L20-TWDM1B-1400 REV A.1
TAU-MC-01-BL
Hyfire Taurus Multi-Sensor Detector Black
GENERAL DESCRIPTION The TAU-MC-01-BL Taurus series detector samples the air and the environmental temperature in the protected area; when the environmental smoke quantity, the temperature level or the thermal variation rate exceeds a certain degree, a fire alarm message is sent to the control panel. TAU-MC-01-BL is battery powered and doesn't need any system cabling installation.
9

1

1

3 42

6

5 7 8

1) LED indicators
2) Battery A 3) Battery B
4) Link program switch 5) Tamper spring (internal)
6) Tamper switch (external) 7) Battery cover 8) Battery cover latch
9) Insulating tab 10) Wall fixing openings
11) Identification tag 12) Identification tag lodgement 13) Magnet test area
14) Base / detector reference marks 15) Safety screw

11 12

10

10

15 13

14

Picture 1 All pictures are for product in black variant. Shown white for illustrative purpose only

DEPLOYMENT PROCEDURE

1) Select a location for the detector. See LOCATION SELECTION.

2) Unbox the detector from its packaging.

3) Detach the detector from its base. See INSTALLING / REMOVING THE DETECTOR. 4) Detach the battery cover from the detector. See BATTERY COVER. 5.1) a) Link the detector to the system (insulating tab extraction).
See LINKING - WAKE-UP - WITH INSULATING TAB. See LINKING - ONE-BY-ONE - WITH INSULATING TAB.
-- or -5.2) a) Power up the detector.

Dust covers DO NOT provide

complete protection against

contamination:

detectors

should be removed before construc-

tion, major re-decoration or other dust

producing work is started.

See POWERING UP - FIRST TIME USE - WITHOUT INSULATING TAB. See POWERING UP - RECOVERY. b) Link the detector to the system (moving the link program switch).

Dust covers MUST be removed before the system can be made operational.

See LINKING - WAKE-UP - WITHOUT INSULATING TAB.

See LINKING - ONE-BY-ONE - WITHOUT INSULATING TAB.

6) Reinstall the battery cover on the detector. See BATTERY COVER.

7) Detach the identification tag from the base adapter. See IDENTIFYING THE DETECTOR.

8) Install the base adapter. See FIXING THE ADAPTOR BASE.

9) Install the detector on the base adapter. See INSTALLING / REMOVING THE DETECTOR.

10) Install the identification tag to the base adapter, with all relevant information written / labelled on it. See IDENTIFYING THE DETECTOR.

11) Secure the detector to its base with its safety anti-tamper screw. See INSTALLING THE SAFETY SCREW.

12) Test the detector. See TESTING.

LOCATION SELECTION
Select a location for the detector that conforms to your local applicable safety standards and that is in a good position for sending / receiving wireless signals to / from the father TAU-TRM-01, TAU-CEM-01 or TAU-EXM-01 network device.
Mount the detector as far as possible from metal objects, metal doors, metal window openings, etc. as well as cable conductors, cables (especially from computers), otherwise the operating distance may greatly drop.
The TAU-MC-01-BL must NOT be installed near electronic devices and computer equipment that can interfere with its wireless communication quality.
It is advisable to use the TAU-STK-01 survey kit to locate a good wireless installation location.

Hyfire Wireless Fire Solutions Ltd - Unit B12a, Holly Farm Business Park, Honiley, Warwickshire, CV8 1NP - United Kingdom

www.hyfirewireless.com 1

BATTERY COVER
Detach the battery cover by pulling and lifting the closing latch. To reinstall the battery cover, insert its two hooks into their corresponding detector's recesses; then block it by pressing down the opposite side, until you hear the click of the closing latch.
INSTALLING / REMOVING THE DETECTOR

Always install the battery cover, since it is a vital part of the tamper detection feature. Make sure the battery cover is safely fixed, blocked and closed. Make sure that the internal tamper spring fits completely into its battery cover's lodgement. Check, more than once, that the cover's external tamper switch clicks when pressed.

Rotate the detector clockwise on its adaptor base to install it. Rotate the detector anti-clockwise from its adaptor base to remove it.
IDENTIFYING THE DETECTOR

Check the alignment of the raised reference marks on the detector and on the base.

The detector can be visually identified by the detachable tag imprinted with the adaptor base. 1) Detach the tag from the base.
2) Write / label the relevant identification information on the tag. 3) Insert the tag into its lodgement on the side of the adaptor base.

FIXING THE ADAPTOR BASE

Fix the base to the wall with suitable screws. INSTALLING THE SAFETY SCREW

Always install the safety blocking screw.

Always install the safety blocking screw. LED INDICATORS STATUS MESSAGES

Please mind that LED signalling burns out battery power, therefore reducing batteries lifespan.

The two LED indicators communicate to the final user the status of the TAU-MC-01-BL.

Device status Power up (DIP on "ON") Power up (DIP opposite "ON") Entering wake-up mode Link success (one-by-one) Link failure (one-by-one) Link success (wake-up) Link failure (wake-up) Normal condition Alarm activation Battery fault Tamper fault Replaced Test mode active

LEDs indication Blinks red 4 times Blinks green 4 times Blinks alternatively green / red 4 times Blinks green 4 times, then the same pattern again Enters wake-up mode and signals "Entering wake-up mode" following this failure Blinks green 4 times, then same pattern again Blinks green 4 times, then blinks red on once, then blinks alternatively green / red 4 times LED off (can be programmed so as to blink green every wireless communication) Blinks red every 2 seconds LED off (can be programmed so as to blink amber every 5 seconds) LED off Blinks amber 2 times Blinks green

POWERING UP AND LINKING - PRELIMINARY NOTES

Table 1

TAU-MC-01-BL needs to be powered up with the supplied batteries. Linking is the operation through which TAU-MC-01-BL is "wirelessly connected" to a TAU-TRM-01, TAU-CEM-01 or TAU-EXM-01 Taurus network device.

LINKING - WAKE-UP - WITH INSULATING TAB

"Wake-up" linking consists in associating one or more child devices to the Taurus system altogether in a single operation. Wake-up is performed either through the TauREX software or the TAU-TRM-01 / TAU-CEM-01 keyboard-screen interface; it CANNOT be done through TAU-EXM-01 devices. 1) Create the "virtual model" of the TAU-MC-01-BL either on TauREX or on the TAU-TRM-01 / TAU-CEM-01. 2) Pull out the insulating tab.
3) Trigger the wake-up procedure either from TauREX or from the TAU-TRM-01 / TAU-CEM-01. 4) Wait the end of the "wake-up" linking procedure.
5) Check on TauREX or from TAU-TRM-01 / TAU-CEM-01 for linking success. Consult their user manual.

LINKING - ONE-BY-ONE - WITH INSULATING TAB

"One-by-one" linking consists in associating one child device at a time to the Taurus system.

This operation is performed either through the TauREX software or the TAU-TRM-01 / TAU-CEM-01 keyboard-screen interface; it CANNOT

be done through TAU-EXM-01 devices.

1) Create the "virtual model" of the TAU-MC-01-BL either on TauREX or on the TAU-TRM-01 / TAU-CEM-01.

2) Trigger the linking procedure either from TauREX or from the TAU-TRM-01 / TAU-CEM-01.

3) Pull out the insulating tab.

4) Wait the end of the "one-by-one" linking procedure. 5) Check on TauREX or from TAU-TRM-01 / TAU-CEM-01 for linking success. Consult their user manual.

When extracting the insulating tab, keep both batteries into their lodgements with your thumb, since they can be accidentally pulled out too.

info@hyfirewireless.co.uk

L20-TWDM1B-1400 (vA.1) 2

POWERING UP - FIRST TIME USE - WITHOUT INSULATING TAB

Use this procedure the first time you power up a TAU-MC-01-BL; the detector has not been supplied with the insulating tab. 1) Make sure the Link / program switch is set on "ON". 2) Insert the two supplied batteries into their device's lodgments.

POWERING UP - DEVICE LINKED TO THE SYSTEM

Use this procedure when a TAU-MC-01-BL is successfully linked to its Taurus system and you have to extract one or both batteries (e.g. batteries substitution). 1) Reinsert the battery or both batteries into their lodgments.
If performing a batteries substitution, use two brand new batteries and substitute both of them. Do not touch the Link / program switch.

POWERING UP - RECOVERY

Use this procedure when you fail to link successfully a TAU-MC-01-BL or you want to link it again.

1) Move alternatively the Link / program switch 5 times.

2) Set the Link / program switch on "ON". 3) Insert the two supplied batteries into their device's lodgments.

Always ensure that the batteries are installed properly, with their polarities

LINKING - WAKE-UP - WITHOUT INSULATING TAB

matching the indications on the device.

"Wake-up" linking consists in associating one or more child devices to the Taurus system altogether in a single operation. Wake-up is performed either through the TauREX software or the TAU-TRM-01 / TAU-CEM-01 keyboard-screen interface; it CANNOT be done through TAU-EXM-01 devices. 1) Create the "virtual model" of the TAU-MC-01-BL either on TauREX or on the TAU-TRM-01 / TAU-CEM-01. 2) Power-up the detector (either "first time use" or "recovery").
3) Set the Link / program switch OPPOSITE to "ON". 4) Trigger the wake-up procedure either from TauREX or from the TAU-TRM-01 / TAU-CEM-01. 5) Wait the end of the "wake-up" linking procedure. 6) Check on TauREX or from TAU-TRM-01 / TAU-CEM-01 for linking success. Consult their user manual.

LINKING - ONE-BY-ONE - WITHOUT INSULATING TAB

"One-by-one" linking consists in associating one child device at a time to the Taurus system. This operation is performed either through the TauREX software or the TAU-TRM-01 / TAU-CEM-01 keyboard-screen interface; it CANNOT be done through TAU-EXM-01 devices. 1) Create the "virtual model" of the child device either on TauREX or on the TAU-TRM-01 / TAU-CEM-01. 2) Trigger the linking procedure either from TauREX or from the TAU-TRM-01 / TAU-CEM-01. 3) Power-up the child device (either "first time use" or "recovery"). 4) Set the child device's Link / program switch OPPOSITE to "ON".
5) Wait the end of the "one-by-one" linking procedure. 6) Check on TauREX or from TAU-TRM-01 / TAU-CEM-01 for linking success. Consult their user manual.

TESTING

Magnet test 1) Activate test mode. 2) Apply again the magnet in correspondence of the "magnet test activation area". 3) LED indicators signal "Alarm activation".
Aerosol test 1) Activate test mode. 2) Apply the aerosol test device to the detector. 3) Wait a few seconds. 4) LED indicators signal "Alarm activation".
Heat test 1) Activate test mode. 2) Apply the heat test device to the detector. 3) Wait a few seconds. 4) LED indicators signal "Alarm activation".

Local safety standards may require you to test these devices on a regular basis. Use only suitable aerosol testers / heat test devices supplied by approved manufacturers. Follow their specific use instructions.
Before testing every TAU-MC-01-BL, always activate test mode. This is done by holding a suitable magnet in the "magnet test activation area". When activated, LED indicators signal "Test mode active".

BATTERY FAULTS AND BATTERY SUBSTITUTION PROCEDURE

When one or both batteries are low in charge, a specific fault message is routed to the control panel. If such event occurs:

1) Remove the safety screw.

2) Remove the detector from its base.
3) Remove the batteries cover. 4) Extract both batteries.
5) Insert both new batteries into their holders, oriented as per polarity marks.

When a low battery condition is indicated, both batteries must be changed altogether.

See POWERING UP - DEVICE LINKED TO THE SYSTEM. 6) Reinstall the batteries cover.

Batteries must be brand new.

7) Reinstall the detector. 8) Reinstall the safety screw.

Do not touch the Link / program switch.

Ensure that the batteries are installed properly, with their polarities matching the indications on the device.

Hyfire Wireless Fire Solutions Ltd - Unit B12a, Holly Farm Business Park, Honiley, Warwickshire, CV8 1NP - United Kingdom

www.hyfirewireless.com 3

MAINTENANCE - CLEANING
1) Remove the safety screw. 2) Remove the detector from its base. 3) Smoke entry areas and thermistor area: use a small, soft bristle brush to dislodge any obvious contaminants such as insects, spider webs,
hairs, etc. 4) Smoke entry areas and thermistor area: use a small vacuum tube or dry, clean, compressed air to suck up or blow any remaining small
particles away. 5) Wipe the exterior housing of the detector with a clean, damp, lint-free cloth to remove any surface film that can later attract airborne
contaminants. 6) Install the detector onto its base again. 7) Test the detector. 8) Reinstall the safety screw.

TECHNICAL SPECIFICATIONS *

Specification

Value

Communication range with TAU-TRM-01, TAU-CEM-01 or TAU-EXM-01 network devices

200 m (in open space)

Wireless frequency band

868 MHz

Number of wireless channels

66

Radiated power

14 dBm (25 mW)

Temperature alarm threshold (static)

58 °C

Operating temperature range Maximum humidity (non condensing)

-10 °C to 55 °C 95% RH

IP rating

40

* See TDS-TWDMX technical specification document for further technical data.

BATTERIES SPECIFICATIONS

Specification

Value

Table 2

Batteries type

CR123A (3 V, 1.25 Ah)

Batteries lifespan * Low battery threshold value (nominal)

10 years 2.850 V

* Batteries lifespan depends by environmental conditions, default monitor settings and link quality.

Table 3

SMOKE SENSITIVITY SPECIFICATIONS Detector's sensitivity setting *

Obscuration threshold value for alarm activation

High sensitivity

0.12 dB/m

Medium sensitivity (default setting) Low sensitivity * Detector's smoke sensitivity can be set through TauREX.

0.15 dB/m 0.18 dB/m

Table 4

WARNINGS AND LIMITATIONS

Our devices use high quality electronic components and plastic materials that are highly resistant to environmental deterioration. However, after 10 years of continuous operation, it is advisable to replace the devices in order to minimize the risk of reduced performance caused by external factors. Ensure that this device is only used with compatible control panels. Detection systems must be checked, serviced and maintained on a regular basis to confirm correct operation. Smoke detectors may respond differently to various kinds of smoke particles, thus application advice should be sought for special risks. Detectors cannot respond correctly if barriers exist between them and the fire location and may be affected by special environmental conditions. Refer to and follow national codes of practice and other internationally recognized fire engineering standards. Appropriate risk assessment should be carried out initially to determine correct design criteria and updated periodically.
Use only in Taurus fire detection and alarm systems.
WARRANTY

0051 22 HF-20-014CPR
Hyfire Wireless Fire Solutions Ltd - Unit B12a, Holly Farm Business Park, Honiley, Warwick-
shire, CV8 1NP - United Kingdom

All devices are supplied with the benefit of a limited 5 years warranty relating to faulty materials or
manufacturing defects, effective from the production date indicated on each product. This warranty is invalidated by mechanical or electrical damage caused in the field by incorrect handling or usage. Product must be returned via your authorized supplier for repair or replacement together with full
information on any problem identified. Full details on our warranty and product's returns policy can be obtained upon request.

TAU-MC-01-BL
EN 54-25:2008 EN 54-7:2018
EN 54-5:2017+A1:2018 Class A1R

info@hyfirewireless.co.uk

L20-TWDM1B-1400 (vA.1) 4



References

Microsoft Publisher per Microsoft 365