User Manual for lumiring models including: V3.0 Five Wire, AIR-B Access Control and Wireless Wiegand, AIR-B, Access Control and Wireless Wiegand, Wireless Wiegand, Wiegand
3 Introduction This document provides detailed information on the structure of the device as well as the steps to install and connect it. It also includes instructions for preventing or troubleshooting many common problems.
Introduction. •. Device Specifications. •. Device Settings. •. Device Dimensions. •. Wire Designation. •. Installation Recommendations.
File Info : application/pdf, 14 Pages, 922.96KB
DocumentDocument2025-02-18 V 3.1 MANUAL AIR-B (V3.0 Five Wire) CONTENTS · Introduction 3 · Device Specifications 4 · Default Device Settings 4 · Device Dimensions 5 · Wire Designation 6 · Installation Recommendations Placement and connection 7 Wiring 7 Functionality and setup 7 Precautions and maintenance 7 · Structure of the Setup Menu 8 · Connection Diagram: Connection to the ICON-Pro Controller 9 Connection to the ICON Controller 10 Connection to the AIR-CR Controller 11 Connection to the Magnetic Lock 12 · Hardware Reset 13 · For Notes 14 AIR-B 2 Introduction This document provides detailed information on the structure of the device as well as the steps to install and connect it. It also includes instructions for preventing or troubleshooting many common problems. This guide is for informational purposes only, and the actual product takes precedence in case of any discrepancies. All instructions, software, and functionality are subject to change without prior notice. The latest version of the manual and additional documentation can be found on our website or by contacting customer support. The user or installer is responsible for complying with local laws and privacy regulations when collecting personal data while using the product. FCC Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. AIR-B 3 Device Specifications Voltage: · 12 or 24 VDC operation · 0.11A @12 VDC, 0.055A @ 24 VDC current consumption Outputs: · One output (open collector) 0.2A @ 12 VDC Inputs: · One input (dry contact type) from 0 to 5 volts Sensor type: · Laser Distance: · 4", 8", 12" or 20" (10, 20, 30, 50 cm) Indication: · Two color LEDs, buzzer Default Device Settings Distance: · 4" (10 cm) Delay: · 0.1 second Open delay: · 0.1, 3, 6 or 9 seconds Dimensions (D x H): · 2.36" x 0.67" (60 x 17 mm) · 2.36" x 0.86" (60 x 22 mm) mounting ring Mounting method: · Wall mount Weight: · 1.59 oz (45 g) Operation temperature: · -22°F ~ 158°F (-30°C ~ 70°C) Ingress protection rating: · IP 65 AUX GND (work mode): · NO Buzzer: · Enable AIR-B 4 Device Dimension 2.125" 125, 65535 3.375" 2.36" 0.67" 0.08" 0.2" Front view Side view Thin mounting ring Thick mounting ring 1.15" 1.61" Mounting ring front view AIR-B Standard RFID card size 2.91" 1.15" L Optional accessory 5 4.72" 1.61" Wire Designation Red Black Yellow Green Blue +VDC GND AUX Out Reserved G LED AIR-B (V3.0 Five Wire) Red Black Blue Green +VDC GND AUX Out G LED AIR-B (V2.0 Four Wire) AIR-B 6 Installation Recommendations Placement and connection: · Choose a location for the button that minimizes possible interference from nearby objects or surfaces. · Do not place the button in locations where accidental actuation may occur, such as near moving objects or in high-traffic areas. · Do not place the button in direct sunlight. Sunlight may cause false triggering. · Ensure that the button is positioned at the optimum height for ease of use and detection sensitivity. Wiring: · Make all connections with the power off. If it is necessary to control devices with current consumption more than 0.2A @ 12 VDC, use a separate external relay. · Connect the G LED wire to the reader as shown in the wiring diagrams to synchronize the reader indication with the button indication. Functionality and setup: · Before connecting the electric lock, configure parameters such as control output activity duration and initial state (NO/NC). · When setting sensitivity, determine the balance between button sensitivity and false alarm prevention. Increasing sensitivity may increase the probability of triggering under undesirable conditions, while decreasing sensitivity may result in incomplete response to desired influences. Precautions and maintenance: · The unit requires no special maintenance if the installation instructions are followed. · If the laser sensor is dirty or an obstacle is detected, the unit will activate a light and sound an alarm. · In case of contamination, gently clean the surface of the button, first with a damp cloth and then with a dry cloth. AIR-B 7 Structure of the Setup Menu Distance Open Delay AUX GND Mode Buzzer 3.93" (10 cm) 0.1 seconds NC (normally closed) Disable 7.88" (20 cm) 3 seconds NO (normally open) Enable 11.81" (30 cm) 6 seconds 19.68" (50 cm) 9 seconds Mode Select AIR-B 8 Connection Diagram Connection to the ICON-Pro Controller Red Black Yellow Green Blue +VDC GND AUX Out Reserved G LED AIR-B (V3.0 Five Wire) AIR-B USB LED POWER DOOR 2 TYPE-C 15.4W LAN PoE+ STATUS NETWORK ICON-PRO ACCESS CONTROLLER WIEGAND 2 GND 12/24 CONT. 2 GND REX 2 +VDC GND BUZZER G LED D 1 D 0 CONT. 1 GND REX 1 +VDC GND BUZZER G LED D 1 D 0 WWW.LUMIRING.CO DOOR 1 WIEGAND 1 ICON-Pro 9 Connection Diagram Connection to the ICON Controller Red Black Yellow Green Blue +VDC GND AUX Out Reserved G LED AIR-B (V3.0 Five Wire) AIR-B WWW.LUMIRING.COM POWER WIEGAND 1 NETWORK ICON ACCESS CONTROLLER WIEGAND 2 OSDP DOOR 1 AUX GND 12/24 POWER Wi-Fi LAN A FUSE WET MODE GND B REX 1 GND CONT. 1 +VDC DOOR 2 RELAY WET +VDC OUT GND NC C NO 15.4W LAN PoE+ ICON Connect the blue wire coming from the proximity button to the LED pin of the Wiegand port. 10 Connection Diagram Connection to the AIR-CR Controller Red +VDC Black Orange GND G LED Blue EXIT AIR-CR +VDC GND EXIT G LED AIR-B (V3.0 Five Wire) Red Black Yellow Blue · The wire colors of the cable connecting the controller to the proximity button may vary in reality, and are given as an example. AIR-B 11 Connection Diagram Connection to the Magnetic Lock Red Black Yellow Green Blue +VDC GND AUX GND AIR-B (V3.0 Five Wire) · Specify the NC (normaly close) type in the AUX GND mode settings to control the magnetic lock. · Specify the NO (normaly open) type in the AUX GND mode settings to control the electric latch. Warning Use Correct Polarity! Magnetic Lock MAX 200 mA · A protective diode is used to protect the devcie from reverse currents when an electromagnetic or electromechanical lock is triggered. · The protective diode is connected in parallel with the contacts of the lock. · THE DIODE IS CONNECTED IN REVERSE POLARITY. · The diode must be installed directly on the contacts of the lock. Suitable diodes include SR5100, SF18, SF56, HER307, and similar. · Instead of diodes, varistors 5D330K, 7D330K, 10D470K, or 10D390K can be used, for which there is no need to observe polarity. AIR-B 12 Hardware Reset Mode Select Hardware reset 1. Make sure that the device is connected to a power source. 2. Press and hold the "Mode" and "Select" buttons simultaneously. 3. Wait for the device to emit one short beep and a long beep for 5 seconds. 4. Release the buttons immediately after the beep ends. 5. Disconnect the unit from the power source and reconnect it. 6. The hardware reset is complete. The device is ready for operation. AIR-B 13 For Notes AIR-B 14