User Manual for Power Technologies models including: CNC-10 Bay Charging and UV-C Sanitizing Cabinet, Bay Charging and UV-C Sanitizing Cabinet, Charging and UV-C Sanitizing Cabinet, UV-C Sanitizing Cabinet, Sanitizing Cabinet, Cabinet
42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual Rev2024-12 4 The CNC-10™ is designed to disinfect and charge tablets and other electronic devices.
File Info : application/pdf, 17 Pages, 4.23MB
DocumentDocumentCNC-10TM 10 BAY CHARGING & UV-C SANITIZING CABINET USER MANUAL Product Information Designed to disinfect and charge tablets and other electronic devices. Specifications: Model CNC-10TM Exterior Dimensions Bay Dimensions Product Weight (Without Devices) Shipping Weight Inch cm Inch cm 19.8 (H) x 19 (W) x 13.75 (D) 50.29 (H) x 48.26 (W) x 34.93 (D) 10 (H) x 14 (W) x 12.5 (D) 25.4 (H) x 35.56 (W) x 31.75 (D) 52 lbs (23.58 kg) 57 lbs (25.85 kg) Capacity 10 Tablets Configurable Interior Supported Devices Power Specifications (For cabinets sold within North America) Power Specifications (For cabinets sold outside North America) Charging Type Max Device Size: 10" x 12.5" (25.4 cm x 31.75 cm) AC IN/ Power Strip: 110V AC, 50/60Hz, 10A Maximum power: 1400W AC IN/ Power Strip: 110-240V AC, 50/60Hz, 10A Maximum power: 2400W USB-C Charging Hub Security Sanitizing Type Bulb Specification Bulb Wattage Lockable via Security Code UV-C Light Sanitization 360° Reach Lamps & Reflective Lining Virtually Eliminate Blind Spots, 254nm mecury based bulb 8 Watts Bulb Life Up to 6000 hours Adapter Shelves Loading (ea.) Working Temperature 6.6 lbs (3 kg) 0°- 30°c Working RH% 10% - 90% Storage Temperature -40°- 60°C Temp Storage RH% 5% - 95% Warranty Lifetime Frame, 2 Years Components, 2 Years Electronics Specifications subject to change without notice. 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 2 Product Information This manual covers the following models and part numbers below. Refer to the part numbers and cord end diagrams for your specific region. Note: The manual is based upon the North American 110V product offering. MODEL# CNC-10TM SKU CAB-CNC-B10K-D CAB-CNC-B10K-E CAB-CNC-B10K-U CAB-CNC-B10K-A CAB-CNC-B10K-S DESCRIPTION CNC-10TM, 10 Bay UV-C Sanitizing & Charging Cabinet - 110V NA CNC-10TM, 10 Bay UV-C Sanitizing & Charging Cabinet - 220V EU CNC-10TM, 10 Bay UV-C Sanitizing & Charging Cabinet - 220V UK CNC-10TM, 10 Bay UV-C Sanitizing & Charging Cabinet - 240V AU CNC-10TM, 10 Bay UV-C Sanitizing & Charging Cabinet - 220V SW Power Cords and Sockets for Specific Region: US / Canada Socket United Kingdom Power Cord Plug Socket European Power Cord Plug Socket Australian Power Cord Plug Socket Switzerland Type-J Power Cord Plug Socket Power Cord Plug 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 3 Product Information The CNC-10TM is designed to disinfect and charge tablets and other electronic devices. Note: Review this guide before installing devices and to learn how to safely use your cabinet. Touchscreen Interface Handle Front View of Cabinet (Closed) 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 4 Product Information Top Panel / USB Hub Removable Service Panel Lock Mechanism & Internal Wiring Carry Handle (Both sides) Removable Medical Grade Stainless Steel Racks Power cord port Front Angled View of Cabinet (Opened) 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 5 Product Information Electromagnetic Lock Door Lock Sensor Power Module Power Cord Rear View of Cabinet (Opened) 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 6 Product Information Lockable Top Panel Area to Secure Power Cables USB-C Hub Ports USB-C Cable Pass-Through Openings USB-C Hub Top View of Cabinet (Opened) 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 7 Product Information Internal Configurations: CNC-10TM comes with two additional racks in addition to the divider base and top rack allowing charging space to be configured to meet device needs. Bottom, Center and Top Rack Device Divider with Bottom and Top Rack Bottom and Top Rack only 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 8 User Instructions Operation and User Interface: To use the CNC-10TM, simply unlock the cabinet door, place the device inside, and connect it to the pre-loaded charging cable. CNC-10TM will charge the device based upon device's settings. Once charged CNC-10TM provides a maintenance charge keeping devices ready for use. UV-C Disinfection Countdown Timer Set Disinfection Time: + or in 1-minute increments Start UV-C Settings Button Stop UV-C Unlock/Lock Cabinet door 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 9 User Instructions Unlock and Lock Cabinet Door: This is done via the control panel. Cabinet is equipped with an electro-magnetic lock that engages while the unit is powered. A mechanical lock release is found in secured side panel for access by administrator. How-To Lock Cabinet · Hit "Lock" icon on control panel. · Prompt will appear saying the following: Lock the cabinet door? Hit "OK" How-To Unlock Cabinet · To unlock, select "Lock" icon again. · Enter password and select "Unlock". · Icon on main screen will show lock as being open. Changing User Password: How-To Change Password · Hit "Settings" icon on control panel. · Select "Change Password" option. · Enter current password. Hit "OK" · Enter new password. Hit "OK" Default Passwords for User and Administrator 1. The factory default user password is 1234, and the user password can be used to unlock and reset the UV lamp usage time; 2. The user password can be modified as well, · The modification method is as follows: enter the old user password or administrator password in the password change page--click OK, enter the new user password--click OK. · The administrator password is fixed to 5482045, and the administrator password can only be used to modify user passwords. 3. If a user forgets his/her password, the administrator can set a new user password with the administrator password. 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 10 Installation Instructions Setting Up USB-C Cables: Group cables together to guide cables through easily. Plug into the USB-C Hub Connect one end of each cable to the appropriate port on the USB-C Hub. Thread through the Pass-Through Carefully guide the bundled cables through the pass-through opening. Tip: If you encounter resistance while feeding the cables, try gently flexing the cables or adjusting the angle of entry. Secure with the Bracket Position the cables so they are held securely by the retaining bracket. The zip ties will add extra tension, ensuring a firm hold. 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 11 Fitting Devices Inside Cabinet Setting Up Devices: Open the door and place devices inside so that all surfaces are completely exposed. To configure racks differently, remove thumb screws from the left/right sides and pull the shelf out. Insert new shelf and replace thumb screws. Place devices in again so that all surfaces are completely exposed. If needed, place less items inside to avoid crowding. Begin Disinfection process. Care and Maintenace: · Keep the cabinet exterior clean with a mild cleaner on a soft cloth for exterior surfaces. · Interior service should be cleaned via compressed air once a month or as needed. · Medical Grade Stainless Steel racks should be wiped down with mild cleaner once a month or as needed. 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 12 Disinfecting Of Devices Overview: Support infection control initiatives with ultraviolet (UV-C) light sanitization to encourage more frequent disinfection without the use of corrosive chemicals. CNC-10TM effectively kills 99.9% of infectious pathogens for various devices. The UV absorbing, transparent window with electromagnetic locking system keeps users safe while devices are being disinfected. Disinfection cycle times, from 3 minutes to 20 minutes, can be customized depending on workflow and efficacy needs. CNC-10TM customizable charging for up to 10 electronic devices. Designed with the highest level of flexibility and versatility in mind, CNC-10TM offers the ability to configure medical grade stainless steel racks to adapt to devices of varying shapes and sizes. Integrated cable management and lockable power adapter storage area keep cables organized and secure. Disinfect: · Medical Grade Stainless Steel Racks. · Chemical-free UV-surface disinfection process. · Sanitizes Exposed Surfaces. · Locker Power Adapter Storage Area with Removable Top Panel. · Effectively kill 99.9% of infectious pathogens like influenza, the common cold and coronavirus. · 360° reach eight lamps and reflective lining Virtually Eliminate Blind Spots. · Customizable disinfection cycle times. · Integrated Cable Management. 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 13 Determining Time The following list is provided as a guide of which organisms become deactivated within 3 minutes: Bacteria Bacillus anthracis B. megatherium sp. (spores) B. megatherium sp. (veg.) B. parathyphosus B.suptilis B. suptilis spores Campylobacter jerjuni Clostridium tetani Corynebacterium diphteriae Dysentery bacilli Eberthella typhosa Escherichia coli Klebsiella terrifani Legionella pneumophila Micrococcus candidus Micrococcus sphaeroides Mycobacterium tuberculosis Neisseria catarrhalis Phytomonas tumefaciens Pseudomonas aeruginosa Pseudomonas fluorescens Proteus vulgaris Salmonella enteritidis Salmonella paratyphi Salmonella typhimurium Sarcina lutea Seratia marcescens Shigella paradysenteriae Shigella sonnei Spirillum rubrum Staphylococcus albus Staphylococcus aureus Streptococcus faecalis Streptococcus hemoluticus Streptococcus lactus Streptococcus viridans Sentertidis Vibrio chlolerae (V.comma) Yersinia enterocolitica Yeasts Bakers' yeast Brewers' yeast Common yeast cake Saccharomyces cerevisiae Saccharomyces ellipsoideus Saccharomyces sp. Mould Spores Aspergillus flavus Aspergillus glaucus Aspergillus niger Mucor racemosus A Mucor racemosus B Oospora lactis Penicillium digitatum Penicillium expansum Penicillium roqueforti Rhizopus nigricans Viruses Hepatitis A Influenza virus MS-2 Coliphase Polio virus Rotavirus Additional time settings may be needed for other organisms not listed. Note: This UV-C product is not approved and/or certified as a medical device. 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 14 Bulb Life & Replacement CAUTION: UV Lamps contain mercury - manage in accordance with your local disposal laws. A lamp breaking is extremely unlikely to have any impact on your health. If a lamp breaks, ventilate the room for 30 minutes and remove the parts, preferably with gloves. Put them in a sealed plastic bag and take it to your local waste facilities for recycling. Do not use a vacuum cleaner. For maximum efficiency, change bulbs when one no longer works or more than 6,000 hours. With your unit unplugged from an electrical outlet, open the door. Remove the thumbscrews from the left side and pull the upper, middle & lower shelves out. Wearing cotton gloves, rotate the old bulb counter clockwise to release it from the lamp socket. Install new bulb by placing into lamp socket and rotating clockwise until you hear a click. Plug the unit back into an electrical outlet and reset the Bulb Use Hours counter by following the instructions below. How-To Reset Bulb Usage · Hit "Settings" icon on control panel. · Select "Reset Bulb Usage" option. · Enter current password. Hit "Reset" NOTE: Cabinet door will not unlock during UV-C disinfection. Press stop to end UV-C disinfection to activate the lock button. 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 15 Safety Instructions Caution Notice DO NOT place liquids on or near the cabinet. THIS IS NOT A TOY. ALWAYS FOLLOW SAFETY INSTRUCTIONS. Important Danger Warning Don't connect the cart with broken electrical components. THE ELECTRICAL SYSTEM IS DESIGNED TO HANDLE A MAXIMUM OF 1400 WATTS per side. If wattage exceeds 1400W at one time, charging system may not operate correctly. Remove devices until the total wattage is under 1400W. · ALWAYS move the cabinet slowly and be aware of our surroundings. · Used or broken bulbs should be disposed of in accordance with all applicable disposal laws. · Repairs should always be performed by a qualified electrician. · Set the power switch to the OFF position before you unplug the unit from the wall, plug the unit into the wall, or plug in devices. · Do not touch bulbs or ballasts. · Do not alter the construction or design. Do not remove safety labels or devices. · Do not use this product around flammable or combustible materials. DO NOT block fan or vent opening This UV-C product is not approved and/or certified as a medical device. DO NOT touch any part of the electrical system while plugged in. For warranty claims, please have the following information ready, then visit www.powertechnologies.com to create a help ticket. DO NOT use an extension cord with this unit. Serial Number: -----------------------------------------------------------Charging System Type: DO NOT allow children to move or climb. -----------------------------------------------------------Date Of Purchase: Ultraviolet light. Avoid eye and skin -----------------------------------------------------------Reseller Name: -----------------------------------------------------------PO Number: DO NOT over extend the power cord ------------------------------------------------------------ 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 16 Further Information For further information on this product and others, contact Power Technologies at. Power Technologies 42035 Zevo Dr Temecula, CA 92590 888.650.4488 support@powertechnologies.com www.powertechnologies.com 42035 Zevo Drive Temecula, CA 92590 | 888-650-4488 | www.powertechnologies.com PT CNC-10 User Manual_Rev2024-12 17