Instruction Manual for BRISTAN models including: MI BF C Mila Chrome Bath Filter Tap, MI BF C, Mila Chrome Bath Filter Tap, Filter Tap, Tap

Bristan Mila Chrome Bath Filler Tap MI BF C Fitting Instructions (PDF)

Bristan Mila Bath Filler Tap Chrome MI BF C on sale at the best price from HomeSupply UK

Bristan Mila Bath Filler Tap Instructions

Bristan Mila Bath Filler Tap | Fast UK Delivery

Fitting Instruction

Bristan MIla Bath Filler | MI BF C | Pillar Mounted | Chrome


File Info : application/pdf, 2 Pages, 2.21MB

PDF preview unavailable. Download the PDF instead.

file-55883
Specifications
Inlet Water Temperature
60°C
Maximum: 60°C
Tools You'll Need

Installation Instructions & User Guide
Please leave these instructions with the end user

Dynamic Water Pressure Min: 0.2 bar Max: 5.0 bar

Product Code: MI BF C (D1) Inlet Connections

2.0 3.0

1.0

4.0

0.2

5.0

Pressure BAR

2.0 3.0

1.0

4.0

0.2

5.0

Pressure BAR

Maximum Static Pressure: 10.0 bar

3/4" BSP

Installation
1

2
Secure the taps to the basin by using the washer and metal backnut below
the basin.

Adjustable Spanner
Prior to Installation

Long-Nosed Pliers

Pipe Cutter

Aerator Key

Pack Contents

All products manufactured and supplied by Bristan are safe

to use provided that they are installed, operated and receive

regular maintenance in accordance with these instructions.

x1

This product needs to be installed in accordance with, and meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and current by-laws. For full Installation Requirements & Notes (IRN) please visit wras.co.uk/directory.

Isolation valves must be fitted to the inlet water supplies to ensure ease of future maintenance.

Before installing this product the water supply must be thoroughly flushed in order to remove any swarf, solder etc. Full access must be made available for future maintenance/ servicing purposes.

This product must not be modified in any way

x2

as this will invalidate the guarantee. x2

If in doubt, contact a registered plumber, your Local Water Authority or the Secretary of the Institute of Plumbing, address as follows:-

The Institute of Plumbing, 64 Station Lane, Hornchurch, Essex, RM12 6NB, Tel: 01708 472791

Spare Parts
To replace any spare parts for your tap, why not scan the QR Code or visit www.bristan.com
and search for your product.

3
Hot

Feed the tap body through the tap holes, ensuring the gasket washer is in place.

Operation

Cold

4
Turn on water supply and check all joints and connections for leaks.

Off

Off

On

On

Connect the hot and cold water supplies to the threaded tails.

leRtHfhEtoe,MtcroEiognMlhdtBtho!EenR

Maintenance - Clean/Replace Outlet General Cleaning

1

2

Bristan products are made from premium Check for damage. materials, with hand polishing and Soak using a suitable electroplated finishes.

solution to de-scale.

Your taps or shower should be regularly

cleaned with warm water, a mild pH-neutral

liquid soap, and polished with a soft cloth.

IMPORTANT
Isolate the water supply
before starting!

Any residues from soap, toothpaste, shampoos and shower gels can cause blemishes if not rinsed off straight after use.
Household bleaches and cleaners contain harsh chemicals and may damage the surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges, steel wool or anything similar.

Using aerator key (not included), unscrew gently to remove the outlet.

Screw back into the tap body to replace the outlet.

Some surfaces such as nickel and pewter may be affected by the dye found in some cloths, so it is also important to avoid hanging cloths on spouts.

Love Your Chrome

Troubleshooting

Symptom

Cause

Partially closed isolation valve.

Instantaneous water heater cycles on and off as flow rate or pressure is too low.

No flow or low flow rate

Head of water is below the minimum distance required.
Hot or cold water being drawn off elsewhere causing pressure changes or instantaneous boiler temperature changes.

Airlock or partial blockage in the supply pipework.

Water dripping from taps

This is normal for a short time after using the taps.
If water continues to drip, possibly due to the ceramic disc valves

Taps do not Closed isolation valve. turn on Mains water supply turned off.

Remedy Open isolation valve. Increase water flow rate or pressure through system.
Refer to specification for minimum distance required.
Do not use other water outlets when using the taps.
Flush through pipework to ensure removal of debris and any airlocks. This is caused by residual water tension, the build up of water in the tap body. Remove valves and clean, refer to 'Maintenance' section before starting any maintenance. Open isolation valve. Turn on mains water supply.

Bristan offers an effective chrome-friendly cleaning kit for use with your taps and showers. Scan the QR Code
or search for `CLEAN KIT01' on www.bristan.com.

Notes

Contact Us

2 Maintenance - Valve Cleaning

1

Unscrew lever and washer to remove

handle.

IMPORTANT Isolate the water supply
before starting!
Unscrew the valve using a long nosed plier. Check any seals and O-rings
for damage. Replace valve if necessary.

3

4
Place valves in a suitable solution and

1 23

soak until fully de-scaled.

Reverse the steps to replace the

valves and handles.

Bristan Group Ltd.

UK: Bristan Group, B78 1SG. EU: Masco Europe S.à.r.l.
14 Rue Strachen 6933 Mensdorf Luxembourg

Customer Service: +44330 026 6273

Web:

www.bristan.com

Email:

enquire@bristan.com

A Masco Company

Our Guarantee
At Bristan, we want to make things as easy as possible for our customers. That's why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind. To start your free guarantee simply scan the QR code and register your product. Alternatively visit www.bristan.com/register. For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice. For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees.



References