User Guide for unitronics models including: JZ20-R10-JZ20-J-R10 PLC Controllers, JZ20-R10-JZ20-J-R10, PLC Controllers, Controllers

UG JZ20-R1X R16HS

DOC13028-A0 10/14

Ayelet Gvily

Technical library- about PLC Controllers, HMI panels, automation & control

Jazz User Guide - Unitronics

6 feb 2023 — Danger. The identified danger causes physical and property damage. Warning. The identified danger could cause physical and property damage. Caution. Caution.


File Info : application/pdf, 12 Pages, 807.05KB

PDF preview unavailable. Download the PDF instead.

UG JZ20-R1X R16HS
Jazz®
JZ20-R10/JZ20-J-R10 JZ20-R16/JZ20-J-R16
JZ20-J-R16HS

User Guide
 6 Digital Inputs including 2 HSC, 4 Relay Outputs  6 Digital Inputs including 2 HSC, 2 Analog/Digital Inputs,
2 Analog Inputs, 6 Relay Outputs
 6 Digital Inputs including 3 HSC/Shaft-encoder,
2 Analog/Digital Inputs, 2 Analog Inputs, 6 Relay Outputs

General Description

The products listed above are micro-PLC+HMIs, rugged programmable logic controllers that comprise built-in operating panels.
Detailed Installation Guides containing the I/O wiring diagrams for these models, technical specifications, and additional documentation are located in the Technical Library in the Unitronics website: https://unitronicsplc.com/support-technical-library/

Alert Symbols and General Restrictions

When any of the following symbols appear, read the associated information carefully.

Symbol

Meaning

Description

Danger

The identified danger causes physical and property damage.

Warning

The identified danger could cause physical and property damage.

Caution

Caution

Use caution.

 Before using this product, the user must read and understand this document.  All examples and diagrams are intended to aid understanding, and do not guarantee operation.

Unitronics accepts no responsibility for actual use of this product based on these examples.  Please dispose of this product according to local and national standards and regulations.  Only qualified service personnel should open this device or carry out repairs.

 Failure to comply with appropriate safety guidelines can cause severe injury or property

damage.

 Do not attempt to use this device with parameters that exceed permissible levels.  To avoid damaging the system, do not connect/disconnect the device when power is on.

Environmental Considerations
 Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration, in accordance with the standards given in the product's technical specification sheet.
 Do not place in water or let water leak onto the unit.  Do not allow debris to fall inside the unit during installation.
 Ventilation: 10mm space required between controller's top/bottom edges & enclosure walls.  Install at maximum distance from high-voltage cables and power equipment.

Unitronics

1

Mounting
Note that figures are for illustrative purposes only. Dimensions

Installation Guide

* * Note that for JZ20-J modules those dimensions are 7.5 mm (0.295").

Model

Cut-out

View area

JZ20-xxx\JZ20-J-xxx

117 x 89mm (4.606"x 3.504")

66 x 19.2mm (2.598"x 0.755")

Add-on modulesAvailable by separate order for communication and cloning.

Integral USB Port This may be used for programming purposes.

Note: the USB port and an Add-on module cannot be physically connected at the same time.

Add-on: during installation

Add-on: after installation

USB Port

Installing an Add-on module requires sufficient clearance space

72 mm (2.835")

27.5 mm (1.083")

35.8 mm 38 mm (1.409") (1.496")

DIN-rail mounting Snap PLC onto the DIN rail

Panel mounting

Note: Removing the unit requires clearance space. Recommendation: approximately 40mm (1.58")

2

Unitronics

Jazz®

Wiring

 Do not touch live wires.

Caution

 This equipment is designed to operate only in SELV/PELV/Class 2/Limited Power environments.
 All power supplies in the system must include double insulation. Power supply outputs must be rated as SELV/PELV/Class 2/Limited Power.
 Do not connect either the `Neutral or `Line' signal of the 110/220VAC to device's 0V pin.  All wiring activities should be performed while power is OFF.  Use over-current protection, such as a fuse or circuit breaker, to avoid excessive currents
into the power supply connection point.  Unused points should not be connected (unless otherwise specified). Ignoring this
directive may damage the device.  Double-check all wiring before turning on the power supply.
 To avoid damaging the wire, do not exceed a maximum torque of: - Controllers offering a terminal block with pitch of 5mm: 0.5 N·m (5 kgf·cm). - Controllers offering a terminal block with pitch of 3.81mm f 0.2 N·m (2 kgf·cm).
 Do not use tin, solder, or any substance on stripped wire that might cause the wire strand to break.
 Install at maximum distance from high-voltage cables and power equipment.

Wiring Procedure
Use crimp terminals for wiring; - Controllers offering a terminal block with pitch of 5mm: 26-12 AWG wire (0.13 mm2 ­3.31 mm2). - Controllers offering a terminal block with pitch of 3.81mm: 26-16 AWG wire (0.13 mm2 ­ 1.31 mm2). 1. Strip the wire to a length of 7±0.5mm (0.270­0.300"). 2. Unscrew the terminal to its widest position before inserting a wire. 3. Insert the wire completely into the terminal to ensure a proper connection. 4. Tighten enough to keep the wire from pulling free.
Wiring Guidelines
 Use separate wiring ducts for each of the following groups: o Group 1: Low voltage I/O and supply lines, communication lines. o Group 2: High voltage Lines, Low voltage noisy lines like motor driver outputs. Separate these groups by at least 10cm (4"). If this is not possible, cross the ducts at a 90°angle.
 For proper system operation, all 0V points in the system should be connected to the system 0V supply rail.
 Product-specific documentation must be fully read and understood before performing any wiring. Allow for voltage drop and noise interference with input lines used over an extended distance. Use wire that is properly sized for the load.

Earthing the product

To maximize system performance, avoid electromagnetic interference as follows:  Use a metal cabinet.  Connect the 0V and functional ground points (if exist) directly to the earth ground of the system.  Use the shortest, less than 1m (3.3 ft.) and thickest, 2.08mm² (14AWG) min, wires possible.

Unitronics

3

Installation Guide
UL Compliance
The following section is relevant to Unitronics' products that are listed with the UL. The following models: JZ20-R10,JZ20-J-R10,JZ20-R16,JZ20-J-R16,JZ20-J-R16HS, JZ20-R31, JZ20-J-R31,JZ20-J-R31L,JZ20-T10,JZ20-J-T10,JZ20-T18,JZ20-J-T18,JZ20-J-T20HS,JZ20-T40, JZ20-J-T40,JZ20-UA24, JZ20-J-UA24, JZ20-UN20,JZ20-J-UN20, JZ20-J-ZK2. are UL listed for Ordinary Location.
UL Ordinary Location In order to meet the UL ordinary location standard, panel-mount this device on the flat surface of Type 1 or 4 X enclosures
Panel-Mounting For programmable controllers that can be mounted also on panel, in order to meet the UL Haz Loc standard, panel-mount this device on the flat surface of Type 1 or Type 4X enclosures.
Communication and Removable Memory Storage When products comprise either USB communication port, SD card slot, or both, neither the SD card slot nor the USB port are intended to be permanently connected, while the USB port is intended for programming only. Removing / Replacing the battery When a product has been installed with a battery, do not remove or replace the battery unless the power has been switched off, or the area is known to be non-hazardous. Please note that it is recommended to back up all data retained in RAM, in order to avoid losing data when changing the battery while the power is switched off. Date and time information will also need to be reset after the procedure.
UL des zones ordinaires: Pour respecter la norme UL des zones ordinaires, monter l'appareil sur une surface plane de type de protection 1 ou 4X
Montage de l'écran: Pour les automates programmables qui peuvent aussi être monté sur l'écran, pour pouvoir être au standard UL, l'écran doit être monté dans un coffret avec une surface plane de type 1 ou de type 4X. Communication et de stockage amovible de mémoire (carte mémoire) Produits comprend un port USB de communication, soit un port carte SD ou les deux, ni le port SD, ni le port USB ne sont censés être utilisés en permanence, tandis que l'USB est destiné à la programmation uniquement. Retrait / Remplacement de la batterie Lorsqu'un produit a été installé avec une batterie, retirez et remplacez la batterie seulement si l'alimentation est éteinte ou si l'environnement n'est pas dangereux.
Veuillez noter qu'il est recommandé de sauvegarder toutes les données conservées dans la RAM, afin d'éviter de perdre des données lors du changement de la batterie lorsque l'alimentation est coupée. Les informations sur la date et l'heure devront également être réinitialisées après la procédure

4

Unitronics

Jazz®
Inputs
1. All the products comprise I0-I5; these digital inputs are arranged in a single group. Via wiring, the entire group may be set to either pnp or npn.
2. The following information concerns JZ20-R10/JZ20-J-R10 and JZ20-R16/JZ20-J-R16: I0 and I1 can function as high-speed counters or as normal digital inputs.
3. The following information concerns JZ20-J-R16HS:  I0, I1, and I4 can function as high-speed counters, as part of a shaft-encoder, or as normal digital inputs.  I2, I3, and I5 can function as either counter reset, as part of a shaft-encoder, or as normal digital inputs.  If I0, I1, I4 are set as high-speed counters (without reset), I2, I3, I5 can function as normal digital inputs.
4. The following information concerns JZ20-R16/JZ20-J-R16 and JZ20-J-R16HS in addition to I0-I5, these comprise the following:
I6 and I7 may be wired as either digital or analog inputs. These may be wired as either:  npn digital inputs  pnp digital inputs  analog (voltage) inputs
In addition, one input may be wired as a pnp input, while the other is wired as an analog input. Note that if one input is wired as an npn input, the other may not be wired as an analog input.
5. The following information concerns JZ20-R16/JZ20-J-R16 and JZ20-J-R16HS: AN0 and AN1 are analog (current) inputs.

Unitronics

5

Digital Inputs, Controller's Power Supply
JZ20-R10/JZ20-J-R10 Input wiring (I0-I5), npn (sink)

Installation Guide
Input wiring (I0-I5), pnp (source)

JZ20-R16/JZ20-J-R16
Note: The inputs are arranged in two groups. You can wire one group as npn and the other as pnp, or wire both groups as npn, or as pnp. In either case, the n/p pins must be connected.

Input wiring (I0-I5), npn (sink)

Input wiring (I0-I5), pnp (source)

Input wiring (I6-I7), npn (sink)

Input wiring (I6-I7), pnp (source)

JZ20-J-R16HS
Note: The inputs are arranged in two groups. You can wire one group as npn and the other as pnp, or wire both groups as npn, or as pnp. In either case, the n/p pins must be connected.

Input wiring (I0-I5), npn (sink)

Input wiring (I0-I5), pnp (source)

Input wiring (I6-I7), npn (sink)
6

Input wiring (I6-I7), pnp (source)
Unitronics

Jazz®

HSC input wiring, npn (sink)

HSC input wiring, pnp (source)

Shaft-encoder wiring, npn (sink)

Shaft-encoder wiring, pnp (source)

Digital Outputs
JZ20-R10/JZ20-J-R10

JZ20-R16/JZ20-J-R16/JZ20-J-R16HS Output wiring

Unitronics

7

Installation Guide
Increasing contact life span To increase the life span of your contacts and protect the unit from potential damage by reverseEMF, connect:
 A clamping diode in parallel with each inductive DC load  An RC snubber circuit in parallel with each inductive AC load

JZ20-R10/JZ20-J-R10

JZ20-R16/JZ20-J-R16/JZ20-J-R16HS

Analog inputs
Note: Shields should be connected at the signal source. Analog Input wiring, current (JZ20-R16/JZ20-J-R16 and JZ20-J-R16HS only)

2 or 3-wire (AN0-AN1)

4-wire (AN0-AN1)

Analog Input wiring, voltage Note: If either I6 or I7 is wired as an npn digital input, the remaining input may not be wired as an analog input.
JZ20-R16/JZ20-J-R16/JZ20-J-R16HS (AN2-AN3)

8

Unitronics

Jazz®

Technical Specifications

Power supply Input voltage Permissible range Current Consumption
Max. current consumption Typical power consumption

24VDC

20.4-28.8VDC with less than 10% ripple

See Note 1

JZ20-R10/JZ20-J-R10

JZ20-R16/JZ20-J-R16/JZ20-J-R16HS

120mA@24VDC

136mA@24VDC

2.4W

2.6W

Notes:

1. To calculate the actual power consumption, subtract the current for each unused relay output and LCD backlight (if unused) from the maximum current consumption value.

Per relay output LCD backlight

Max. current per element

8.3mA@24VDC 35mA@24VDC

Battery Back-up
Digital Inputs Number of inputs
Input type Galvanic isolation Nominal input voltage Input voltage
pnp (source)
npn (sink)
Input current Response time

7 years typical at 25°C, battery back-up for RTC and system data, including variable data.

JZ20-R10/JZ20-J-R10 6 (one group). See Note 1 pnp (source) or npn (sink) None 24VDC

JZ20-R16/JZ20-J-R16/JZ20-J-R16HS
8 (two groups). See Notes 1 & 3

0-5VDC for Logic `0' 17-28.8VDC for Logic `1'

17-28.8VDC for Logic `0' 0-5VDC for Logic `1'

I0-I5

I6-I7

3.7mA@24VDC 1.2mA@24VDC

10mSec typical 20mSec typical

Input cable length

Up to 100 meters, unshielded

High speed inputs

Specifications below apply when wired as HSC/Shaft-encoder. See Notes 4 & 5.

Resolution

16-bit

Frequency

10kHz maximum

Minimum pulse width

40s

Notes:

2. All products comprise I0-I5; these inputs are arranged in a single group. Via wiring, the entire group may be set to either pnp or npn.

3. Only JZ20-R16/JZ20-J-R16 and JZ20-J-R16HS comprises I6 & I7. These may be wired as either digital or analog inputs, as shown in the JZ20-R16/JZ20-J-R16 and JZ20-J-R16HS Micro PLC Installation guide. I6 & I7 may be wired as npn, pnp, or 0-10V analog inputs. 1 input may be wired as pnp, while the other is wired as analog. If 1 input is wired as npn, the other may not be wired as analog.

Unitronics

9

Installation Guide

4. Only in JZ20-R10/JZ20-J-R10 and JZ20-R16/JZ20-J-R16:

· I0 and I1 can each function as either a high-speed counter or as a normal digital input.

· When used as a normal digital input, normal input specifications apply.

5. Only in JZ20-J-R16HS:

· I0, I1, and I4 can function as high-speed counters, as part of a shaft-encoder, or as normal digital inputs.

· I2, I3, and I5 can function as either counter reset, as part of a shaft-encoder, or as normal digital inputs.

· If I0, I1, I4 are set as high-speed counters (without reset), I2, I3, I5 can function as normal digital inputs.

· When used as a normal digital input, normal input specifications apply.

Digital Outputs

Number of outputs

JZ20-R10/JZ20-J-R10

JZ20-R16/JZ20-J-R16/JZ20-J-R16HS

4 relay

6 relay

Output type

SPST-NO (Form A)

Isolation

By relay

Type of relay

Panasonic JQ1AP-24V or compatible

Output current

5A maximum (resistive load)

Rated voltage

250VAC / 24VDC

Minimum load

1mA@5VDC

Life expectancy

50k operations at maximum load

Response time

10mS (typical)

Contact protection Analog Inputs

External precautions required (see Increasing Contact Life Span in the product's Installation Guide)
JZ20-R16/JZ20-J-R16 andJZ20-J-R16HS only

Number of inputs

4, according to wiring as described above in Note 3

AN0 and AN1

AN2 and AN3

Input range

0-20mA, 4-20mA 0-10VDC

Input impedance

154

20K

Maximum input rating

30mA

28.8V

Galvanic isolation Conversion method Resolution Conversion time
Precision Status indication
Input cable length

None Succesive approximation 10 or 12-bit (0 to 4095) (Via Software) All analog inputs are updated every 8 PLC scans, regardless of how many inputs are actually configured.
 2% Yes ­ if an analog input deviates above the permissible range, its value will be 4096. Up to 30 meters, shielded twisted pair

Display Type Illumination backlight
Display size Character size
10

STN LCD LED, yellow-green, software controlled (LCD backlight; enables the display to be viewed in the dark) 2 lines, 16 characters long 5x8 matrix, 2.95x5.55mm
Unitronics

Jazz®

Keyboard Number of keys Key type Slides
Program Ladder code memory Execution time Memory bits (coils) Memory integers (registers), 16 bit Timers HMI displays HMI variables

16 keys, including 10 user-labeled keys Metal dome, sealed membrane switch Slides may be installed in the operating panel faceplate to custom-label the keys and logo picture. An extra logo slide is included. A complete set of blank slides is available by separate order.
48k (virtual) 1.5 µSec for bit operations (typical) 256 256
64 60 user-designed displays available 64 HMI variables are available to conditionally display text and data. List variables add up to 1.5k's worth of HMI capacity.

Communication GSM-support
MODBUS Baud rate USB
Port type Galvanic isolation Specification Baud rate range Cable

Via a built-in USB port or - Add-On module. See Note 6-9 SMS messages to/from 6 phone GSM numbers, up to 1K of userdesigned messages. Supports Remote Access. Supports MODBUS protocol, Master-Slave According to add-on port module
Mini-B No USB 2.0 compliant; full speed 300 to 115200 bps USB 2.0 compliant; up to 3m

Notes: 6.

The JZ20 built-in USB port may be used for programming. Add-on Modules are available by separate order for communication and cloning. Note that the USB port and an Add-on module cannot be physically connected at the same time

7. Add-on module JZ-PRG, with 6-wires communication cable (supplied in PRG kit ­ see the JZ-PRG Installation Guide) can be used: - for programming
- to connect a modem

8. Add-on module JZ-RS4 (RS232/485), with a standard 4-wire communication cable can be used: - for programming - to communicate with other devices (including modems/GSM) - for RS485 networking.

9. Add-on module MJ20-ET1 enables communication over 100 Mbit/s TCP/IP network:
- Programming/data exchange with Unitronics software; - Data exchange via MODBUS TCP as Master or Slave.

Unitronics

11

Installation Guide

Miscellaneous

Clock (RTC)

Real-time clock functions (date and time).

Environmental Operating temperature Storage temperature Relative humidity (RH) Mounting method

0 to 50C (32 to 122F) -20 to 60 C (-4 to 140F) 10% to 95% (non-condensing) Panel mounted (IP65/NEMA4X) DIN-rail mounted (IP20/NEMA1)

Dimensions Size Weight

147.5 x 117 x 46.6mm )5.807" x 4.606" x 1.835"). See Note 10 300 g (10.6 oz)

Notes:

10.

For exact dimensions, refer to the Page 2.

Mounting Panel mounting
DIN-rail mounting

Insert into cut-out: 117 x 89mm (WxH) 4.606"x 3.504" Snap unit onto the DIN rail

The information in this document reflects products at the date of printing. Unitronics reserves the right, subject to all applicable laws, at any time, at its sole discretion, and without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or temporarily withdraw any of the forgoing from the market.
All information in this document is provided "as is" without warranty of any kind, either expressed or implied, including but not limited to any implied warranties of merchantability, fitness for a particular purpose, or non-infringement. Unitronics assumes no responsibility for errors or omissions in the information presented in this document. In no event shall Unitronics be liable for any special, incidental, indirect or consequential damages of any kind, or any damages whatsoever arising out of or in connection with the use or performance of this information.
The tradenames, trademarks, logos and service marks presented in this document, including their design, are the property of Unitronics (1989) (R"G) Ltd. or other third parties and you are not permitted to use them without the prior written consent of Unitronics or such third party as may own them
UG_JZ20-R1X_R16HS.pdf 09/22

12

Unitronics



References

Microsoft Word for Microsoft 365