User Manual for JUNG models including: 2023, Switch Range Configurator App, Switch, Range Configurator App, Configurator App, App

Gion Pres-Eßbach Albrecht JUNG

Téléchargement du manuel d'utilisation [EN]

Les solutions JUNG en Building Information Modeling

Range Configurator in Autodesk Revit

Electrical planning with the JUNG Switch Range Configurator in Autodesk Revit

PDF preview unavailable. Download the PDF instead.

2023 Manual JUNGSwitchConfigurator EN
Electrical planning with the JUNG Switch
Range Configurator in Autodesk Revit
TUTORIAL

The JUNG Switch Range Configurator - User manual
The BIM objects for Revit® with LOD 100 and 350 support the creation of intelligent 3D models of buildings for the preparation of construction documentation. The planning and documentation solution covers all phases of a construction project.
Your advantages
Frames and inserts can easily be put together in the clear user interface. The product combinaon is made available in the soware as a complete object. Any non-compable combinaons are excluded by means of a logic test. Changes to visible design components via the menu can be seen at the same me in all layout illustraons. Finally you have the opon to generate the precise number of units and order lists directly from the soware
Create switch combinaon
Aer successful installaon, the JUNG Switch Range Configurator can be accessed via the Add-Ins in Autodesk Revit. Aer clicking on the JUNG applicaon, select the Define new Combination opon.
Now select the appropriate switch programme for your planning. At this point, you determine both the alignment and the material of the frame. You also select whether it is a single or mulple combinaon. Then click on Define inserts.

First define the required cover. You determine the insert behind it via the menu item Select insert. If you have previously selected a mulple frame, change the element to be configured via the Selected centre plate menu item.
Use the Installation height value to determine the height on the selected level. The value specified here is only transferred to the family if the family is placed in the floor plan. If the family is placed in the wall view or perspecve view, the height targeted by the cursor applies. The installaon height can also be adjusted aerwards. Deacvate the Place on wall opon to place the combinaon independently of walls. Click on the Create family buton to create the combinaon. Aer a short wait, you can insert the family of the combinaon into your planning.
The combinaon family created here has a level of detail geared towards the design process. You can find more informaon on the level of information and geometry in the LODs - switch combinaons chapter.
Spling combinaons into arcles
To make it easy to issue invitaons to tender with the arcles used, there is an opon in the menu of the JUNG Switch Range Configurator to Explode Combinations. When you are ready in your planning, you can use this funcon to break down all selected JUNG combinaon families into their arcles. If no family is selected, this is done for all combinaon families in the planning stage.

The advantage of this funcon is that the complexity contained in the combinaon families only flows into the planning when the informaon becomes relevant for the execuon. The individual arcles now available enable the simple creaon of component lists with the product properes relevant for the tender.
The families are created in groups so that you do not make any mistakes when making planning adjustments - be it deleng or moving geometries of the now individually available items. You can find out exactly how the split families are organised in the chapter LODs - grouped families.
LODs
The switch combinations (compact JUNG Revit-family) LoI The LoI of the Revit family is low - in order to keep the design and planning process as simple as possible, a combinaon of the various arcles (i.e. frame, insert and cover) is created in the first step. As the JUNG product porolio, and therefore also the configurator, allows up to 5-fold combinaons, the family created is equipped with the most necessary informaon for the design.
Atenon: The Elevation from level parameter does not represent the installaon height in accordance with DIN 18015-3. To calculate the actual installaon height, the combinaons contain the installaon height distance parameter. This must be added to the Height from level parameter to obtain the actual installaon height.

LoG The electrical symbols for the funcons of the created combinaon are displayed in the floor plan. The distance from the wall is an object parameter and can be moved both via the properes and directly in the drawing (via the arrow symbols). This has the advantage that the creaon of overlapping combinaons does not lead to the symbols overlapping.
The geometric body is displayed both in the floor plan, in the wall view and in the 3D view. There are two levels of detail - coarse, in which only the outline of the frame is displayed, and fine and medium, in which the essenal details of the frames and covers can be recognised. The display of the insert has been completely omited. Single articles (grouped Revit-families) LoI The informaon content of the Revit families increases as they are broken down into items. The individual families contain essenal informaon about the product as well as tender texts and classificaons required for the BIM process, such as OmniClass, UniClass and, last but not least, IFC. This makes an OpenBIM process possible.
LoG Geometrically, the individual families appear idencal to the combinaon families. The electrical symbols can be seen in the floor plan and the frames and covers of the JUNG families in all views. The degrees of fineness also correspond to the combinaon items. Now, in contrast to before, the arcles are individual families. However, they are summarised as a group so as not to lose their interdependence.

A substute geometry for the inserts has been added in order to display all the necessary informaon for the JUNG arcles. On the one hand, this simple cube enables the user to display the insert informaon in the component lists, and on the other hand, the 3-dimensional representaon makes it possible to transfer the informaon for use in other CAD systems. The insert geometry also has an electrical connector so that it can be properly integrated into the electrical planning.

ChangeLog

Version No. V2 V2 V2 V2 V2 V2
V2 V2 V2 V2 V2 V2

Changes
Two-stage creaon system for switch combinaons Preset installaon height instead of wall distance Customisaon of family designaon Movable DIN symbols in the floor plan Simplified visualisaon of the insert geometry New products
· New system: JUNG HOME · New devices: LS TOUCH · New switch range: LS 1912 Link to the JUNG online catalogue Classificaon according to IFC, OmniClass, UniClass, ETIM 8 Supplement Features Inclined rockers Customised user interface Menu Version update Revit 2024

Common quesons- suggested soluons
Q1: I don't see the electrical symbol in the floor plan 1. check in the properes of the plan whether the family used is below the seconal plane 2. check whether the visibility of the "Electrical installaons" model category is acvated.

1

2

3. check whether you have entered the value in millimetres for the installaon height parameter when creang the combinaon family Q2: If I place a horizontal combination family on a rounded wall and disassemble the family with the JUNG Switch Range Configurator, the 3D geometry and the symbols are not positioned correctly. Is there a way to prevent this? Yes, to display the combinaon correctly, it is advisable to place a straight wall parallel to the tangent of the wall at the corresponding point before posioning. So do not place the family on the round wall, but on the straight wall.
Family placed directly on a round wall
Family placed on a straight wall
Q3: I am working with a referenced architecture model and cannot place the models in the project. How can I deal with this? To place the combinations on surfaces that are not walls, you must deselect the option Create on wall when creating the combination family. This enables placement in a 3D view.

Q4: When I try to generate a combination family, I get an error and the family is not created.
This error can have various causes. Basically, it can be said that the data basis does not match. Delete the JungProductConfigurator folder and the JungProductConfigurator.addin file in the following folder paths: C:\ProgramData\Autodesk\Revit\Addins\[Your Revit-Versions] C:\Users\[username]\AppData\Roaming\Autodesk\Revit\Addins\[Your Revit-Versions] Then install the configurator again. If you sll have problems, please contact bim@jung.de.
Contact
If you have any quesons or suggesons, please contact bim@jung.de.


Gion Pres-Eßbach Adobe PDF Library 23.6.156