DocumentDocumentSpecifications Inlet Water Temperature 60°C Maximum: 60°C Tools You'll Need Installation Instructions & User Guide Please leave these instructions with the end user Dynamic Water Pressure Min: 0.2 bar Max: 5.0 bar Product Code: MI BF C (D1) Inlet Connections 2.0 3.0 1.0 4.0 0.2 5.0 Pressure BAR 2.0 3.0 1.0 4.0 0.2 5.0 Pressure BAR Maximum Static Pressure: 10.0 bar 3/4" BSP Installation 1 2 Secure the taps to the basin by using the washer and metal backnut below the basin. Adjustable Spanner Prior to Installation Long-Nosed Pliers Pipe Cutter Aerator Key Pack Contents All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated and receive regular maintenance in accordance with these instructions. x1 This product needs to be installed in accordance with, and meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and current by-laws. For full Installation Requirements & Notes (IRN) please visit wras.co.uk/directory. Isolation valves must be fitted to the inlet water supplies to ensure ease of future maintenance. Before installing this product the water supply must be thoroughly flushed in order to remove any swarf, solder etc. Full access must be made available for future maintenance/ servicing purposes. This product must not be modified in any way x2 as this will invalidate the guarantee. x2 If in doubt, contact a registered plumber, your Local Water Authority or the Secretary of the Institute of Plumbing, address as follows:- The Institute of Plumbing, 64 Station Lane, Hornchurch, Essex, RM12 6NB, Tel: 01708 472791 Spare Parts To replace any spare parts for your tap, why not scan the QR Code or visit www.bristan.com and search for your product. 3 Hot Feed the tap body through the tap holes, ensuring the gasket washer is in place. Operation Cold 4 Turn on water supply and check all joints and connections for leaks. Off Off On On Connect the hot and cold water supplies to the threaded tails. leRtHfhEtoe,MtcroEiognMlhdtBtho!EenR Maintenance - Clean/Replace Outlet General Cleaning 1 2 Bristan products are made from premium Check for damage. materials, with hand polishing and Soak using a suitable electroplated finishes. solution to de-scale. Your taps or shower should be regularly cleaned with warm water, a mild pH-neutral liquid soap, and polished with a soft cloth. IMPORTANT Isolate the water supply before starting! Any residues from soap, toothpaste, shampoos and shower gels can cause blemishes if not rinsed off straight after use. Household bleaches and cleaners contain harsh chemicals and may damage the surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges, steel wool or anything similar. Using aerator key (not included), unscrew gently to remove the outlet. Screw back into the tap body to replace the outlet. Some surfaces such as nickel and pewter may be affected by the dye found in some cloths, so it is also important to avoid hanging cloths on spouts. Love Your Chrome Troubleshooting Symptom Cause Partially closed isolation valve. Instantaneous water heater cycles on and off as flow rate or pressure is too low. No flow or low flow rate Head of water is below the minimum distance required. Hot or cold water being drawn off elsewhere causing pressure changes or instantaneous boiler temperature changes. Airlock or partial blockage in the supply pipework. Water dripping from taps This is normal for a short time after using the taps. If water continues to drip, possibly due to the ceramic disc valves Taps do not Closed isolation valve. turn on Mains water supply turned off. Remedy Open isolation valve. Increase water flow rate or pressure through system. Refer to specification for minimum distance required. Do not use other water outlets when using the taps. Flush through pipework to ensure removal of debris and any airlocks. This is caused by residual water tension, the build up of water in the tap body. Remove valves and clean, refer to 'Maintenance' section before starting any maintenance. Open isolation valve. Turn on mains water supply. Bristan offers an effective chrome-friendly cleaning kit for use with your taps and showers. Scan the QR Code or search for `CLEAN KIT01' on www.bristan.com. Notes Contact Us 2 Maintenance - Valve Cleaning 1 Unscrew lever and washer to remove handle. IMPORTANT Isolate the water supply before starting! Unscrew the valve using a long nosed plier. Check any seals and O-rings for damage. Replace valve if necessary. 3 4 Place valves in a suitable solution and 1 23 soak until fully de-scaled. Reverse the steps to replace the valves and handles. Bristan Group Ltd. UK: Bristan Group, B78 1SG. EU: Masco Europe S.à.r.l. 14 Rue Strachen 6933 Mensdorf Luxembourg Customer Service: +44330 026 6273 Web: www.bristan.com Email: enquire@bristan.com A Masco Company Our Guarantee At Bristan, we want to make things as easy as possible for our customers. That's why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind. To start your free guarantee simply scan the QR code and register your product. Alternatively visit www.bristan.com/register. For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice. For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees.