Instruction Manual for Supereyes models including: 10 Series, Television Microscope, 10 Series Television Microscope, Microscope
Купить цифровой видеомикроскоп Dagong XLB45-STL7 в Суперайс
File Info : application/pdf, 7 Pages, 780.45KB
DocumentDocumentTELEVISION MICROSCOPE 10 Series Operation Instruction Please read this operation instruction before you use microscope CATALOGUE Notes..................................Error! Bookmark not defined. Brief............................Error! Bookmark not defined. Usage ........................Error! Bookmark not defined. Structure ........................................................................ 4 Main Specificatons ..................................................... 4 install and operationError! Bookmark not defined. care and maintanceError! Bookmark not defined. form a complete set of instrumentError! Bookmark not defined. 1 Attention 1be sure not to disassemble Random to disassemble can easily lead the instrument brokenPlease do not random to disassemble any parts except this operation instruction mentioned can disassemble of parts.If find the instrument out-of-order,Please ask professional person to repair or direct to contact supplier. 2Inspect the voltage 1)Microscope base marked rated input voltage values.Pay attention to match the local service voltage.If the microscope use under un-nominal voltage,will be serious damage. 2)Power supply socket should earthing fine. 3.prevent burn and fire 1)during illumination,the bulb will be very hot.Be careful that do not touch your skin.to avoid burn. 2)change the bulb should after cooling 3)to avoid fire,inflammable do not close to bulb. 4change the bulb 1)to avoid electric shock and damage the instrument ,before change the bulb,should pull out the attaching plug. 2)only use specified halogen and fluorescence lamp tube. 3)should wear gloves or use protective jacket mantle the bulb,Your hand do not touch the glass of bulb. After changing the bulb,use the clean cloth to dip in straight alcohol,then wipe off the fingerprint and splodge that showed on bulb.Otherwise bulbs can be easily broken and reduce the lightness. 2 5carry and place 1)should turn off power switch before carry the microscope 2)working environment requirement: room tempreture:040 maximum relative humidity: 85% 3)when use the microscope should avoid under sunlight perpendicular incidence 4)avoid the microscope put on dust environment,If disuse,should coat on dust cover. 5)the microscope thould placed in no vibrative place. brief: 10 series of television microscope is a zoom stereo microscope,adopt unique achromatism and large depth of field technician,clear image ,strong stereoscopic impression and long working distance,wide of visual field and so on.Matching high definition of colours CCD and television.Designed with 0.5X,2X Series of additional objective and 0.35X,0.5X,1X Series of camera eyepiece.According user different situation requirement,specially designed many kinds of illuminator device.can according the observed sample choose up & down double halogen bulb;up halogen bulb,down fluorescence bulb.ring fluorescence lamp;fiber optic cold light source,LED coaxial illumination etc.Also can optional X.Y Moving stage,image analysis device to analyse the picture.Pillar stand base,boom stand base can option. 3 usage 10 series of microscope widely use for micro-electronicsmould power metallurgy precision machinery jewelry horologe decorations fingerprint identifyticket recognize the falseprintfiber opticmaintain the mobilearchaeology living beingsanatomyteaching etc.Especially for observe the surface microstructure of large objective.(many boom stand base can option) structurecheck below view: (1) stand base2focus arm3hand wheel4focusing hand wheel (5) pillar (6) pillar cover 7additional objectivecan optional(8)rotating sleeve(9)main objective10camera eyepiece11 CCDcameracan optional12colour televisiono or monitorcan optional13signal lineoptional 14CCDpower adaptercan optional main specifications 1.main optical parameter Television microscope magnificationworking distancedia of viewing field of object space;Effective for television image magnification.parts is :additional objective,main objective,camera eyepiece and CCD camera,television(display).Front 3 parts form optical magnifying glass,back 2 parts form digital magnification.The largest Optical magnification 30X,Total magnification is1776X13"CCD14"monitorlargest working distance 320mm,dia of viewing field of object space:90.7mm,As XDC-0745(ZOOM RATIO16.5) 0.7X-1.5X for example: a.total magnification=optical magnification×digital magnification 4 optical magnification=zoom main objective 0.7X 4.5X × Camera eyepiece magnification×additional objective(ref sheet 1) digital magnification:relative with CCD camera specification and television(monitor)specification.(ref sheet 2) b.wroking distance:only relative with objective and additional objective magnification.(ref sheet1) c.dia of viewing field object space=CCD camera diagonal size of target surface/optical magnification. Sheet 1 Additional objective 0.5X No additional eyepiece 2X Optical magnification Camera eyepiece 0.35X 0.5X 1X 0.120.19X 0.181.13X 0.352.25X 0.251.58X 0.352.25X 0.704.50X Working distancemm 180 95 0.493.15X 0.704.5X 1.409.00X 32 Sheet 2 CCDcamera specification 13" 12" 23" 14" 59.2X 44.5X 32.3X Digital magnification televisiondisplayspecification 15" 17" 21" 25" 63.5X 72.0X 88.5X 105.8X 47.6X 54.0X 66.7X 79.4X 34.6X 39.3X 48.5X 57.7X 29" 122.8X 92.1X 67.0X CCDcamera specification CCD camera diagonal size of target surface CCD camera diagonal size of target surface 13" 6mm 12" 8mm 23" 11mm 2.hand wheel focus range:65mm Drawtube size: 50mm,up to 25mm pillar centre distance 140mm 3.lift range25mm pillar: 178mmXDS-10A lift range:265mm 5 4illuminitioninput voltage110V60HZ or 220V50H outputoblique incidence illuminator 12V10W with halogen lamp. Transillumination:5W energy saving fluorescenct lamp(according user 6