QUICK START GUIDE RER-11 RANGER® EDGE RECEIVER

This Quick Start Guide is intended for experienced installing technicians. It is a basic reference to ensure all connections are properly made. Installation and wiring of systems must be in accordance with the National Electrical Code, ANSI/NFPA 70.

1.0 Description Long-Range Transmitters and Receivers with an integrated receive antenna comprise Farpointe Data's high frequency, long-range identification solution known as Ranger. Intended for security access control applications, Ranger's wireless communications are based upon a secure, digital, anti-playback routine. The one-channel Ranger Edge Receiver, model RER-11 natively supports Ranger Long-Range Transmitters with its integrated receive antenna. Additionally, via the on-board Wiegand interface, the Edge Receiver may optionally support a variety of RFID reader and associated card and tag technologies, as well as access applications, including keypads (PIN) and biometrics. The RER-11 offers single location point of control with all configuration done directly on the Receiver, eliminating the requirement for separate mobile smartphone or PC programming devices.

4.0 Cable Requirements For connection to Wiegand interface, 24 AWG multi-conductor stranded cable with an overall foil shield. Per the SIA's Wiegand specification, maximum cable length is 500 feet (152 m).
5.0 Formats Wiegand is supported, including industry standard 26-bit Wiegand, as well as custom formats with a maximum length of 48-bits.
6.0 Grounding Edge Receiver must connect to earth ground at one point only. Additionally, if multiple power supplies are used, all ground conductors ("commons") should be connected together at one point and then earth grounded at one point only.

2.0 Receiver Layout9

Legend:

PROGRAM BUTTON XO BUTTON OX

A. 12-Position slide

A

H

ADDRESS

LB

12 11 10 9 8 7 6 5 4 3 2 1 1

style Dip Switches B. Credential

DOOR
C DPS
GND REX RLY/NO RLY/CMN RLY/NC GND +12V IN

RLY1

E

RUN R73

VNH40 J112G

Panasonic JS1-5V-F AJS1319F
10A125V~ Cosø=1.0

0 SW2
D SW1

F
R72

SELECT STATUS

1833-02464-0010 X161117-001
Rev 02

PROGRAM / RUN

RELAY

DPS

REX

GND TX RX 5V

P/N: X161117-001 REV2

enrollment/ deletion switches orientation C. 8-Position Door terminal block D. Switch 1 E. Relay F. LEDs

SERIAL I/O

SPULE: 5V 712210

G D1 D0 L

+12V B GND OUT

READER

G. 6-Position Wiegand interface terminal block

The dip switches are set to the 0-position by default.

3.0 12-Position Slide Style Dip Switches Designations

12 11 10 9 8 7 6 5 4 3 2 1

Dip Switch 12: Program/Run Switch

12 11 10 9 8 7 6 5 4 3 2 1

Dip Switches 10 ­ 11: Transmitter Button Select Switches

7.0 Power Power required is 12 VDC nominal at 30 mA, and should be applied where indicated on the 8-position Door terminal block (GND and +12V In). If relay is active, then nominal power is 100 mA. If a separate reader is installed, current may be higher. Maximum reader power is 300 mA. If more current is required, a separate power supply should be used. A linear power supply is recommended for best operation.
8.0 Mounting The Edge Receiver may be mounted indoors or outdoors. The enclosure includes pre-drilled holes in the four corners allowing mounting to a flat surface. Use supplied #6 mounting screws, or equivalent security screws, for installation. To maintain outdoor rating of enclosure when wiring, use supplied Heyco®-Tite liquid tight cord grips on cables.
9.0 Read Range Read range is nominally up to 100 feet (30.5 m). For optimal read range, it is important that the Edge Receiver be mounted as far from potential interference sources as possible. These sources may include, but are not limited to, large metal and concrete obstructions, as well as magnetic fields and radio transmissions. Further range varies based on the height a Receiver is installed, how a user may hold a Transmitter when being used, and where the Transmitter is being used. Avoid installing Receiver inside metal enclosures. Read range may vary for each installation.

12 11 10 9 8 7 6 5 4 3 2 1

Dip Switches 1 ­ 9: Credential Enrollment/Deletion Switches

12 11 10 9 8 7 6 5 4 3 2 1

Dip Switches 1 ­ 4: Relay Activation Timing Switches

QUICK START GUIDE RER-11 RANGER® EDGE RECEIVER

10.0 8-Position Door Terminal Block Connections

DPS

Door Position Sensor

GND

Ground

REX

Request to Exit device

RLY/NO

Relay Normally Open

RLY/CMN

Relay Common

RLY/NC

Relay Normally Closed

GND

Power, 0VDC (Power supply)

+12V In

Power, +12VDC (Power supply input)

11.0 6-Position Wiegand Interface Terminal Block Connections

D1

Wiegand Data 1 (One), Normally White Conductor

D0

Wiegand Data 0 (Zero), Normally Green Conductor

L

LED, Normally Brown Conductor

B

Beeper, Normally Blue Conductor

GND

Ground (0VDC), Normally Black Conductor

+12V OUT

Power (+12VDC), Normally Red Conductor

12.0 Connection Connection must be done in accordance with NFPA 70. Do not connect to a receptacle controlled by a switch. Connect to a power limited DC voltage source.
Operating Temperature: ­40° F to 149° F (­40° C to +65° C) Operating Humidity: 5% to 95% relative humidity non-condensing
IP Rating: IP67-rated for outdoor use
TECHNICAL NOTES Garage Door Applications · Wire the RLY/NO and RLY/CMN connections in parallel to the
Garage Door Opener push button switch activator. · If 12VDC can be found within the garage door opener, it is
possible to provide power to the Ranger Edge Receiver by this means. Otherwise a separate power supply will be required. · A relay timer value of 1 second is typical for this application.
Board Mounting · The Ranger Edge Receiver can be installed into a third-party
device, as permitted. · Do not mount inside a metal enclosure as this will reduce the
operating range of the transmitter.
For information on set-up, please review our Edge Receiver Configuration Reference Document.

SPECIFICATIONS Power Operating Voltage Operating Current

12VDC+/- 10% Nominal Idle: 30mA, Relay Active: 100mA

Relay Output Relay

Form C, NO 5 A @ 30 VDC resistive, NC 3 A @ 30 VDC resistive

Transmitter Interface
Supported Wireless Transmitters

Farpointe Data, Inc. Models WRT-2+, WRT-4+, and WRT-2M

Reader Interface Reader Power
Data Inputs LED Output
Buzzer Output

12VDC +/- 10%, 300 mA maximum for each reader
TTL compatible Wiegand inputs
TTL levels, high>3 V, Low<0.5 V, 5 mA source/sink maximum
Open collector, 12 VDC open circuit maximum, 25 mA sink maximum

Environmental Temperature Humidity

-55 to 85° C storage, 0 to 70° C operating 5 to 95% RHNC

Mechanical Dimensions Enclosure

3" × 3", 0.9" height
Hammond box, P/N: 1555E2GY (UL Listed), included, with 4ea #6 × 1/4", self-tapping PCBA mounting screws

FCC Compliance Statement: This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Caution: Changes or modifications not expressly approved by Farpointe Data could void the user's authority to operate the equipment.
Product can be used without license conditions or restrictions in all European Union countries, including Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Poland, Portugal, Romania, Slovakia, Spain, Sweden, United Kingdom, as well as other non-EU countries, including Iceland, Norway, and Switzerland.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause unde-sired operation of the device.
Cet appareil est conforme à Industrie Canada exempts de licence standard RSS (s). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas provoquer d'interférences et (2) ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif.
Details on compliance and certifications can be found at:
https://www.farpointedata.com/resources/certifications.php.

Farpointe Data reserves the right to change specifications without notice.

© 2022 Farpointe Data, Inc. All rights reserved. Farpointe Data®, Pyramid Series Proximity®, Delta®, Ranger®, and CONEKT® are the registered U.S. trademarks of Farpointe Data, Inc. All other trademarks are the property of their respective owners.

Jul-21-2022

www.farpointedata.com

Farpointe Data, Inc. 2195 Zanker Road San Jose, CA 95131 USA Office: +1-408-731-8700 Fax: +1-408-731-8705 support@farpointedata.com
P/N: 01190-001  Rev. 1

