User Manual for lumiring models including: V3.0 Five Wire, AIR-B Access Control and Wireless Wiegand, AIR-B, Access Control and Wireless Wiegand, Wireless Wiegand, Wiegand

20250218 AIR B Manual EN V3.1

Lumiring

V 3.1 MANUAL - lumiring.com

3 Introduction This document provides detailed information on the structure of the device as well as the steps to install and connect it. It also includes instructions for preventing or troubleshooting many common problems.

[PDF] MANUAL - Lumiring

Introduction. •. Device Specifications. •. Device Settings. •. Device Dimensions. •. Wire Designation. •. Installation Recommendations.


File Info : application/pdf, 14 Pages, 922.96KB

PDF preview unavailable. Download the PDF instead.

20250218 air b manual en v3.1
2025-02-18 V 3.1
MANUAL
AIR-B
(V3.0 Five Wire)

CONTENTS

· Introduction

3

· Device Specifications

4

· Default Device Settings

4

· Device Dimensions

5

· Wire Designation

6

· Installation Recommendations

 Placement and connection

7

 Wiring

7

 Functionality and setup

7

 Precautions and maintenance

7

· Structure of the Setup Menu

8

· Connection Diagram:

 Connection to the ICON-Pro Controller

9

 Connection to the ICON Controller

10

 Connection to the AIR-CR Controller

11

 Connection to the Magnetic Lock

12

· Hardware Reset

13

· For Notes

14

AIR-B

2

Introduction
This document provides detailed information on the structure of the device as well as the steps to install and connect it.
It also includes instructions for preventing or troubleshooting many common problems. This guide is for informational purposes only, and the actual product takes precedence in case of any discrepancies.
All instructions, software, and functionality are subject to change without prior notice. The latest version of the manual and additional documentation can be found on our website or by contacting customer support.
The user or installer is responsible for complying with local laws and privacy regulations when collecting personal data while using the product.
FCC Statement
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

AIR-B

3

Device Specifications
Voltage: · 12 or 24 VDC operation · 0.11A @12 VDC, 0.055A @ 24 VDC
current consumption Outputs: · One output (open collector) 0.2A @ 12
VDC Inputs: · One input (dry contact type) from 0 to 5
volts Sensor type: · Laser Distance: · 4", 8", 12" or 20" (10, 20, 30, 50 cm) Indication: · Two color LEDs, buzzer
Default Device Settings
Distance: · 4" (10 cm) Delay: · 0.1 second

Open delay: · 0.1, 3, 6 or 9 seconds Dimensions (D x H): · 2.36" x 0.67" (60 x 17 mm) · 2.36" x 0.86" (60 x 22 mm) mounting ring Mounting method: · Wall mount Weight: · 1.59 oz (45 g) Operation temperature: · -22°F ~ 158°F (-30°C ~ 70°C) Ingress protection rating: · IP 65
AUX GND (work mode): · NO Buzzer: · Enable

AIR-B

4

Device Dimension

2.125"

125, 65535
3.375"

2.36"

0.67"

0.08"

0.2"

Front view
Side view Thin mounting ring Thick mounting ring
1.15"
1.61"
Mounting ring front view
AIR-B

Standard RFID card size
2.91"
1.15"
L
Optional accessory
5

4.72"

1.61"

Wire Designation

Red Black Yellow Green Blue

+VDC GND AUX Out Reserved G LED

AIR-B
(V3.0 Five Wire)

Red Black Blue Green

+VDC GND AUX Out G LED

AIR-B
(V2.0 Four Wire)

AIR-B

6

Installation Recommendations
Placement and connection: · Choose a location for the button that minimizes possible interference from nearby objects or
surfaces. · Do not place the button in locations where accidental actuation may occur, such as near moving
objects or in high-traffic areas. · Do not place the button in direct sunlight. Sunlight may cause false triggering. · Ensure that the button is positioned at the optimum height for ease of use and detection
sensitivity. Wiring: · Make all connections with the power off. If it is necessary to control devices with current
consumption more than 0.2A @ 12 VDC, use a separate external relay. · Connect the G LED wire to the reader as shown in the wiring diagrams to synchronize the reader
indication with the button indication. Functionality and setup: · Before connecting the electric lock, configure parameters such as control output activity duration
and initial state (NO/NC). · When setting sensitivity, determine the balance between button sensitivity and false alarm
prevention. Increasing sensitivity may increase the probability of triggering under undesirable conditions, while decreasing sensitivity may result in incomplete response to desired influences. Precautions and maintenance: · The unit requires no special maintenance if the installation instructions are followed. · If the laser sensor is dirty or an obstacle is detected, the unit will activate a light and sound an alarm. · In case of contamination, gently clean the surface of the button, first with a damp cloth and then with a dry cloth.

AIR-B

7

Structure of the Setup Menu

Distance

Open Delay

AUX GND Mode

Buzzer

3.93" (10 cm)

0.1 seconds

NC (normally closed)

Disable

7.88" (20 cm)

3 seconds

NO (normally open)

Enable

11.81" (30 cm)

6 seconds

19.68" (50 cm)

9 seconds

Mode Select

AIR-B

8

Connection Diagram
Connection to the ICON-Pro Controller

Red Black Yellow Green Blue

+VDC GND AUX Out Reserved G LED

AIR-B
(V3.0 Five Wire)

AIR-B

USB LED POWER DOOR 2

TYPE-C

15.4W
LAN PoE+

STATUS

NETWORK
ICON-PRO ACCESS CONTROLLER

WIEGAND 2

GND
12/24
CONT. 2 GND REX 2 +VDC GND BUZZER G LED D 1 D 0 CONT. 1 GND REX 1 +VDC GND BUZZER G LED D 1 D 0
WWW.LUMIRING.CO

DOOR 1

WIEGAND 1

ICON-Pro
9

Connection Diagram
Connection to the ICON Controller

Red Black Yellow Green Blue

+VDC GND AUX Out Reserved G LED

AIR-B
(V3.0 Five Wire)

AIR-B

WWW.LUMIRING.COM

POWER

WIEGAND 1

NETWORK
ICON ACCESS CONTROLLER

WIEGAND 2

OSDP DOOR 1 AUX

GND

12/24

POWER Wi-Fi LAN
A

FUSE WET MODE

GND

B

REX 1

GND

CONT. 1

+VDC

DOOR 2
RELAY
WET +VDC

OUT GND NC C NO

15.4W
LAN PoE+

ICON
Connect the blue wire coming from the proximity button to the
LED pin of the Wiegand port. 10

Connection Diagram
Connection to the AIR-CR Controller

Red +VDC

Black Orange

GND G LED

Blue EXIT

AIR-CR

+VDC GND EXIT
G LED

AIR-B
(V3.0 Five Wire)
Red Black Yellow
Blue

· The wire colors of the cable connecting the controller to the proximity button may vary in reality, and are given as an example.

AIR-B

11

Connection Diagram
Connection to the Magnetic Lock

Red Black Yellow Green
Blue

+VDC GND AUX GND

AIR-B
(V3.0 Five Wire)

· Specify the NC (normaly close) type in the AUX GND mode settings to control the magnetic lock.
· Specify the NO (normaly open) type in the AUX GND mode settings to control the electric latch.

Warning
Use Correct Polarity!
Magnetic Lock
MAX 200 mA
· A protective diode is used to protect the devcie from reverse currents when an electromagnetic or electromechanical lock is triggered.
· The protective diode is connected in parallel with the contacts of the lock. · THE DIODE IS CONNECTED IN REVERSE POLARITY. · The diode must be installed directly on the contacts of the lock. Suitable diodes include SR5100,
SF18, SF56, HER307, and similar. · Instead of diodes, varistors 5D330K, 7D330K, 10D470K, or 10D390K can be used, for which there is
no need to observe polarity.

AIR-B

12

Hardware Reset
Mode Select

Hardware reset 1. Make sure that the device is connected to a power source. 2. Press and hold the "Mode" and "Select" buttons simultaneously. 3. Wait for the device to emit one short beep and a long beep for 5 seconds. 4. Release the buttons immediately after the beep ends. 5. Disconnect the unit from the power source and reconnect it. 6. The hardware reset is complete. The device is ready for operation.

AIR-B

13

For Notes

AIR-B

14



References

Corel PDF Engine Version 25.2.0.301 CorelDRAW 2024