Installation Guide for Altronix models including: Trove1C1, TC1, Trove2CV2, TCV2, Trove3CV3, TCV3, Trove1 Enclosure

IITrove CDVI I24U

Click to View

Altronix TROVE2CV2 | Altronix/CDVI Access and Power Integrat


File Info : application/pdf, 12 Pages, 1.00MB

PDF preview unavailable. Download the PDF instead.

Altronix TCV2 Backplane Installation Instructions
Access & Power Integration

SIGNALING

Trove1C1
- Trove1 enclosure with Altronix/CDVI backplane (TC1)
TC1
- Altronix/CDVI backplane only
Trove2CV2
- Trove2 enclosure with Altronix/CDVI backplane (TCV2)
TCV2
- Altronix/CDVI backplane only
Trove3CV3
- Trove3 enclosure with Altronix/CDVI backplane (TCV3)
TCV3
- Altronix/CDVI backplane only
Installation Guide

All registered trademarks are property of their respective owners.

More than just power.TM

Rev. TCDVI011117 Installing Company: _________________________ Service Rep. Name: __________________________________________

Address: _________________________________________________________ Phone #: _________________________

Overview: Trove1C1, Trove2CV2 and Trove3CV3 accommodate various combinations of CDVI boards with or without Altronix power supplies and accessories for access control systems.

Specifications: · 16 Gauge backplane and enclosure with ample knockouts for convenient access.

Trove1C1

Trove2CV2

Trove1 enclosure with

Trove2 enclosure with

TC1 Altronix/CDVI backplane · Includes: tamper switch, cam lock,
and mounting hardware. Enclosure Dimensions (H x W x D): 18" x 14.5" x 4.625" (457mm x 368mm x 118mm).

TCV2 Altronix/CDVI backplane · Includes: tamper switch, cam lock,
and mounting hardware. Enclosure Dimensions (H x W x D): 27.25" x 21.75" x 6.5" (692.15mm x 552.5mm x 165.1mm).

Trove3CV3
Trove3 enclosure with
TCV3 Altronix/CDVI backplane · Includes: two (2) tamper switches, cam
lock, and mounting hardware. Enclosure Dimensions (H x W x D): 36.12" x 30.125" x 7.06" (917.5mm x 768.1mm x 179.3mm).

TC1
Altronix/CDVI backplane only · Includes mounting hardware.
Dimensions (H x W x D): 16.625" x 12.5" x 0.3125" (422.3mm x 317.5mm x 7.9mm).

TCV2
Altronix/CDVI backplane only · Includes mounting hardware.
Dimensions (H x W x D): 25.375" x 19.375" x 0.3125" (644.5mm x 482.6mm x 7.9mm).

TCV3
Altronix/CDVI backplane only · Includes mounting hardware.
Dimensions (H x W x D): 34" x 28" x 0.3125" (863.6mm x 711.2mm x 7.9mm).

TC1 accommodates a combination
of the following: Altronix Modules: · One (1) AL400ULXB2, AL600ULXB,
AL1012ULXB, AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB or eFlow104NB. · One (1) ACM4(CB), MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), VR6. CDVI Modules: · Four (4) A22K/A22NB/ADH10 modules.

TCV2 accommodates a combination
of the following: Altronix Modules: · Two (2) AL400ULXB2, AL600ULXB,
AL1012ULXB, AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB or eFlow104NB. · One (1) ACM8(CB), or two (2) MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), VR6. CDVI Modules: · Five (5) A22K/A22NB/ADH10 modules.

TCV3 accommodates a combination
of the following: Altronix Modules: · Up to four (4) AL400ULXB2, AL600ULXB,
AL1012ULXB, AL1024ULXB2, eFlow4NB, eFlow6NB, eFlow102NB or eFlow104NB. · Up to four (4) ACM8(CB), MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), VR6. CDVI Modules: · Ten (10) A22K/A22NB/ADH10 modules.

Agency Listings: · UL 294 - 6th edition: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II*.
* Stand-by Power Level I if no battery is supplied. · This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada. · CE European Conformity.

Installation Instructions for Trove1, Trove2, Trove3:

1. Remove backplane from enclosure prior to mounting (do not discard hardware).

2. Trove1C1 (Pg. 8):

Mark and predrill holes on the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in

the wall with the screw heads protruding. Place the enclosure's upper keyholes over the two upper screws; level and secure.

Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners.

Place the enclosure's upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws.

Trove2CV2 and Trove3CV3 (Pg. 10 and Pg. 12): Mark and predrill holes on the wall to line up with the top three keyholes in the enclosure. Install three upper

Fig. 1

fasteners and screws in the wall with the screw heads protruding. Place the enclosure's upper keyholes over

the three upper screws; level and secure. Mark the position of the lower three holes. Remove the enclosure.

Edge of

Drill the lower holes and install the three fasteners. Place the enclosure's upper keyholes over the three

Enclosure

Enclosure

upper screws. Install the three lower screws and make sure to tighten all screws. 3. Mount included UL Listed tamper switch(es) (Altronix Model TS112 or equivalent) in desired location,

Tamper Switch (provided)

opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2" from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate

To Access Control Panel or UL Listed Reporting Device

UL Listed reporting device. To activate alarm signal open the door of the enclosure.

4. Mount Altronix/CDVI modules to TC1, TCV2 or TCV3 backplane, refer to pages 3, 4, 5.

- 2 -

Trove / CDVI Installation Guide

TC1: Configuration of Altronix Power Supply and/or Sub-Assembly Boards and CDVI Modules 1. Fasten spacers (provided) to pems that match the hole pattern for Altronix Power Supply/Chargers or Altronix Sub-Assembly boards (Fig. 2, pg. 3). Fasten metal spacers in the correct locations to provide proper grounding, see below (Fig. 2, pg. 3). 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 2a, pg. 3). 3. Mount appropriate CDVI A22K/A22NB/ADH10 modules into the correct positions (Fig. 2, pg. 3) by postioning spacers over appropriate holes on the backplane and depress down on board to secure spacer to the backplane (Fig. 2, 2b, 2c, pg. 3). Note: CDVI A22K/A22NB/ADH10 modules have one (1) RJ45 jack each. Please make sure that they are mounted correctly, as shown in Fig. 2 below. 4. Fasten TC1 backplane to Trove1 enclosure utilizing pan head screws (provided).
Fig. 2 - Trove1C1/TC1 Configurations

Metal Spacer Placement

Altronix Power Supply

Altronix Sub-
Assembly

CDVI A22K/A22NB/ADH10
RJ45 Jack

CDVI A22K/A22NB/ADH10
RJ45 Jack

RJ45 Jack
CDVI A22K/A22NB/ADH10

RJ45 Jack
CDVI A22K/A22NB/ADH10

RJ45 Jack
CDVI A22K/A22NB/ADH10

RJ45 Jack
CDVI A22K/A22NB/ADH10

Fig. 2a

Fig. 2b

Pan Head Screw

Pem Spacer

Altronix Power Supply or Sub-Assembly

Backplane

Spacer
Backplane
CDVI - A22K/A22NB/ADH10 Access Controller

Fig. 2c Plastic Spacer pre-mounted into CDVI Atrium modules
Insert into TC1/TCV2/TCV3 backplane

Trove / CDVI Installation Guide

- 3 -

TCV2: Configuration of Altronix Power Supply and/or Sub-Assembly Boards and CDVI Modules 1. Fasten spacers (provided) to pems that match the hole pattern for Altronix Power Supply/Chargers or Altronix Sub-Assembly boards (Fig. 3, pg. 4). Fasten metal spacers in the correct locations to provide proper grounding, see below (Fig. 3, pg. 4). Note: Altronix sub-assembly position can accommodate either one (1) ACM8/ACM8CB or two (2) PD4UL/PD4ULCB, PD8UL/PD8ULCB or MOM5. 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 3a, pg. 4). 3. Mount appropriate CDVI A22K/A22NB/ADH10 modules into the correct positions (Fig. 3, pg. 4). by positioning spacers over appropriate holes on the backplane and depress down on board to secure spacer to the backplane (Fig. 3, 3b, 3c, pg. 4). Note: CDVI A22K/A22NB/ADH10 modules have one (1) RJ45 jack each. Please make sure that they are mounted correctly, as shown in Fig. 3 below. 4. Fasten TCV2 backplane to Trove2 enclosure utilizing pan head screws (provided).
Fig. 3 - Trove2CV2/TCV2 Configurations
Fig. 3a

Altronix Power Supply

RJ45 Jack CDVI - A22K/A22NB/ADH10

Pan Head Screw

Pem Spacer

Altronix Power Supply or Sub-Assembly

Backplane

Metal Spacer Placement

Fig. 3b

Altronix Power Supply or
Sub-Assembly
Metal Spacer Placement

RJ45 Jack CDVI - A22K/A22NB/ADH10

Spacer
Backplane
CDVI - A22K/A22NB/ADH10 Access Controller

Altronix Sub-Assembly

RJ45 Jack CDVI - A22K/A22NB/ADH10

Fig. 3c
Plastic Spacer pre-mounted into CDVI Atrium modules

RJ45 Jack CDVI - A22K/A22NB/ADH10

RJ45 Jack CDVI - A22K/A22NB/ADH10

Insert into TC1/TCV2/TCV3 backplane

- 4 -

Trove / CDVI Installation Guide

TCV3: Configuration of Altronix Power Supply
and/or Sub-Assembly Boards and CDVI Modules 1. Fasten spacers (provided) to pems that match the hole pattern for Altronix Power Supply/Chargers or Altronix Sub-Assembly boards
(Fig. 4, pg. 5). Fasten metal spacers in the correct locations to provide proper grounding, see below (Fig. 4, pg. 5). Note: Altronix sub-assembly positions can accommodate two (2) PD4UL/PD4ULCB, PD8UL/PD8ULCB or MOM5. 2. Mount boards to spacers utilizing 5/16" pan head screws (provided) (Fig. 4a, pg. 5). 3. Mount appropriate CDVI A22K/A22NB/ADH10 modules into the correct positions (Fig. 4, pg. 5). by positioning spacers over appropriate holes on the backplane and depress down on board to secure spacer to the backplane (Fig. 4, 4b, 4c, pg. 5). Note: CDVI A22K/A22NB/ADH10 modules have one (1) RJ45 jack each. Please make sure that they are mounted correctly, as shown in Fig. 4 below. 4. TCV3 backplane installation: refer to note below drawing and Fig. 4d, pg. 5. 5. Fasten TCV3 backplane to Trove3 enclosure utilizing pan head screws (provided).

Fig. 4 - Trove3CV3/TCV3 Configurations

Fig. 4a

Altronix Power Supply
Metal Spacer Placement
Altronix Power Supply
Metal Spacer Placement
Altronix Sub-Assembly

RJ45 Jack CDVI - A22K/A22NB/ADH10
RJ45 Jack CDVI - A22K/A22NB/ADH10
RJ45 Jack CDVI - A22K/A22NB/ADH10

RJ45 Jack CDVI - A22K/A22NB/ADH10
RJ45 Jack CDVI - A22K/A22NB/ADH10
RJ45 Jack CDVI - A22K/A22NB/ADH10

Pan Head Screw

Pem Spacer

Altronix Power Supply or Sub-Assembly

Backplane

Fig. 4b

Spacer
Backplane
CDVI - A22K/A22NB/ADH10 Access Controller

Altronix Sub-Assembly

RJ45 Jack CDVI - A22K/A22NB/ADH10

RJ45 Jack CDVI - A22K/A22NB/ADH10

Fig. 4c
Plastic Spacer pre-mounted into CDVI Atrium modules

Altronix Sub-Assembly
Altronix Sub-Assembly

RJ45 Jack CDVI - A22K/A22NB/ADH10

RJ45 Jack CDVI - A22K/A22NB/ADH10

Insert into TC1/TCV2/TCV3 backplane
Fig. 4d

Note: TCV3 bumper installation. Prior to mounting TCV3 install rubber bumpers (included) to the back of backplane, one (1) on top and one (1) on bottom, approximately 1" from the cutouts (Fig. 4d, pg. 5).
Bumpers are pre-installed in Trove3CV3
Trove / CDVI Installation Guide

Rubber Bumper
Back of Cutout Backplane
- 5 -

Notes:

- 6 -

Trove / CDVI Installation Guide

TC1 Dimensions 16.625" x 12.5" x 0.3125" (422.3mm x 317.5mm x 7.9mm)
12.5" (317.5mm) 0.5" (12.7mm)

8.15" (207mm)

15.65" (397.5mm)

16.625" (422.3mm)

0.5" (12.7mm) 6.25" (158.75mm)

Trove / CDVI Installation Guide

- 7 -

Trove1C1 Enclosure Dimensions (H x W x D): 18" x 14.5" x 4.625" (457mm x 368mm x 118mm)

14.5" (321.3mm) 7.25" (184.2mm)

1.45" (36.8mm)

1.95" (49.5mm)

1.5" (38.1mm)

4.5" (114.3mm) 1.25" (31.8mm)

0.57" (14.5mm)

0.6" (15.2mm)

13.0" (330.2mm)

1.25" (31.8mm)

1.5" (38.1mm)

8.5" (215.9mm)

8.5" (215.9mm)

18.0" (457.2mm)

6.5" (165.1mm)

6.5" (165.1mm)

0.6" (15.2mm) 1.1" (27.9mm)
4.5" (114.3mm)

4.5" (114.3mm)

2.75" (69.9mm)

1.115" (28.3mm)

1.36" (34.5mm)

1.25" (31.8mm)

- 8 -

Trove / CDVI Installation Guide

0.45" (11.4mm)

TCV2 Dimensions 25.375" x 19.375" x 0.3125" (644.5mm x 482.6mm x 7.9mm).

2.2" (55.9mm)

19.375" (492.1mm)

2.2" (55.9mm)

0.156" ( 3.96mm)

25.375" (644.6mm)

8.5" (215.9mm) 12.625" (320.7mm) 16.25" (412.8mm)

0.45" (11.4mm)

1.0" (25.4mm)
7.5" (190.5mm) 9.2" (233.7mm)

1.0" (25.4mm) 7.5" (190.5mm) 9.2" (233.7mm)

Trove / CDVI Installation Guide

- 9 -

2.00" (50.8mm)

1.25" (31.8mm)

6.25" (158.8mm) 1.25" (31.8mm)

1.5" (38.1mm)

Trove2CV2 Enclosure Dimensions (H x W x D): 27.25" x 21.75" x 6.5" (692.15mm x 552.5mm x 165.1mm)

21.50" (546.1mm) 5.25" (133.35mm) 3.5"(88.9mm) 3.5"(88.9mm) 5.25" (133.35mm)

2.00" (50.8mm)

6.25" (158.8mm)

0.5625" (14.3mm)

0.685" (17.4mm)

1.77" (45mm)

Knockouts 1.125" (28.3mm)

2.415" (61.3mm) 0.885" (22.5mm)

19.80" (502.9mm)

2.00" (50.8mm)

6.75" (171.5mm)

8.25" (209.5mm)

27" (685.8mm)

8.00" (203.2mm)

1.00" (25.4mm)

0.85" (21.6mm)

1.25" (31.8mm)

2.00" (50.8mm)

2.00" (50.8mm)

5.25" (133.4mm)

7.00" (177.8mm)

5.25" (133.4mm)

1.25" (31.8mm) 2.00" (50.8mm)

- 10 -

Trove / CDVI Installation Guide

0.45" (11.4mm)

2.5" (63.5mm)

TCV3 Dimensions 34" x 28" x 0.3125" (863.6mm x 711.2mm x 7.9mm)
28" (711.2mm)

0.156" ( 3.96mm)

34" (863.6mm)

25" (635mm)

13.5" (342.9mm)

2" (50.8mm)

1.0" (25.4mm)
13.5" (342.9mm)

1.0" (25.4mm)

13.5" (342.9mm)

Trove / CDVI Installation Guide

- 11 -

2.00" (50.8mm)

Trove3CV3 Enclosure Dimensions (H x W x D approximate): 36.12" x 30.125" x 7.06" (917.5mm x 768.1mm x 179.3mm)

2.00" (50.8mm) 1.25" (31.8mm)

7.12" (222.3mm)

9.5" (241.3mm)

9.5" (241.3mm) 1.78" (45.2mm)

1.55" (39.4mm)

1.25" (31.8mm)

1.07" (27.2mm)

30.12" (768.1mm) 14.01" (355.9mm)

14.01" (355.9mm)

2" (50.8mm)

1.10" (27.9mm)

G G

10.75" (273.1mm)

10.75" (273.1mm)

10.62" (269.8mm) 36.12" (917.5mm)

33.63" (854.2mm)

10.62" (269.8mm)

10.75" (273.1mm)

10.75" (273.1mm)

1.25" (31.8mm)

2"

8.75" (222.3mm)

(50.8mm)

8.62" (219mm)

8.75" (222.3mm)

7.06" (179.3mm)

1.25" (31.8mm)

Altronix is not responsible for any typographical errors. ­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­­ 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056

web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty

IITrove / CDVI

I24U

MEMBER

- 12 -

Trove / CDVI Installation Guide



References

Adobe PDF Library 16.0 Adobe InDesign 16.4 (Macintosh)