User Manual for Xhouse models including: Automatic Sliding Gate Opener, Sliding Gate Opener, Gate Opener, Opener
1. Summary This equipment is one of the auto gate openers launched by our company adopting a new design and integrated control system. Our new sliding gate opener has many features such as: low noise, light weight, powerful starting torque, stability, reliability and is compact and stylish. The motor will still work for a short period of time using lower voltage. The control board has overload ...
File Info : application/pdf, 25 Pages, 1.87MB
DocumentDocumentAutomatic Sliding Gate Opener User's Manual Attention The manual should be read cover to cover once prior to beginning installation Contents 1. Summary ················································································1 2. Appearance and Dimensions·····················································1 3. Parameters··············································································1 4. Installation of Mechanical Parts ·················································2 4.1 Installation of Motor Base Plate ··················································2 4.2 Installation of Gate Opener ························································2 4.3 Installation of Racks ·································································2 4.4 Installation of Limit Levers ·························································3 4.5 Function of Clutch ····································································3 5. Features Overview ···································································3 6. Control Board ·········································································4 6.1 Technical Parameters ·······························································4 6.2 Connection of The Power Supply ················································5 6.3 Terminal and Buttons Instruction ·················································7 7. How to Program or Erase The Remote ······································10 8. How to Operate The Gate Opener ·············································10 9. Control Board Function Description ·········································11 10.Control Board Digital Display Setting ······································14 11.Control Board Digital Display Information Show························16 12.Smart Module Instruction························································17 Add the device············································································17 Device supports WiFi and Bluetooth working mode·····························18 Switch WiFi network or Bluetooth mode············································19 Share the device··········································································20 Device settings············································································20 Remote assistance·······································································21 Add USB card / RF remote control from a distance·····························21 Add USB card/RF remote from the close range··································22 Management of the USB card and RF remote control··························22 Binding with camera·····································································23 1. Summary This equipment is one of the auto gate openers launched by our company adopting a new design and integrated control system. Our new sliding gate opener has many features such as: low noise, light weight, powerful starting torque, stability, reliability and is compact and stylish. The motor will still work for a short period of time using lower voltage. The control board has overload protection. When there is a power failure, the motor drive can be separated by the use of the clutch, by using the specified key the user has the ability to disconnect the clutch enabling the gate to be opened or closed manually. Using the optional infrared photocells the gate will automatically stop and re-open if an obstacle is sensed. 2. Appearance and Dimensions 133mm 250mm 86mm 275mm 248mm 31mm 3.Parameters 130mm Diagram 1 1. Working Temperature of Motor: -25°C~+55°C 2. Power Supply: 220VAC±10%/110VAC±10% 50Hz/60Hz 3. Working Humidity: 85% 4. Motor Voltage: 24VDC 10. Maximum Pull: 650N 5. Rated Power: 130W 11. Maximum Load: 500kg 6. Output Gear Module: M=4 12. Net Weight: 10kg 7. Output Gear Number: Z=16 13. Remote Control Distance: 50meter 8. Open(Close) Speed: V=26cm/s 14. Packing: In a Standard Carton 9. Rated Speed: 1400RPM 15. Protection Class: B 1 4. Installation of Mechanical Parts 4.1 Installation of Motor Base Plate 1. Depending on the installation size of the motor and mounting height of racks, after determine the installation position of the motor base plate, first let the bolt embedded or use expansion bolt to make base plate fixed on watering good cement foundation. See diagram 2 188mm 100mm Hole for fixing motor Diagram 2 2. If the rack has been installed on the door, the motor can be fixed on the base plate. use a Allen key rotation to the clutch "off" position, the motor and the gear rack so as to better determine the position of the motor base plate, then remove the motor and fixed base plate. 4.2 Installation of Gate Opener 1. Let the sliding gate opener put on the base plate.use a random matching hexagon screw make the motor fixed on the base plate. 2. Unscrew the screws fixed the motors cover, and then remove the motor cover according to the electrical wiring diagram, connected the power cord,after adjust in good position,Then install cover and use screws to fixed it. 4.3 Installation of Racks 1. After the motor is installed, the racks teeth the down, then put the gear on the motors. And final connected with screws and gate.push the door with hand. So can let door sliding it and can move it without any problem.after confirmed,fixed the racks. 2. Rack is usually unit assembly, in order to avoid gate run jitter or jammed, rack and joint clearance must be corrected. Suggest use this way,see diagram. 3. With a small correction of the rack, after connecting right with racks 1 and racks 2, then fixed racks 1 and 2. Rack 1 Correction of the rack Diagram 3 2 Rack 2 4.4 Installation of Limit Levers. There are 2 limit levers supplied. Note there is a left hand and a right hand lever. The levers should be installed one at either end of the rack. See Diagram 4. To install the levers in the correct position, open the clutch door and press the "CLOSE" button on the remote, the motor will run but will not drive the gate. Close the gate manually and adjust the limit lever to contact the toggle switch and switch the motor off at the desired gate position. To adjust the stop position of the gate when it is open, press the `OPEN' button, manually open the gate and adjust the other limit lever to contact the toggle switch and switch the motor off. When you are satisfied the levers are in the correct positions, tighten the screws in the levers to clamp them to the rack, close the clutch door and using the remote control check the gate opens and closes to the desired positions. Adjust the limit levers if necessary. Diagram 4 4.5 Function of Clutch. When the clutch is opened to the open position, you can manually push the door; when closing the clutch, electric door can run on, off, when touching limiting the bezel will stop automatically. Insert key, rotate 90 degrees CW Releasing arm in torsion, wriggle 90 degrees, gate operator will be 5. Features Overview in releasing state 1. Power Supply: AC 24V; available for connecting external 24V battery and battery charging, 24V output for external power supply. 2. Application Range: applied for DC motor of sliding door. 3. Transmitter Encoder: Custom rolling code, maximum capacity of 128PCS transmitter. 4. Motor: 24V DC Motor 3 5. Features: the limit function; resistance function, resistance sensitivity adjustable, fast and slow 2 speed running; fast running speed adjustable; motor automatically protected time 90s; auto-closing function can be set on/off optionally; automatic closing time adjustable; control panel single button control; available for connecting photocell, once the obstacle sensed by photocell while the door is closing, the door will stop and bounce back to open state; opening the door by swiping card. 6. Matching remote: RC-SM12G,RC SM01G,RC-SM27G 6.Control Board 2 1 14 13 12 11 10 9 8 7 6 5 43 16 17 18 19 6.1 Technical Parameters: 1.Board power supplyDC 24-28V or AC 19.6-24V 2.Battery power supply: DC 24V 3.Remote control: Giant customized rolling code 4.Remote control memory: max support 128pcs. 4 6.2 Connection of The Power Supply: WARNING: NEVER connect the gate opener to the power outlet before all the installations have been done. 1.If batteries are chosen as the power source, the batteries should be waterproof type, or be placed in waterproof circumstances. 2. 2PCS 12VDC batteries can be connected in series to function as 24VDC. The following diagram shows how to connect 2 PCS batteries in series. 3.Please note that the wire connection of the power supply system is very important. An incorrect wire connection will damage the control board. Note! If you also purchase the back up batteries from the manufacturer, before you using them to provide power to the gate opener system, please fully charge the batteries first. Power Mode 1. By AC electricity and transformer, only use AC transformer to supply the power. 5 Power Mode 2. Only use the batteries as the power source, use the solar panel and power charger receiver to charge the batteries. Before you using the back up batteries to provide power to the gate opener system, please fully charge the batteries first. Power Mode 3. By AC electricity and back-up batteries, only use the AC transformer to charge the batteries. If AC electricity failure happens rarely (less than 8 hours per day), then you can use a minimum of 2*12V DC batteries as a back-up power source in case of AC power failure. 6 6.3 Terminal and Buttons Instruction 1.POWER: used for connecting with DC 24-28V or AC 19.6-24V. 2.BATTERY: use for connecting with the DC 24V battery. 3&4. Motor: used for connecting with DC 24V sliding gate motor. 5.COM: used for connecting with COM terminal or GND. 6.VCC: 24V output is for connecting to an external device. (such as photocell sensor). 7.Lamp +/-: used for connecting with flashing light, output voltage is DC 24V. 8.PH: used for connecting with the photocell sensor. 9.Loop: used for connecting with loop detector etc device. 10.Start: It is a single button control mode switch for controlling the gate by "open - stop - close - stop - open" cyclically. 11.COM: used for connecting with the "ground" of external devices. 12.Close: used for connecting with any external devices that will operate to close the gate. 13.Open: used for connecting with any external devices that will operate to open the gate. 14.ANT: antenna connection. Note:Terminals 5 and 6 are supplying power for external devices. Buttons Function description 15.Digital display: used for showing you the setting data. 16.DEC/SMART: used for figure decreasing of setting the data or operate the smart module. 17.FUN: Used for enter the menu setting and confirm the data. 18.INC/START: used for figure increasing of setting the data or operate the single button control mode. 19.LEARN: used for programming/erasing the remote control. Connect terminal and with the motor. Please note : Our factory setting is install motor on the right-hand of gate! When you want to install motor on the left-hand of gate, please enter the digital display menu to set the parameter J2 value from 0 to 1 and set F1 value from 0 to 1. 7 ANT OPEN CLOSE COM START LOOP PH LAMP VCC COM Flash lamp wire diagram +- 14 13 12 11 10 9 8 7 6 5 ANT OPEN CLOSE COM START LOOP PH LAMP VCC COM Connect terminal lamp +/-. with the flash lamp. Safety beam wire diagram +- 14 13 12 11 10 9 8 7 6 5 Jumper NO OUT COM TX RX Photocell sensor use for gate meeting resistance: Connect terminal with the "COM " of photocell RX. Connect terminal with the "OUT " of photocell RX. Connect terminal with the "+ " of photocell RX and TX. Connect terminal with the "- " of photocell RX and TX. 8 ANT OPEN CLOSE COM START LOOP PH LAMP VCC COM Connect with start terminal Start terminal is used for connecting with some external devices , such push button, wired keypad, receiver etc. Control gate by " open-stop-close-stop-open " mode. +- 14 13 12 11 10 9 8 7 6 5 Terminal and are for connecting with the push button. Note! If you connect the swipe card or wired keypad, etc devices, please also connect with Vcc and Com to get the power supply. Safety beam wire diagram ANT OPEN CLOSE COM START LOOP PH LAMP VCC COM +- 14 13 12 11 10 9 8 7 6 5 Green Yellow Range Adjustment Board Black Blue Red Loop detector wire information: Definition of the 5 core cable RED Input Voltage (+) GREEN Ground/Common (-) BLACK Relay's Common BLUE Relay's Normally Open YELLOW Range adjustment potentiometer (POT) Red wire: connect with terminal . Green wire: connect with terminal and range adjustment board. Black wire: connect with terminal . Blue wire: connect with terminal . Yellow wire: connect with range adjustment potentiometer. 9 7.How to Program or Erase The Remote Program the remote: Short press the learn button and then release, the LED indicator will light on. Now user needs to press the button on the remote control, with the buzzer short beep, which means the remote code learning is successful, and the digital LED will show the quantity of that remotes were learned. After the user presses the learn button, within 8 seconds, if the controller doesn't receive the signal from the remote, the controller's LED indicator will turn out and exit the code learning statute. Note: Due to the digital display only can show two words, if the controller already learned more than 99pcs remote, from the 100th remote, the digital display will show A to replace the ten and hundred digits. Such as the 100th remote will show A0, and the 101st remote will show A1. If the controller already learned more than 109pcs remote, from the 110th remote, the digital display will show b to replace the ten and hundred digits.Such as the 110th remote will show b0.And the 120th remote will show C0. Max capacity: 128pcs remote. If the digital LED shows "-" with a buzzer short beep 5 times, then means can not learn more remotes. Erase the remote: Press and hold the learning button for 5 seconds, while the user hears the buzzer with a long beep, release the button, and the digital display shows "00".Now all remotes can not control the gate. 8.How to Operate The Gate Opener Each remote has 4 buttons, can set them with different work mode independently through the digital display menu L1, L2, L3 and L4, 0: No function. 1: Open-Stop-Close... 2: Pedestrian mode. 3: Open only. 4: Close only. 5: Stop only. 6:Turn auto close off via remote 10 9. Control Board Function Description Item Power on Description After the control board powered on, the buzzer will sound, and the digital display will show model number and version,and the state indicator LED will lit up. Open / Close LED indicator While the gate opener work normally, opening the gate will turn on blue, close the gatewill turn on red. Auto travel learning The newly installed motor needs to operate the auto travel learning once before the high and low speeds can be normally allocated. After the auto travel learning completed, the gate motor will automatically allocated the high and slow speed. The high and slow speeds for opening and closing can be set through the digital display menu. 1. Before starting the auto travel learning, the gate must be fully closed. 2. Enter the menu, select Pr, set 5, and confirm to start the auto travel learning 3. The gate will automatically open and close to remember the travel time. 4. Setting Motor slow speed running time for opening and closing separately through the menu. The larger the value, the more slow speed running time. During the auto travel learning process, if any control occurs, such as RF control, Pedestrian terminal trigger, safety beam trigger, etc., the auto travel learning will be interrupted and the learning operation needs to be restarted. If the auto travel learning fails halfway, the buzzer will sound twice, and the learning will be long once if the learning is successful. Setting slow speed running time After completed the auto-travel learning, the gate opener will automatic set the slow speed running time for opening and closing from 0 - 5 levels. The bigger the value is, the more slow speed running time. 0 means No slow speed running time. Setting running speed The gate opener can set the high speed and slow speed for opening and closing from for opening and 0 - 5 levels. The bigger the value is, the higher speed running. If adjust the running closing speed, please operate the auto-travel learning again. Overcurrent The overcurrent function can achieve an anti-smashing car. While the gate is opening, it detects the overcurrent and stop. If the gate is closing and detects the overcurrent, the user can set different response modes through the digital display menu. 0: reverse back to the opened position. 1: reverse to open the gate for 1 second. 2: reverse to open the gate for 3 seconds. 3: stop. Setting overcurrent for opening and closing the gate through the digital display menu. Limit switch mode 1. When the gate is fully opened/closed, and trigger the limit switch, the motor will auto stop. 2. The control board support to work with NO and NC limit switch, and can set the limit switch mode of NO and NC mode through the digital display menu. 3. The control board can switch the limit direction through the digital display menu. When the digital display show "Lr" means the limit switch detect a bug (limit error). Please check whether the limiter is damaged or in poor contact, or whether the normally open and normally closed mode (menu F0) set by the system does not match the actual limit switch type. 11 Setting of Loop terminal Safety beam mode Auto-closing timer for fully opening The loop detector have 2 function for optional, set them by the digital display menu: Mode 0: When the gate is opened or opening, trigger the loop terminal, when the loop signal is gone, will auto close immediately. When the gate is on closing, trigger the loop terminal, the gate will rebound to open right now. And after the loop signal is gone, then the gate will auto close immediately. Mode 1: When the gate is opened or closing, triggered the loop terminal, the gate will rebound to open right now. After the gate is opened, will enter the auto close timer countdown, set the timer by the digital display menu. The safety beam mode can be be selected by menu, the default mode is 0, it is normal open mode. 1. While the gate is closing, if the Ph terminal is triggered, the gate will reverse back to open. 2. If set the auto-closing timer after fully opening, after the safety beam signal is gone, the gate will be auto-closed. 3. If the safety beam signal exists, the gate closing action will not be executed and the auto-closing timer after fully opening will always be reset. 1. The auto-closing function is only triggered after the gate is fully opened. 2. Auto-closing timer for fully opening can be set through the digital display menu. 3. When auto-closing timer start to countdown, the STATE LED will flash one time each second. 4. When the gate is fully opened and in the countdown for closing, if there is a button on the remote control is used to cancel the auto-closing command, the user can operate it to cancel the auto-closing timer. Note: Cancellation only cancels this time, and the gate can be auto-closing next time when it is fully opened. Flash Lamp Mode The digital display menu can set the lamp work mode. Mode 0: Flashing light and motor will operate and stop at the same time. Mode 1: Flashing light will turn off 30 seconds after the motor stop. NOTE: No matter you choose the mode 0 or mode 1, when the gate is on the auto-closing timer countdown statue, the lamp also will light on. Motor protection As soon as the motor runs continuously for more than the 120s, the motor willautomatically stop working to protect the motor. Setting of start terminal Setting of open terminal The start terminal can be setting with different function through the digital display menu. 0: Open-Stop-Close......(factory default) 1: Pedestrian Open-Stop-Close. 2: Open only. 3: Close only. 4: Stop only. The open terminal can be setting with different function through the digital display menu. 0: Open-Stop-Close... 1: Pedestrian Open-Stop-Close... 2: Open only.(factory default) 3: Close only. 4: Stop only. 12 Setting of close terminal Pedestrian mode Smart charging function Upgrade control board system by USB device Smart Module (optional) The close terminal can be setting with different function through the digital display menu. 0: Open-Stop-Close... 1: Pedestrian Open-Stop-Close.... 2: Open only. 3: Close only.(factory default) 4: Stop only. The remote button and Pedestrian terminal can trigger the Pedestrian mode, the gate will partially open then stop, not fully open. This mode is convenient for users walking in and out. The pedestrian mode work with " open-stop-close-stop..." The Pedestrian mode timer and auto-closing timer after Pedestrian mode can set through the digital display menu. When the battery voltage is lower than 26V±1, the control board will active the smartcharging function.When the battery voltage exceeds 28V±1, the charging circuit is automatically disconnected to prevent overcharging. Note: The main power supply needs to be connected properly beforethe battery can be charged. Before you upgrade the system, please confirm the U disk document is FAT32 or not.If not, please format the U disk as FAT32. Copy the upgrade file into the root directory of the U disk and name it EGB-19.bin Insertthe U disk into the upgrade module, and then connect the upgrade module to the USB port. Enter the menu, select PU, select 5 for the value, and start the upgrade after confirmation. 1. Program the 2.4G transmitter: short press DEC/SMART button once, the buzzer willshort a beep, and the LED indicator will light on, enter the programming mode. Transmit a signal from the 2.4G transmitter, if the LED flash twice and keep lightingon, means the programming operation is successfully. Otherwise, after 8s exit the programming mode. 2. 2.4G control mode: While the module receive the 2.4G signal, it will trigger to openthe gate once. 3. Add the Bluetooth device: Open the XHouse app, enter the add device page, select the Bluetooth device. Select the correct Bluetooth device, press the add button. (The Bluetooth device modename is XHOUSE_092BLE_XXXXXXXXXXXX is its serial number) 4. Bluetooth device control mode: The app page have 3 buttons include open, close, stop. 5. Initialize Bluetooth device:Hold press DEC/SMART button about 5s, the buzzer willsound short beep twice, release the button, the operation is successfully. 6. Reset Bluetooth device: Hold press DEC/SMART button about 10s, the buzzer will sound long beep, release the button, the module will clear all 2.4G transmitters andinitialize the Bluetooth device. 13 10. Control Board Digital Display Menu Setting Press and hold the [FUN] button for 3 seconds, and the digital display will indicate "A0", then release the button, now the menu can be set to [INC/START] and [DEC/SMART] for increasing and decreasing numbers or values. After adjusting the value, press the [FUN] button to store the data, and the buzzer will beep one time to show the store successfully. After the menu setting is finished, press the [LEARN] button to exit the menu setting and close the display. Item A0 A1 A2 A3 A8 Function description Opening overcurrent setting in high speed Closing overcurrent setting in high speed Opening overcurrent setting in slow speed Closing overcurrent setting in slow speed Overcurrent sensitivity Value Factory set 0~20 level 10 Explanation Opening overcurrent setting in high speed, the bigger the value is, the harder the motor to stop. Setting value from 0-20. Closing overcurrent setting in high speed, 0~20 level 10 the bigger the value is, the harder the motor to stop. Setting value from 0-20. Motor 2 opening overcurrent setting in slow 0~20 level 10 speed, the bigger the value18 is, the harder the motor to stop. Setting value from 0-20 Motor 2 closing overcurrent setting in slow 0~20 level 10 speed, the bigger the value is, the harder the motor to stop. Setting value from 0-20 The bigger the value is, the longer the 0~3 level 0 overcurrent sensing time is. Setting value from 0-3. A9 Overcurrent reaction 0~3 Setting overcurrent reaction of gate: 0: Reverse back to the end. 0 1: Reverse back 1 second and stop. 2: Reverse back 3 seconds and stop. 3: Stop. Used for setting the slow speed running time B0 Setting slow speed running time for opening 0-5 level 2 of the gate opening, gate will run in slow speed within this setting, then change to high speed with its rest travel. Setting from 0-5 seconds. Used for setting the slow speed running time B1 Setting slow speed running time for closing 0-5 level 2 of the gate closing, gate will run in slow speed within this setting, then change to high speed with its rest travel. Setting from 0-5. C0 Auto-closing timer for fully opening 0-99 seconds 0 Setting from 0-99 seconds, 0 means No auto-closing for fully opening. D0 Speed of high speed for opening 0-5 level 5 Setting speed of high speed for opening, setting from 0-5 D1 Speed of high speed for closing 0-5 level 5 Setting speed of high speed for closing, setting from 0-5 14 D2 Speed of slow speed for opening 0-5 level 2 D3 Speed of slow speed for closing 0-5 level 2 E0 Pedestrian mode 0-15 seconds 6 E1 Auto closing timer for pedestrian mode 0-99 seconds 0 F0 Limit switch mode 0-1 1 F1 Switch the limit direction 0-1 0 F2 Safety beam mode 0-1 1 F3 Flash Lamp Mode 0-1 0 F4 Setting of Loop terminal 0-1 0 F5 Auto closing timer of loop terminal 0-99 seconds 0 G0 Setting of start terminal 0-4 0 G2 Setting of open terminal 0-4 2 G5 Setting of close terminal 0-4 3 J2 Switch the motor operation direction 0-1 0 L1 Button A function (Remote control) 0-6 1 L2 Button B function (Remote control) 0-6 0 15 Setting speed of slow speed for opening, setting from 0-5 Setting speed of slow speed for closing, setting from 0-5 0 means No pedestrian mode. 0 means No auto-closing for pedestrian mode 0NC mode. 1NO mode. 0: Default direction. 1: Switch direction. 0NC mode. 1NO mode. 0: Flashing light and motor will operate and stop at the same time. 1: Flashing light will turn off 30 seconds after the motor stop. 0: When gate closing, triggering the terminal, gate will reverse back to open, when the loop signal is gone,will auto close immediately. When gate is opened, triggering the terminal, when the loop signal is gone,will auto close immediately. 1: Loop is only used to open the gate. Setting from 0-99 seconds, 0 means No auto-closing for loop terminal. 0: Open-Stop-Close... 1: Pedestrian mode open-stop-close... 2: Open only. 3: Close only. 4: Stop only. 0: Open-Stop-Close... 1: Pedestrian mode open-stop-close... 2: Open only. 3: Close only. 4: Stop only. 0: Open-Stop-Close... 1: Pedestrian mode open-stop-close... 2: Open only. 3: Close only. 4: Stop only. 0: Default direction. 1: Switch direction 0: No function. 1: Open-Stop-Close... 2: Pedestrian mode. 3: Open only. 4: Close only. 5: Stop only. 6: Cancel the auto-closing function once. 0: No function. 1: Open-Stop-Close... 2: Pedestrian mode. 3: Open only. 4: Close only. 5: Stop only. 6: Cancel the auto-closing function once L3 Button C function (Remote control) 0-6 L4 Button D function (Remote control) 0-6 Pr Trigger auto travelling learning 0-10 PU Upgrade the system by USB device 0-10 Po Factory reset 0-10 0: No function. 0 1: Open-Stop-Close. 2: Pedestrian mode. 3: Open only. 4: Close only. 5: Stop only. 6: Cancel the auto-closing function once. 0: No function. 0 1: Open-Stop-Close. 2: Pedestrian mode. 3: Open only. 4: Close only. 5: Stop only. 6: Cancel the auto-closing function once. Setting from 0-10. 0 Set 5 will trigger the auto travel learning. 0 means No auto travel learning. Setting from 0-10. 0 Set 5 will trigger to upgrade the system. 0 means No upgrade the system. Setting from 0-10. 0 Set 5 will trigger to reset operation. 0 means No reset. 11.Control Board Digital Display Menu Information Show 1. When the gate is start to open, the digital display will show 1S "OP" 2. When the gate is start to close, the digital display will show 1S "CL" 3. After the gate stop moving, the digital display will show 1S"--" 4. When the gate moves to the full open limit, the digital display will show 1S"LO" 5. When the gate moves to the full close limit, the digital display will show 1S"LC" 6. When the motor reaches max working time, the digital display will show 1S"EC" 7. After the motor trigger the overload protection, if the motor run with high speed and the digital display will show 1S"OH", otherwise, the digital display will show 1S"OL". 8. After the photocell is activated, the digital display will show 1S "PH" 9. After the loop is activated, the digital display will show 1S"LP" 10. When the PED mode is activated, the digital display will show 1S"Pd" 11. When the limit switch broken or has a bug, the digital display will show "Lr" 12. Cancel the auto-closing, the digital display will show "CC" 16 12. Smart module instruction Search "XHouse IOT" and download it from Google play or App Store GET IT ON FOR Android & IOS Or scan this QR code for download APP "XHouse IOT" and install it. Register the account for "XHouse IOT"and log in. Add the device Step 1. Power on the device, open the APP. Press the "" on the top right corner to add the device, then select the " Sliding Gate " which has a orange circle on the top right corner. (Fig 1 and 2) ®If there has a gray circle on the top right corner, that means the device already be added. The user need to press and hold the "Dec/Smart" button for about 5s on the control board, then repeat the step 1. ®If there has a message "Please enter distribution network mode and add devices", the user need to press and hold the "Dec/Smart" button for about 5s on the control board, then repeat the step 1. Step 2. Select the Wi-Fi, click the "Connect" and enter the password.(Fig 3) (If there hasn't Wi-Fi can be connected, the user also can select the " Bluetooth Add " and use the Bluetooth function to control the gate nearly. Please follow the step 4). Step 3. Add the device successfully. The user can modify the name of the device and button from the " "on the top right corner. (Fig 5) Step 4: Bluetooth Add: When using Bluetooth mode control, the mobile app must be close to the device within Bluetooth range to connect and control, and only one user's phone can be connected at a time. (Fig. 3 and 4). Fig 1 Fig 2 17 Fig 3 Fig 4 Fig 5 Device supports WIFI and bluetooth working mode ®When the device is connected to WiFi network successfully, it supports remote control and settings the device through the mobile phone APP.cFig 5 ®When the device is offline or the mobile phone has no network, if the user is nearly the device within 10 meters, and open the APP, it will automatically switch to the Bluetooth mode to control the device. (Fig 6) ®The device will establish a Bluetooth connection with the mobile phone to achieve close-range Bluetooth control (only one user's mobile phone can establish a Bluetooth connection at the same time). Fig 5 Fig 6 18 Switch a new WiFi network or switch the Bluetooth mode to WiFi mode If the user need to switch to use a new WiFi network or want to switch control mode from the Bluetooth mode to WiFi mode, please follow the steps. Step 1. Select the device, press the " "on the top right corner. Click the " Set/Modify WiFi ". (Fig 7) Step 2. Select the new WiFi and connect it. And click the "Refresh". (Fig 8) Auto travel learning Fig 7 Fig 8 The newly installed motor needs to operate the auto travel learning once before the high and low speeds can be normally allocated. After the auto travel learning completed, the gate motor will automatically allocated the high and slow speed. The high and slow speeds for opening and closing can be set through the "Setting". Step 1. Before starting the auto travel learning, the gate must be fully closed. Step 2. Open the APP, select the device. Press the " " on the top right corner, select the "Travel learning" and click the "ENTER" & "Learn" to operate it. Step 3. The gate will automatically open and close to remember the travel time. Fig 7-1 19 Fig 8-1 Share the device Step 1. Open the APP, select the device. Press the " " on the top right corner, then select to "Sharing device", will create a QR code. (Fig 9) Step 2. The new user download the APP and open it, Press the "Scan" on the top right corner to scan the QR code. (Fig 10) Fig 9 Fig 10 Device settings The user can set the parameters from the APP for the control board. Step 1. Select the device, press the " "on the top right corner. Click the " Setting ". (Fig 11) Step 2. Set the parameters on the APP. (Fig 12) Note: While the user want to set the parameters, the device must connect with the Wi-Fi. If not, the user need to use the Bluetooth function and put the phone app as close as the device to set the parameters. After done, please click the "Sync" button. Fig 11 20 Fig 12 Remote assistance When your equipment fails, the parameter settings need to be readjusted. At this time, you can directly initiate the "Remote Assistance" button and share the QR code or verification code with your installation service provider for the remote service. Fig 13 Fig 14 Add USB card / RF remote control from a distance When the user need to add a RF remote control or a USB card to open the gate, you can use the " Add Card / Remote Control " function to do it, and scan the QR code from the remote control or enter the ID number for the USB card. Don't need to open the control box to program them. Fig 15 Fig 16 21 Add USB card/RF remote from the close range When the user needs to add an RF remote control or USB proximity card to open the door, you can directly use the "Add proximity card/RF remote control" function, click the "Learn" button, and click " Start Learning ". Don't need to open the control box, and the control board will enter the code learning state, and then press the remote control button or power on the USB card to transmit a signal. Fig 17 Fig 18 Management of the USB card and RF remote control The card list can management your USB card and RF remote control. The user can sync all the cards and remotes to the card list for management, and delete it when they are no longer needed or lost. Fig 19 22 Binding with camera Step 1. Open the APP, select the device. Press the " " on the top right corner, then select to " Binding camera ". Step 2. Select the " IP camera ", and press the " OK " to confirm it. Fig 20 Fig 21 23