Installation Guide for SENECA models including: Z-PASS2-RT, Z-PASS2-RT-S, Z-PASS2-RT Z-PASS2-RT-S IoT Multifunction Controllers, Z-PASS2-RT Z-PASS2-RT-S, IoT Multifunction Controllers, Multifunction Controllers, Controllers
INSTALLATION MANUAL Z-PASS2-RT Z-PASS2-RT-S PRELIMINARY WARNINGS The word WARNING preceded by the symbol indicates conditions or actions that put the user's safety at risk. The word ATTENTION preceded by the symbol indicates conditions or actions that might damage the instrument or the connected equipment. The warranty shall become null and void in the event of improper use or tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if the instructions contained in this manual are not followed. WARNING: The full content of this manual must be read before any operation. The module must only be used by qualified electricians. Specific documentation is available using the QR-CODE shown on page 1. The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to electrostatic discharges. Take appropriate measures during any operation. Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling). The symbol on the product or its packaging shows the product must be surrendered to a collection centre authorized to recycle electrical and electronic waste. DOCUMENTATION Z- PASS2-RT DOCUMENTATION Z- PASS2-RT-S SENECA s.r.l.; Via Austria, 26 35127 PADOVA ITALY; Tel. +39.049.8705359 - Fax +39.049.8706287 CONTACT INFORMATION Technical support support@seneca.it Product information sales@seneca.it This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised. The content of this document corresponds to the described products and technologies. Stated data may be modified or supplemented for technical and/or sales purposes. MI00612-4-EN INSTALLATION MANUAL 1/4 MODULE LAYOUT 52,5 mm USB MOBILE ANT. 111 mm SW2 IDC10 SIM Card LAN WAN 102,5 mm GPS ANT. SIGNALS VIA LED ON FRONT PANEL Weight: 250 g; Enclosure: PA6, Black LED PWR RUN DIDO1....DIDO6 VPN SRV RX1 / RX2 / RX4 TX1 / TX2 / TX4 ETH ACT (Green) ETH LNK (Yellow) NET DATA GPS BAT See user manual PWR (MODEM) STATUS On Off On Flashing Off On Off On Flashing On Flashing Off On Flashing Flashing Flashing On On Flashing (Only ) On Flashing Off On Flashing Off On Off On Flashing Off On Off LED meaning Device powered correctly Device not powered Locking system The module is working correctly System Locked / Booting Input or output activated Input or output deactivated VPN connection active VPN connection problems VPN BOX "SERVICE" connection is working correctly VPN BOX "SERVICE" connection in error VPN BOX "SERVICE" connection disabled Incorrect RS485/ RS232 connection Reception of data packet completed on RS485/ RS232 Transmission of data packet completed on RS485/ RS232 Packet transit on Ethernet port Ethernet port connected Signal level reporting Modem not correctly adjusted Modem adjusted on 4G network Modem adjusted on 2G or 3G network Modem off or not adjusted Data connection enabled and correctly adjusted Data connection enabled but in error Data connection disabled GPS signal present GPS signal absent Battery connected and working properly Low or faulty battery Battery not in use (UPS not active) Device powered correctly Device not powered MI00612-4-EN INSTALLATION MANUAL 2/4 TECHNICAL SPECIFICATIONS CERTIFICATIONS POWER SUPPLY ENVIRONMENTAL CONDITIONS ASSEMBLY CONNECTIONS PROCESSOR MEMORY FEATURES COMMUNICATION PORTS 11 ÷ 40Vdc; 50 ÷ 60Hz; Max absorption: 11 W Operating temperature: from -25°C to +65°C; Humidity: 10% ÷ 90% non condensing. Storage temperature: from -30°C to +80°C; Degree of protection: IP20 35mm DIN rail IEC EN60715 Removable 3.5 mm pitch terminal block, 1.5 mm2 max cable section ARM 32 bit 512MB RAM and 4GB Flash; PUSH-PUSH type slot for micro SD Integrated Web Server and update via Web Server COM1: RS232 / RS485 (on terminals), COM2: RS485 (on terminals or IDC10) COM4: RS485 (on terminals); maximum Baud rate 115kbps; minimum 200 bps; USB HOST type A ETH1 and ETH2 Fast Ethernet RJ45 10/100Mbps, Maximum connection distance: 100 m CAN on terminals or on IDC10 (May not be present on all models) RS485 RS232 RS485 USB ISOLATION DI / DO Comm. ETH Intput LAN Output Comm. Analog Input Comm. ETH WAN USB Power Supply DIGITAL INPUTS OUTPUTS Number of inputs: 6 max.; Number of outputs: 6 max.; Absorbed current: 3mA @ 12Vdc, 5mA @ 24Vdc. Voltage OFF<4V, ON>8V MAX. current (Vout+) 50mA Voltage (Vext+): 10 ÷ 28Vdc. MAX. current: 200 mA per channel Protect the outputs using a 1.5A fuse as shown in the wiring diagrams ANALOGUE INPUTS Voltage 0 ÷ 30Vdc, impedance 200k Current 0 ÷ 25mA, impedance ~ 50 AUXILIARY VOLTAGE OUTPUT V AUX: 12Vdc; Max. 50 mA Global coverage Model 4G/LTE 4G MODEM FREQUENCIES LTE-FDD: B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/ B19/B20/B25/B26/B28 LTE-TDD: B38/B39/B40/ B41; WCDMA: B1/B2/B4/B5/B6/B8/B19/GSM: B2/B3/B5/B OUTPUT POWER GSM900: 32.75dBm, DCS1800: 29.07dBm, WCDMA: 23.13dBm, 23.27 dBm, LTE: 23.1dBm, 23.2dBm, 21.7dBm, 23.19dBm, 23.14dBm, 23.7dBm, 23.39dBm. GNSS GPS / GLONASS / BeiDou (compass) / Galileo / QZSS SIM CARD SLOT Push-push type for mini SIM card 15 X 25 mm (on instrument case back) INSTALLATION REGULATIONS The module has been designed for vertical installation on a DIN 46277 rail. For optimal operation and long life, adequate ventilation must be provided. Avoid positioning ducting or other objects that obstruct the ventilation slots. Avoid mounting modules over heat-generating equipment. Installation in the bottom part of the electrical panel is recommended. ATTENTION: These are open type devices intended for installation in a final casing/panel that offers mechanical protection and protection against the spread of fire. ModBUS CONNECTION RULES 1) Install the modules in the DIN rail (120 max) 2) Connect the remote modules using cables of an appropriate length. The following table shows cable length data: -Bus length: maximum length of the Modbus network according to the Baud Rate. This is the length of the cables that connect the two farthest modules (see Diagram 1). -Derivation length: maximum length of a derivation 2 m. For maximum performance, it is recommended to use special shielded cables, designed specifically for data communication. MI00612-4-EN INSTALLATION MANUAL 3/4 WARNING This is a Class A product. In a residential environment this equipment may cause radio interference. In this case, the user may have to take adequate countermeasures. IDC10 CONNECTOR Power supply and Modbus interface are available also using the Seneca DIN rail bus, via the IDC10 rear connector, or the Z-PC-DINAL2-52,5 accessory. Power supply DC + CAN GND / RS485 GND Power supply DC - Back connector (IDC 10) The illustration shows the meanings of the various IDC10 connector pins if signals are to be sent via them directly. CAN H / RS485 A CAN L / RS485 B IDC10 ELECTRICAL CONNECTIONS CAUTION Switch the module off before connecting inputs and outputs. To meet the electromagnetic immunity requirements: - use shielded signal cables; - connect the shield to a preferential instrumentation earth system; - separate shielded cables from other cables used for power installations (transformers, inverters, motors, etc...). POWER SUPPLY RS232 / RS485 COM1 RS485 COM2 RS485 COM4 CAN (Z-PASS2-RT-S) 29 30 5 Tx - RS232 13 A - RS485 21 A - RS485 21 6 Rx - RS232 14 B - RS485 22 B - RS485 22 31 7 A - RS485 15 GND 23 23 CAN L 32 8 B - RS485 16 24 24 CAN H 16 GND 29 GND 32 GND ANALOGUE INPUTS: VOLTAGE + V1 + V2 25 +V AUX 26 AI 1 27 AI 2 28 CAI ANALOGUE INPUTS: CURRENT mA 1 mA 2 25 +V AUX 26 AI 1 27 AI 2 28 CAI + V EXT DIGITAL INPUTS: 1 - 3 FUSE: 1.5A 9 + V EXT 10 DI 1 11 DI 2 12 DI 3 CAI: COMMON ANALOG INPUT CAI: COMMON ANALOG INPUT CIO: COMMON I/O 20 CIO DIGITAL INPUTS: 4 - 6 DIGITAL OUTPUTS: 1 - 3 DIGITAL OUTPUTS: 4 - 6 + V EXT FUSE: 1.5A 9 + V EXT 17 DI 4 18 DI 5 19 DI 6 20 CIO + V EXT FUSE: 1.5A LOAD LOAD LOAD 9 + V EXT 10 DO 1 11 DO 2 12 DO 3 20 CIO + V EXT FUSE: 1.5A LOAD LOAD LOAD 9 + V EXT 17 DO 4 18 DO 5 19 DO 6 20 CIO CIO: COMMON I/O CIO: COMMON I/O SETTING THE DIP-SWITCHES CIO: COMMON I/O WARNING The DIP-switch settings are read only at boot time. At each change, perform a restart. For use and settings via DIP-SWITCH SW1 see the user manual available on the website on the web page dedicated to the product. SW2 DIP SWITCH SETTING: (Z- PASS2-RT-S ONLY): Through DIP SWITCH SW2 it is possible to select RS485 or CAN communication through the IDC10 connector: ON SW2 KEY OFF ON RS485 ACTIVATION ON OFF CAN ACTIVATION OFF MI00612-4-EN INSTALLATION MANUAL 4/4Adobe PDF Library 17.0 Adobe InDesign 18.5 (Windows)