Model No. Name Material Colour IP Rating Input Voltage Lamp Base Lamp Wattage Colour Temp Lumens CRI Wiring Dimmable Warranty
Ø40 18 15
Ø63

HV1105T

HV1115T

316 Stainless Steel Stainless Steel

Solid Copper Copper

Dimensions:
Ø18

2x Ø4.2
40 Ø68 Mounting Bracket

Product Specifications

HV1125T

HV1135T

HV1145T

Tivah

Aluminium

Aluminium

Aluminium

Black

White

Silver

IP65

240v AC

GU10

3w, 5w, 7w

TRI Colour - 3000k, 4000k, 5500k

240-560lm, 255-595lm, 270-630lm

> 80

Parallel

No (with globe supplied)

2 Years Replacement*

HV1185T
Aluminium Titanium

HV1195T
Solid Brass Antique Brass

Important Safety Issues:
· This product must be installed by a qualified electrician according to AS/NZS 3000. · Ensure all electrical mains are disconnected before any installation. · Do not exceed maximum wattage restrictions for globes:
240V GU10 = 35w / 12V MR16 = 20w · Modification of this product will void any warranty. · Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of
installation material that does not belong to the system. · When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage
required, if not within this allowance warranty will be voided. · Aluminium and 304SS fittings must not be installed within 2km of any salt water
environments. · When installing copper fittings, gloves must be worn to avoid any oils transferring to fitting. · All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea
staining from forming on fitting. (Warranty does not cover Tea Staining) · All o-rings and seals must be in place correctly to maintain warranty. · These instructions may be updated at any time due to product improvements, Please visit website for most current installation instructions.

Steps for Installation:
1. Make sure that the electrical circuit is free of voltage (master switch off ) 2. Loosen allen screws on side of base and seperate mounting bracket from fitting. 3. Install the backing plate securely using appropiate screws for application, Seal all holes in the backing plate including cable entry and screw holes.
Failure to do so will void warranty. 4. Connect the cable - use wire with earth; connect the earth first, then live and neutral wire 5. Affix the fiiting to the mounting bracket and tighten allen screws, making sure these are tight to avoid any water penetration. 6. Apply silicon seal around the whole base plate to avoid any water getting into electrical connections. 7. Colour temperature and wattage is preset to 3000k and 7w, to change remove cover from fitting by twisting anti clockwise and set aside. Remove globe
and select desired colour temperature and wattage by moving switches on side of globe and reinsert globe into lampholders. 8. Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration. 9. All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.

Steps for Changing Globe:
1. Remove the cover by twisting anti-clockwise and set aside, remove globe by also twisting anti-clockwise. 2. Re-insert the appropriate globe by inserting the 2 circular pins into the lampholder and twisting clockwise.
(Make sure not to exceed max wattage, see product label for correct info) 3. Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration.

Contact Details:
143 Beauchamp Road Matraville NSW 2036 Australia

Must be installed by a licensed electrician
Warranty Terms & Conditions*
Tel: 02 9381 8300 Fax: 02 9666 8881 Email: sales@havit.com.au Web: www.havit.com.au

Additional Information

Tivah Fixed Down 5w GU10 Installation Instructions

Model No. Name Material Colour IP Rating Input Voltage Lamp Base Lamp Wattage Colour Temp Lumens CRI Wiring Dimmable Warranty
Ø40 18 15
Ø63

HV1107GU10T

HV1117GU10T

316 Stainless Steel Stainless Steel

Solid Copper Copper

Dimensions:
Ø18

2x Ø4.2
40 Ø68 Mounting Bracket

Product Specifications

HV1127GU10T

HV1137GU10T

HV1147GU10T

Tivah

Aluminium

Aluminium

Aluminium

Black

White

Silver

IP65

240v AC

GU10

5w

TRI Colour - 3000k, 4000k, 5500k

270lm, 285lm, 300lm

> 80

Parallel

No (with globe supplied)

2 Years Replacement*

HV1187GU10T
Aluminium Titanium

HV1197GU10T
Solid Brass Antique Brass

Important Safety Issues:
· This product must be installed by a qualified electrician according to AS/NZS 3000. · Ensure all electrical mains are disconnected before any installation. · Do not exceed maximum wattage restrictions for globes:
240V GU10 = 35w / 12V MR16 = 20w · Modification of this product will void any warranty. · Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of
installation material that does not belong to the system. · When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage
required, if not within this allowance warranty will be voided. · Aluminium and 304SS fittings must not be installed within 2km of any salt water
environments. · When installing copper fittings, gloves must be worn to avoid any oils transferring to fitting. · All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea
staining from forming on fitting. (Warranty does not cover Tea Staining) · All o-rings and seals must be in place correctly to maintain warranty. · These instructions may be updated at any time due to product improvements, Please visit website for most current installation instructions.

Steps for Installation:
1. Make sure that the electrical circuit is free of voltage (master switch off ) 2. Loosen allen screws on side of base and seperate mounting bracket from fitting. 3. Install the backing plate securely using appropiate screws for application, Seal all holes in the backing plate including cable entry and screw holes.
Failure to do so will void warranty. 4. Connect the cable - use wire with earth; connect the earth first, then live and neutral wire 5. Affix the fiiting to the mounting bracket and tighten allen screws, making sure these are tight to avoid any water penetration. 6. Apply silicon seal around the whole base plate to avoid any water getting into electrical connections. 7. Colour temperature is preset to 3000k, to change remove cover from fitting by twisting anti clockwise and set aside. Remove globe and select desired
colour temperature by moving switch on side of globe and reinsert globe into lampholders. 8. Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration. 9. All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.

Steps for Changing Globe:
1. Remove the cover by twisting anti-clockwise and set aside, remove globe by also twisting anti-clockwise. 2. Re-insert the appropriate globe by inserting the 2 circular pins into the lampholder and twisting clockwise.
(Make sure not to exceed max wattage, see product label for correct info) 3. Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration.

Contact Details:
143 Beauchamp Road Matraville NSW 2036 Australia

Must be installed by a licensed electrician
Warranty Terms & Conditions*
Tel: 02 9381 8300 Fax: 02 9666 8881 Email: sales@havit.com.au Web: www.havit.com.au

Additional Information

Tivah Fixed Down 5w MR16 Installation Instructions

Model No. Name Material Colour IP Rating Input Voltage Lamp Base Lamp Wattage Colour Temp Lumens CRI Wiring Dimmable Warranty
Ø40 18 15
Ø63

HV1107MR16T

HV1117MR16T

316 Stainless Steel Stainless Steel

Solid Copper Copper

Dimensions:
Ø18

2x Ø4.2
40 Ø68 Mounting Bracket

Product Specifications

HV1127MR16T HV1137MR16T HV1147MR16T

Tivah

Aluminium

Aluminium

Aluminium

Black

White

Silver

IP65

12v DC

MR16

5w

TRI Colour - 3000k, 4000k, 5500k

270lm, 285lm, 300lm

> 80

Parallel

No (with globe supplied)

2 Years Replacement*

HV1187MR16T
Aluminium Titanium

HV1197MR16T
Solid Brass Antique Brass

Important Safety Issues:
· This product must be installed by a qualified electrician according to AS/NZS 3000. · Ensure all electrical mains are disconnected before any installation. · Do not exceed maximum wattage restrictions for globes:
240V GU10 = 35w / 12V MR16 = 20w · Modification of this product will void any warranty. · Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of
installation material that does not belong to the system. · When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage
required and cannot be installed more than 25m from LED Driver, if not within this allowance warranty will be voided. · Aluminium and 304SS fittings must not be installed within 2km of any salt water environments. · When installing copper fittings, gloves must be worn to avoid any oils transferring to fitting. · All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea staining from forming on fitting. (Warranty does not cover Tea Staining) · All o-rings and seals must be in place correctly to maintain warranty. · These instructions may be updated at any time due to product improvements, Please visit website for most current installation instructions.

Steps for Installation:
1. Make sure that the electrical circuit is free of voltage (master switch off ) 2. Loosen allen screws on side of base and seperate mounting bracket from fitting. 3. Install the backing plate securely using appropiate screws for application, Seal all holes in the backing plate including cable entry and screw holes.
Failure to do so will void warranty. 4. Connect the cable - Connect live and neutral wire to a suitable 12v DC LED Driver - (DO NOT CONNECT DIRECTLY TO 240V POWER) 5. Affix the fiiting to the mounting bracketand tighten allen screws, making sure these are tight to avoid any water penetration. 6. Apply silicon seal around the whole base plate to avoid any water getting into electrical connections. 7. Colour temperature is preset to 3000k, to change remove cover from fitting by twisting anti clockwise and set aside. Remove globe and select desired
colour temperature by moving switch on side of globe and reinsert globe into lampholders. 8. Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration. 9. All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.

Steps for Changing Globe:
1. Remove the cover by twisting anti-clockwise and set aside, remove globe by also twisting anti-clockwise. 2. Re-insert the appropriate globe by inserting the 2 circular pins into the lampholder and twisting clockwise.
(Make sure not to exceed max wattage, see product label for correct info) 3. Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration.