Instruction Manual for Schreder models including: CLB1, CLB1 Circle LED Base, Circle LED Base, LED Base, Base

Schreder-CLB VALENTINO-Installation Instructions-RevB

Sustainable lighting: CIRCLE LED BASE for easy luminaire retrofitting | Schréder

Schreder-CLB VALENTINO-Installation Instructions-RevB (2.66 MB)

Schreder-CLB VALENTINO-Installation Instructions-RevB | Schréder Corporate


File Info : application/pdf, 3 Pages, 2.66MB

PDF preview unavailable. Download the PDF instead.

Schreder-CLB VALENTINO-Installation Instructions-RevB
98mm
Copyright © Schréder S.A. 2024 - Executive Publisher: Stéphane Halleux - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.

CIRCLE LED BASE 1&2
for VALENTINO

ENG INSTALLATION INSTRUCTIONS DEU INSTALLATIONSANLEITUNG FRA INSTRUCTIONS DE MONTAGE SRP UPUTSTVA ZA INSTALACIJU

ITA POL SPA ARA

ISTRUZIONI DI INSTALLAZIONE INSTRUKCJE MONTAU INSTRUCCIONES DE INSTALACIÓN
 

NLD RUS POR

INSTALLATIE INSTRUCTIES DAN INSTALLATIONSVEJLEDNING    RON INSTRUCIUNI DE INSTALARE INSTRUÇÕES DE INSTALAÇÃO SWE INSTALLATIONSANVISNING

HUN TELEPÍTÉSI ÚTMUTATÓ CHI  UKR   

All the tightening torques

values are given for assemblies

without the addition of a

grease decreasing friction.

4

PZ2

VALENTINO WITH CLB1*

141.8mm

132mm 319mm

182mm 319mm
302.6mm

193.9mm

302.6mm 94.1mm

193mm

243mm

*CLB2 is also available for VALENTINO, with the same adaptation plate size dimensions (only the cut-out being different)

03-77-296 | rev B | 07-2024

www.schreder.com

1/3

1

2

4

Disconnect the luminaire from network and clean the surface

Open the luminaire for gear compartment and light source access

3

4

Copyright © Schréder S.A. 2024 - Executive Publisher: Stéphane Halleux - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.

Disconnect mains and remove connectors from cables KEEP THESE FOR LATER USE!
5 PZ2

Disconnect HID cables
6

4xM5

Remove screws holding the optical compartment. KEEP THESE FOR LATER USE!

Remove optical compartment

03-77-296 | rev B | 07-2024

www.schreder.com

2/3

Copyright © Schréder S.A. 2024 - Executive Publisher: Stéphane Halleux - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.

7

8

PZ2

4xM5

Remove gearplate
9

Place and fasten the adaptation plate into position in the luminaire body with the previously removed screws (tightening torque: 2Nm)
10
b.
a. a.

PZ2

1xM5

Put connectors on mains cable and CLB cable

a. Connect earthing cable of the adaptation plate
to luminaire body
b. Connect mains cable to CLB unit

11

12

4

Close the luminaire 03-77-296 | rev B | 07-2024

Connect the assembly back on network

www.schreder.com

3/3



References