Owner's Manual for LED models including: LED Array Series Indoor Display, LED Array Series, Indoor Display, Display

T8000-ANN

ryan

Click here to download

LED Array Series Indoor displays - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications


File Info : application/pdf, 6 Pages, 1.15MB

PDF preview unavailable. Download the PDF instead.

?tmstv=1676770495
MNS LEDARRAY

INDOOR DISPLAY

SERIES

Graphic Annunciators * Water Leak Detection Fireman's Smoke Control Panels * ARA Systems
109 Portwatch Way Wilmington, N.C. 28412 Phone: (800) 251-2512 Fax: (800) 251-9878 Internet: www.ledinc.com Email: sales@ledinc.com

M ASS N OT I FI CAT I ON SYSTEM SERIES

General Description
The LEDArray Series Indoor displays are LED message centers designed for light industrial, commercial and office use. They quickly display large amounts of information in 8 colors and 3 rainbow effects (red only versions are also available). These message centers are among the brightest and sharpest indoor displays available.
Messages are entered through a wireless, remote control keyboard, as easy to understand and use as an ordinary calculator. Exclusive 3-step message entry with Automode programming eliminates the need to learn complicated programming procedures. Within seconds, the user can create exciting visual messages that cannot be ignored. 10 preset mass notification messages are provided.
In applications requiring multiple units to communicate important information, Alpha displays can be networked and connected to a PC, to form a powerful integrated visual information system throughout your plant or business facility, or the LED Contact Interface Panel can be used for Fire Alarm or Manual type activation.
1
firealarmresources.com

MNS LEDARRAY

SERIES

INDOOR DISPLAY

LEDArray Specifications - L.E.D. Mass Notification System

Case Dimensions: (With power supply)
Approximate Weight:

Sizes

Display Dimensions:

Display Array: Characters Displayed in one-line (minimum): Display Memory:

LEDArray
28.9"L x 2.1"D x 4.5"H (73.4 cmL x 5.3 cmD x 11.4 cmH)
6.25 lbs (2.13 kg.)
27"L x 2.1"H (68.6 cmL x 5.3 cmH)
90 x 7 pixels
15 characters
7,000 characters

Pixel Size (Diameter): Pixel (LED)Color: Center-to-Center Pixel Spacing (Pitch): Character Size: Character Set: Memory Retention: Message Capacity: Message Operating Modes:
Built-in Animations:
Real-Time Clock:

0.2" (.05 cm)
Red
0.3" (0.8 cm)
2.1" (4.3 cm)
Block (sans serif), decorative (serif), upper/lower case,, slim/wide
One month typical
81 different messages can be stored and displayed
­25 consisting of: Automode, Hold, Interlock, Roll (6 directions), Rotate, Sparkle-On, Twinkle, Spray-on, Slide-Across, Switch, Wipe (6 directions), Starburst, Flash, Snow, Scroll Condensed Rotate
­Continuous message entry with automatic centering in any mode
­User programmable logos and graphics ­ Five hold speeds
Cherry Bomb Exploding, Don't Drink and Drive, Fireworks, Slot Machine, No Smoking, Running Animal, Moving Auto, Welcome and Thank You
Date and time, 12 or 24 hour format, maintains accurate time without power for up to 30 days typical

Serial Computer Interface:
Power: Power Cord Length: Keyboard: Case Material: Limited Warranty: Agency Approvals:
Operating Temperature: Humidity Range: Mounting:

RS232 and RS485 (multi-drop networking for up to 255 displays) Options:Ethernet LAN adapter
Input: 5A, 35W, 7 VAC 120 VAC OR 230 VAC adapter available
10 Ft. (3m)
Handheld, Eurostyle, IR remote operated
Molded plastic
One-year parts and labor, factory servicing
­ 120 VAC Model: Power supply has UL/CSA listing. ­ 230 VAC Models: Complies with EN 60950:
1992 (Europe). ­ FCC Part 15 Class A ­ Marked
32°to 120°F, 0°to 49°C
0% to 95% non-condensing
Hardware to accommodate ceiling or wall mounting

2

firealarmresources.com

MNS LEDARRAY

INDOOR DISPLAY

SERIES

LEDArray Mounting Instructions

Model (weight)

Mounting Instructions

Wall

Ceiling

Counter

PPD (1 lb 5 oz, 595.35 g)

Ceiling mounts 9 3/8" (23.8 cm) apart
Wall mounting holes 4" (10.2 cm) apart

The mounting bracket and screws are included.

The mounting bracket and screws are included.

Flip-up ceiling mounts 24" (61 cm) apart

1

LEDArray (6.25 lb, 2.83 kg)

Wall mounting holes 24" (61 cm) or 16" (40.6 cm) apart or
A mounting kit (pn 1040-9005) can be used to mount the sign on a wall, ceiling, or counter. (The kit contains brackets that attach to the end of the sign and can swivel.)

The flip-up ceiling mounts will come out if the sign is turned over.

The sign will stand up if placed on a counter. However, for greater stability, use a mounting kit (pn 1040-9005).

MegaDot (12.25 lbs, 5.6 kg)

1. Attach two wall brackets in the mounting kit (pn 1038-9003) to a wall 46 3/4" (118.7 cm) apart. (measured from the center of each bracket).
2. Attach the mounting brackets to the sign as shown. Wall mounting distance
Lock washers

Using the mounting kit (pn 1038-9003) and a chain (not supplied in the kit), mount the sign from the ceiling as shown:

The sign will stand up if placed on a counter. However, for greater stability, use the mounting kit (pn 1038-9003):

P/N

DESCRIPTION

A

---

Ferrite: Insert the end of the 4-conductor data cable (B) with the ferrite core into the RJ11 port on the electronic display - the ferrite core must be closer to the electronic display than it is to the modular network adapter.

B 1088-8624 RS485 2.5m cable 1088-8636 RS485 0.3m cable

C 4331-0602 Modular Network Adapter

D

1088-8002

RS485 (300m) bulk, used to connect a modular network adapter to a convertor box or to another modular network adapter.

E 1088-1111 RS232/RS485 convertor box

BEFORE MOUNTING A SIGN, REMOVE POWER FROM THE SIGN!
WARNING
Hazardous voltage. Contact with high voltage may cause death or serious injury. Always disconnect power to sign prior to servicing.

NOTE: LEDArray signs are for indoor use only and should not be continuously exposed to direct sunlight.
NOTE: Mounting hardware that is used to hang or suspend a sign must be able of supporting at least 4 times the weight of the sign. 3

firealarmresources.com

MNS LEDARRAY

SERIES

INDOOR DISPLAY

DRY CONTACTS TO RS-485 DATA INTERFACE
Model: MNS-ctrl - for LEDArray and MegaDot signs

The ALPHA Discrete Input Interface allows messages to be displayed on standard LEDArray electronic signs by using simple on/off contacts to trigger messages that have been stored in a sign. The ALPHA Discrete Input Interface is designed for low-voltage applications.
Messages to be displayed are stored in a sign using either: · Infrared handheld remote control · Adaptive software such as ALPHA Messaging software

order:

The ALPHA Discrete Input Interface consists of two types of modules which are connected together
· CPU / Input Module -- serves as an interface between the Input Modules and LEDArray signs. Up to four Input modules can be used, depending on the Operating Mode used. The eight, dry contact inputs of each Input Module can be configured to one of five possible Operating Modes:
-- Mode Ø: Discrete Fixed -- Mode 1: Momentary Triggered -- Mode 2: Binary Coded Decimal (BCD) -- Mode 3: Binary -- Mode 4: Counter · Power Module -- supplies power to the CPU Module / Input Modules

Figure 1

D

(see component descriptions on other side)

GN

YL

BR

WH

A

B

RD

BK

OR

BL

C CONNECTIONS TO NETWORK ADAPTER · Red (-) Differential: Connect to YL (Yellow Terminal) · Black (+) Differential: Connect to BK (Black Terminal) · Drain Wire (Shield): Connect to RD (Red Terminal)

SHLD + RS485 (Black) ­ RS485 (Red)

Module 1
E
SH. POS. NEG.
12

Side View
These modules are installed in a 12"x12"x4" deep box with a hinged door and cam lock to prevent unauthorized access. The inputs to the modules are pre-wired to terminal blocks for easy installation. A pair of wires from your dry contact(s) is all that is needed to activate the associated messages(s). The messages are pre-programed but can easily be changed with a hand-held remote or laptop computer.
4

firealarmresources.com

MNS LEDARRAY

INDOOR DISPLAY

SERIES

Operating Modes

NOTE: Only one Operating Mode can be used at a time. For example, if three Input Modules were connected together, all three modules would have to use the same Operating Mode.
Discrete Fixed (Mode Ø)
Description: When an input (IØ - I7) is high, the associated sign message is displayed. It is possible to have several messages running simultaneously on a sign.

Minimum configuration

Module configuration: (modules can be connected
in any order)

+ + + + + Power
Module

CPU Module

Input Module

Input Module

Input Module

Input Module

Input Module internal jumper settings:

AØ = Ø A1 = Ø A2 = Ø

AØ = 1 A1 = Ø A2 = 1

AØ = Ø A1 = 1 A2 = 1

AØ = 1 A1 = 1 A2 = 1

Maximum no. of messages: 32 Maximum no. of inputs: 32 (8 inputs per module x 4 Input Modules connected)

NON-ISOLATED

ISOLATED

24 VAC ~
OR
+18-36 VDC +

Power Module

~24

~24 24 VDC

24 VDC

NEG(ØV) NEG(ØV)

CPU Module

24 VAC ~
OR
+18-36 VDC +

Power Module ~24 ~24 24 VDC NEG(ØV)

Power Supply Module 2

CPU Module

Sinking (NPN) circuit:

Input Module Sinking (NPN)
24 VDC COM(ØV)
I7 I6 I5 I4 I3 I2 I1 IØ COM(ØV)

+18-36 VDC +

Input Module Sinking (NPN)
24 VDC COM(ØV)
I7 I6 I5 I4 I3 I2 I1 IØ COM(ØV)

CPU / Input Module 1

COM(ØV) is internally connected. 24 VDC is internally connected.

NOTE: All Input Modules are internally fused. Also, the Power Module is internally fused. NOTE: Wire the modules according to local electrical code.
5

firealarmresources.com

MNS LEDARRAY

SERIES

INDOOR DISPLAY

Connecting Using RS-485 Network
Networking one or more signs (shielded)

NOTE: When signs are networked to the CPU Module, all the signs must be the same model when ALPHA Messaging software is used.

BL

WH

OR

BR

BK

YL

RD

GN

SHLD + RS485 (Black) ­ RS485 (Red)

· Connect RED wire from RS485 cable to YL screw.
· Connect BLACK wire from RS485 cable to BK screw.
· Connect SHIELD wire from RS485 cable to RD screw if the sign is a
Series 4ØØØ or Series 7ØØØ. Otherwise, connect the two SHIELD wires to each other, but not to the RD screw.

RS485 cable

Mass Notification Signs Connecting using RS-485 Network.

See Figure 1 Page 4
L1 L2 PWR
DISPLAY SERIAL COM

(RS 232/485)

(RS 232)

1-foot RS485 cable or 8-foot RS485 cable

Modular Network Adapter

To next sign

Maximum = 4ØØØ feet (@ 96ØØ baud)

Enclosures

4" 1 7/8" Door

12"
MASS NOTIFICATION SYSTEM
SYSTEM CONTACT / SIGN NETWORK INTERFACE
12"

Backbox

MODEL G1212

POWER

SIDE VIEW

FRONT VIEW

MNS-CONTROLLER
6

4.5"

Use a twisted pair, 22awg with common shield. Use modular adapter for network wiring. Connect to sign with RJ-11 cable.
28.9"
LEDARRAY DISPLAY
SIGN IS 2.1" DEEP DISPLAY AREA IS 27"L x 2.1"H

firealarmresources.com



References