ST01/ST01K/EI600
In-Wall Timer with Astro Feature
Installation and User Guide

RATINGS

ST01/ST01K

EI600

Operating Voltage

120-277 VAC, 50/60 Hz

Resistive (heater)

15 A, 120-277 VAC 20 A, 120-277 VAC

Tungsten (incandescent)

15 A, 120 VAC; 6 A, 208-277 VAC

Ballast (fluorescent)

8 A, 120 VAC; 4 A, 208-277 VAC

16 A, 120-277 VAC

Motors

1 HP, 120 VAC; 2 HP, 240 VAC

DC Loads

4 A, 12 VDC; 2 A, 28 VDC

Operating Temperature

32° F to 104° F (0° C to 40° C)

Dimensions 4 1/8" H x 1 3/4" W x 1 13/16" D

SAFETY SECTION
WARNING
Risk of Fire or Electric Shock · Disconnect power at the circuit breaker(s) or disconnect
switch(es) before installing or servicing (including replacing the battery). · Installation and/or wiring must be in accordance with national and local electrical code requirements. · Use COPPER conductors ONLY. · Do Not recharge, disassemble, heat above 212° F (100° C), crush, or incinerate the Lithium battery. Keep out of reach of children. · Replace battery with Type CR2 only that is certified by Underwriters Laboratories (UL). · Do NOT use timer to control devices that could have dangerous consequences due to inaccurate timing, such as: sun lamps, saunas, heaters, slow cookers, etc.
NOTICE
· Risk of timer damage due to leakage if weak battery is not replaced promptly.
· Dispose of product per local regulations for disposal of Lithium batteries.

PRODUCT DESCRIPTION
The ST01 Series and EI600 Series In-Wall Timers give you versatility in a simple to install, 24/7 programmable package. These timers allow you to customize your timer schedule with automatic dusk/ dawn, random, and Daylight Saving Time (DST) programming options for up to 40 ON/OFF events. The ST01 Series and EI600 Series are incandescent/ fluorescent/CFL/LED compatible. In addition, these timers can handle any load type and require no neutral wire connection, making them ideal for any application, regardless of complexity.
TIMER INTERFACE
Display
­ button (Decrease) Mode button + button (Increase)
Reset button On/Off button
Access door to battery tray
PRE-INSTALLATION
Before mounting the timer in the wall, install the supplied battery. 1. Gently pry open the access door, located below
ON/OFF, and remove the battery tray from the timer. 2. Place the supplied CR2 battery into the battery tray, matching the battery + and ­ markings to the + and ­ markings on the tray, then place the battery tray back in the timer. 3. The display initializes, then flashes 12:00 am in manual mode. 4. Press ON/OFF. The timer "clicks" to confirm it is ready for programming. Note: If the display doesn't flash 12:00 am, check/replace
the battery before proceeding.

NOTES
Read these notes before continuing with the timer installation and programming process. · The timer is battery-powered and does not need
AC power for initial setup and programming. For new installations, it is recommended that you setup and program your timer before installing it. · The battery controls the ON/OFF function ("clicking" sound) and maintains the time and date. The screen flashes BATT when the battery strength is low. When replacing the battery, disconnect AC power. You will have a few minutes to insert new batteries before the date and time settings are lost. All other settings will remain in memory, without battery or AC power. · Each ON or OFF setting is an event. Each event must be programmed separately. · The MODE menu includes SETUP, PGM (program), AUTO (automatic), RAND (random), and MAN (manual). AUTO and RAND modes do not appear on the menu options until the time of day is set and at least one ON or OFF event is programmed. · All menus loop (repeat options when you get to the end of the menu). When in a specific Mode, press ON/OFF to loop within that Mode. · When using the + or ­ buttons to change a flashing setting, hold the button to make the numbers scroll faster. · When advancing to the next setting, the timer automatically saves the data from the previous screen whether you changed a setting or not. All settings save automatically after five minutes.
PROGRAMMING
Follow these steps for initial setup and programming of the ST01 Series and EI600 Series timers.
Clear All Existing Settings
When first setting the timer, it is recommended that any existing settings be cleared. 1. Press and hold ON/OFF button.
2. Using a paper clip or pen, press and release the RESET button. The timer displays INIT after approximately five seconds.
3. Release the ON/OFF button. All previous settings are removed.

Initial Setup

1. Press MODE until SETUP appears on the display.
2. Press ON/OFF to advance to the next menu item (HOUR).
3. Press + or - to adjust the flashing menu item (HOUR).
4. Press ON/OFF to advance to the next menu item (MINUTES).
5. Repeat steps 3 & 4 to set the MINUTES, YEAR, MONTH, and DATE.

Note: After setting the DATE, the current day of the week flashes. Verify the DAY. If wrong, press + or - to review and adjust the YEAR, MONTH, and DAY. Press ON/ OFF to confirm.

6. The DST selections (AUTO or MAN) flash on the display.
· Press + to change the selection.
­ Select AUTO if your location observes DST.
­ Select MAN to disable automatic DST adjustment.
· Press ON/OFF to confirm and advance to ZONE selection.

Note: The remaining settings for initial setup (ZONE, DAWN, and DUSK settings) are only used for regulating Astronomic events. There is no need to adjust these settings if you are not scheduling an Astronomic event.

7. The ZONE selections* (CENT, SOU, or NRTH) flash on the display.

· Press + to change the selection to match your location on the map.

NORTH CENTRAL
SOUTH

· Press ON/OFF to confirm and advance to DAWN/DUSK selection.

Note: Astronomic adjustment on this product is designed for the continental United States. Astronomic schedules are not recommended for locations substantially beyond the continental US borders, including Alaska. For southern Canada, select "NRTH" zone. For northern Mexico, select "SOU" zone. Please visit www.intermatic.com for other timer models offering expanded Astronomic geographic coverage.

8. The hours digit of the current day's DAWN time flashes on the display. · Press + or - to adjust the hour, as necessary. · Press ON/OFF to confirm and advance to the DAWN minutes digit. · Press + or - to adjust the minutes, as necessary · Press ON/OFF to confirm and advance to the DUSK hours digit. · Use the same process for setting the DAWN time to set the time for DUSK.
Note: Locate the current day's dusk and dawn times in a local paper or online. You may deliberately adjust DUSK and/or DAWN settings up to +/- 120 minutes, if desired, to cause Astronomic events to always occur a predictable amount of time before or after the actual dusk or dawn.
9. The timer loops to the beginning of the SETUP mode. · Press ON/OFF repeatedly to review/revise your settings, or press MODE to exit SETUP.
Programming Events
Note: Program ON and OFF events as separate events.
1. Press MODE until PGM appears on the display.
2. Press ON/OFF to confirm. An event number flashes on the display.
Note: If this is the first event, you will see 01.
3. Press ON/OFF to confirm the event number. An event type flashes on the display.
4. Use + to select the event type. · ON - sets an ON event · SKIP - stops the event · OFF - sets an OFF event
5. Press ON/OFF to confirm. An event time type flashes on the display.
6. Use + to select a time type. · DAWN · DUSK · Fixed Time
Note: To set a Fixed Time, press ON/OFF, then + or - to adjust the hour. Press ON/OFF. Use the same process to set minutes.
7. Press ON/OFF to confirm. A day selection flashes on the display.

8. Use + to select the days the event runs. · ALL - all seven days of the week · M-F - Monday through Friday · WKD - Saturday and Sunday · Individual day - select: SUN, MON, TUE, WED, THU, FRI, or SAT
9. Press ON/OFF to confirm. The display reads SAVE, then flashes the event number to indicate the event is saved.
Note: To continue programming events, use + to advance to the next event number, then repeat steps 3 through 9.

Selecting Operating Modes

AUTO

Timer operates per your programmed schedule of ON/OFF events.

RAND MAN

Timer operates your schedule at +/- 15 minutes from the programmed time.
Operates like a manual ON/OFF switch, disregards any programmed events.

Note: To set the timer to recognize your programmed events, press MODE to scroll to AUTO or RAND only.

Reviewing/Changing Clock Time, Calendar, or Astronomic Settings
Repeat the steps under "Initial Setup" to review and make setting changes, as needed.
Changing Events
1. Press MODE until PGM appears on the display.
2. Press ON/OFF to confirm. An event number flashes. Use + to find the correct event number.
3. Press ON/OFF to confirm. · To change the ON/OFF status of an event, use + to select the event type. ­ ON - sets a previously OFF event to ON ­ SKIP - suppresses the selected event so it is not initiated by the timer. This is helpful for unusual programming needs, like vacation settings. ­ OFF - sets a previously ON event to OFF · To update an existing setting, press ON/OFF until the setting to be updated displays. ­ Press + to adjust the setting.
4. Press ON/OFF to cycle through the program until the display reads SAVE.
5. Press MODE to exit the programming menu.

INSTALLATION

1. Disconnect the power at the service panel.

2. Remove wall switches, if applicable.

3. Strip the existing wire ends to 7/16".

7/16"

4. Wire the timer into the wall box. An example of single-pole and three-way wiring follow. For other three-way wiring scenarios, go to www.intermatic.com.

Single-Pole Wiring

Line Wire A

Wire B

Timer

Wire D

Wire C

Neutral

Load

A Black -- Connects to the hot (black) wire from the Power Source
B Blue -- Connects to the other wire (black) from the load
C Red -- This wire is not used in single-switch installations. Cap with a twist connector
D Green -- Connects to the supplied ground

Three-Way Wiring
Note: The distance between the timer and the remote switch must not exceed 100 feet.
The wiring shown is for a timer replacing a three-way switch at the line side. For other installations, visit www.intermatic.com or consult a qualified electrician.

Line Wire A

Wire B

Timer

Wire D

Wire C

Wire E 3-Way
Switch

Neutral

Load

A Black -- Connect to the wire removed from the "COMMON" terminal of the switch being replaced
B Blue -- Connect to one of the other wires removed from the switch being replaced. Record the wire color connected to the blue wire for use during load-side installation
C Red -- Connect to the remaining wire removed from the switch being replaced. Record the wire color connected to the red wire for use during load-side installation
D Green -- Connect to the supplied ground
E Jumper Wire -- At the other three-way switch, install the supplied jumper wire between wire B and the common terminal

Finalizing Installation
1. Make sure the provided twist-on wire connectors are secure, then tuck the wires into the timer wall box, leaving room for the timer.
2. Using the provided screws, secure the timer to the wall box.
3. Cover the timer with the wall plate and secure using the provided screws.
4. For three-way wiring, install the remote switch in wall box. Cover the switch with the wall plate and secure.
5. Reconnect the power at the service panel.
TESTING THE TIMER
Make sure the timer displays MAN MODE during testing.
Single-Pole Wiring Test
To test the timer, press ON/OFF several times. The timer should "click" and the controlled light or device (load) should turn ON or OFF.
Three-Way Wiring Test
1. To test the timer, test with the remote switch in each of its two positions.
2. Press ON/OFF several times. The timer should "click" and the controlled light or device (load) should turn ON or OFF.
3. If the timer clicks, but the load does not operate: a. Disconnect the power at the service panel. b. Re-check your wiring and make sure the load is functional. c. Reconnect the power at the service panel. d. Retest.
4. If the timer clicks, but the load only operates when the remote switch is in one of its two positions, repeat Step 3, a-d, but interchange the two traveler wires (wires between the timer and the remote three-way switch) connected to the red and blue timer wires.
Note: Consult a qualified electrician if the switch and timer fail to operate as intended.
5. When the timer "clicks" and the controlled device turns ON and OFF as appropriate, congratulations, the timer is successfully installed!
Enjoy your new timer!

TROUBLESHOOTING

Observed Problem Possible Cause

What To Do

Timer display is Battery is missing, Attempt to

blank and the timer has no charge, or was reinsert the

does not "click" installed incorrectly. battery. If the

when the ON/OFF

problem persists,

button is pushed.

insert a fresh

battery.

Timer does not switch ON/OFF but display looks normal.

Timer is not set in AUTO, RAND, or MAN mode.

Press MODE to select the operational mode you want to use.

Timer resets to 12:00.

Timer is installed in conjunction with a contactor or motor load.

Install a line filter.

Timer won't enter Auto or Random mode when you press Mode.

No schedule is selected.

Define a schedule of events.

Timer switches at incorrect times or skips some of the programmed times.

The active schedule has a conflicting setting.

Review the settings and revise them as necessary.

Timer is in Random Select the Auto mode, which varies Mode. switching times up to +/- 15 minutes.

The Astronomic and Review your Defined switching program settings times are in conflict, and revise them your DST may or may as necessary. not be turned on, and/ or your Astronomic Zone is not set to Center, North, or South. Note: Your timer automatically skips any conflicting ON event as summer approaches to prevent unwanted operation of lights or other controlled devices.

Switching inductive Add a noise

loads, such as

filter e.g., ET-NF.

electrical contactor or Connect filter

motor load.

across load's

coil.

Load only operates The remote switch is when the remote wired incorrectly. (three-way) switch is in one position or the timer ignores the remote switch.

Recheck the wiring, especially for the jumper.

TROUBLESHOOTING (CONT.)

Observed Problem Possible Cause

What To Do

The timer ignores a · The remote switch Contact a

three-way remote or timer is wired qualified

switch even though wrong.

electrician.

it is wired correctly · There is an

or the load turns excessive length of

off immediately wire (greater than

after being turned 100 feet).

ON.

· There is buried

wire to the remote

switch.

· The remote switch

is not functioning

properly or worn out.

The battery tray is Battery is not seated difficult to replace. in the tray.
· The tray is misaligned. · The contact tabs of
the tray are bent

Seat the battery in the tray, then reinstall.

The timer operation Though the "BATT" Replace the

is sluggish or not message is not being battery. To test

switching

displayed, the battery the battery,

ON/OFF at all. is getting weak.

press the ON/

OFF button. The

timer should

"click."

Timer shows ON but the light or other controlled device is OFF.

The light or controlled Make sure

device itself may be the light or

switched OFF.

controlled device

is switched ON

and plugged in.

Note: When installing a timer with either a contactor or motor load, a line filter is recommended.

LIMITED WARRANTY
For detailed warranty information, refer to the Intermatic website at www.intermatic.com, contact Intermatic by mail at Intermatic Incorporated Customer Service / 7777 Winn Rd., Spring Grove, Illinois 60081­9698, or by phone at: 815-675-7000.