Schneider Electric RCA iC60 Remote Control Circuit Breaker

Instruction Sheet for Installation and Operation

Product Overview and Identification

This document provides instructions for the Schneider Electric RCA iC60 remote control circuit breaker and its associated Vigi iC60 modules. It covers assembly, installation, wiring, operational modes, and safety precautions.

Available Models:

  • RCA iC60 2P: A9C70112
  • RCA iC60 4P: A9C70114
  • RCA iC60 Ti24 2P: A9C70122
  • RCA iC60 Ti24 4P: A9C70124

Vigi iC60 Ratings:

Available in 25 A, 40 A, and 63 A.

Compatible Accessories:

The RCA iC60 is compatible with accessories such as iOF, iSD, iMN, iMX, iMX+OF, and IMSU.

[Diagram Description: Page 1 shows the RCA iC60 and Vigi iC60 modules, lists model numbers, Vigi iC60 ratings, and compatible accessory types.]

Assembly and Installation

Module Assembly

The RCA iC60 can be combined with Vigi iC60 modules. This involves clipping the Vigi module onto the RCA iC60. The process is shown for both 2-pole (2P) and 3/4-pole (3P/4P) configurations.

[Diagram Description: Page 2 illustrates the physical connection of Vigi iC60 modules (2P and 3P/4P) to the RCA iC60, showing a 180° rotation and clipping mechanism.]

DIN Rail Mounting

Install the assembled RCA iC60 and Vigi iC60 unit onto a standard DIN rail. The installation process includes pushing the unit onto the rail until an audible and tactile [Click!] is heard, indicating secure mounting.

[Diagram Description: Page 2, Step 4 shows the process of mounting the assembled RCA iC60 and Vigi iC60 onto a DIN rail, with a visual cue for secure attachment.]

Modes of Operation and Wiring

Control Modes

The RCA iC60 supports different operational modes:

  • Mode 1: Local or centralized control for opening/closing the circuit breaker.
  • Mode 3: Centralized control with local override capability.

Control signals Y1, Y2, and Y3 (for Ti24 models) manage these operations:

  • Y1: Local control (latched or impulse) or authorized by Y3.
  • Y2: Local control (impulse or latched).
  • Y3 (Ti24): Centralized control (latched).

Reset Authorization (SD Signal)

The behavior of resetting the device after a trip (fault) depends on the SD signal:

  • Mode 1 A / Mode 3 A: Resetting by Y1, Y2, or Y3 is authorized ✔️ after a trip when SD = 1.
  • Mode 1 B / Mode 3 B: Resetting by Y1, Y2, or Y3 is inhibited after a trip when SD = 1.
[Diagram Description: Page 3 details the control modes (Mode 1, Mode 3) and their functions across multiple languages. Page 4, Step 8 elaborates on the difference between reset authorization (Mode A) and inhibition (Mode B) based on the SD signal.]

Wiring and Connections

Connect the RCA iC60 and Vigi iC60 according to the wiring diagrams. Key terminals include:

  • N/P: Power supply connection.
  • Y1, Y2, Y3 (Ti24): Control signal inputs for remote operation.
  • SD: Signal for reset authorization/inhibition.
  • OF: Output signal indicating device status.
  • 24V DC / 0V: Power supply for control circuits.
  • PLC Connections: Inputs and outputs for integration with programmable logic controllers.
ConnectionWire Size (mm²)Torque (N.m)
N/P0.5 - 10 mm²-
Y1, Y20.5 - 2.5 mm²-
OF (11-12 NC, 11-14 NO)0.5 - 1.5 mm²-
SD, Y3, 24V, 0V0.5 - 1.5 mm²-
Ti24 (24 V)0.5 - 1.5 mm²-
Main Power Terminals0.5 - 10 mm²1 N.m
Control Terminals0.5 - 2.5 mm²0.7 N.m
[Diagram Description: Page 3 provides detailed wiring diagrams, terminal specifications, wire sizes, and torque values for connections.]

Functional Features and Safety

Remote Control Capabilities

The RCA iC60 is ready for remote control ▶️ by Y1, Y2, or Y3. Remote control may be impossible under certain conditions, such as thermal auto-protection (Overheat) or if the device is not powered.

[Diagram Description: Page 4, Section 6 lists conditions for RCA iC60 remote control readiness and impossibility, including thermal protection.]

Thermal Auto-Protection (Overheat)

? If the time interval between two remote control commands is less than 1 minute, the RCA iC60 may activate thermal auto-protection (Overheat) for a duration of 5 seconds to 2 minutes and 30 seconds.

[Diagram Description: Page 5, Section 11 illustrates the timing for remote control commands and the resulting overheat protection duration.]

Test and Verification

A TEST function is available to verify the operation of the device.

[Diagram Description: Page 4, Section 7 shows the TEST/VERIFICATION function.]

Safety Warning: Padlocking Device

RISK OF DAMAGING THE RCA IC60 SWITCHGEAR. When the switch is OFF, position the padlocking device in the retracted position before moving the lever. Failure to follow these instructions can result in equipment damage.

[Diagram Description: Page 5, Section 10 highlights the safety warning regarding the padlocking device and potential equipment damage.]

Operational Waveforms

The document includes diagrams illustrating the timing of control signals (Y1, Y2, Y3) and the state of the iC60 (ON/OFF) for various operational modes (Mode 1, Mode 3) and configurations. These waveforms help visualize the device's response to different inputs.

[Diagram Description: Page 6 displays detailed waveform charts for different operational modes and configurations, showing signal timing.]

Manufacturer Information

Schneider Electric Industries SAS
35, rue Joseph Monier
CS 30323
F - 92506 Rueil Malmaison Cedex
www.schneider-electric.com

This product must be installed, connected, and used in compliance with prevailing standards and/or installation regulations. Specifications are subject to change without notice.

PDF preview unavailable. Download the PDF instead.

S1A4079001-09 Adobe PDF library 11.00

Related Documents

Preview Schneider Electric Lighting Technical Guide 2019: Control and Protect Lighting Circuits
Schneider Electric's 2019 Technical Guide provides comprehensive information on controlling and protecting lighting circuits, focusing on energy efficiency, equipment selection, and smart management solutions for professional applications.
Preview Selectivity, Cascading, and Coordination Guide for Low-Voltage Electrical Installations
This comprehensive guide from Schneider Electric details the principles and applications of selectivity, cascading, and coordination in low-voltage electrical systems. It provides essential technical information, standards, and selection tables for various Schneider Electric circuit breakers and protection devices to ensure system safety and reliability.
Preview DNV Type Approval Certificate for Schneider Electric Miniature Circuit Breaker iC60
This document is a Type Approval Certificate issued by DNV for Schneider Electric's Miniature Circuit Breaker, type iC60. It details the product's compliance with DNV rules for classification, including specifications for AC and DC ratings, breaking capacity, and environmental conditions. The certificate is valid until December 31, 2027.
Preview Schneider Electric GV3APN Series Installation and Safety Guide
Official installation and safety guide for Schneider Electric GV3APN series motor protection circuit breakers. Covers models GV3APN01, GV3APN02, GV3APN04, and accessories like GVAPK12 and GVAPP1, detailing safe installation procedures and electrical safety precautions.
Preview Merlin Gerin Low Voltage Switchgear: A Complete Guide by Schneider Electric
Explore the comprehensive range of Merlin Gerin Low Voltage (LV) switchgear from Schneider Electric, featuring SAIF, Shielded Fusegear, NS Feeder Pillars, Opus, MODE distribution equipment, and package substations. This guide details product features, benefits, and applications for safe and efficient electrical distribution.
Preview Schneider Electric Medium Voltage Switchgear Components Catalog 2021
Explore the comprehensive 2021 catalog from Schneider Electric, featuring a wide range of components for Medium Voltage switchgear. Discover solutions for circuit breakers, contactors, switches, disconnectors, and fuses, designed for enhanced connectivity, flexibility, and efficiency.
Preview Schneider Electric A9A27003 Mounting Plate Installation Guide
Detailed instructions for installing the Schneider Electric A9A27003 mounting plate accessory for circuit breakers. Includes steps for DIN rail mounting, assembly, and surface installation, with torque values and dimensions. Compliant with installation regulations.
Preview Schneider Electric TeSys Deca Frame 2 Motor Circuit Breakers: Product References and Specifications
Explore the Schneider Electric TeSys Deca Frame 2 range of motor circuit breakers. This document provides comprehensive product references, technical specifications, and application details for various models including GV2L, GV2LE, GV2ME, GV2P, and GV2RT.