User Guide for femometer models including: FM-VC-201 Basal Thermometer, FM-VC-201, Basal Thermometer, Thermometer

说明书

User Manual

JOYTECH HEALTHCARE CO., LTD. 0052 2AQVU0052 2AQVU0052 0052


File Info : application/pdf, 2 Pages, 2.58MB

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=7762910
NN

NN H

NN

NN

Basal Thermometer
FM-VC-201

EN 1. INTENDED USE
2. HOW TO USE 1 Download App
Search "Femometer" on Apple Store or Google Play to download.

2 Pair Thermeter with Your Smartphone

Step 1: Remove the cap from Femometer.

Step 2: Turn on your phone's Bluetooth.

Step 3: Follow the prompts on your phone.

3 Take Your Temperature

Step 1: Set a reminder on your phone to wake up and take your temperature each morning.

Step 2: Upon waking, remove thermometer from its case, place it under your tongue and hold it there for 1-3 minutes, until you hear 3 beeps, indicating temperature has been taken.

Step 3: Open the application, the data will be transmitted automatically.

4 Replace the Battery
Step1: Insert the stainless steel tool into the crevice at the base of thermometer, gently pry open the battery tray.

Step2: Wait for one minute,put a CR2032 battery in the battery tray with "+"facing down.

Step3: Close the tray from the base of the thermometer. Remove the battery when not in use for a long time.

5 Upload Data to the App
Once your temperature has been taken, your phone's Bluetooth must be on, the data can be transmitted from the thermometer to your phone.
If the data does not sync, remove the cap from the thermometer, and tap the scale ring in the Femometer App to transmit the data.
3. ALERTS & SOUNDS
- When you remove the thermometer from the case, a single beep indicates that it is on. - When you close the case, a single beep indicates that the thermometer is off. - When taking your temperature3 consecutive beeps indicate that the measurement is complete. - A beep lasting longer than 2 seconds indicates an error. Please close the case and reopen the thermometer until the measurement is complete.

Symptoms

Possible reasons
While measuring, the temperature is lower than 32.00¥c89.60

While measuring, the temperature is higher than 42.00¥c107.60
Hardware failure

Lit up and flashing

Solutions

If the device keeps showing

during

measurement, please put the cover back, wait

for one minute and measure again.

Put the cover back, wait for one minute and measure again.
Remve the battery and wait for one minute. Put the battery back. If the message comes up again, please contact the retailer for solutions.

Please change the battery(CR2032).

Symptoms

Mode Fast Mode Normal Mode
Mercury Mode

Description Duration: approximately 30 seconds Advantage: fastest Suitable for: users with good temperature measuring habits
Duration: 1 - 1.5 minutes Advantage: optimal balance between stability and speed Suitable for: Femometer newbies
Duration: 3 minutes Advantage: safest Suitable for: users who want to follow NFP rule exactly to avoid pregnancy

5. TROUBLESHOOTING

Symptoms

Possible resons

Solutions

I never heard the end tone while the thermometer is under my tongue.
The data did not sync to the App after my measurement.
There is no sound when opening the thermometer.

Thermometer is off.
Measurement time is too short. Button battery has run out. The Bluetooth is not open. The phone is too far to sync.
Button battery has run out or the thermometer is broken.

Close the cover and reopen it to restart the thermometer. Keep measuring for 1-3 minutes.
Replace the button battery.
Open the Bluetooth on the phone.
Put the phone close to the thermometer.
Replace the button battery and if the thermometer still makes no sound, the thermometer is broken.

6. PRODUCT MAINTENANCE & CARE
1. Battery care
- Replace the battery when instructed via notification in the Femometer app. - Always dispose of used batteries according to local laws and regulations.
2. Cleaning & Disinfection - Clean the tip of the thermometer with a solution of 75% rubbing alcohol and 25% water before and after every use. - Do not use cleaning agents other than alcohol and water to clean the device as it may damage or decrease the lifetime of the product and/or present safety risks. - Never submerge the device in water ­ this can damage the device and result in erroneous data.

7. TECHINCAL SPECIFICATIONS

Product name Vinca II
Model FM-VC-201
Size 120.2mm*24.4mm*16.4mm
Weight 24.8g(without battery)
Ingress protection rating IP 22 Transmission distance Up to 16 feet

Measurement 89.6ºF-107.6ºF
Accuracy ±0.09ºF(95.0ºF-100.4ºF) ±0.18ºF(89.6ºF-95ºF) & (100.4ºF -107.6ºF)
Battery CR2032
Battery endurance 3-6 months
Expercted service life Three years

Operating conditions Temperature: 41ºF-104ºF Humidity: 85% Atmospheric pressure:70Kpa-106Kpa
Storage conditions Temperature:-40ºF-131ºF Humidity:93% Atmospheric pressure: 70Kpa-106Kpa
Contraindications None
Classification Type BF

8. PRODUCT FUNCTIONS & FEATURES
1. Basal body temperature measurement & Bluetooth - Thermometer measures basal body temperature to 1% degrees Farenheit accuracy. Your basal body temperature is automatically uploaded to your phone via Bluetooth, which is fast and energy - efficient, and represented via temperature Charts and graphs to track and make predictions about your menstrualcycle.
2. Data stored in the cloud - All your data is stored in the cloud, so you don't have to worry about manually uploading or losing your information. You can also sync thermometer to different devices.
3. Share date with friends - Share your data easily with your partner or doctor from the Femometer App via E-mail.

4. ABOUT THE DISPLAY

1. Remove the upper cover of the thermometer.

will be shown on the screen.

Measurement will start when the LED backlight is on and you hear a beep.

2. To extend the battery life, the screen will be off once"

"is displayed 2 seconds after the measurement.

9. SAFETY STATEMENT
1. The EMC of the product is up To standard of IEC60601-1-2. 2. The material that contacts Skin is nontoxic, nonirritating And up to standard of IS010993-1,-5,-10.
10. DISCLAIMER
- This manual is written in accordance with available information and contents are subject to change without notice. Bangtang has made the best effort to guarantee the manual's accuracy and reliability. However, the company does not assume liability for loss or damage caused by omissions, inaccuracies or typographical errors in this manual. - If there are discrepancies in this manual due to software upgrades, instructions and function dictated by the software should prevail. If improvements are made to the product or the product technology changes, please visit Bangtang's technical support website for further information. - All symbols and logos associated with Bluetooth, including the Bluetooth word mark, figure mark, combination mark and Bluetooth Smart and Bluetooth ready marks, are all trademarks owned by the Bluetooth SIG. Any use of such marks by Bangtang is under license. Other trademarks and trade names used belong to their respective owners.
11. CALIBRATION
The thermometer is initially calibrated at the time of manufacture. If the thermometer is used according to the use instruction, periodic readjustment is not required. However, we recommend checking calibration every two years or whenever clinical accuracy of the thermometer is in question. Turn on the thermometer and insert into the water bath and then check the laboratory accuracy. Please send the complete device to the dealers or manufacturer. ASTMlaboratory accuracy requirements in the display ±0.09c95.0 - 100.4±0.18c89.6-95.0&c100.4-107.6. The above recommendations do not supersede the legal requirements. The user must always comply with legal requirements for the control of the measurement, functionality, and accuracy of the device which are required by the scope of relevant laws, directives or dinances where the device is used.
12. WARNING
* Read instructions thoroughly before using digital thermometer. * Choking Hazard: Thermometer cap and battery may be fatal if swallowed. Do not allow children to use this device without papental supervision. * Do not place thermometer batery near extreme heat as it may explode. * Remove battery from the device when not in operation for a long time. * The use of temperature readings for self-diagnosis is dangerous. Consult your doctor for the interpretation of results. Self-diagnosis may lead to the worsening of existing disease conditions. * Do not attempt to disaddemble or repair the thermometer. Doing so may result in inaccurate readings. * For children who are two years old or younger, please do not use the devices orally.
*The performance of the device may be degraded should one or more of the following occur - Operation outside the manufacturer's stated temperature and humidity range. - Storage outside the manufacturer's stated temperature and humidity range. - Mechanical shock(for example,drop test) or degraded sensor. - Patient temperature is below ambient tenperature. *Portable and mobile RF communications can affect the device.
FCC REQUIREMENT
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ­ Reorient or relocate the receiving antenna. ­ Increase the separation between the equipment and receiver. ­ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ­ Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
13. COPYRIGHT STATEMENT
- Lollipop Technology (Hangzhou) reserves ail rights, and retails the final right to interpret and revise this handbook and the statements contained therein. Copyright of this manual belongs to Lollipop Technology (Hangzhou) Co., Ltd. Without prior written permission, no company or individual is allowed to reproduce, copy or translate this many or any information contained therein.
Manufacturer: JOYTECH Healthcare Co., Ltd. No.365, Wuzhou Road, 311100 Hangzhou, Zhejiang Province, PEOPLE'S REPUBLIC OF CHINA Telephone: +86-571-81957767 Fax: +86-571-81957750
Made in China
14. WARRANTY
- This product is warranted from manufacturing defects for one year from the date of retail purchase. It does not cover damages or wear resulting from accident, misuse, abuse, commercial use or unauthorized adjustment and repair of product. Please direct all returns to the place of original purchase and retain your original receipt, as you may be asked to provide a copy fix proof of purchase. To find the customer service menu, please contact us:support@femometer.com

NN

NN
15. SYMBOL KEY
BF
Question? E-mail: support@femometer.com
16. PURCHASING RECORD
Model Prchased/Gekauftes Model: FM-VC-201 Name: Serial Number/Seriennummer: Phone Number/Telefonnummer: Data of Purchase/Datum des Kaufs: E-Mail Address/E-Mail Adresse:

2021.3

NN H

NN

Disposal of this product and used batteries should be carried out in accordance with the national regulations forthe disposal of electronic products.
Made in China

Shanghai International Holding Corp. GmbH (Europe) Eiffestrasse 80,20537 Hamburg, Germany
Document No. BM-202103-001 Article No.: 001 Version: A Date of Issue: 2021.03

0197


Adobe PDF library 15.00 Adobe Illustrator 24.0 (Windows)