INSTALLATION MANUAL
Z-PASS2-RT Z-PASS2-RT-S
PRELIMINARY WARNINGS
The word WARNING preceded by the symbol indicates conditions or actions that put the user's safety at risk. The word ATTENTION preceded by the symbol indicates conditions or actions that might damage the instrument or the connected equipment. The warranty shall become null and void in the event of improper use or tampering with the module or devices supplied by the manufacturer as necessary for its correct operation, and if the instructions contained in this manual are not followed.
WARNING: The full content of this manual must be read before any operation. The module must only be used by qualified electricians. Specific documentation is available using the QR-CODE shown on page 1.
The module must be repaired and damaged parts replaced by the Manufacturer. The product is sensitive to electrostatic discharges. Take appropriate measures during any operation. Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling). The symbol on the product or its packaging shows the product must be surrendered to a collection centre authorized to recycle electrical and electronic waste.

DOCUMENTATION Z- PASS2-RT

DOCUMENTATION Z- PASS2-RT-S

SENECA s.r.l.; Via Austria, 26 ­ 35127 ­ PADOVA ­ ITALY; Tel. +39.049.8705359 - Fax +39.049.8706287

CONTACT INFORMATION

Technical support

support@seneca.it

Product information

sales@seneca.it

This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised. The content of this document corresponds to the described products and technologies. Stated data may be modified or supplemented for technical and/or sales purposes.

MI00612-4-EN

INSTALLATION MANUAL

1/4

MODULE LAYOUT
52,5 mm
USB
MOBILE ANT.

111 mm

SW2 IDC10 SIM Card
LAN WAN
102,5 mm

GPS ANT.

SIGNALS VIA LED ON FRONT PANEL

Weight: 250 g; Enclosure: PA6, Black

LED PWR
RUN
DIDO1....DIDO6 VPN
SRV
RX1 / RX2 / RX4 TX1 / TX2 / TX4 ETH ACT (Green) ETH LNK (Yellow)
NET
DATA
GPS BAT See user manual PWR (MODEM)

STATUS On Off On
Flashing Off On Off On
Flashing On
Flashing Off On
Flashing Flashing Flashing
On On Flashing (Only ) On Flashing Off On Flashing Off On Off On Flashing Off On Off

LED meaning Device powered correctly
Device not powered Locking system
The module is working correctly System Locked / Booting Input or output activated Input or output deactivated VPN connection active VPN connection problems
VPN BOX "SERVICE" connection is working correctly VPN BOX "SERVICE" connection in error VPN BOX "SERVICE" connection disabled Incorrect RS485/ RS232 connection
Reception of data packet completed on RS485/ RS232 Transmission of data packet completed on RS485/ RS232
Packet transit on Ethernet port Ethernet port connected Signal level reporting
Modem not correctly adjusted
Modem adjusted on 4G network Modem adjusted on 2G or 3G network
Modem off or not adjusted Data connection enabled and correctly adjusted
Data connection enabled but in error Data connection disabled GPS signal present GPS signal absent
Battery connected and working properly Low or faulty battery
Battery not in use (UPS not active) Device powered correctly Device not powered

MI00612-4-EN

INSTALLATION MANUAL

2/4

TECHNICAL SPECIFICATIONS

CERTIFICATIONS

POWER SUPPLY ENVIRONMENTAL
CONDITIONS ASSEMBLY CONNECTIONS PROCESSOR MEMORY FEATURES
COMMUNICATION PORTS

11 ÷ 40Vdc; 50 ÷ 60Hz; Max absorption: 11 W
Operating temperature: from -25°C to +65°C; Humidity: 10% ÷ 90% non condensing. Storage temperature: from -30°C to +80°C; Degree of protection: IP20
35mm DIN rail IEC EN60715 Removable 3.5 mm pitch terminal block, 1.5 mm2 max cable section
ARM 32 bit
512MB RAM and  4GB Flash; PUSH-PUSH type slot for micro SD
Integrated Web Server and update via Web Server
COM1: RS232 / RS485 (on terminals), COM2: RS485 (on terminals or IDC10) COM4: RS485 (on terminals); maximum Baud rate 115kbps; minimum 200 bps; USB HOST type A ETH1 and ETH2 Fast Ethernet RJ45 10/100Mbps, Maximum connection distance: 100 m CAN on terminals or on IDC10 (May not be present on all models)
RS485 RS232 RS485 USB

ISOLATION

DI / DO

Comm.

ETH

Intput

LAN

Output

Comm.

Analog Input

Comm. ETH WAN

USB Power Supply

DIGITAL INPUTS OUTPUTS

Number of inputs: 6 max.; Number of outputs: 6 max.; Absorbed current: 3mA @ 12Vdc, 5mA @ 24Vdc. Voltage OFF<4V, ON>8V MAX. current (Vout+) 50mA Voltage (Vext+): 10 ÷ 28Vdc. MAX. current: 200 mA per channel Protect the outputs using a 1.5A fuse as shown in the wiring diagrams

ANALOGUE INPUTS Voltage 0 ÷ 30Vdc, impedance 200k Current 0 ÷ 25mA, impedance ~ 50

AUXILIARY VOLTAGE OUTPUT

V AUX: 12Vdc; Max. 50 mA

Global coverage Model 4G/LTE 4G MODEM FREQUENCIES LTE-FDD: B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/ B19/B20/B25/B26/B28
LTE-TDD: B38/B39/B40/ B41; WCDMA: B1/B2/B4/B5/B6/B8/B19/GSM: B2/B3/B5/B

OUTPUT POWER

GSM900: 32.75dBm, DCS1800: 29.07dBm, WCDMA: 23.13dBm, 23.27 dBm, LTE: 23.1dBm, 23.2dBm, 21.7dBm, 23.19dBm, 23.14dBm, 23.7dBm, 23.39dBm.

GNSS

GPS / GLONASS / BeiDou (compass) / Galileo / QZSS

SIM CARD SLOT Push-push type for mini SIM card 15 X 25 mm (on instrument case back)

INSTALLATION REGULATIONS
The module has been designed for vertical installation on a DIN 46277 rail. For optimal operation and long life, adequate ventilation must be provided. Avoid positioning ducting or other objects that obstruct the ventilation slots. Avoid mounting modules over heat-generating equipment. Installation in the bottom part of the electrical panel is recommended.
ATTENTION: These are open type devices intended for installation in a final casing/panel that offers mechanical protection and protection against the spread of fire.
ModBUS CONNECTION RULES

1) Install the modules in the DIN rail (120 max) 2) Connect the remote modules using cables of an appropriate length. The following table shows cable length data: -Bus length: maximum length of the Modbus network according to the Baud Rate. This is the length of the cables that connect the two farthest modules (see Diagram 1). -Derivation length: maximum length of a derivation 2 m.
For maximum performance, it is recommended to use special shielded cables, designed specifically for data communication.

MI00612-4-EN

INSTALLATION MANUAL

3/4

WARNING
This is a Class A product. In a residential environment this equipment may cause radio interference. In this case, the user may have to take adequate countermeasures.

IDC10 CONNECTOR

Power supply and Modbus interface are available also using the Seneca DIN rail bus, via the IDC10 rear connector, or the

Z-PC-DINAL2-52,5 accessory.

Power supply DC +

CAN GND / RS485 GND

Power supply DC -

Back connector (IDC 10) The illustration shows the meanings of the various IDC10 connector pins if signals are to be sent via them directly.

CAN H / RS485 A CAN L / RS485 B

IDC10

ELECTRICAL CONNECTIONS

CAUTION

Switch the module off before connecting inputs and outputs.

To meet the electromagnetic immunity requirements:

- use shielded signal cables; - connect the shield to a preferential instrumentation earth system; - separate shielded cables from other cables used for power installations (transformers, inverters, motors, etc...).

POWER SUPPLY RS232 / RS485 COM1 RS485 COM2

RS485 COM4

CAN (Z-PASS2-RT-S)

29 30

5 Tx - RS232

13 A - RS485

21 A - RS485

21

6 Rx - RS232

14 B - RS485

22 B - RS485

22

31

7 A - RS485

15 GND

23

23 CAN L

32

8 B - RS485

16

24

24 CAN H

16 GND

29 GND

32 GND

ANALOGUE INPUTS: VOLTAGE

+

V1

+

V2

25 +V AUX 26 AI 1 27 AI 2 28 CAI

ANALOGUE INPUTS: CURRENT

mA

1

mA

2

25 +V AUX 26 AI 1 27 AI 2 28 CAI

+ V EXT

DIGITAL INPUTS: 1 - 3
FUSE: 1.5A

9 + V EXT 10 DI 1 11 DI 2 12 DI 3

CAI: COMMON ANALOG INPUT

CAI: COMMON ANALOG INPUT

CIO: COMMON I/O

20 CIO

DIGITAL INPUTS: 4 - 6

DIGITAL OUTPUTS: 1 - 3

DIGITAL OUTPUTS: 4 - 6

+ V EXT

FUSE: 1.5A

9 + V EXT
17 DI 4 18 DI 5 19 DI 6 20 CIO

+ V EXT

FUSE: 1.5A
LOAD LOAD LOAD

9 + V EXT 10 DO 1 11 DO 2 12 DO 3
20 CIO

+ V EXT

FUSE: 1.5A
LOAD LOAD LOAD

9 + V EXT
17 DO 4 18 DO 5 19 DO 6 20 CIO

CIO: COMMON I/O

CIO: COMMON I/O

SETTING THE DIP-SWITCHES

CIO: COMMON I/O

WARNING
The DIP-switch settings are read only at boot time. At each change, perform a restart. For use and settings via DIP-SWITCH SW1 see the user manual available on the website on the web page dedicated to the product.
SW2 DIP SWITCH SETTING: (Z- PASS2-RT-S ONLY):

Through DIP SWITCH SW2 it is possible to select RS485 or

CAN communication through the IDC10 connector:

ON

SW2

KEY

OFF

ON

RS485 ACTIVATION

ON

OFF

CAN ACTIVATION

OFF

MI00612-4-EN

INSTALLATION MANUAL

4/4

