FIBARO Flood Sensor
Z-Wave Protocol Implementation Conformance Statement
General Information
- Product Identifier: FGFS-101
- Brand Name: FIBARO
- Product Version: HW: 1 FW: 3.04:03.04
- Z-Wave Certification #: ZC10-19076583
Product Features
- Firmware Updatable: Updatable by Consumer by RF
- Supported Notification Types: Water Alarm
- Battery Type: CR123A
- Battery Quantity: 1
- Sensors: Air Temperature
- Color: White
Z-Wave Product Information
- Supports Z-Wave Beaming Technology?: No
- Supports Z-Wave Network Security?: Yes
- Supports Z-Wave AES-128 Security S0?: Yes
- Supports Security S2?: No
- SmartStart Compatible?: No
Z-Wave Technical Information
- Z-Wave Frequency: Hong Kong
- Z-Wave Product ID: 0x9003
- Z-Wave Product Type: 0x0B01
- Z-Wave Hardware Platform: ZM5202
- Z-Wave Development Kit Version: 6.51.07
- Z-Wave Library Type: Enhanced 232 Slave
Association Group Information
Group # / Max Nodes | Description |
---|---|
1 / 1 | "Lifeline" reports the device status and allows for assigning single device only (main controller by default). |
2 / 5 | "Flood Control" devices in this group will be switched on or off when flood status changes (done via BASIC SET command frames). |
3 / 5 | "Flood Alarm" is assigned to the device status - devices in this group will receive notification about flood detection or cancellation. Useful for devices that can trigger alarms. |
4 / 5 | "Tamper Alarm" is assigned to the TMP button and tilt sensor - devices in this group will receive a notification when the sensor is moved or the cover is taken off (which normally holds the button). Useful for devices that can trigger alarms. Functionality can be altered by parameter 74. |
Supported Command Classes (19):
- Application Status
- Association V2
- Battery
- CRC16 Encapsulation
- Firmware Update Meta-Data V3
- Multi Channel Association V2
- Powerlevel
- Sensor Alarm
- Version V2
- Z-Wave Plus Info V2
- Association Group Info
- Basic
- Configuration
- Device Reset Locally
- Manufacturer Specific V2
- Notification V5
- Security S0
- Sensor Multilevel V5
- Wake Up V2
Controlled Command Classes (2):
- Basic
- Multi-Channel V4