Instruction Manual for RUNHOOD models including: F3600-US, F3600-US Residential ESS and Portable Power Station, Residential ESS and Portable Power Station, ESS and Portable Power Station, Portable Power Station, Power Station, Station

ZhangGan

User Manual

RUNHOOD POWER INC. F3600-US RESIDENTIAL ESS & PORTABLE POWER STATION 2BB59-F3600-US 2BB59F3600US f3600 us

download (pdf)

F3600-US Residential Ess & Portable Power Station by RUNHOOD POWER


File Info : application/pdf, 21 Pages, 1.03MB

PDF preview unavailable. Download the PDF instead.

F3600-US-Users-Manual-RUNHOOD-POWER-2bb59-f3600-us-ex-1-8
RUNHOOD POWER INC.
F3600-US Product Manual
V1.0

Versions V1.0

Date 2024.1.22



Change Qinwei

Check

Approver

Change Content Alpha Version

1
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.

1 Definition Of Product .....................................................................................................................................3 1.1 Application scenarios.........................................................................................................................3 1.2 System block diagram .......................................................................................................................3 1.3 F3600 Residential ESS & Portable Power Station.....................................................................4 1.3.1 Product appearance ..............................................................................................................5 1.3.2 Principle block diagram........................................................................................................6 1.3.3 Specification parameters......................................................................................................6 1.3.4 Function description ..............................................................................................................8
2 Appendix.......................................................................................................................................................... 20
2
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.
1 Definition Of Product
1.1 Application scenarios
Application scenario 1: Used as an outdoor mobile energy storage power source. Supports input methods such as AC charging, photovoltaic charging, and vehicle charging. Supports DC output such as USB, DC12V, DC24V, and AC output. Can be moved and stacked for use. Application scenario 2: As a backup application for UPS households. Home power grid connected to RUNHOOD system application: It serves as a UPS for the home power grid, with two sets of hosts and battery packs. Application scenario 3: Home energy storage grid connected application. The RUNHOOD battery in the home photovoltaic energy storage system can replace (or be newly installed) the battery part of the energy storage system:
1.2 System block diagram
3
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.
1.3 F3600 Residential ESS & Portable Power Station
Composed of battery pack, inverter, DC interface, parallel interface, etc.
4
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.
1.3.1 Product appearance
Note: The type of AC socket varies in each country and region, and the actual product shall prevail.
5
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.
1.3.2 Principle block diagram

1.3.3 Specification parameters

Battery
LCD Screen Lamp
Wifi/Bluetooth Key

Cell Burst mode Quantity electricity Current range Voltage range Temperature range
Cycles LCD LED
Key1 Key2

F3600 LiFePO43214015Ah 5P15S 3600Wh48V75Ah
55A Max140A Max 38-53V
2~50-28~50 6000 cycles to 80%+ capacity SupportTouch Screen
Support
Support Main Power switch on/off
AC out on/off

6
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

DC
AC
EV INPUT BACK -UP OUTPUT Extra Battery Port*2 External communication Grounding
point Dip switch
Weight Dimensions
(LxWxD)
Certification

RUNHOOD POWER INC.

Key3 Key4 Input Ports
Output Ports
Input Ports
Output Ports AC AC

DC out on/off USB-A/C out on/off 12­150V 25A Max, 2400W Max, Car Charger, 12/24V 8.5A Max USB-A 12W Max * 2 USB-B 28W Max * 2 USB-C 100W Max * 2 Anderson 12/24V 30A Max Car Charger 12V 10A F3600-US 110V~120Vac60Hz15A Max, 1800W Max F3600-JP 100Vac50/60Hz15A Max, 1500W Max
F3600-EUF3600-UKF3600-AU 230Vac50Hz10A Max, 2300W Max
F3600-US 120VAC, 60Hz, 3600W (7200W Surge) 20A Max * 4, 30A Max * 1
3400W Max
3600W Max

Power and Communications
RJ45 *3 Com1: Debug port Com2: Debug port
Com3: Reserve
Earthing mark
Address coding & terminal resistance 48kg
58.8cm*40cm*42.4cm
Europe IEC62619IEC62477CEREDIEC60730 North America UL2743UL1973UL9540UL9540AFCC ID

7
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.
1.3.4 Function description
1. LCD display screen Display product's battery level and usage status prompts.
8
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.
9
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.
10
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.

Icon

Information

Prompt explanation

current address The current ID of the host or battery

product

No. of system The system supports expansion, and

connections

this icon indicates the number of

battery packs connected to the

system for expansion

No. of online work in the system
voltage frequency External PCS indication
Charging gun

After system expansion, parallel operation will be carried out based on the battery pack situation, and this icon indicates the current number of parallel operations Level voltage frequency
The system supports the use of external grid connected inverters. At this time, the product can be used as a home storage battery pack. This icon prompts when the system is connected to an external PCS When inserting the charging gun for charging, this icon prompts.

11
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.

High temperature alarm

The high temperature icon has a warning buzzer, indicating that the battery temperature is too high. When the high temperature icon is lit, the buzzer will intermittently sound for a short time, and the system will limit current charging; The buzzer sounds rapidly and briefly, and the system does not allow charging or discharging. Please place the product in a ventilated area, wait for the equipment to cool down and automatically reset. If the device does not reset, please contact our product expert service@runhoodpower.com .

Low temperature alarm

The low temperature icon comes with

a warning buzzer, indicating that the

battery temperature is too low. When

the low temperature icon is

displayed, the buzzer will

intermittently sound for a short time,

and the system will limit current

charging; The buzzer will sound

suddenly and briefly, and the system

will not allow charging or

discharging. The product will

automatically reset after reaching the

working temperature. If the device

does not reset, please contact our

product

expert

service@runhoodpower.com .

Important faults

When this icon prompts, it indicates a

serious malfunction. Check for strong

static or magnetic interference, and

then restart the device. If the device

fails to work again, please contact our

product

experts

service@runhoodpower.com .

fan status

When the host temperature overheats, the system will turn on the

12
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.

fan and light up the fan icon. If a fan icon appears but the fan is not working, please check if the fan is blocked. Before reusing, please turn off the device and carefully clean and vacuum all ventilation openings around it. If the device cannot operate, please contact our product experts service@runhoodpower.com

Home storage mode status

When the host is connected to the home energy storage backup mode, the system will light up the icon. If the icon does not appear after connection, please check if the connection line is connected correctly. If unable to resolve, please contact our product experts service@runhoodpower.com

HUB status

mode

When the host is connected to HUB, the system will light up the icon. If the icon does not appear after connection, please check if the connection line is connected correctly. If unable to resolve, please contact our product experts service@runhoodpower.com

2. AC output switch (hold down to turn on or off) AC output indicator light The AC power button controls the AC power output of F3600. To enable AC power, click the AC power button. When the AC power supply of F3600 is enabled, the AC indicator light will light up. When Overload occurs or the battery level is 0%, the AC output and AC indicator lights will turn off. When the battery level returns to above 2%, the AC output can return to normal. 3. AC output socket
13
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.
Power devices such as laptops, televisions, mini refrigerators, vacuum cleaners, etc. through communication sockets. Supports the use of 3600W electrical appliances for power reduction (does not support all excess appliances, needs to be tested and confirmed to be usable to avoid affecting your work and life).
4. LED lights The use of LED lights adopts a flip type. Flip up and turn on the light. The light intensity can be adjusted through the touch screen. 5. Main power button Press and hold the power button to turn on or off B3600. Power on: short press for 1.5 seconds. Power off: long press for 3 seconds. Forced power off: long press for 10 seconds. When F3600 is turned on, the power indicator light shows a breathing state and the display screen lights up; After F3600 is idle for more than 2 minutes, the backlight of the F3600 screen will be turned off, but the host is still running; After F3600 is idle for more than 5 minutes, the F3600 host will automatically shut down. 6. DC charging input port Specification XT60EW-M, can be charged to the power supply through the dedicated connection cable of RUNHOOD's built-in car charging port, and can be charged to the power supply through a photovoltaic panel.
14
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.
Supports input of 12V/24V maximum 8.5A in car power supply (make sure to start the car when using it to avoid battery depletion and inability to start). Supports solar panel series parallel input, voltage range: 15-150Vdc, current: 25A Max, power: 2400W Max, supports MPPT.
7. DC output switch key (vehicle charging output port, 2 Anderson output ports) and DC output port indicator light
Press and hold the DC switch to turn on or off the F3600 DC power output, while lighting up the indicator light for the DC output. This button controls the DC output of the F3600 car charging port and two Anderson DC outputs.
When there is an overload alarm prompt on the DC side output, pressing this button can clear the alarm prompt.
8. Car charging output port The car charging port supports a maximum current output of 10A and can be used for general on-board appliances. 9. Anderson output port
Provide power to various high-power DC power devices, such as car mounted DC refrigerators. At the same time, it can also charge 12V lead-acid batteries for cars or 24V lead-acid batteries for trucks (must be operated under the guidance of professionals).
10. USB output switch (USB-A output port and USB-C output port) and USB output port indicator light
15
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.

Press and hold the USB switch to turn on or off the USB output of F3600,

while also lighting up the USB output indicator light. This button controls the

USB-A and USB-C outputs of F3600.

When there is an overload alarm prompt on the USB output, pressing this

button can clear the alarm prompt.

11. USB-A output port

Charge various devices, such as iPhone, tablet, GoPro, speakers, or any

other device that charges through the USB-A port.

12. Fast charging 100W USB-C output port

Output: USB-C can charge devices including MacBook Pro, Android

phones, and any other USB-C port.

13. Ventilation and heat dissipation holes

The heat dissipation hole can prevent F3600 from overheating.

14. Buzzer output

The system comes with a buzzer for reminders when turning on and off.

15. Parallel interface

The parallel interface is divided into an upper connection port (Port-1) and

a lower connection port (Port-2). The specific interface information is shown in

the table below.

Description of the upper port (Port-1) Pins

Serial

Content

Describe

1 P+

Power +

16
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

2 P-

RUNHOOD POWER INC.
Power -

Serial 1 2 3 4 5 6 7 8

Content CAN0_H CAN0_L M_TX M_RX GND M_DET SYN_ON GND

Describe CAN0_H CAN0_L Uplink sending signa Uplink receive signa Ground wire Uplink judgment signal System start signal Ground wire

Description of the Lower Port (Port-2) Pins

Serial 1 2

Content P+ P-

Describe Power + Power -

Serial

Content

Describe

1 CAN0_H

CAN0_H

2 CAN0_L

CAN0_L

3 S_RX

Downlink receive signa

4 S_TX

Downlink sending signa

5 S_DET

Downlink judgment signal

6 SYN_ON

System start signal

7 GND

Ground wire

8 GND

Ground wire

16. Communication Interface

17
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.

The RJ45 interface includes three interfaces: the communication port for the

extended inverter (COM1), the debugging port (COM2), and the wet dry port

(COM3). The specific information is shown in the table below. RJ45-1COM1 Debugging port pin description

Serial

Content

Describe

1 NC

/

2 NC

/

3 NC

/

4 CAN1_H

CAN1_H

5 CAN1_L

CAN1_L

6 NC

/

7 RS485_A

RS485 Signal

8 RS485_B

RS485 Signal

RJ45-2COM2 Debugging port pin description

Serial

Content

Describe

1 CAN0_H

CAN0_H

2 CAN0_L

CAN0_L

3 GND

Ground wire

4 RS485_B1

RS485_B1

5 RS485_A1

RS485_A1

6 ACT

Wake up

7 GND

Ground wire

8 RESET

Reset

RJ45-3COM3 Description of dry and wet port pins

Serial 1 2

Content NO1 COM1

Describe Output signals 1 Output signals 1(COM)

18
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.

3 NO2 4 COM2 5 DIN+ 6 DIN1 7 DIN+ 8 DIN2 17. DIP switch

Output signals 2 Output signals 2(COM) Iutput signals 1+ Iutput signals 1 Iutput signals 2+ Iutput signals 2

6-digit DIP switch, 1-4 is the address DIP switch, 5 is reserved, and 6 is the communication terminal resistor 120  access switch. The effective address of

the address dial switch is 1-8, and 9-15 is temporarily an invalid address.

When multiple battery packs are working in parallel, it is necessary to

encode the addresses of each main control module. The encoding method and

instructions are shown in the table below.

Schematic diagram of dial switch

coding site

1

2

3

ON OFF OFF

OFF ON OFF

ON ON OFF

OFF OFF ON

ON OFF ON

OFF ON

ON

ON

ON

ON

OFF OFF OFF

Add. 4

OFF

(1)

OFF

2

OFF

3

OFF

4

OFF

5

OFF

6

OFF

7

ON

8

19
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

2 Appendix

RUNHOOD POWER INC.

2.1 Disclaimer
The length of all external cables shall not exceed 3m.
2.2 FCC Caution
a§ 15.19 Labeling requirements. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. b§ 15.21 Changes or modification warning. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. c§ 15.105 Information to the user. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
20
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.

RUNHOOD POWER INC.
residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. *RF warning for Mobile device: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
21
The copyright of this document belongs to RUNHOOD POWER INC. violation of rights will be prosecuted.


Microsoft Word for Microsoft 365