Owner's Manual for Thermador models including: MD24BS, MD24BS, MD24BS 24 Inch Microdrawer Microwave, MD24BS Microdrawer Microwave, 24 Inch Microdrawer Microwave, Microdrawer Microwave, Microdrawer, Microwave

Thermador Masterpiece & Professional Series MicroDrawer Microwave 24-Inch in Stainless Steel Specification Sheet

Thermador MD24BS MD24BS 825225972396

MD24BS

30 giu 2024 — GENERAL PROPERTIES. Cavity Color. White. Microwave Power. 950 W. CAPACITY. Cavity Capacity. 1.2 cu. ft. TECHNICAL DETAILS. Watts. 1,500 W. Circuit Breaker.


File Info : application/pdf, 3 Pages, 1.09MB

PDF preview unavailable. Download the PDF instead.

thermador-microdrawer-MD24BS-specs
MD24BS
24-INCH MICRODRAWER® MICROWAVE
MASTERPIECE® & PROFESSIONAL COLLECTION


FEATURES & BENEFITS
- Easy touch to automatic "open" and "close" enables handsfree operations
- Concealed drop-down panel effortlessly opens to a convenient 60° angle for easy readability and operation
- Connect to your MicroDrawer® for remote monitoring with ability to open drawer and access recipes via the Home Connect® app
- Spacious and easy to clean enameled cavity with 1.2 cu. ft. interior fits a 20 oz. cup or a 13" x 9" pan
- Achieve a perfectly flush installation in any standard depth cabinetry
- Sensor Cooking is designed to effortlessly manage humidity levels, automatically adjusting cooking time and intensity for optimal results every time
- 10 versatile Microwave Programs, including melt, warm, and soften to accomplish culinary tasks of all sizes with ease

GENERAL PROPERTIES Cavity Color Microwave Power C A PA C I T Y Cavity Capacity TECHNICAL DETAILS Watts Circuit Breaker Volts Frequency Plug Type Power Cord Length DIMENSIONS & WEIGHT Overall Appliance Dimensions (HxWxD)
Required Cutout Size (HxWxD) ­ Standard Install Required Cutout Size (HxWxD) ­ Flush Install Net Weight WARRANTY Limited Warranty, Entire Appliance, Parts and Labor

White 950 W
1.2 cu. ft.
1,500 W 15 A 120 V 60 Hz 120V-3 Prong 48"
16 5/16" x 23 7/8" x 23 3/8" 15 9/16" x 22 1/8" x 23 1/2" 16 5/8" x 24 3/16" x 23 1/2" 74 lbs.
2 Year

To be fully ADA compliant, these units must be installed according to ADA guidelines. Please check current ADA requirements for guidance on installation. Page 1 of 3

6 / 24

MD24BS
24-INCH MICRODRAWER® MICROWAVE
MASTERPIECE® & PROFESSIONAL COLLECTION

PRODUCT DIMENSIONS

Measurements in inches (mm)

48 (1220)

215/8 (550)

145/8 (371)

237/8 (606)
A

233/8 (594)

217/8 (556)

383/8 (974)

111/16 (39)
165/16 (414)

A 113/16 (46)

Page 2 of 3

6 / 24

MD24BS
24-INCH MICRODRAWER® MICROWAVE
MASTERPIECE® & PROFESSIONAL COLLECTION

 ( 22) (

 ( 22) (

STANDARD INSTALLATION

4 (102) (A)

36 (914)

145/8 (372)

231/2 (597)

(B) 6 (152) 31/2 (89) 11/2 (38)

(D)  7/8 ( 22) (E)

 7/8 ( 22) (E)

5 (127) (C)

3/4 (19) (E)

/1 16

(2)

(E)

221/8 (562)

 13 ( 336)
159/16 (395)

1/2 (13) (F)

 131/4 ( 336)
24 / 27 (610 / 686)

A: Recommended location of electrical outlet
B: Anti-tip block C: Base should support up to 100 lb
D: Front view of cut-out E: Overlap F: Visible area
If under a counter, minimum clearance to counter top should be 7/16" (11 mm)
Measurements in inches (mm)

FLUSH INSTALLATION

4 (102)

(A)

36 (914)

145/8 (372)

 217/8 231/2 ( 555) (597) (D)
15/8 (41)

(B) 6 (152) 21/4 (57) 21/4 (57)

(E) 1 (25) (F)

1 (25) (F)

5 (127) (C)
 131/4 ( 336)

1/4 (6) (G)

 21 221/8 ( 55(55)62)

1/2 (13) (H)
165/8 (422)
 13 ( 336)

243/16 (614)

A: Recommended location of electrical outlet

 13 ( 336)

27 (686)

B: Anti-tip block C: Base should support up to 100 lb D: Base depth E: Front view of cut-out F: Sides should be finished and extend back to cleat

Cleats should also be finished, as they may be visible after installation

G: Base thickness H: Visible area

If under a counter, minimum clearance to counter top should be 7/16" (11 mm) Measurements in inches (mm)

 ( 2  13 ( 336)

These warranties give you specific legal rights and you may have other rights that vary from state to state. Limited warranty from date of delivery. For complete warranty details, refer to your Use & Care manual, or ask your dealer.
Specifications are for planning purposes only. Refer to installation instructions and consult your countertop supplier prior to making counter opening. Consult with a heating and ventilation engineer for your specific ventilation requirements. For the most detailed information, refer to installation instructions accompanying product or write to Thermador indicating the model number. Specifications are correct at time of printing. Thermador reserves the right to change product specifications or design without notice. Some models are certified for use in Canada. Thermador is not responsible for products that are transported from the U.S. for use in Canada.
1 800 735 4328 | USA THERMADOR.COM | CANADA THERMADOR.CA | ©2024 BSH HOME APPLIANCES CORPORATION. ALL RIGHTS RESERVED.

Page 3 of 3

 21

6 / 24



References

Adobe PDF Library 17.0 Adobe InDesign 19.4 (Macintosh)