Overview
[Image Description: Two handheld optical multi-meters are shown. One is orange and black, featuring a screen, buttons labeled LIGHT, REF, LED, and λ, and a connector port. The other is black and orange, smaller, with a single connector port.]
The TELRAN Optical Multi-meter is a handheld, luminous power red pen all-in-one device designed for measuring optical signal capacity and testing fiber-optic routes for continuity (closed-open testing). It utilizes a single-chip microprocessor for control and offers comprehensive functionality. It is widely used in optical cable construction and maintenance, fiber-optic communication, optical cable sensing, and other related fields. The machine's body design conforms to human body engineering requirements, employing advanced cold molding technology for a beautiful and durable finish. The device features a built-in detector and laser for protection. Key features include a delicate appearance, auto power off, two red light modes, three backlight modes, wavelength memory function, fiber-optical work identification, manual calibration, high-capacity red light, and a wide testing range.
Note: The version of the instruction is subject to change without notice.
Address: 19 Hayezira St. Industrial Zone Ramla 7255616
Fax: 03-5214524 | Phone: 03-5575110
Certification: URS ISO 9001
Support: Technical support *2023
Product Characteristics
- Supports simultaneous display of linear (mW) and nonlinearity index (dB).
- Supports auto power off.
- Supports on/off background light.
- Supports customer self-alignment.
- Supports SC, FC, and ST interfaces.
- Charging battery life is 48 hours.
- Supports charging via computer power supply.
- Supports memory wavelength function.
- Supports fiber-optical work identification.
- Supports red light normally flash and flicker modes.
Technical Index
Parameter | Specification |
---|---|
Wavelength range | 800 ~ 1700 nm |
Connector | FC/SC/ST |
Type of Detector | InGaAs |
Power measurement range | -70 ~ +3 dB or -50 ~ +20 dB |
Uncertainty | ±5% |
Standard wavelength (nm) | 850, 980, 1300, 1310, 1490, 1550, 1625 |
Display resolution | Linear indication: 0.1% / Logarithmic indication: 0.01dBm |
Working wavelength of red light | 650nm |
Red power | 1MW, 5MW, 10MW, 20MW, 30MW |
Working temperature (°C) | -10 ~ +60 |
Storage temperature (°C) | -25 ~ +70 |
Auto off time (min) | 10 |
Battery Working Time (h) | ≥48 |
Instrument size (mm) | 190 * 100 * 48 |
Power Supply | No. 5 battery *3 or rechargeable lithium battery |
Weight (g) | 270 |
Notes:
- Range of wavelength: The optical power meter will operate effectively within the specified min-λ to max-λ range, meeting all indicator requirements.
- Power measurement range: The maximum power the meter can measure according to the required indicators.
- Uncertainty: The error between the test results and standard test results over a standard optical power.
Address: 19 Hayezira St. Industrial Zone Ramla 7255616
Fax: 03-5214524 | Phone: 03-5575110
Certification: URS ISO 9001
Support: Technical support *2023
Directions for Use (English Edition)
Press Key Description
- Startup & Shutdown: Press the key for 1 second to start up. Long press the key while the device is on to shut down. The device defaults to auto power off (10 min). To close auto power off, shortly press the key until the power indicator on the LCD disappears.
- UNIT: Changes the data display unit. Select from dBm, dB, or nW. Test data will show the corresponding result. The conversion relationship is: 10 log(nW) = 0(dBm).
- REF: Performs automatic zero clearing. Press to set the current test result as a reference value for relative power measurement. The screen will display the set dBm value.
- λ (Wavelength): Selects from 6 types of different wavelengths (850nm, 1300nm, 1310nm, 1490nm, 1550nm, 1625nm). The selected wavelength is shown on the LCD screen.
- LIGHT: Turns the red light on/off. A short press starts or closes the red light. When on, the LCD displays "650" (referring to 650nm wavelength).
- GLINT: When the red light is on, a short press makes the red light flicker. Pressing again turns it off.
- Fiber-optical Work Identification Function: Pressing "REF" + "UNIT" keys simultaneously starts fiber-optical work identification, identifying fiber-optical work frequency. Pressing this combination again closes the function.
LCD Display Description
The measured power value is displayed in units of dB, dBm, mW, µW, or nW. The display also shows the selected wavelength (6 types) and the current work status.
[Image Description: A close-up of the optical multi-meter's screen shows "1310nm", "Lo", "-70.00 dBm", and buttons labeled LIGHT, REF, LED, dB, λ.]
Background Light Switch
LCD POWER | GLINT+LIGHT | Display | Switch backlight tips |
---|---|---|---|
[Text: LCD Power] | [Text: Glint + Light] | [Text: Display] | [Text: Switch backlight tips] |
Address: 19 Hayezira St. Industrial Zone Ramla 7255616
Fax: 03-5214524 | Phone: 03-5575110
Certification: URS ISO 9001
Support: Technical support *2023
Calibration Function Description
Pressing the "REF" + "UNIT" keys simultaneously enters user mode. The letter "CAL" will appear in the lower right corner of the screen. The following functions are valid after pressing this combination key:
Function | Key | Remark |
---|---|---|
Increasing 0.05dB | REF | 1.01158 |
Reducing 0.05dB | UNIT | 0.99855 |
Keep | Power key | Shortly press (Stored in flash) |
Switching wavelength | Enter | |
Restore factory settings | REF+UNIT | Displays "FAC", and reads the default value in array at the same time. |
Note: Pressing "REF" and "UNIT" keys simultaneously puts the all-in-one machine into calibration mode and restores factory status.
Measurement to Relative Power and Absolute Power
- Absolute Power: If the measurement wavelength is set to 1310nm, the detected light is accessed, and the screen displays the current value, including linearity and nonlinearity of the absolute light power.
- Relative Power: After setting the wavelength correctly and in absolute light power mode, access the measuring light. Press the REF key again when the current power value is displayed. The current power value becomes the reference value (in dBm). The screen will show the current absolute power value and a relative power value of 0dB. When another measuring light is accessed, it displays the absolute light power value and the relative light power value of the current measuring light.
Standard Configuration
The package includes the host machine, product warranty card, certificate, instructions, Oxford rolls, three AA batteries, and an adapter (SC and FC standard, ST optional).
Charging Function
When the electric quantity index is not displayed, or the electric quantity is insufficient for normal operation, the index will flash every 1 second, and the device will automatically power off after 10 seconds. Do not attempt to start the device at this time; it should be started after charging with the matched power adapter.
Address: 19 Hayezira St. Industrial Zone Ramla 7255616
Fax: 03-5214524 | Phone: 03-5575110
Certification: URS ISO 9001
Support: Technical support *2023
Solutions to Common Faults
Malfunction Tips | Cause | Solution |
---|---|---|
LCD monitor weak | Insufficient power | Charge or change battery |
Could not display when starting | Lack of power or other | Restart machine or charge, change battery |
Abnormal data display of LCD | Adapter fault, dirty or be locked | Reconnect adapter and clean sensor |
Red light weak | Insufficient power | Charge or change battery |
Routine Maintenance and Cleaning
- Please keep the sensor clean frequently, ensuring no fat, pollution, or dirty/non-standard adapters are used. Do not insert the end face of a poorly polished surface, as this can damage the end face and lead to testing errors.
- Use an adapter whenever possible.
- When the machine is not in use, cover the dust cap to keep the end face clean, preventing exposure to air and dust that could cause measurement errors.
- Carefully plug the optical adapter connector to avoid port scratches.
- Clean the sensor surface periodically. When cleaning, wipe gently in a circular motion with a special cleaning swab.
Quality Guarantee
- Within twelve months of the user receiving the goods, TELRAN COMMUNICATION (1986) LTD guarantees the quality and workmanship of its products. If the purchased product is found to have quality problems within this period, the company will provide corresponding treatment or replacement. However, the company's responsibility will not exceed the purchase value of the product.
- If a problem occurs during use and cannot be resolved by the common failure prompt program, the user must not open the shell; please contact the company.
- For malfunctions caused by product defects, the company will be responsible for free repair or replacement.
Note: This warranty is only applicable to the normal use of the instrument. For failures caused by product quality or material defects due to damage or improper use, the company is responsible for free repair or replacement. The company reserves the right to refuse warranty service for unforeseen circumstances, improper use, or unauthorized maintenance.