2 INSTALLATION GUIDE SLD2/CH INSTALLATION GUIDE SLD2/CHPlease keep this instruction manual for future reference Please keep this instruction manual for future reference 3 INSTALLATION GUIDE Thank you for purchasing your Caple tap. These taps have been manufactured and inspected to exacting standards and are guaranteed to give years of trouble


File Info : application/pdf, 3 Pages, 375.49KB

PDF preview unavailable. Download the PDF instead.

SLD2-CH-Installation-guide-1
CHROME TAP CARE, INSTALLATION AND GUARANTEE INFORMATION
MODEL CODE: SLD2/CH
Customer care helpline: 0117 938 1900 www.caple.co.uk

INSTALLATION GUIDE Thank you for purchasing your Caple tap. These taps have been manufactured and inspected to exacting standards and are guaranteed to give years of trouble free operation providing our care and installation guidelines have been followed.
60°C

NOTE: Please see back page for installation instructions
2 INSTALLATION GUIDE SLD2/CH Please keep this instruction manual for future reference

Please keep this instruction manual for future reference INSTALLATION GUIDE SLD2/CH 3

INSTALLATION INSTRUCTIONS
- Turn the spout and body so the tap is facing forwards, the screw on the spout indicates the rear of the body. The hot water connection should be on the left of the tap.
- Ensurethehotandcoldpipesarethoroughlyflushedtoremove any debris.
- A 35mm hole is required in either the sink or worktop. - Thefixingboltmustbescrewedintothetapbase,ensuringthe
threads of the bolt are not damaged in the process. - Passthenylonwasheroverthefixingboltflushtothebottom
of the tap base, then pass the bolt through the sink or worktop (ensuring the nylon washer remains directly under the tap base). - Pass the rubber washer and then the metal washer (on the undersideofthesink/worktop)overthefixingboltandfixusing thefixingnut. - Screwtheflexi-tailpipesintothebaseofthetap,ensuringthe pipesthreadsarenotdamagedintheprocess.Iftheflexi-tails are already inserted into the tap base, please ensure these are screwed in tightly to prevent any leaks. - Finallyconnecttheflexi-tailpipestothehotandcoldsupplies ensuring they are connected to the correct supplies.
CARE OF YOUR TAPS
- Only clean your taps with soap or mild liquid detergent and clean water then dry using a soft cloth
- Do not use chemical cleaners, or bleach based solutionstocleanyourtap,contactcouldaffectthefinishof your tap.
- Do not use abrasive cleaners, liquids, powders or pads. These willdamagethefinishofyourtapandvoidtheguarantee.
- Provided all of the above points are adhered to the surface finishofyourCapleTapisguaranteedfor5years.

PRE INSTALLATION CHECKS - The temperature of the hot water supply must not
exceed 70°C. - Water pressure requirements: minimum required pressure
varies dependent on model, maximum pressure 5 bar. - Alwaysseekadvicefromaqualifiedinstallertoensureyour
installation and water supply to your taps comply with the water regulation (WRAS) requirements and good plumbing practice. - It is good practice to ensure that both hot and cold water supplies to your tap are of an equal pressure to provide a consistentflow.Ifsuppliesarenotofequalpressurethena nonreturnvalveshouldbefittedonthehotinlet. - Supplies of water should be from a common source (mains or tank fed). - We recommend that a service valve is installed in the supply lines to the tap to enable water isolation if required.
POST INSTALLATION POINTS - We suggest when connecting screw connections that PTFE tape
is used before the joints are fully tightened. - Before use correctly check the installation for leaks, and
turnthehotandcoldwaterontothoroughlyflushany small particles that may have been dislodged during the tap installation.
THESE INSTRUCTIONS ARE INTENDED AS A GUIDE,
IF IN ANY DOUBT ENSURE YOU SEEK ADVICE
FROM A CERTIFIED PLUMBER.

GUARANTEE - Your Caple tap is guaranteed for 5 years. - Should you have any defects as detailed above during the appropriate guarantee period we guarantee to repair or replace
the defective products or parts, or, at our option refund the purchase price assuming we were advised immediately of any claim in writing. - It is important that you keep a proof of purchase (such as your receipt) to facilitate your guarantee.
TERMS AND CONDITIONS - Guarantee conditions are only valid if the Care guidelines listed above are followed. - Our obligation under the guarantee is to the original purchaser, and may not be transferred. - The guarantee is valid for UK domestic installations only and relates to defects in manufacture, materials and
workmanship only. - Issues that arise due to normal wear and tear (for example valves, discs or washers), poor installation,
improper use or accidental damage are not covered by the Caple guarantee. Spare parts can be purchased from our Customer care helpline 0117 938 1900. - Noliabilityisacceptedforconsequentialdamagetootherhouseholdfixtures,fittingsorfurnishingsrelating toanyclaim-evenifattachedtotheproduct. - If it is more economically viable a replacement tap will be supplied, this tap might vary from the original design should range changes of occurred since the initial supply. - We reserve the right to inspect any tap before committing to support under the guarantee conditions.