Instruction Manual for HAVIT Lighting models including: 9 in 1 Tivah Fixed Down, 9 in 1 Fixed Down, Tivah Fixed Down, Fixed Down, Tivah Light, Tivah, Light
316 Stainless Steel Fixed Down LED Wall Light TRI Colour Havit Lightin - The Lighting Outlet
File Info : application/pdf, 3 Pages, 402.18KB
DocumentDocument9in1 Tivah Fixed Down Installation Instructions Model No. Name Material Colour IP Rating Input Voltage Lamp Base Lamp Wattage Colour Temp Lumens CRI Wiring Dimmable Warranty Ø40 18 15 Ø63 HV1105T HV1115T 316 Stainless Steel Stainless Steel Solid Copper Copper Dimensions: Ø18 2x Ø4.2 40 Ø68 Mounting Bracket Product Specifications HV1125T HV1135T HV1145T Tivah Aluminium Aluminium Aluminium Black White Silver IP65 240v AC GU10 3w, 5w, 7w TRI Colour - 3000k, 4000k, 5500k 240-560lm, 255-595lm, 270-630lm > 80 Parallel No (with globe supplied) 2 Years Replacement* HV1185T Aluminium Titanium HV1195T Solid Brass Antique Brass Important Safety Issues: · This product must be installed by a qualified electrician according to AS/NZS 3000. · Ensure all electrical mains are disconnected before any installation. · Do not exceed maximum wattage restrictions for globes: 240V GU10 = 35w / 12V MR16 = 20w · Modification of this product will void any warranty. · Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system. · When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage required, if not within this allowance warranty will be voided. · Aluminium and 304SS fittings must not be installed within 2km of any salt water environments. · When installing copper fittings, gloves must be worn to avoid any oils transferring to fitting. · All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea staining from forming on fitting. (Warranty does not cover Tea Staining) · All o-rings and seals must be in place correctly to maintain warranty. · These instructions may be updated at any time due to product improvements, Please visit website for most current installation instructions. Steps for Installation: 1. Make sure that the electrical circuit is free of voltage (master switch off ) 2. Loosen allen screws on side of base and seperate mounting bracket from fitting. 3. Install the backing plate securely using appropiate screws for application, Seal all holes in the backing plate including cable entry and screw holes. Failure to do so will void warranty. 4. Connect the cable - use wire with earth; connect the earth first, then live and neutral wire 5. Affix the fiiting to the mounting bracket and tighten allen screws, making sure these are tight to avoid any water penetration. 6. Apply silicon seal around the whole base plate to avoid any water getting into electrical connections. 7. Colour temperature and wattage is preset to 3000k and 7w, to change remove cover from fitting by twisting anti clockwise and set aside. Remove globe and select desired colour temperature and wattage by moving switches on side of globe and reinsert globe into lampholders. 8. Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration. 9. All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit. Steps for Changing Globe: 1. Remove the cover by twisting anti-clockwise and set aside, remove globe by also twisting anti-clockwise. 2. Re-insert the appropriate globe by inserting the 2 circular pins into the lampholder and twisting clockwise. (Make sure not to exceed max wattage, see product label for correct info) 3. Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration. Contact Details: 143 Beauchamp Road Matraville NSW 2036 Australia Must be installed by a licensed electrician Warranty Terms & Conditions* Tel: 02 9381 8300 Fax: 02 9666 8881 Email: sales@havit.com.au Web: www.havit.com.au Additional Information Tivah Fixed Down 5w GU10 Installation Instructions Model No. Name Material Colour IP Rating Input Voltage Lamp Base Lamp Wattage Colour Temp Lumens CRI Wiring Dimmable Warranty Ø40 18 15 Ø63 HV1107GU10T HV1117GU10T 316 Stainless Steel Stainless Steel Solid Copper Copper Dimensions: Ø18 2x Ø4.2 40 Ø68 Mounting Bracket Product Specifications HV1127GU10T HV1137GU10T HV1147GU10T Tivah Aluminium Aluminium Aluminium Black White Silver IP65 240v AC GU10 5w TRI Colour - 3000k, 4000k, 5500k 270lm, 285lm, 300lm > 80 Parallel No (with globe supplied) 2 Years Replacement* HV1187GU10T Aluminium Titanium HV1197GU10T Solid Brass Antique Brass Important Safety Issues: · This product must be installed by a qualified electrician according to AS/NZS 3000. · Ensure all electrical mains are disconnected before any installation. · Do not exceed maximum wattage restrictions for globes: 240V GU10 = 35w / 12V MR16 = 20w · Modification of this product will void any warranty. · Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system. · When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage required, if not within this allowance warranty will be voided. · Aluminium and 304SS fittings must not be installed within 2km of any salt water environments. · When installing copper fittings, gloves must be worn to avoid any oils transferring to fitting. · All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea staining from forming on fitting. (Warranty does not cover Tea Staining) · All o-rings and seals must be in place correctly to maintain warranty. · These instructions may be updated at any time due to product improvements, Please visit website for most current installation instructions. Steps for Installation: 1. Make sure that the electrical circuit is free of voltage (master switch off ) 2. Loosen allen screws on side of base and seperate mounting bracket from fitting. 3. Install the backing plate securely using appropiate screws for application, Seal all holes in the backing plate including cable entry and screw holes. Failure to do so will void warranty. 4. Connect the cable - use wire with earth; connect the earth first, then live and neutral wire 5. Affix the fiiting to the mounting bracket and tighten allen screws, making sure these are tight to avoid any water penetration. 6. Apply silicon seal around the whole base plate to avoid any water getting into electrical connections. 7. Colour temperature is preset to 3000k, to change remove cover from fitting by twisting anti clockwise and set aside. Remove globe and select desired colour temperature by moving switch on side of globe and reinsert globe into lampholders. 8. Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration. 9. All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit. Steps for Changing Globe: 1. Remove the cover by twisting anti-clockwise and set aside, remove globe by also twisting anti-clockwise. 2. Re-insert the appropriate globe by inserting the 2 circular pins into the lampholder and twisting clockwise. (Make sure not to exceed max wattage, see product label for correct info) 3. Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration. Contact Details: 143 Beauchamp Road Matraville NSW 2036 Australia Must be installed by a licensed electrician Warranty Terms & Conditions* Tel: 02 9381 8300 Fax: 02 9666 8881 Email: sales@havit.com.au Web: www.havit.com.au Additional Information Tivah Fixed Down 5w MR16 Installation Instructions Model No. Name Material Colour IP Rating Input Voltage Lamp Base Lamp Wattage Colour Temp Lumens CRI Wiring Dimmable Warranty Ø40 18 15 Ø63 HV1107MR16T HV1117MR16T 316 Stainless Steel Stainless Steel Solid Copper Copper Dimensions: Ø18 2x Ø4.2 40 Ø68 Mounting Bracket Product Specifications HV1127MR16T HV1137MR16T HV1147MR16T Tivah Aluminium Aluminium Aluminium Black White Silver IP65 12v DC MR16 5w TRI Colour - 3000k, 4000k, 5500k 270lm, 285lm, 300lm > 80 Parallel No (with globe supplied) 2 Years Replacement* HV1187MR16T Aluminium Titanium HV1197MR16T Solid Brass Antique Brass Important Safety Issues: · This product must be installed by a qualified electrician according to AS/NZS 3000. · Ensure all electrical mains are disconnected before any installation. · Do not exceed maximum wattage restrictions for globes: 240V GU10 = 35w / 12V MR16 = 20w · Modification of this product will void any warranty. · Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system. · When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage required and cannot be installed more than 25m from LED Driver, if not within this allowance warranty will be voided. · Aluminium and 304SS fittings must not be installed within 2km of any salt water environments. · When installing copper fittings, gloves must be worn to avoid any oils transferring to fitting. · All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea staining from forming on fitting. (Warranty does not cover Tea Staining) · All o-rings and seals must be in place correctly to maintain warranty. · These instructions may be updated at any time due to product improvements, Please visit website for most current installation instructions. Steps for Installation: 1. Make sure that the electrical circuit is free of voltage (master switch off ) 2. Loosen allen screws on side of base and seperate mounting bracket from fitting. 3. Install the backing plate securely using appropiate screws for application, Seal all holes in the backing plate including cable entry and screw holes. Failure to do so will void warranty. 4. Connect the cable - Connect live and neutral wire to a suitable 12v DC LED Driver - (DO NOT CONNECT DIRECTLY TO 240V POWER) 5. Affix the fiiting to the mounting bracketand tighten allen screws, making sure these are tight to avoid any water penetration. 6. Apply silicon seal around the whole base plate to avoid any water getting into electrical connections. 7. Colour temperature is preset to 3000k, to change remove cover from fitting by twisting anti clockwise and set aside. Remove globe and select desired colour temperature by moving switch on side of globe and reinsert globe into lampholders. 8. Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration. 9. All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit. Steps for Changing Globe: 1. Remove the cover by twisting anti-clockwise and set aside, remove globe by also twisting anti-clockwise. 2. Re-insert the appropriate globe by inserting the 2 circular pins into the lampholder and twisting clockwise. (Make sure not to exceed max wattage, see product label for correct info) 3. Reattach cover by turning clockwise making sure the seals are still in place and caps are tight to avoid any water penetration. Contact Details: 143 Beauchamp Road Matraville NSW 2036 Australia Must be installed by a licensed electrician Warranty Terms & Conditions* Tel: 02 9381 8300 Fax: 02 9666 8881 Email: sales@havit.com.au Web: www.havit.com.au Additional Information