Instruction Manual for BANNER models including: R95C-4B4UI-MQ, R95C Modbus Hubs, R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus Hub, R95C, 8-Port 2-Channel Discrete and Analog In-Out Modbus Hub, 8-Port 2-Channel Discrete, 2-Channel Discrete, Discrete, 2-Channel Discrete and Analog In-Out Modbus Hub, Analog In-Out Modbus Hub, Analog Modbus Hub, In-Out Modbus Hub, Modbus Hub, Modbus, Hub
R95C-4B4UI-MQ | R95C Modbus Hubs
R95C-4B4UI-MQ BANNER ENGINEERING, Signal Converter, 8-Port, IO Modbus, Current, Voltage, Current, Voltage, 2 Channels, 30 VDC |
File Info : application/pdf, 25 Pages, 10.86MB
DocumentDocumentR95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Original Instructions p/n: 234539 Rev. A June 26, 2024 © Banner Engineering Corp. All rights reserved. Contents Chapter 1 Features Models ........................................................................................................................................................................................................... 3 Overview........................................................................................................................................................................................................ 3 Chapter 2 Configuration Instructions Discrete In/Out Configuration ........................................................................................................................................................................ 4 Analog In/Out Configuration .......................................................................................................................................................................... 4 Modbus Configuration ................................................................................................................................................................................... 4 Multi-Port Support: Ports 1-4 .................................................................................................................................................................11 Multi-Port Support: Ports 5-8 ................................................................................................................................................................ 15 Chapter 3 Mechanical Installation Wiring........................................................................................................................................................................................................... 16 Chapter 4 Status Indicators.................................................................................................. 17 Chapter 5 Specifications FCC Part 15 Class B for Unintentional Radiators........................................................................................................................................ 19 Industry Canada ICES-003(B)..................................................................................................................................................................... 20 Dimensions .................................................................................................................................................................................................. 20 Chapter 6 R95C Accessories................................................................................................ 21 Chapter 7 Banner Engineering Corp Limited Warranty..................................................... 24 R95C 8-Port 2-Channel Discrete And Analog In-Out Modbus® Hub Instruction Manual Chapter Contents Models.................................................................................................................................................................................................................. 3 Overview .............................................................................................................................................................................................................. 3 Chapter 1 Features · Compact Modbus® device converter with the ability to send 4 ports of discrete input and 4 ports of analog input data (voltage or current) · This Modbus converter can also output discrete values and analog outputs (voltage or current) through any of the respective sets of 4 ports · 2-Channel Discrete Features: Enabled Delay Modes: ON/OFF Delay, ON/OFF One-shot, ON/ OFF Retriggerable One-shot, ON/OFF Pulse-stretcher and Totalizer Measurement Metrics: Count, Counts Per Minute (CPM), and Duration Discrete input/output can be independently configured as NPN or PNP Discrete Mirroring: Discrete signals (In/Out) from the four discrete ports can be mirrored to any of the output channels of the four discrete ports · Analog In/Out Features: Analog Out Mirroring: The analog input from all four analog ports can be mirrored as an output to any of the four analog ports PFM Output: The analog input from all four analog ports can be mirrored as PFM outputs to any of the four discrete ports. · Rugged overmolded design meets IP65, IP67, and IP68 · Connects directly to a sensor or anywhere in-line for ease of use · R95C Modbus hubs are a quick, easy, and economical way to integrate non-Modbus devices into a Modbus system Models Model Number R95C-4B4UI-MQ Function Converter Converter Type 8-ports: 4B: 4 ports, bimodal discrete input/output 4UI: 4 ports, analog input/output Control Connectors Modbus® (8) Integral 4-pin M12 female quick-disconnect connectors (1) Integral 5-pin M12 male quick-disconnect connector Overview The R95C 8-Port 2-Channel Discrete and Analog In/Out Modbus® Hub provides a mix of both discrete input/output and analog input/output functionality distributed to two sets of 4-ports Ports 1 through 4 contain the discrete functionality, and Ports 5 through 8 contain the analog functionality. These two sets of ports can be monitored and configured using an Modbus registers. June 26, 2024 © Banner Engineering Corp. All rights reserved. page 3 R95C 8-Port 2-Channel Discrete And Analog In-Out Modbus® Hub Instruction Manual Chapter Contents Discrete In/Out Configuration ............................................................................................................................................................................... 4 Analog In/Out Configuration ................................................................................................................................................................................. 4 Modbus Configuration .......................................................................................................................................................................................... 4 Chapter 2 Configuration Instructions Discrete In/Out Configuration Ports 1 through 4 contain discrete functionality. The figure below details the logic flow for each of the four bimodal discrete in/ out ports, and the tables define the configuration for each pin of the four bimodal ports. Input State Delay Mode · Disabled (active/inactive) · On Off Delay · On/Off One-shot · On/Off Pulse Stretcher · Totalizer Logic Flow Discrete 1 & 2 Selection Input Measurement Statistics Input State Measurement Statistics · Count · CPM · Duration Discrete 1 and 2 Input · Input (active/inactive) state Ouput Mirroring Enable Enabled Mirroring Mirroring - Discrete 1 and 2 Output · Port/Channel selected state Disabled Data Output Discrete 1 and 2 Output · Output (active/inactive) selected state Analog In/Out Configuration Ports 5 through 8 contain analog functionality. Analog In When an analog input value is received in Ports 5 through 8, the numerical representational value is sent to Modbus registers. Analog Input Ranges: · Voltage = 0 mV to 11,000 mV · Current = 0 µA to 24,000 µA Analog Out Ports 5 through 8 also allow for the user to output an analog value by sending the numerical analog value to Modbus registers Analog Output Ranges: · Voltage = 0 mV to 10,000 mV · Current = 4000 µA to 20,000 µA Output Outside Valid Range (OOVR) If the analog output value sent from this converter is outside of the Analog Output Range value, then the actual analog output value will be set to one of the three selectable OOVR levels after a 2-second delay: · Low (default): 0 V or 3.5 mA · High: 10.5 V or 20.5 mA · Hold: Level retains previous value indefinitely Modbus Configuration Device Port States Modbus Register Address 40001 40002 Description I/O Range Active States 0..255 Analog Input Active States 0..15 Comments Default Port 4..Port 1 Pin 4[P#1] & Pin 2[P#2] Active - States Inactive = 0, Active = 1 - Continued on page 5 Access Notes RO 0b[P42|P41|P32|P31|P22| P21|P12|P11] RO 0b[0|0|0|0|P8|P7|P6|P5] June 26, 2024 © Banner Engineering Corp. All rights reserved. page 4 Configuration Instructions R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Modbus Register Address 40003 40004 40005 40006 Description I/O Range Measurement Value - Analog In Port 5 0..65535 Measurement Value - Analog In Port 6 0..65535 Measurement Value - Analog In Port 7 0..65535 Measurement Value - Analog In Port 8 0..65535 Continued from page 4 Comments Default Voltage = mV, Current = µA - Voltage = mV, Current = µA - Voltage = mV, Current = µA - Voltage = mV, Current = µA - Analog Port Configuration Modbus Register Address 40007 Description I/O Range Port 8-5 Analog-Out | Port 8-5 Analog-In 0..255 Comments Voltage = 0, Current = 1 Default 0b11111111 Discrete Output States Modbus Register Address Description 40008 Output States I/O Range Comments Default 0..255 Port 4..Port 1 Pin 4[P#1] & Pin 2[P#2] Output States 0b00000000 Analog Out Value Modbus Register Address 40009 40010 40011 40012 Description Port 5 - Analog Value Port 6 - Analog Value Port 7 - Analog Value Port 8 - Analog Value I/O Range Comments 0..20500 0..20500 0..20500 0..20500 Voltage = mV, Current = µA 0 Voltage = mV, Current = µA 0 Voltage = mV, Current = µA 0 Voltage = mV, Current = µA 0 Default Alias RO Registers Modbus Register Address Description I/O Range Comments 40501 Port 5 Analog In 0..65535 Voltage = mV, Current = µA - 40502 Port 6 Analog In 0..65535 Voltage = mV, Current = µA - 40503 Port 7 Analog In 0..65535 Voltage = mV, Current = µA - 40504 Port 8 Analog In 0..65535 Voltage = mV, Current = µA - 40505 Port 1 Pin 4 Active State 0..1 0 = Inactive, 1 = Active - 40506 Port 1 Pin 2 Active State 0..1 0 = Inactive, 1 = Active - 40507 Port 2 Pin 4 Active State 0..1 0 = Inactive, 1 = Active - 40508 Port 2 Pin 2 Active State 0..1 0 = Inactive, 1 = Active - Continued on page 6 Access RO - RO - RO - RO - Notes Access Notes RW 0b[P8O|P7O|P6O|P5O] [P8I| P7I|P6I|P5I] Access Notes RW 0b[P42|P41|P32|P31|P22| P21|P12|P11] Access Notes RW Max Voltage = 10000 mV, Max Current = 20000 µA RW Max Voltage = 10000 mV, Max Current = 20000 µA RW Max Voltage = 10000 mV, Max Current = 20000 µA RW Max Voltage = 10000 mV, Max Current = 20000 µA Default Access RO RO RO RO RO RO RO RO June 26, 2024 © Banner Engineering Corp. All rights reserved. page 5 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Modbus Register Address Description I/O Range Continued from page 5 Comments 40509 Port 3 Pin 4 Active State 0..1 0 = Inactive, 1 = Active - 40510 Port 3 Pin 2 Active State 0..1 0 = Inactive, 1 = Active - 40511 Port 4 Pin 4 Active State 0..1 0 = Inactive, 1 = Active - 40512 Port 4 Pin 2 Active State 0..1 0 = Inactive, 1 = Active - 40513 Port 1 Pin 4 Count H 0..65535 Port 1 Pin 4 Count Value Upper - 40514 Port 1 Pin 4 Count L 0..65535 Port 1 Pin 4 Count Value Lower - 40515 Port 2 Pin 4 Count H 0..65535 Port 1 Pin 4 Count Value Upper - 40516 Port 2 Pin 4 Count L 0..65535 Port 2 Pin 4 Count Value Lower - 40517 Port 3 Pin 4 Count H 0..65535 Port 1 Pin 4 Count Value Upper - 40518 Port 3 Pin 4 Count L 0..65535 Port 3 Pin 4 Count Value Lower - 40519 Port 4 Pin 4 Count H 0..65535 Port 1 Pin 4 Count Value Upper - 40520 Port 4 Pin 4 Count L 0..65535 Port 4 Pin 4 Count Value Lower - 40521 Port 1 Pin 2 Count H 0..65535 Port 1 Pin 4 Count Value Upper - 40522 Port 1 Pin 2 Count L 0..65535 Port 1 Pin 2 Count Value Lower - 40523 Port 2 Pin 2 Count H 0..65535 Port 1 Pin 4 Count Value Upper - 40524 Port 2 Pin 2 Count L 0..65535 Port 2 Pin 2 Count Value Lower - 40525 Port 3 Pin 2 Count H 0..65535 Port 1 Pin 4 Count Value Upper - 40526 Port 3 Pin 2 Count L 0..65535 Port 3 Pin 2 Count Value Lower - 40527 Port 4 Pin 2 Count H 0..65535 Port 1 Pin 4 Count Value Upper - 40528 Port 4 Pin 2 Count L 0..65535 Port 4 Pin 2 Count Value Lower - 40529 Alias Register Value 0..65535 User defined - 40530 Alias Register Value 0..65535 User defined - 40531 Alias Register Value 0..65535 User defined - 40532 Alias Register Value 0..65535 User defined - Default Configuration Instructions Access RO RO RO RO RO RO RO RO RO RO RO RO RO RO RO RO RO RO RO RO RO RO RO RO page 6 © Banner Engineering Corp. All rights reserved. June 26, 2024 Configuration Instructions R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Alias Read/Only Addresses Modbus Register Address 40701 40702 40703 40704 40705 40706 40707 40708 40709 40710 40711 40712 40713 40714 40715 40716 40717 40718 40719 40720 40721 40722 40723 40724 40725 40726 Description Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address I/O Range Comments 0..65535 Value shows up in 40501 0..65535 Value shows up in 40502 0..65535 Value shows up in 40503 0..65535 Value shows up in 40504 0..65535 Value shows up in 40505 0..65535 Value shows up in 40506 0..65535 Value shows up in 40507 0..65535 Value shows up in 40508 0..65535 Value shows up in 40509 0..65535 Value shows up in 40510 0..65535 Value shows up in 40511 0..65535 Value shows up in 40512 0..65535 Value shows up in 40513 0..65535 Value shows up in 40514 0..65535 Value shows up in 40515 0..65535 Value shows up in 40516 0..65535 Value shows up in 40517 0..65535 Value shows up in 40518 0..65535 Value shows up in 40519 0..65535 Value shows up in 40520 0..65535 Value shows up in 40521 0..65535 Value shows up in 40522 0..65535 Value shows up in 40523 0..65535 Value shows up in 40524 0..65535 Value shows up in 40525 0..65535 Value shows up in 40526 Continued on page 7 Register to Assign 45001 RW 46001 RW 47001 RW 48001 RW 41001 RW 41002 RW 42001 RW 42002 RW 43001 RW 43002 RW 44001 RW 44002 RW 41003 RW 41004 RW 42003 RW 42004 RW 43003 RW 43004 RW 44003 RW 44004 RW 41011 RW 41012 RW 42011 RW 42012 RW 43011 RW 43012 RW Access June 26, 2024 © Banner Engineering Corp. All rights reserved. page 7 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Modbus Register Address 40727 40728 40729 40730 40731 40732 Description Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address I/O Range Continued from page 7 Comments 0..65535 Value shows up in 40527 0..65535 Value shows up in 40528 0..65535 Value shows up in 40529 0..65535 Value shows up in 40530 0..65535 Value shows up in 40531 0..65535 Value shows up in 40532 Alias RW Registers Modbus Register Address 40801 40802 40803 40804 40805 40806 40807 40808 40809 40810 40811 40812 40813 40814 40815 40816 40817 40818 40819 40820 Description Port 1 Pin 4 Active State Port 1 Pin 2 Active State Port 2 Pin 4 Active State Port 2 Pin 2 Active State Port 3 Pin 4 Active State Port 3 Pin 2 Active State Port 4 Pin 4 Active State Port 4 Pin 2 Active State Port 5 Analog Out Port 6 Analog Out Port 7 Analog Out Port 8 Analog Out Alias RW Register Value Alias RW Register Value Alias RW Register Value Alias RW Register Value Alias RW Register Value Alias RW Register Value Alias RW Register Value Alias RW Register Value I/O Range Comments 0..1 0 = Inactive, 1 = Active 0..1 0 = Inactive, 1 = Active 0..1 0 = Inactive, 1 = Active 0..1 0 = Inactive, 1 = Active 0..1 0 = Inactive, 1 = Active 0..1 0 = Inactive, 1 = Active 0..1 0 = Inactive, 1 = Active 0..1 0..65535 0..65535 0..65535 0..65535 0..65535 0 = Inactive, 1 = Active Voltage = mV, Current = µA Voltage = mV, Current = µA Voltage = mV, Current = µA Voltage = mV, Current = µA User defined 0..65535 User defined 0..65535 User defined 0..65535 User defined 0..65535 User defined 0..65535 User defined 0..65535 User defined 0..65535 User defined Continued on page 9 Configuration Instructions Register to Assign 44011 RW 44012 RW 0 RW 0 RW 0 RW 0 RW Access Default - Access RW RW RW RW RW RW RW RW RW RW RW RW RW RW RW RW RW RW RW RW page 8 © Banner Engineering Corp. All rights reserved. June 26, 2024 Configuration Instructions R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Modbus Register Address 40821 40822 40823 40824 40825 40826 40827 40828 40829 40830 40831 40832 Description Alias RW Register Value Alias RW Register Value Alias RW Register Value Alias RW Register Value Alias RW Register Value Alias RW Register Value Alias RW Register Value Alias RW Register Value Alias RW Register Value Alias RW Register Value Alias RW Register Value Alias RW Register Value I/O Range Continued from page 8 Comments 0..65535 User defined 0..65535 User defined 0..65535 User defined 0..65535 User defined 0..65535 User defined 0..65535 User defined 0..65535 User defined 0..65535 User defined 0..65535 User defined 0..65535 User defined 0..65535 User defined 0..65535 User defined Alias Read/Write Addresses Modbus Register Address 40901 40902 40903 40904 40905 40906 40907 40908 40909 40910 40911 40912 Description Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address I/O Range Comments 0..65535 Value shows up in 40801 0..65535 Value shows up in 40802 0..65535 Value shows up in 40803 0..65535 Value shows up in 40804 0..65535 Value shows up in 40805 0..65535 Value shows up in 40806 0..65535 Value shows up in 40807 0..65535 Value shows up in 40808 0..65535 Value shows up in 40809 0..65535 Value shows up in 40810 0..65535 Value shows up in 40811 0..65535 Value shows up in 40812 Continued on page 10 Default - Access RW RW RW RW RW RW RW RW RW RW RW RW Register to Assign 41401 RW 41402 RW 42401 RW 42402 RW 43401 RW 43402 RW 44401 RW 44402 RW 45002 RW 46002 RW 47002 RW 48002 RW Access June 26, 2024 © Banner Engineering Corp. All rights reserved. page 9 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Configuration Instructions Modbus Register Address 40913 40914 40915 40916 40917 40918 40919 40920 40921 40922 40923 40924 40925 40926 40927 40928 40929 40930 40931 40932 Description Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address Alias Register Address I/O Range Continued from page 9 Comments 0..65535 Value shows up in 40813 0..65535 Value shows up in 40814 0..65535 Value shows up in 40815 0..65535 Value shows up in 40816 0..65535 Value shows up in 40817 0..65535 Value shows up in 40818 0..65535 Value shows up in 40819 0..65535 Value shows up in 40820 0..65535 Value shows up in 40821 0..65535 Value shows up in 40822 0..65535 Value shows up in 40823 0..65535 Value shows up in 40824 0..65535 Value shows up in 40825 0..65535 Value shows up in 40826 0..65535 Value shows up in 40827 0..65535 Value shows up in 40828 0..65535 Value shows up in 40829 0..65535 Value shows up in 40830 0..65535 Value shows up in 40831 0..65535 Value shows up in 40832 Register to Assign 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW 0 RW Access Modbus Configuration Modbus Register Address 40601 40602 40603 40604 Description I/O Range Comments Baud Rate 0 = 9.6k 1 = 19.2k 2 = 38.4k 0 = 9600 1 = 19200 2 = 38400 Parity 0 = None 1 = Odd 2 = Even 0 = None 1 = Odd 2 = Even Address 1-254 - Reserved (cannot be read or written) None Continued on page 11 Default Access 1 RW 0 RW 1 RW - - page 10 © Banner Engineering Corp. All rights reserved. June 26, 2024 Configuration Instructions R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Modbus Register Address 40605 Description Restore Factory Configuration Continued from page 10 I/O Range Comments 0 = No Operation, 1 = Restore - Device Information Modbus Register Address 40606-40615 40616-40631 40632 40633 40634 40635 40636 40637 40644-40659 40680 40681 40682 40683 40684 Description Banner Name Product Name Item H Item L Serial Number H Serial Number Serial Number Serial Number L User Define Tag Discovery All-Time Run Time H All-Time Run Time L Resettable Run Time H Resettable Run Time L I/O Range Comments Default 0..65535 0..65535 0..65535 0..65535 0..65535 0..65535 0..65535 0..65535 0..65535 0..1 - Banner Engineering - R95C-4B4UI-MQ 814993 split into 12 two 16-bit registers 28561 - - - - - - - - User writable space More Sensors. More Solutions. 0 = Disabled, 1 = Enabled - 0..65535 - - 0..65535 Run counter (0.25 hr) - 0..65535 - - 0..65535 Run counter (0.25 hr) - Multi-Port Support: Ports 1-4 Register Ranges for Ports 1-4 41001-41400 42001-42400 43001-43400 44001-44400 Register Ranges Port 1 Port 2 Port 3 Port 4 Measurement Reads Modbus Register Address 41001 41002 Description Port 1 Pin 4 Active State Port 1 Pin 2 Active State I/O Range Comments 0..1 0 = Inactive, 1 = Active - 0..1 0 = Inactive, 1 = Active - Default 41003 Pin 4 Count H 0..65535 Pin 4 Count Value Upper - Continued on page 12 Default - Access WO Access Notes RO (9 words/18 characters) RO (16 words/32 characters) RO Banner Item Number RO - RO RO Serial Number is split into RO four 16-bit registers RO RW (16 words/32 characters) RW Flash all LEDs to find hub RO Upper 16 of 32 bits RO Lower 16 of 32 bits RW Upper 16 of 32 bits RW Lower 16 of 32 bits Port Number Access Notes RO - RO - Upper 16 of 32 bits = Running RO count of the received input pulses June 26, 2024 © Banner Engineering Corp. All rights reserved. page 11 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Configuration Instructions Modbus Register Address Description 41004 Pin 4 Count L I/O Range Continued from page 11 Comments Default 0..65535 Pin 4 Count Value Lower - 41005 Pin 4 Duration H 0..65535 Pin 4 Duration Value Upper - 41006 41007 41008 41009 41010 41011 41012 41013 Pin 4 Duration L 0..65535 Pin 4 Duration Value Lower - Pin 4 Counts Per Minute H 0..65535 Pin 4 Counts Per Minute L 0..65535 Pin 4 Totalizer Count H Pin 4 Totalizer Count L 0..65535 0..65535 Pin 2 Count H 0..65535 Pin 2 Count L 0..65535 Pin 4 Counts Per Minute - Value Upper Pin 4 Counts Per Minute - Value Lower Pin 4 Totalizer Count Upper - Pin 4 Totalizer Count Lower - Pin 2 Count Value Upper - Pin 2 Count Value Lower - Pin 2 Duration H 0..65535 Pin 2 Duration Value Upper - 41014 41015 41016 41017 41018 Pin 2 Duration L 0..65535 Pin 2 Duration Value Lower - Pin 2 Counts Per Minute H 0..65535 Pin 2 Counts Per Minute L 0..65535 Pin 2 Totalizer Count H Pin 2 Totalizer Count L 0..65535 0..65535 Pin 2 Counts Per Minute - Value Upper Pin 2 Counts Per Minute - Value Lower Pin 2 Totalizer Count Upper - Pin 2 Totalizer Count Lower - Access Notes Lower 16 of 32 bits = Running RO count of the received input pulses Upper 16 of 32 bits = RO Duration of the last input pulse in µs with 50 µs granularity Lower 16 of 32 bits = RO Duration of the last input pulse in µs with 50 µs granularity Upper 16 of 32 bits = Running RO count of the number of pulses received averaged over one minute. Range 1 to 37,500 Lower 16 of 32 bits = Running RO count of the number of pulses received averaged over one minute. Range 1 to 37,500 RO Upper 16 of 32 bits = Totalizer count RO Lower 16 of 32 bits = Totalizer count Upper 16 of 32 bits = Running RO count of the received input pulses Lower 16 of 32 bits = Running RO count of the received input pulses Upper 16 of 32 bits = RO Duration of the last input pulse in µs with 50 µs granularity Lower 16 of 32 bits = RO Duration of the last input pulse in µs with 50 µs granularity Upper 16 of 32 bits = Running RO count of the number of pulses received averaged over one minute. Range 1 to 37,500 Lower 16 of 32 bits = Running RO count of the number of pulses received averaged over one minute. Range 1 to 37,500 RO Upper 16 of 32 bits = Totalizer count RO Lower 16 of 32 bits = Totalizer count Measurement Count Presets: these registers reset ALL measurements, not just the count values Modbus Register Address Description 41100 Pin 4 Count H 41101 Pin 4 Count L 41102 Pin 2 Count H I/O Range Comments Default 0..65535 0..65535 0..65535 Pin 4 Count Value Upper - Pin 4 Count Value Lower - Pin 2 Count Value Upper - Continued on page 13 Access Notes RW Upper 16 of 32 bits RW Lower 16 of 32 bits RW Upper 16 of 32 bits page 12 © Banner Engineering Corp. All rights reserved. June 26, 2024 Configuration Instructions R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Modbus Register Address Description 41103 Pin 2 Count L I/O Range Continued from page 12 Comments Default 0..65535 Pin 2 Count Value Lower - Access Notes RW Lower 16 of 32 bits Pin 4 Port Configuration (Black - Female, Discrete 1) Modbus Register Address 41200 41201 41202 41203 41204 41205 41206 41207 41208 41209 41210 41211 Description Pin 4 IO Selection Pin 4 Mode I/O Range Comments Default Access 0 = NPN input 1 = PNP input 0..5 2 = NPN output with pull up 3 = PNP output with pull down 3 RW 4 = NPN output push/pull 5 = PNP output push/pull 0 = Disabled 1 = On Off Delay 2 = On One-shot 3 = Off One-shot 0..8 4 = On Pulse-stretcher 0 RW 5 = Off Pulse-stretcher 6 = Totalizer 7 = Retriggerable On One-shot 8 = Retriggerable Off One-shot Pin 4 Delay Timer 1 Upper 0..65535 Pin 4 On Delay, One-shot, Pulsestretcher time, Totalizer Count 0 RW Pin 4 Delay Timer 1 Lower 0..65535 Pin 4 On Delay, One-shot, Pulsestretcher time, Totalizer Count 0 RW Pin 4 Delay Timer 2 Upper 0..65535 Pin 4 Off Delay or Totalizer time 0 RW Pin 4 Delay Timer 2 Lower 0..65535 Pin 4 Off Delay or Totalizer time 0 RW Pin 4 Mirroring Enable 0..1 Pin 4 Mirroring Port Selection 0..7 0 = Disabled, 1 = Enabled 0 = Port 1 1 = Port 2 2 = Port 3 3 = Port 4 4 = Port 5 5 = Port 6 6 = Port 7 7 = Port 8 0 RW 0 RW Pin 4 Mirroring Selection 0..1 0 = Channel 1, 1 = Channel 2 0 RW Pin 4 Mirroring Inversion 0..1 0 = Not inverted, 1 = Inverted 0 RW Pin 4 PFM Near Frequency (Hz) 100..600 - Pin 4 PFM Far Frequency (Hz) 100..600 - 100 RW 600 RW Notes - - Upper 16 of 32 Bits: Mode 1, 2, 3, 4, 5, 7, 8 = Milliseconds Mode 6 = Count Lower 16 of 32 Bits: Mode 1, 2, 3, 4, 5, 7, 8 = Milliseconds Mode 6 = Count Upper 16 of 32 Bits = Milliseconds Lower 16 of 32 Bits = Milliseconds - If Port 1-4, Discrete Mirroring If Port 5-8, PFM of Analog In If Port 1-4, Discrete Mirroring If Port 1-4, Discrete Mirroring If Port 5-8, PFM of Analog In If Port 5-8, PFM of Analog In June 26, 2024 © Banner Engineering Corp. All rights reserved. page 13 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Configuration Instructions Pin 2 Port Configuration (White - Female, Discrete 2) Modbus Register Address 41300 41301 41302 41303 41304 41305 41306 41307 41308 41309 41310 41311 Description Pin 2 IO Selection Pin 2 Mode I/O Range Comments 0 = NPN input 1 = PNP input 0..5 2 = NPN output with pull up 3 = PNP output with pull down 4 = NPN output push/pull 5 = PNP output push/pull 0 = Disabled 1 = On Off Delay 2 = On One-shot 3 = Off One-shot 0..6 4 = On Pulse-stretcher 5 = Off Pulse-stretcher 6 = Totalizer 7 = Retriggerable On One-shot 8 = Retriggerable Off One-shot Default Access 3 RW 0 RW Pin 2 Delay Timer 1 Upper 0..65535 Pin 2 On Delay, One-shot, Pulsestretcher time, or Totalizer Count 0 RW Pin 2 Delay Timer 1 Lower 0..65535 Pin 2 On Delay, One-shot, Pulsestretcher time, or Totalizer Count 0 RW Pin 2 Delay Timer 2 Upper 0..65535 Pin 2 Off Delay or Totalizer time 0 RW Pin 2 Delay Timer 2 Lower 0..65535 Pin 2 Off Delay or Totalizer time 0 RW Pin 2 Mirroring Enable 0..1 Pin 2 Mirroring Port Selection 0..7 0 = Disabled, 1 = Enabled 0 = Port 1 1 = Port 2 2 = Port 3 3 = Port 4 4 = Port 5 5 = Port 6 6 = Port 7 7 = Port 8 0 RW 0 RW Pin 2 Mirroring Selection 0..1 0 = Channel 1, 1 = Channel 2 0 RW Pin 2 Mirroring Inversion 0..1 0 = Not Inverted, 1 = Inverted 0 RW Pin 2 PFM Near Frequency (Hz) 100..600 - Pin 2 PFM Far Frequency (Hz) 100..600 - 100 RW 600 RW Notes - - Upper 16 of 32 Bits: Mode 1, 2, 3, 4, 5, 7, 8 = Milliseconds Mode 6 = Count Lower 16 of 32 Bits: Mode 1, 2, 3, 4, 5, 7, 8 = Milliseconds Mode 6 = Count Upper 16 of 32 Bits = Milliseconds Lower 16 of 32 Bits = Milliseconds - If Port 1-4, Discrete Mirroring If Port 5-8, PFM of Analog In If Port 1-4, Discrete Mirroring If Port 1-4, Discrete Mirroring If Port 5-8, PFM of Analog In If Port 5-8, PFM of Analog In Active Configurations Modbus Register Address Description I/O Range Comments 41401 Port 1 Pin 4 Active State 0..1 0 = Inactive, 1 = Active 0 41402 Port 1 Pin 2 Active State 0..1 0 = Inactive, 1 = Active 0 Default Access Notes If mirroring disabled & IO RW selection is output, Data Output set to inactive/active If mirroring disabled & IO RW selection is output, Data Output set to inactive/active page 14 © Banner Engineering Corp. All rights reserved. June 26, 2024 Configuration Instructions R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Multi-Port Support: Ports 5-8 Register Ranges for Ports 5-8 45001-45305 46001-46305 47001-47305 48001-48305 Register Ranges Port 5 Port 6 Port 7 Port 8 Measurement Reads Modbus Register Address Description I/O Range Comments 45001 Measurement Value - Analog In Port 5 0..65535 Voltage = mV, Current = µA - 45002 Port 5 - Analog Out 0..20500 Voltage = mV, Current = µA 0 Default Port Output Configuration (Black - Channel 1) Modbus Register Address Description I/O Range Comments 45200 Port 5 - Mirroring Output Enable 0..1 0 = Disabled, 1 = Enabled 0 45201 45202 Port 5 - Mirroring Input Port Selection 0..1 Port 5 - Output Outside of Valid 0..2 Range 0 = Port 5 1 = Port 6 2 = Port 7 0 3 = Port 8 0 = Hold, 1 = Low, 2 = High 1 Default Port Output Configuration (White - Channel 2) Modbus Register Address 45300 45301 45302 45303 45304 45305 Description Port 5 - Voltage Minimum LED setpoint value Port 5 - Voltage Maximum LED setpoint value Port 5 - Voltage Hysteresis Port 5 - Current Minimum LED setpoint value Port 5 - Current Maximum LED setpoint value Port 5 - Current Hysteresis I/O Range Comments Default 0..9999 Must be less than maximum. V = 0 mV 0..10000 Must be greater than minimum. V = 10000 mV 0..500 0..19999 0..20000 mV V = 50 mV Must be less than maximum. 4000 µA Must be greater than minimum. 20000 µA 0..500 µA 100 µA Port Number Access Notes RO - RW Voltage = 10000 mV, Current = 20000 µA Access Notes If Enabled, Analog Out value RW in register 40009 will be ignored RW - RW - Access Notes RW - RW If value > Max I/O Range, value = Max RW If value > Max I/O Range, value = Max RW - RW If value > Max I/O Range, value = Max RW If value > Max I/O Range, value = Max June 26, 2024 © Banner Engineering Corp. All rights reserved. page 15 R95C 8-Port 2-Channel Discrete And Analog In-Out Modbus® Hub Instruction Manual Chapter Contents Wiring ................................................................................................................................................................................................................. 16 Chapter 3 Mechanical Installation Install the R95C to allow access for functional checks, maintenance, and service or replacement. Do not install the R95C in such a way to allow for intentional defeat. Fasteners must be of sufficient strength to guard against breakage. The use of permanent fasteners or locking hardware is recommended to prevent the loosening or displacement of the device. The mounting hole (4.5 mm) in the R95C accepts M4 (#8) hardware. See the figure below to help in determining the minimum screw length. MOUNTING SCREW 17.0 mm CAUTION: Do not overtighten the R95C's mounting screw during installation. Overtightening can affect the performance of the R95C. Wiring Male Pin 1 1 2 2 4 3 3 5 4 5 Port 1-Port 4 -- Female Pin 1 2 1 2 4 3 3 4 Port 5-Port 8 -- Female Pin 1 2 1 2 4 3 3 4 12 V DC to 30 V DC RS485/D1/B/+ Ground RS485/D0/A/Banner 1-wire Signal Description 12 V DC to 30 V DC Discrete 2 (IN/OUT) Ground Discrete 1 (IN/OUT) Signal Description 12 V DC to 30 V DC Analog In Ground Analog Out Signal Description June 26, 2024 © Banner Engineering Corp. All rights reserved. page 16 R95C 8-Port 2-Channel Discrete And Analog In-Out Modbus® Hub Instruction Manual Chapter Contents Chapter 4 Status Indicators On both sides of the R95C Modbus hub, Ports 1 through 4 have two matching amber LED discrete output indicators, and Ports 5 through 8 have two matching amber LED analog in/analog out indicators. There is also an additional amber LED indicator on both sides of the converter, which is specific to the Modbus communication, and a green LED indicator that shows power status. Analog In/Out LEDs x8 (on either side) Com LED (on either side) 8 IN OUT 7 IN OUT 6 IN OUT 5C IN OUT Power LED (on either side) C5 OUT IN 6 OUT IN 7 OUT IN 8 OUT IN 12 4 12 3 12 2 12 1 Rotate 180° 21 1 21 2 21 3 21 4 Device LEDs x8 (on either side) LED 1 = Discrete 1 In/Out LED 2 = Discrete 2 In/Out LED Discrete Device Amber LEDs Analog In Amber LED(1) Indication Off Solid Amber Off Solid Amber Off Analog Out Amber LED Solid Amber Modbus Communication Amber LED Off Status Discrete In and Out are inactive Discrete In or Out is active Analog current value is less than setpoint one OR analog value is greater than setpoint two Analog current value is between setpoint one AND setpoint two Turns off if written PDO analog value is outside the allowable output range Allowable Voltage Range: 0 V to 10 V. Allowable Current Range: 4 mA to 20 mA. Turns on if written PDO analog value is inside the allowable output range Allowable Voltage Range: 0 V to 10 V. Allowable Current Range: 4 mA to 20 mA. Modbus communications are not present Continued on page 18 (1) Default Current Values: SP1 = 0.004 A, SP2 = 0.02 A. Default Voltage values: SP1 = 0 V, SP2 = 10 V. June 26, 2024 © Banner Engineering Corp. All rights reserved. page 17 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Status Indicators Continued from page 17 LED Indication Status Flashing Amber (4 Hz) Modbus communications are active Solid Amber for 2 Seconds, Then to Off Modbus communications are lost after connection Solid Amber for 2 Seconds, Then to Flashing Amber (4 Hz) Modbus communications momentarily lost, but then communication was reestablished Off Power Indicator Green LED Solid Green Power off Power on page 18 © Banner Engineering Corp. All rights reserved. June 26, 2024 R95C 8-Port 2-Channel Discrete And Analog In-Out Modbus® Hub Instruction Manual Chapter Contents FCC Part 15 Class B for Unintentional Radiators .............................................................................................................................................. 19 Industry Canada ICES-003(B)............................................................................................................................................................................ 20 Dimensions......................................................................................................................................................................................................... 20 Chapter 5 Specifications Supply Voltage 12 V DC to 30 V DC at 400 mA maximum (exclusive of load) Power Pass-Through Current Not to exceed 4 amps total Discrete Output Load Rating 200 mA Analog Input Impedance Current version: Approximately 250 Voltage version: Approximately 14.3k Analog Output Load Requirements Voltage version = Resistance > 1000 Current version = Resistance < 500 Supply Protection Circuitry Protected against reverse polarity and transient voltages Leakage Current Immunity 400 µA Indicators Green: Power Amber: Modbus communications Amber: 2x Discrete IN/OUT status Amber: Analog input value present Amber: Analog output value in range Connections (8) Integral 4-pin M12 female quick-disconnect connectors (1) Integral 5-pin M12 male quick-disconnect connector Construction Coupling Material: Nickel-plated brass Connector Body: PVC translucent black Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave) Environmental Rating IP65, IP67, IP68 UL Type 1 Operating Conditions Temperature: 40 °C to +70 °C (40 °F to +158 °F) 90% at +70 °C maximum relative humidity (non-condensing) Storage Temperature: 40 °C to +80 °C (40 °F to +176 °F) Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) 20 22 24 Required Overcurrent Protection (A) 5.0 3.0 1.0 Supply Wiring (AWG) 26 28 30 Required Overcurrent Protection (A) 1.0 0.8 0.5 Certifications Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM Turck Banner LTD Blenheim House Blenheim Court Wickford, Essex SS11 8YT GREAT BRITAIN Product Identification FCC Part 15 Class B for Unintentional Radiators (Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. June 26, 2024 © Banner Engineering Corp. All rights reserved. page 19 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Specifications · Consult the dealer or an experienced radio/TV technician for help. (Part 15.21) Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Industry Canada ICES-003(B) This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif. Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. page 20 © Banner Engineering Corp. All rights reserved. June 26, 2024 R95C 8-Port 2-Channel Discrete And Analog In-Out Modbus® Hub Instruction Manual Chapter Contents Chapter 6 R95C Accessories Cordsets Model BC-M12F4-M12M4A-22-1 BC-M12F4-M12M4A-22-2 BC-M12F4-M12M4A-22-5 BC-M12F4-M12M4A-22-8 BC-M12F4-M12M4A-22-10 BC-M12F4-M12M4A-22-15 4-pin M12 Cordsets - Female Straight to Male Right-Angle Double-Ended Length Dimensions (mm) Pinouts 1 m (3.28 ft) 2 m (6.56 ft) 5 m (16.4 ft) 8 m (26.25 ft) 10 m (30.81 ft) 15 m (49.2 ft) 32 Typ. [1.26"] 30 Typ. [1.18"] M12 x 1 ø 14.5 [0.57"] 44 Typ. [1.73"] ø 14.5 [0.57"] M12 x 1 Female 2 1 3 4 Male 1 2 4 3 1 = Brown 2 = White 3 = Blue 4 = Black Model BC-M12F4A-M12M4A-22-1 BC-M12F4A-M12M4A-22-2 BC-M12F4A-M12M4A-22-5 BC-M12F4A-M12M4A-22-8 BC-M12F4A-M12M4A-22-10 BC-M12F4A-M12M4A-22-15 4-pin M12 Cordsets - Female Right-Angle to Male Right-Angle Double-Ended Length Dimensions (mm) Pinouts 1 m (3.28 ft) 2 m (6.56 ft) 5 m (16.4 ft) 8 m (26.25 ft) 10 m (30.81 ft) 15 m (49.2 ft) 32 Typ. [1.26"] 30 Typ. [1.18"] Female 2 1 3 4 M12 x 1 ø 14.5 [0.57"] Male 31 Typ. 1 2 32 Typ. 4 3 1 = Brown 2 = White 3 = Blue 4 = Black Splitter Cordsets 4-Pin Threaded M12 Male to 5-Pin Threaded M12 Female Splitter Cordset Model Branches (Female) Wiring N/C S15YA4-M124-M124-0.2M L1, L2 2 × 0.2 m (7.9 in) N/C Continued on page 22 June 26, 2024 © Banner Engineering Corp. All rights reserved. page 21 R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Continued from page 21 4-Pin Threaded M12 Male to 5-Pin Threaded M12 Female Splitter Cordset Model Branches (Female) L2 M12 x 1 R95C Accessories Wiring M12 x 1 2X 2X L1 Model CSB4-M1251M1250 Branch 1 2 x 19 Branch 2 72 mm Branch 3 3 x 18 Branch 4 Model 5-Pin Threaded M12 Splitter Cordset with Flat Junction--Double Ended Description Pinout (Male) Four (no cable) 5-pin M12 female quickdisconnect connectors 1 2 One 0.3 m (0.98 ft) cable with a 5-pin M12 4 male quick-disconnect connector 3 5 Parallel wiring 32 mm Male Trunk Length 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray 4-Pin Threaded M12 RS-485 to USB Adapter Cordset, with Wall Plug Length Style Dimensions BWA-UCT-900 1 m (3.28 ft) Straight Splitter Tee Model 5-Pin Threaded M12 Splitter Tee Pinout (Male) CSB-M1250M1250-T · Two 5-pin M12 female quick-disconnect connectors · One 5-pin M12 male quick-disconnect connector · Parallel wiring 1 2 4 3 5 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray Pinout (Female) 2 1 3 4 5 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray Pinout (Female) 2 4 1 3 1 = Brown 2 = White 3 = Blue 4 = Black Pinout (Female) 2 1 3 4 5 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray page 22 © Banner Engineering Corp. All rights reserved. June 26, 2024 R95C Accessories 5-Pin Molded Junction Blocks Model R50-4M125-M125Q-P Molded Junction Block · Four integral 5-pin M12 female quickdisconnect connectors · One integral 5-pin M12 male quickdisconnect connector · Parallel wiring · Product documentation (p/n 227974) R95-8M125-M125Q-P Molded Junction Block · Eight integral 5-pin M12 female quickdisconnect connectors · One integral 5-pin M12 male quickdisconnect connector · Parallel wiring · Product documentation (p/n 227974) R95C 8-Port 2-Channel Discrete and Analog In-Out Modbus® Hub Instruction Manual Pinout (Male) Pinout (Female) 1 2 4 3 5 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray 2 1 3 4 5 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray Brackets SMBR90S · Stainless steel bracket · 4x M4-07 pemnuts (B) · Includes 2x M4 stainless steel hex head screws and flat washers Hole center spacing: A = 40, B = 20 Hole size: A = ø 5 SMBR95RA · Stainless steel right-angle bracket · M4 x 0.7 mm #316SS screws (qty 2) 8.6 B 74 A 24 10.1 90 2X M4 x 0.7 PEM Ø4.5 2X Ø4.5 40 40 June 26, 2024 © Banner Engineering Corp. All rights reserved. page 23 R95C 8-Port 2-Channel Discrete And Analog In-Out Modbus® Hub Instruction Manual Chapter Contents Chapter 7 Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. June 26, 2024 © Banner Engineering Corp. All rights reserved. page 24 LinkedIn Twitter Facebook © 2024. All rights reserved. www.bannerengineering.com