User Guide for NoVus models including: TxIsoLoop-1, TxIsoLoop-2, TxIsoLoop 1 Loop Powered Isolators, TxIsoLoop 1, Loop Powered Isolators, Powered Isolators, Isolators

TxIsoLoop

Manual

Transmissor Isolado, TxIsoLoop

NOVUS Automation NOVUS Automation

TxIsoLoop-1 TxIsoLoop-2


File Info : application/pdf, 10 Pages, 434.05KB

PDF preview unavailable. Download the PDF instead.

manual txisoloop v10x i en
TxIsoLoop-1 TxIsoLoop-2
Loop-Powered Isolators
USER GUIDE ­ V1.0x I

NOVUS AUTOMATION

1/10

1. SAFETY ALERTS ...................................................................................................................................................................................................3

2. INTRODUCTION.....................................................................................................................................................................................................4

3. SPECIFICATIONS ..................................................................................................................................................................................................5

4. ELECTRICAL INSTALLATION ...............................................................................................................................................................................6

4.1

ELECTRICAL CONNECTIONS ..................................................................................................................................................................7

4.2

TXISOLOOP-2 ­ SIGNAL SPLITTER FUNCTION .....................................................................................................................................8

4.2.1

ACTIVE CURRENT SIGNAL...........................................................................................................................................................8

4.2.2

PASSIVE CURRENT SIGNAL ........................................................................................................................................................8

4.3

INSTALLATION RECOMMENDATIONS ....................................................................................................................................................8

5.

MECHANICAL INSTALLATION ........................................................................................................................................................................9

6.

WARRANTY....................................................................................................................................................................................................10

NOVUS AUTOMATION

2/10

1. SAFETY ALERTS
The symbols below are used in the device and throughout this manual to draw the user's attention to valuable information related to device safety and use.

CAUTION
Read the manual fully before installing and operating the device.

CAUTION OR HAZARD Risk of electric shock.

ATTENTION
Material sensitive to static charge. Check precautions before handling.

All safety recommendations appearing in this manual must be followed to ensure personal safety and prevent damage to the instrument or system. If the instrument is used in a manner other than that specified in this manual, the device's safety protections may not be effective.

NOVUS AUTOMATION

3/10

2. INTRODUCTION
TxIsoLoop-1 and TxIsoLoop-2 galvanic isolators are devices used for electrical isolation of 0(4)-20 mA current signals. Its purpose is to avoid measurement errors typically found in installations that have problems with electrical potential difference and ground loops These isolators do NOT require an electrical power supply. The energy obtained by passing the electric current through the insulator input actively generates the output current. Features: · Galvanic isolation between input and output. · Models with one or two input/output channels. · The device does not require a power supply. · High accuracy.

NOVUS AUTOMATION

4/10

3. SPECIFICATIONS

FEATURES Input signal Voltage drop - Input/output without protection (Vdrop) Voltage drop - Input/output with protection (Vdrop) Output signal Max. load (RL)
Total accuracy
Minimum operating current Maximum input current Response time Current limit
Electrical isolation
EMC
Work environment
Housing Protection index Wire gauge for connections Recommended torque Terminal enclosure

TXISOLOOP 0(4) to 20 mA (Check minimum current for proper operation)
< 3 Vdc
< 5 Vdc
0(4) to 20 mA 1450 R · 0.2 % @ 0 to 60 °C / RL = 250 R · 0.3 % @ -20 to 75 °C / RL = 250 R > 0.1 mA < 40 mA 2 ms @ RL= 250 R 31 mA · 3000 Vac / 10 seconds · 240 Vac continuous EN 61326-1 (without performance degradation) · Temperature: -20 to 75 °C · Relative humidity: 20 to 90 % ABS (60 %) + PC (40 %) IP40 0.14 a 1.5 mm² 0.8 Nm Polyamide
Table 1 Technical specifications

NOVUS AUTOMATION

5/10

4. ELECTRICAL INSTALLATION
To ensure perfect operation of the TxIsoLoop isolator, the circuit where the isolator input is connected must provide a minimum electrical voltage (V1). You can supply the electrical voltage in two ways: 1. The device that generates the current signal is of the active type (source), where it provides the necessary electrical voltage itself.

Figure 1 TxIsoLoop connections with source type device
With type source devices (transmitters, controllers, etc.), this voltage is provided by the device itself). The minimum voltage value to be supplied by the generator can be calculated using the formula below:

V1 = Vin

Where: Vin = Vdrop + ( Iout(max) x RL) Iin = Iout

2. With sink type devices (2-wire transmitters), the energy is provided by an external power supply in series in the loop, as shown in Figure 2.

Figure 2 Connections on the TxIsoLoop with sink type devices
In this option, the inserted source must provide enough voltage to meet the needs of the current generating device (generator, transmitter, controller, etc.) and the isolator. The minimum voltage value to be supplied by the power supply can be calculated using the formula below:

V1 = Vb + Where: V1= Voltage from the source inserted into the circuit

Vin

Vb= Minimum voltage of the generator

Vin = Vdrop + ( Iout(max) x RL)

Iin = Iout

NOVUS AUTOMATION

6/10

4.1 ELECTRICAL CONNECTIONS
To configure TxIsoLoop-1, use the following wiring diagram:
Figure 3 TxIsoLoop-1 Connections
To configure TxIsoLoop-2, use the following wiring diagram:
Figure 4 TxIsoLoop-2 Connections

NOVUS AUTOMATION

7/10

4.2 TXISOLOOP-2 ­ SIGNAL SPLITTER FUNCTION
If needed, TxIsoLoop-2 can be used as a 4-20 mA signal splitter, as shown in the figures below:
4.2.1 ACTIVE CURRENT SIGNAL

4.2.2 PASSIVE CURRENT SIGNAL

Figure 5 Active current signal

Figure 6 Passive current signal
To duplicate the signal, the two outputs of the device must be connected to a load.
4.3 INSTALLATION RECOMMENDATIONS
· Input signal conductors must run through the plant separately from the supply and output conductors. If possible, in grounded conduits. · The power supply for the electronic instruments must come from a proper instrumentation network. · In control applications, it is essential to consider what can happen when any part of the system fails. · It is recommended to use RC FILTERS (noise suppressors) at contactor coils, solenoids, etc.

NOVUS AUTOMATION

8/10

5. MECHANICAL INSTALLATION
The transmitter is intended for a 35 mm DIN rail mounting.
Figure 7 Isolator dimensions

NOVUS AUTOMATION

9/10

6. WARRANTY
Warranty conditions are available on our website www.novusautomation.com/warranty.

NOVUS AUTOMATION

10/10



References

NOVUS Automation Adobe PDF Library 24.1.135