1p+N, 30mA, 40A (Model: CDA540G)
- 2x Wiring: Brown wire (6 mm² cross-section, 250 mm length), Blue wire (6 mm² cross-section, 250 mm length)
- 2x Connecting Rail
- 2x Shielding
- Associated components: KB4FN, KZ059
VKS151S Components:
- 1x Residual Current Device (RCD): 1p+N, 30mA, 40A (Model: CDA540G)
- Wiring: Brown wire (6 mm² cross-section, 250 mm length), Blue wire (6 mm² cross-section, 250 mm length)
- Connecting Rail
- Shielding
- Associated components: KB4FN, KZ059
Note: The set includes the KB4FN connecting rail, which supports maximum extension up to 4 final circuits. Wiring should be connected directly to the main switch.
Installation Overview and Visuals:
Diagram 1: General Safety Warnings
Similar to previous sets, this includes warnings for electrical hazards, proper tool usage, and safe installation environments.
Product Visuals:
Images show the VKS15S and VKS151S units, highlighting their modular design and connection points.
Diagram 2: Installation Steps
Step 1: Shows a component being attached to a mounting rail, indicated by "bovenzijde" (top side) and a "klik!" (click) sound for secure fitting.
Step 2: Depicts the use of a [Pozidriv PZ 2 screwdriver] to tighten a connection, with a torque specification "M = 2,6Nm" indicated.
Step 3: Illustrates wiring connections. Brown wire (6 mm²) and blue wire (6 mm²) are shown being connected to terminals. The diagram also shows the KB4FN component, likely a connecting rail or accessory.
Extension Sets VKS16S and VKS161S
Models: VKS16S, VKS161S
These sets feature 3-phase + neutral Residual Current Devices (RCDs) for expanded electrical protection within the Hager 'vision' system.
VKS16S Components:
- 2x Residual Current Device (RCD): 3p+N, 30mA, 40A (Model: CDS440G)
- Connecting Rail: 4p 63A, 8 modules
- Wiring: 3x Brown wire (6 mm² cross-section, 250 mm length), 1x Blue wire (6 mm² cross-section, 250 mm length)
- Associated component: KDN463E
VKS161S Components:
- 1x Residual Current Device (RCD): 3p+N, 30mA, 40A (Model: CDS440G)
- Wiring: 3x Brown wire (6 mm² cross-section, 250 mm length), 1x Blue wire (6 mm² cross-section, 250 mm length)
- Associated component: KDN463E
Note: Wiring should be connected directly to the main switch.
Installation Overview and Visuals:
Diagram 1: General Safety Warnings
Standard safety warnings are displayed, including electrical hazard, proper tool usage, and safe installation practices.
Product Visuals:
Images show the VKS16S and VKS161S units, illustrating their physical structure and connection interfaces.
Diagram 2: Installation Steps
Step 1: Shows a component being attached to a mounting rail, indicated by "bovenzijde" (top side) and a "klik!" (click) sound for secure fitting.
Step 2: Depicts the use of a [Pozidriv PZ 2 screwdriver] to tighten a connection, with a torque specification "M = 2,6Nm" indicated.
Step 3 & 4: Illustrate wiring connections. Brown wires (6 mm²) and blue wires (6 mm²) are shown being connected to terminals. The diagrams also show the KDN463E component, likely a connecting rail or accessory, and the connection of multiple wires.
Extension Sets VKS01SSG and VKS12SJ
Models: VKS01SSG, VKS12SJ
These sets feature single-pole + neutral installation breakers with different characteristics (B-kar for VKS01SSG, C-kar for VKS12SJ) for the Hager 'vision' system.
VKS01SSG Components:
- Installation Breaker: 1p+N, B-characteristic, 6 kA, 16 A QuickConnect (Model: MKS516)
- Wiring: Brown wire (2.5 mm² cross-section, 170 mm length), Blue wire (2.5 mm² cross-section, 170 mm length)
VKS12SJ Components:
- Installation Breaker: 1p+N, C-characteristic, 6 kA, 16 A QuickConnect (Model: MLS516)
- Wiring: Brown wire (2.5 mm² cross-section, 170 mm length), Blue wire (2.5 mm² cross-section, 170 mm length)
Note: These extension sets are compatible with various 'vision' distributors.
Installation Overview and Visuals:
Diagram 1: General Safety Warnings
Standard safety warnings are displayed, including electrical hazard, proper tool usage, and safe installation practices.
Product Visuals:
Images show the MKS516/MLS516 units, illustrating their physical structure and connection interfaces.
Diagram 2: Installation Steps
Step 1: Shows a component being attached to a mounting rail, indicated by "bovenzijde" (top side) and a "klik!" (click) sound for secure fitting.
Step 2: Depicts the use of a [Pozidriv PZ 2 screwdriver] to tighten a connection, with a torque specification "M = 2,6Nm" indicated.
Step 3 & 4: Illustrate wiring connections. Brown wire (2.5 mm²) and blue wire (2.5 mm²) are shown being connected to terminals. The diagrams also show KB4FN and KB41N components, likely connecting rails or accessories.
Extension Set VKS02SA
Model: VKS02SA
This set includes a 3-phase + neutral power group breaker with a B-characteristic for the Hager 'vision' system.
VKS02SA Components:
- Power Group: 3p+N, 6 kA, B-characteristic, 16 A direct connection (Model: ADA916G)
- Wiring: Brown wire (2.5 mm² cross-section, 170 mm length), Blue wire (2.5 mm² cross-section, 170 mm length)
Note: The HACO RCD (ADA916G) can also be connected to an existing connecting rail.
Installation Overview and Visuals:
Diagram 1: General Safety Warnings
Standard safety warnings are displayed, including electrical hazard, proper tool usage, and safe installation practices.
Product Visuals:
Images show the ADA916G unit, illustrating its physical structure and connection interfaces.
Diagram 2: Installation Steps
Step 1: Shows a component being attached to a mounting rail, indicated by "bovenzijde" (top side) and a "klik!" (click) sound for secure fitting.
Step 2: Depicts the use of a [Pozidriv PZ 2 screwdriver] to tighten a connection, with a torque specification "M = 2,6Nm" indicated. Brown wire (2.5 mm²) and blue wire (2.5 mm²) are shown connected to terminals.
Extension Sets VKS03SF and VKS06SV
Models: VKS03SF, VKS06SV
These sets include dual single-pole + neutral installation breakers, available with 16A QC or 20A rating, for the Hager 'vision' system.
VKS03SF / VKS06SV Components:
- Installation Breaker: 2x(1p+N), B-characteristic, 6kA, 16A QuickConnect (Model: MKS599) OR 2x(1p+N), B-characteristic, 6kA, 20A (Model: MKN598)
- Wiring: 2x Brown wire (2.5 mm² cross-section, 170 mm length), 2x Blue wire (2.5 mm² cross-section, 170 mm length)
Note: These extension sets fit various 'vision' distributors.
Installation Overview and Visuals:
Diagram 1: General Safety Warnings
Standard safety warnings are displayed, including electrical hazard, proper tool usage, and safe installation practices.
Product Visuals:
Images show the MKS599 and MKN598 units, illustrating their physical structure and connection interfaces.
Diagram 2: Installation Steps
Step 1: Shows a component being attached to a mounting rail, indicated by "bovenzijde" (top side) and a "klik!" (click) sound for secure fitting.
Step 2: Depicts wiring connections. Brown wires (2.5 mm²) and blue wires (2.5 mm²) are shown being connected to terminals. A torque specification "M = 2,6Nm" is indicated.
Step 3: Illustrates the use of a [Pozidriv PZ 2 screwdriver] and shows the KB4FN component, likely a connecting rail or accessory.
Extension Sets VKS04SD and VKS14SB
Models: VKS04SD, VKS14SB
These sets include 3-phase + neutral power group or RCD breakers with B-characteristic for the Hager 'vision' system.
VKS04SD Components:
- Power Group: 3p+N, 6 kA, B-characteristic, 16 A direct connection (Model: MBS616E, 3KS, 4KS)
- Wiring: 3x Brown wire (6 mm² cross-section, 250 mm length), 1x Blue wire (6 mm² cross-section, 250 mm length)
VKS14SB Components:
- Residual Current Device (RCD): 3p+N, 6 kA, B-characteristic (Model: ADM416G, 3KS, 4KS)
- Wiring: 3x Brown wire (6 mm² cross-section, 250 mm length), 1x Blue wire (6 mm² cross-section, 250 mm length)
Note: Wiring should be connected directly to the main switch.
Installation Overview and Visuals:
Diagram 1: General Safety Warnings
Standard safety warnings are displayed, including electrical hazard, proper tool usage, and safe installation practices.
Product Visuals:
Images show the VKS04SD/VKS14SB units, illustrating their physical structure and connection interfaces.
Diagram 2: Installation Steps
Step 1: Shows a component being attached to a mounting rail, indicated by "bovenzijde" (top side) and a "klik!" (click) sound for secure fitting.
Step 2: Depicts wiring connections. Brown wire (6 mm²) and blue wire (6 mm²) are shown connected to terminals. A torque specification "M = 2,6Nm" is indicated.
Extension Sets VKS05SK and VKS08SC
Models: VKS05SK, VKS08SC
These sets include 3-phase + neutral power group breakers with QuickConnect, and a connecting rail, for the Hager 'vision' system.
VKS05SK & VKS08SC Components:
- Power Group: 3p+N, B-characteristic, 6kA, 16A QuickConnect (Model: MBS616E) OR 3p+N, C-characteristic, 6kA, 16A QuickConnect (Model: MCS616E)
- Connecting Rail: 4p 63A, 8 modules (Model: KDN463E)
- Wiring: 1x Blue wire (6 mm² cross-section, 125 mm length), 3x Brown wire (2.5 mm² cross-section, 170 mm length)
Note: The set should be connected behind a 4-pole RCD.
Installation Overview and Visuals:
Diagram 1: General Safety Warnings
Standard safety warnings are displayed, including electrical hazard, proper tool usage, and safe installation practices.
Product Visuals:
Images show the VKS05SK/VKS08SC units, illustrating their physical structure and connection interfaces.
Diagram 2: Installation Steps
Step 1: Shows a component being attached to a mounting rail, indicated by "bovenzijde" (top side) and a "klik!" (click) sound for secure fitting.
Step 2: Depicts wiring connections. Blue wire (6 mm²) and brown wires (2.5 mm²) are shown connected to terminals. The KDN463E component is also visible.
Step 3 & 4: Illustrate further wiring and component placement. The diagrams show brown wires (2.5 mm²) and blue wires (6 mm²) being connected.
Step 5: Shows the final connection with a torque specification "M = 2,6Nm" indicated.
Extension Sets VKS07ST and VKG07ST
Models: VKS07ST, VKG07ST
These sets include a bell transformer with a primary switch and associated wiring for the Hager 'vision' system.
VKS07ST / VKG07ST Components:
- Bell Transformer: 8V/1A with primary switch (Models: ST303N, VK85T, VKG71T)
- Wiring: Brown wire (1.5 mm² cross-section), Blue wire (1.5 mm² cross-section); 400 mm length
- Wiring: 2x White wire (1 mm² cross-section); 400 mm length
Note: The bell transformer is primarily connected to an installation breaker behind the RCD. The secondary connection block slides onto the side, top, or bottom of the output opening.
Installation Overview and Visuals:
Diagram 1: General Safety Warnings
Standard safety warnings are displayed, including electrical hazard, proper tool usage, and safe installation practices.
Product Visuals:
Images show the VKS07ST/VKG07ST units, illustrating their physical structure and connection interfaces.
Diagram 2: Installation Steps
Step 1: Shows a component being attached to a mounting rail, indicated by "bovenzijde" (top side) and a "klik!" (click) sound for secure fitting.
Step 2: Depicts wiring connections. Brown wire (1.5 mm²) and blue wire (1.5 mm²) are shown connected to terminals. White wire (1 mm²) is also shown. A torque specification "M = 2,6Nm" is indicated.
Extension Sets VKS09SW and VKS17SN
Models: VKS09SW, VKS17SN
These sets include a socket outlet with earthing contact (VKS09SW) and an emergency light/flashlight (VKS17SN), along with associated wiring, for the Hager 'vision' system.
VKS09SW Components:
- Socket Outlet: With earthing contact, 10-16 A / 250 V QC (Model: SNS016)
- Wiring: Brown wire (1.5 mm² cross-section), Blue wire (1.5 mm² cross-section); 400 mm length
- Wiring: Yellow/green wire (2.5 mm² cross-section); 420 mm length
VKS17SN Components:
- Emergency Light: 230 V, also functions as a flashlight (Model: EE960)
- Wiring: Brown wire (1.5 mm² cross-section); 400 mm length
- Wiring: Blue wire (1.5 mm² cross-section); 400 mm length
Note: The brown and blue wires are connected to an installation breaker behind the RCD.
Installation Overview and Visuals:
Diagram 1: General Safety Warnings
Standard safety warnings are displayed, including electrical hazard, proper tool usage, and safe installation practices.
Product Visuals:
Images show the VKS09SW and VKS17SN units, illustrating their physical structure and connection interfaces.
Diagram 2: Installation Steps
Step 1: Shows a component being attached to a mounting rail, indicated by "bovenzijde" (top side) and a "klik!" (click) sound for secure fitting.
Step 2: Depicts wiring connections. For VKS09SW, brown (1.5 mm²), blue (1.5 mm²), and yellow/green (2.5 mm²) wires are shown. For VKS17SN, brown (1.5 mm²) and blue (1.5 mm²) wires are shown.
Extension Sets VKS13SH, VKS18SR, VKS19SU, and VKS20SM
Models: VKS13SH, VKS18SR, VKS19SU, VKS20SM
These sets include various specialized devices such as ventilation switches, magnetic switches, time switches, and kWh meters for the Hager 'vision' system.
VKS13SH or VKS18SR Components:
- Ventilation Switch: 1p 25A 1m (Model: SBN125) OR Magnetic Switch: 25A 1m 230V (Model: ESC125)
- Wiring: Brown wire (1.5 mm² cross-section), 400 mm length
VKS19SU or VKS20SM Components:
- Time Switch: 1W/16A, 20 steps (Model: EG071) OR kWh Meter: 1 phase 32A (Model: EC050)
- Wiring: Brown wire (1.5 mm² cross-section), 400 mm length
- Wiring: Blue wire (1.5 mm² cross-section), 400 mm length
Note: The brown (and blue) wire(s) are connected to an installation breaker behind the RCD.
Installation Overview and Visuals:
Diagram 1: General Safety Warnings
Standard safety warnings are displayed, including electrical hazard, proper tool usage, and safe installation practices.
Product Visuals:
Images show the VKS13SH, VKS18SR, VKS19SU, and VKS20SM units, illustrating their physical structure and connection interfaces.
Diagram 2: Installation Steps
Step 1: Shows a component being attached to a mounting rail, indicated by "bovenzijde" (top side) and a "klik!" (click) sound for secure fitting.
Step 2: Depicts wiring connections. For VKS13SH/VKS18SR, brown wire (1.5 mm²) is shown. For VKS19SU/VKS20SM, brown wire (1.5 mm²) and blue wire (1.5 mm²) are shown. The diagrams indicate connections to terminals.