Out of the Box
The Memor K package contains:
- Memor K Device
- Rechargeable one-piece battery pack
- Quick Start Guide
- Safety & Regulatory Addendum
- Warranty Addendum
Remove all the components from their packaging; check their integrity and compare them with all the packing documents.
⚠️ CAUTION: Keep the original packaging for use when sending products to the technical assistance center. Damage caused by improper packaging is not covered under the warranty.
General View
The Datalogic Memor K is a mobile computer equipped with a 1D/2D imager.
Front View
- Touch Panel Display
- Keyboard
- Power Button [⏻]
- Scan Key [ ️]
- Home Button
- Recent Button
- Charging LED / Good Read Indicator (located at the top left of the display)
Side View
- K1 Key (Programmable)
- Left Trigger
Top View
Bottom View
- USB Type-C Port [?]
- Microphone
- Contacts for Dock
Back View
- Speaker [?]
- Camera [?]
- LED Flash
- Battery Cover
- Wrist Strap
Other Controls
- K2 Key (Programmable)
- Right Trigger
Battery Installation
To install the battery:
- Slide the battery cover switch to the unlock position [?]; lift and remove the battery cover.
- Insert the battery pack into the slot, top first, and press it into place.
- Insert the battery cover (bottom side first) and press it into place; slide the battery cover switch to the lock position [?].
⚠️ CAUTION: Ensure all the components are dry before performing any type of connection to the Memor K. Any damage caused by use of wet equipment is not covered by warranty.
Charging Instructions
The battery pack is not initially fully charged. After installing the battery, charge it with the power supply or with the single slot dock for a minimum of 3.5 hours.
During the charging process, the charging LED [?] positioned at the top left side of the display glows red constantly. Once the charging process has been completed, the charging LED glows green constantly.
? NOTE: Using the device while the battery is charging will significantly increase the time required to reach a full charge.
? NOTE: The Memor K may get warm during charging. This is normal and does not mean a malfunction.
Turn On/Off the Device
To turn on the Memor K, press and hold the Power Button [⏻] for at least 3 seconds.
To turn off the Memor K, press and hold the Power Button until the Reboot Options Menu appears, and then tap Power Off.
Force Restart
Press and hold the Power Button for at least 10 seconds to force restart.
Scanning and Imaging
To scan a bar code symbol:
- Point the scan window at the bar code.
- Press one of the scan triggers. A red spot illuminates the symbol, which is captured and decoded.
If the scan has been successful:
- If enabled, the good read beep plays.
- If enabled, the GreenSpot projects a green spot onto the bar code image.
- If enabled, the good read indicator [?] positioned at the top left side of the display glows solid green.
- The decode results display on the screen.
Aiming Beam
The aiming beam is smaller when the device is closer to the barcode and larger when it is farther from the barcode.
Scan symbols with smaller bars or elements (mil size) should be read closer to the unit, and those with larger bars or elements (mil size) should be read farther from the unit.
Linear Bar Code: Scan symbols with smaller bars or elements (mil size) should be read closer to the unit.
2D Matrix Symbol: Scan symbols with larger bars or elements (mil size) should be read farther from the unit.
Charging Methods
Charge with the USB
Use the USB Type-C cable (sold separately, p/n 94A050044) in conjunction with the power supply adapter (sold separately, p/n 94ACC0316) to charge the device from a power outlet.
⚠️ CAUTION: Use only the Datalogic power supply 94ACC0316 to power the Memor K.
Charge with the Single Slot Dock
Insert the device into the dock with the screen facing front and the head facing up.
? NOTE: For information on the single slot dock, refer to the Quick Start Guide included in the dock's box.
⚠️ CAUTION: Use only a Datalogic approved power supply to power the single slot dock.
SD Card Installation
Datalogic recommends the use of Single Level Cell (SLC) industrial grade microSD or microSDHC memory cards for maximum performance and durability. Contact the sales support team to select the memory card for your device.
? NOTE: If you use your microSD/SDHC card as portable storage, format it to Fat32 before installation.
To install the memory card:
- Remove the battery cover (see "Battery Installation", step 1).
- Remove the battery.
- Insert the memory card into the slot with the written part upward.
- Replace the battery and the battery cover (see "Battery Installation", steps 3 and 4).
Reference Documentation and Support
Reference Documentation
For further information regarding Memor K, refer to the SDK Help on-line and to the Memor K User's Manual, downloadable from our website www.datalogic.com.
Support Through the Website
Datalogic provides several services as well as technical support through its website.
Log on to www.datalogic.com.
For quick access, from the home page click on the search icon [?], and type in the name of the product you're looking for. This allows you access to download Data Sheets, Manuals, Software & Utilities, and Drawings.
Hover over the Support & Service menu for access to Services and Technical Support.
See the Safety & Regulatory Addendum included with your product for additional regulatory, safety, and legal information.