Siemens Data Sheet 6XV1870-3RH60
Product Identification
Product Type Designation
IE TP Cord RJ45/RJ45, 4x2
Product Description
Crossover patch cable, preferred length, preassembled with two RJ45 connectors (10/100/1000/10000MB)
Industrial Ethernet TP XP Cord RJ45/RJ45, CAT 6A, crossed TP cable 4x2, pre-assembled with 2 RJ45 plugs, length 6 m.
Suitability for Use
Easy connection of terminal devices to the IE FC cabling system
Wire Length
6 m
Electrical Data
Number of Electrical Connections
2
Attenuation Factor per Length
- at 10 MHz / maximum: 0.086 dB/m
- at 100 MHz / maximum: 0.28 dB/m
- at 300 MHz / maximum: 0.501 dB/m
- at 600 MHz / maximum: 0.735 dB/m
Impedance
- at 1 MHz ... 100 MHz: 100 Ω
- at 10 MHz ... 600 MHz: 100 Ω
Relative Symmetrical Tolerance
- of the characteristic impedance at 1 MHz ... 100 MHz: 15%
- of the characteristic impedance at 10 MHz ... 600 MHz: 10%
Transfer Impedance per Length / at 10 MHz
10 mΩ/m
Loop Resistance per Length / Maximum
290 mΩ/m
Operating Voltage
- RMS value: 80 V
NVP Value in Percent
80%
Mechanical Data
Number of Electrical Cores
8
Core Diameter
- of AWG26 insulated conductor: 0.5 mm
Outer Diameter
- of inner conductor: 0.5 mm
- of the wire insulation: 1 mm
- of cable sheath: 6.2 mm
Symmetrical Tolerance of the Outer Diameter / of Cable Sheath
0.3 mm
Material
- of the wire insulation: polyethylene (PE)
- of cable sheath: FRNC
Color
- of the insulation of data wires: white/blue, white/orange, white/green, white/brown
- of cable sheath: green
Bending Radius
- with single bend / minimum permissible: 31 mm
- with multiple bends / minimum permissible: 43.5 mm
Weight per Length
50 kg/km
Plug
Connector Type
RJ45
Type of Plug Interlock
latched
Design of Plug-in Connection
RJ45-180
Ambient Conditions
Ambient Temperature
- during operation: -25 ... +80 °C
- during storage: -25 ... +80 °C
- during transport: -25 ... +80 °C
- during installation: -25 ... +80 °C
- note: In fixed installation -40 °C to 80 °C
Fire Behavior
Class of Burning Behaviour / according to EN 13501-6
Eca
Flame resistant according to IEC 60332-1-2, smoke density according to IEC 61034
Chemical Resistance
- to mineral oil: oil resistant according to IEC 60811-2-1 (4 h / 70°C)
- to grease: Conditional resistance
Radiological Resistance / to UV Radiation
not resistant
Protection Class IP
IP20
Product Features
Product Feature
- halogen-free: Yes
- PoE capability: Yes
- PoE+ capability: Yes
- PoE++ capability: Yes
- silicon-free: Yes
Test Voltage
- at AC / core-to-core: 500 V
- at AC / core shield: 1500 V
Standards, Specifications, Approvals
UL/ETL Listing / 300 V Rating
No
UL/ETL Style / 600 V Rating
Yes; E130266 AWM STYLE 21279
Certificate of Suitability
ISO/IEC 11801-1, IEC 61035
EAC Approval
Yes
UL Approval
Yes
RoHS Conformity
Yes
Standard for Structured Cabling
Cat6A
Marine Classification Association
- American Bureau of Shipping Europe Ltd. (ABS): No
- French marine classification society (BV): No
- Det Norske Veritas (DNV): No
- Germanische Lloyd (GL): No
- Lloyd's Register of Shipping (LRS): No
- Nippon Kaiji Kyokai (NK): No
- Polski Rejestr Statkow (PRS): No
Reference Code
- according to IEC 81346-2: WG
- according to IEC 81346-2:2019: WGB
Further Information / Internet Links
- to website: Selection guide for cables and connectors: https://support.industry.siemens.com/cs/ww/en/view/109766358
- to web page: selection aid TIA Selection Tool: https://www.siemens.com/tstcloud
- to web page: SiePortal: https://sieportal.siemens.com/
- to website: Image database: https://www.automation.siemens.com/bilddb
- to website: CAx-Download-Manager: https://www.siemens.com/cax
- to website: Industry Online Support: https://support.industry.siemens.com
Security Information
Siemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement - and continuously maintain - a holistic, state-of-the-art industrial cybersecurity concept. Siemens' products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer's exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7)
Approvals / Certificates
General Product Approval
- Manufacturer Declaration: [CE Mark] [EG-Konf.]
- Declaration of Conformity: [UK CA Mark] [CCC Mark]
- For use in hazardous locations: [ATEX Mark]
- Test Certificates: [Special Test Certificate]
- Maritime application: [PRS Mark] [RMRS Mark]
- Miscellaneous
General Product Approval
- China RoHS
- Fire safety / Physical security
Industrial Communication
PROFINET