DEHUMIDIFIER DRY CLOUD 11-13

Model: DRY CLOUD 11-13

Brand: Argo

Document Type: Operating Instructions

OPERATING INSTRUCTIONS

Read the instructions carefully before operating or servicing the dehumidifier. Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage. Keep these instructions in a safe place for future reference.

Safety Information & Refrigerant Details

⚠️ [Flammable Gas] Appliance is filled with flammable gas R290.

? [Read Manual] Before installing and using the appliance, read the owner manual.

? [Read Manual] Before installing the appliance, read the installation manual.

? [Service Manual] Any repairs you need, contact the nearest authorized Service Centre and strictly follow manufacturer's Service Manual.

The Refrigerant R290

Warning:

Do not try to accelerate the defrosting process or to clean the appliance in different ways other than those recommended by the manufacturer. Should repair be necessary, contact your nearest authorized Service Centre. Any repairs carried out by unqualified personnel may be dangerous. The appliance has to be stored in a room that doesn't have any continuously operating ignition sources. (for example: open flames, an operating gas appliance or an operating electric heater.) Do not pierce or burn. Appliance has to be installed, used and stored in a room with a floor area larger than 14 m².

GENERAL OPERATING AND SAFETY INSTRUCTIONS

Safety Precautions

WARNING!

In the event of an anomaly, switch the appliance off and unplug it immediately. Do not dismantle, repair or modify this product freely. In the event of a malfunction, contact the after-sales service centre directly.

DESCRIPTION OF PARTS

FRONT VIEW:

REAR VIEW:

Operating Space Requirement:

The following space must be maintained to ensure the operating efficiency of the dehumidifier: at least 50 cm away from walls or other obstructions.

Diagram illustrating the required clearance around the dehumidifier: at least 50 cm from walls and other obstructions to ensure proper heat dissipation and operating efficiency.

PRE-OPERATING CHECKS AND OPERATIONS

Before using the appliance, make sure the condensate collection tank is correctly positioned.

  1. Remove the tank following the direction of the arrow.
  2. Remove from the tank the bubble plastic bag which contains the 4 wheels and the cable reel.
  3. Reposition the tank, closing it perfectly.
  4. Tilt the dehumidifier no more than 45° and remove the 4 rubber plugs, which will be replaced by 4 wheels that are inside the tank.
  5. Position the wheels on the 4 holes and push until the wheels are set firmly in place.

OPERATING INSTRUCTIONS

APPLIANCE START-UP

Place the product on a flat and stable heat-resistant surface, at least 1 metre away from flammable or heat-sensitive materials and 50 cm away from walls or other obstructions.

Make sure the water tank is in the correct position.

Connect the power cord to a suitable electric socket (220-240V/50Hz).

Turn the appliance on with ON/OFF on the control panel. The unit emits a "beep" signal ? and the corresponding LED lights up.

The dehumidifier is designed to operate at ambient temperatures from +5°C to +32°C.

If it is operated at low temperatures, ice may form on the evaporator, degrading its operation. When this happens, the dehumidifier goes into defrost mode. The compressor stops, but the fan continues running. The defrosting operation may start up and operate for some minutes; during the defrosting operation, the dehumidification function may intermit: please don't turn off the switch or pull out the power plug of the dehumidifier.

We recommend not using the dehumidifier in room temperatures lower than 5°C.

Do not remove the tank when the unit is in operation.

If you wish to make continuous draining of condensate, follow the instructions in the dedicated paragraph.

OPERATING PRECAUTIONS

The dehumidifier starts only if the humidity level in the room is higher than the set one. The dehumidifier will continue to operate until the set humidity level is reached, except for any interruptions due to filling the tank.

When the water tank is full, the compressor stops running immediately and dehumidification stops; the fan stops after 3 minutes. Empty the tank and reposition it: after carrying out these operations, the unit will start operating again.

After the machine has reached the set humidity ≤-5% RH of the set humidity, the compressor stops immediately while the fan stops after 9 minutes.

When the humidity in the room is greater than or equal to the humidity set + 5% RH, the machine will start working again.

WARNING: When the dehumidifier is running, the compressor produces heat and the appliance emits warm air into the room. The room temperature will therefore tend to increase. This is completely normal.

TURNING THE DEHUMIDIFIER OFF

To turn the dehumidifier off press the ON/OFF button. This shuts off power to the unit. Unplug the appliance if you do not intend to use it for some time.

HOW TO ELIMINATE CONDENSATE

The water extracted from the air can be collected in the provided front tank. When the tank is full, not inserted or not correctly inserted, the FULL TANK LED turns on and the unit beeps ? for about 10 seconds, at the end of which the unit turns off.

To switch off the appliance, press the ON/OFF button and wait a few seconds.

  1. Carefully remove the tank and following the direction of the arrow.
  2. Empty the tank.
  3. Reposition the tank following the direction of the arrow.
Diagram showing the condensate collection tank being removed from the dehumidifier, with an arrow indicating the direction of removal.

N.B. Do not use the drain hose when you are collecting condensation in the tank, otherwise water can leak out of the hose.

CONTINUOUS CONDENSATE DRAINAGE

The water can be continuously drained when using a PVC hose with an inner diameter of 14 mm (not supplied). Turn off the appliance and remove the plug before connecting the hose.

Diagrams illustrating correct and incorrect methods for connecting the continuous drainage hose. Correct connection shows the hose fitted securely to the discharge port. Incorrect connections show potential issues like blockage or improper fit.

CONTROL PANEL

Diagram of the dehumidifier's control panel, indicating the positions of various LEDs (Filter Clean, Timer, Humidity, Fan Speed, Full Tank) and buttons (Filter, Timer, Humidity, Fan Speed, Power).

Each time the button is pressed, the unit emits an auditory signal ?.

BUTTONS & LEDS

  1. POWER BUTTON: press this button to turn the dehumidifier on and off.
  2. FAN SPEED BUTTON: press this button to adjust the ventilation speed (Low, High).
  3. HUMIDITY BUTTON: press this button to adjust the % of humidity to desired value (30-80%) – each step 5%.
  4. ON/OFF TIMER BUTTON: Delayed on/off button. Allows planning the on (if the unit is off) or the off (1-24 h).
  5. FILTER BUTTON: After 250 hours of operation, the FILTER RESET LED turns on to indicate that it is time to clean the filter. Take the filter out and clean it. Then press the FILTER button.
  6. DISPLAY: shows the relative humidity setting.
  7. LED Filter: filter needs to be cleaned.
  8. LED HIGH AND LOW FAN SPEED: shows the set fan speed: High and Low.
  9. LED TIMER: shows that the timer is set.

LED Full: When the tank is full or it's not correctly positioned the LED Full comes on and the appliance stops running. A 10 second beep ? sounds. Remove the tank and empty it (as indicated in "HOW TO ELIMINATE CONDENSATION"), then restore it; the dehumidifier will start running again.

DEFROST: the dehumidifier is designed to operate at ambient temperatures from +5°C to +32°C. If it is operated at low temperatures, ice may form on the evaporator, degrading its operation. When this happens, the dehumidifier goes into defrost mode. The compressor stops, but the fan continues running. We recommend not using the dehumidifier in room temperatures lower than 5°C.

MEMORY FUNCTION: the dehumidifier starts up again after a power failure keeping last settings.

AUTOSTOP FUNCTION: if the humidity is lower than 5% respect to the one set by the humidifier, it automatically stops.

CLEANING AND MAINTENANCE

MAINTENANCE OF THE HUMIDIFIER'S EXTERIOR SURFACE

Warning: Always pull the dehumidifier's plug out of the power socket before cleaning it, to prevent electric shock and malfunction.

Warning: Do not wet the appliance or immerse it in water, otherwise electric shocks may occur.

Use a damp and soft cloth to clean the exterior surface of the dehumidifier. Do not use solvents, petrol, xylene, talcum powder or brushes to clean the unit: these may damage the surface or colour of the casing.

Diagram showing a hand wiping the exterior of the dehumidifier with a cloth.

CLEANING THE WATER TANK

We advise removing the tank once every few weeks to prevent mould and bacteria forming on it. Fill the tank with clean water and a small amount of detergent; swill the water around in it, then empty it out and rinse it thoroughly.

CLEANING THE AIR FILTER

The filter is designed to remove dust or dirt from the air. If the filter is clogged by dust, electricity consumption will be higher than normal.

Cleaning instructions:

  1. Remove the filter by simultaneously pressing "push" on the top left and right of the filter with 2 hands. Clean the filter by washing it with warm soapy water. DO NOT USE ALCOHOL, BENZENE OR OTHER AGGRESSIVE PRODUCTS TO CLEAN THE FILTER. Leave the filter to dry naturally, then reposition it in its slot. Do not use a hair dryer or fire to dry the filter. Do not use sponges or brushes to clean the filter because they can damage it.
  2. Reinsert the filter.

Do not use the dehumidifier without the filter as dust may affect the efficiency of the evaporator, resulting in higher energy consumption.

Diagrams showing the air filter removal and reinsertion process. The air filter is located at the top rear of the unit.

TROUBLESHOOTING

PROBLEM POTENTIAL CAUSE SOLUTION
The dehumidifier is not working. It is not possible to adjust the settings. The temperature is above 32°C or below 5°C.
The internal tank is full.
The tank is not positioned correctly.
The power plug is not inserted correctly.
Empty the tank.
Position the tank correctly.
Correctly connect the plug.
The noise suddenly increases while running. The compressor has just started.
There is a power connection problem.
The unit is placed on an uneven surface.
Position the unit on an even and stable surface.
Reduced dehumidification effect. The room temperature is too low.
The set humidity level is inadequate.
The filter is full of dust.
The doors and windows are open.
Reduce the humidity level.
Clean the filter.
Close any doors and windows.
Remove objects that obstruct the inflow and outflow of air.
At first, the air might have a musty smell. Due to the temperature difference of the heat exchanger, the air might have a strange smell at first. (No specific solution provided, implied to be normal).
There is water in the tank even when using the hose for continuous condensation drainage. Check the drainage connections.
The drainage hose is not connected properly.
Connect the hose correctly.
Remove the drainage hose and replace it.
The ON/OFF LED does not turn on when the power is connected. There is no power or the plug is not inserted correctly. Check the electrical power supply. Make sure that the electric circuit and plug are not damaged. Make sure that the cable is not damaged.
The dehumidifier stops working during dehumidifying process. Whether the room temperature is too high or too low and out of the working scope of the dehumidifier. The dehumidifier may start automatically when the room temperature returns to the working scope.
The humidity of the room can't reduce. The room area is too big, which is over its application scope.
The door and windows of the room aren't closed.
The machine unit is operated with a kerosene heater which releases steam.
(No specific solution provided, implies environmental factors).
There is water in the tank. Since each machine unit has taken operation test before leaving the factory, some water remains on the evaporator flows to the water tank. (No specific solution provided, implies normal residual water).
The FULL indicator LED is on. When the water tank is full, the FULL indicator led is on for reminding. Empty the tank.

REGULATION (EU) N. 517/2014 - F-GAS

DRY CLOUD 11/13

The unit contains R290, a natural greenhouse gas with global warming potential (GWP) = 3.

DRY CLOUD 11: Kg. 0,045 = 0,000135 Tonn CO² equiv.

DRY CLOUD 13: Kg. 0,055 = 0,000165 Tonn CO² equiv.

Do not release R290 into the atmosphere.

INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN DIRECTIVE 2012/19/EU

This appliance may not be scrapped with domestic waste at the end of its life cycle. We call your attention to the crucial role played by the consumer in the re-use, recycling and other forms of recovery of such waste.

The appliance must be scrapped by a sorted waste disposal centre or by returning it to the retailer (no charge is levied for this service), when you purchase a new equivalent appliance.

Sorted disposal of electric and electronic equipment prevents the negative effects on the environment and human health resulting from improper scrapping, and also allows the materials from which it is made to be recovered and recycled, with significant savings in terms of energy and resources.

The sorted disposal requirement is indicated by the crossed waste bin label affixed to the appliance. ?️ [Crossed Bin Symbol]

For more information, visit www.argoclima.com.

Models: B08668CY96 Dry Cloud 13 Dehumidifier, B08668CY96, Dry Cloud 13 Dehumidifier

File Info : application/pdf, 11 Pages, 1.17MB

PDF preview unavailable. Download the PDF instead.

DRY-CLOUD-11-13 en rev01-2

References

Acrobat Distiller 21.0 (Windows)

Related Documents

Preview Argo DRY PURY Dehumidifier Operating Instructions and Safety Manual
Official operating instructions and safety guide for Argo DRY PURY dehumidifiers (models 11, 13, 17, 21, 25). Covers setup, operation, maintenance, troubleshooting, and R290 refrigerant safety.
Preview Manual de Usuario Argo Dry Pury Evo 11-13: Instrucciones y Mantenimiento
Guía completa para el deshumidificador Argo Dry Pury Evo. Aprenda sobre su funcionamiento seguro, controles, mantenimiento y solución de problemas con el refrigerante R290.
Preview Argo Dry Nature Dehumidifier: Operating Instructions and Safety Guide
Comprehensive guide to operating, maintaining, and troubleshooting the Argo Dry Nature dehumidifier. Includes safety precautions, parts description, control panel functions, and regulatory information.
Preview Argo 2023: Climatizzatori, Ventilatori e Deumidificatori - Catalogo Prodotti
Scopri la gamma 2023 di Argo per il comfort domestico e professionale: climatizzatori, ventilatori, deumidificatori e raffrescatori con tecnologie avanzate e design italiano. Soluzioni per ogni esigenza.
Preview Argo Catalogo 2024: Climatizzatori, Ventilatori e Deumidificatori
Scopri la gamma 2024 di Argo per il comfort domestico e professionale. Climatizzatori, ventilatori, deumidificatori e raffrescatori con tecnologie innovative per migliorare la tua vita. Prodotti efficienti e di design.
Preview Argo 2023 Primavera/Estate: Climatizzatori, Ventilatori, Raffrescatori e Deumidificatori
Esplora la collezione 2023 Primavera/Estate di Argo, che include climatizzatori monosplit e multisplit, ventilatori da tavolo, a piantana, smart fan, raffrescatori evaporativi e deumidificatori per un comfort ottimale in ogni ambiente.
Preview Argo Spring/Summer 2024 Collection: Air Conditioners and Dehumidifiers
Explore the Argo Spring/Summer 2024 collection featuring advanced single-split air conditioners, local air conditioners, and dehumidifiers. Discover innovative features, energy efficiency, and modern design.
Preview Argo Esclusive: Spring | Summer Collection 2022 - Air Conditioners & Dehumidifiers
Explore the Argo Esclusive collection for Spring/Summer 2022, featuring high-performance single/multisplit air conditioners (Greenstyle Plus series), portable local air conditioners (Egon EU, Ares EU WF, Maxime Plus EU), and efficient dehumidifiers (Dry Cube). Discover advanced features, technical specifications, and energy efficiency ratings.